General TF101 temperature sensors use sistance Thermometer offers the best overall advantages
EN 60751/IEC 60751 platinum in repeatability and stability over a long period. High
resistance temperature detectors
(RTD). For precise temperature
accuracy allows replacement of a sensor without any
need for re-adjust of the connected measuring devices
1
measurement the Platinum Re- or thermostats.
Types / Description
Ø0,25
quirements. Very small and quick
2
1
sensor, only suitable for further
treatment. Notice: do not cut the
sensor leads. Thermal response 1,5 2,3 10
time refer to manufacturer data:
TF101K Platinum resistance temperature With 2-wire connection and cable-length of 2 m there
-50°C...+170°C sensor on ceramic substrate pro- is a temperature-failure of approx. 0.51 Ω = 1.32 K
tected by a heat-shrinkable sleeve caused by the line resistance.
and with PTFE isolated stranded Cable length: 2000 mm
wire. The TF101K version can be Weight: 10 g
installed in motor or transformer
windings. When build-in into Part numbers: T223154 2-wire
windings do not pressure the T223134 3-wire
sensor element. Precautions
Ø 4,5
ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de 2018-01-17 53
Pt 100-Temperature-Sensors Type TF
TF101R
-20...+70°C Sensor for measuring ambient temperatures inside or
outside.
Protection class IP 54. Cabling can be connected in
2- or 3- wire technique.
Housing W x H x D = 65 x 50 x 38 mm
Weight: app. 70 g
54 ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de 2018-05-18
Pt100-Temperature-Sensores Type TF
Cabling ZIEHL thermostats of TR series are generally insensitive to interference in the sensor line.
Occasionally, however, undesirable switching is unavoidable, especially when temperature
is near the switching point. For this reason it is highly recommended that cables are not
laid parallel to power current lines over long distances. When appropriate, cables should
be screened or twisted together.
Line-resistance With RTD sensors the resistance of the connecting cable should be considered, otherwise
there is an measuring error. The resistance must be compensated. The resistance of a
1
connecting cable can be calculated as follows:
Linecompensation
2-wire technique
rot
red weiß
white With 2-wire connection the line resistance is compensated for by a potentiometer in the
thermostat, by programming (e.g. TR122D, TR600) or via wiring an external resistor. The
advantage of the possibly simpler and more economical running of just two wires is counter-
acted by the disadvantage of the manual compensation required in the case of longer wiring.
Differences in resistance caused by temperature changes cannot be compensated.
3-wire technique
red red
With 3-wire connection, a third wire (sense) connected to the sensor registers the drop in
rot rot weiß
white
voltage in one line. For compensation of line resistance it is assumed that the voltage drop
in the second line is identical (i.e. the same wire and same wire temperature). Compen-
sation is then performed automatically. Possible changes of resistance in the line due to
temperature changes are also compensated for.
4-wire technique
red red weiß white
white weiß
With 4-wire connection, impressed current flows via two wires to the sensor. Via a two
sensor line the drop in voltage is measured directly at the sensor. Possible differences
in the sensor connection wiring can be disregarded. A disadvantage is the higher costs
involved in running 4 wires.
ZIEHL thermostats, series TR are designed for use with 2 or 3-wire connection.
ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de 55
Pt100-Temperature-Sensors Type TF
Pt100 resistance table Basic values in Ω for measuring resistors Pt 100 according to DIN/ IEC 751
°C Ω °C Ω °C Ω °C Ω °C Ω °C Ω
-200 18,49 0 100,00 200 175,84 400 247,04 600 313,59 800 375,51
-190 22,80 10 103,90 210 179,51 410 250,48 610 316,80 810 378,48
-180 27,08 20 107,79 220 183,17 420 253,90 620 319,99 820 381,45
-170 31,32 30 111,67 230 186,82 430 257,32 630 323,18 830 384,40
-160 35,53 40 115,54 240 190,45 440 260,72 640 326,35 840 387,34
-150 39,71 50 119,40 250 194,07 450 264,11 650 329,51 850 390,26
-140 43,87 60 123,24 260 197,69 460 267,49 660 332,66
-130 48,00 70 127,07 270 201,29 470 270,86 670 335,79
-120 52,11 80 130,89 280 204,88 480 274,22 680 338,92
-110 56,19 90 134,70 290 208,45 490 277,56 690 342,03
-100 60,25 100 138,50 300 212,02 500 280,90 700 345,13
- 90 64,30 110 142,29 310 215,57 510 284,22 710 348,22
- 80 68,33 120 146,06 320 219,12 520 287,53 720 351,30
- 70 72,33 130 149,82 330 222,65 530 290,83 730 354,37
- 60 76,33 140 153,58 340 226,17 540 294,11 740 357,42
- 50 80,31 150 157,31 350 229,67 550 297,39 750 360,47
- 40 84,27 160 161,04 360 233,17 560 300,65 760 363,50
- 30 88,22 170 164,76 370 236,65 570 303,91 770 366,52
- 20 92,16 180 168,46 380 240,13 580 307,15 780 369,53
- 10 96,09 190 172,16 390 243,59 590 310,38 790 372,52
Pt1000 resistance table values see Pt100, multiplicated by the factor of 10.