The document provides instructions for cleaning the drain holes of pitot probes on aircraft.

The task being performed is cleaning of the pitot probe drain holes (task number 34-10-00-170-004-A).

Safety precautions that need to be followed include opening specific circuit breakers in a certain sequence to prevent probes from overheating, and having a second mechanic inspect quick disconnect couplings if more than one probe is disconnected.

JOB CARD MPD-TASK: 341300-11

HIM - A318/A319/A320/A321 AMM TASK : 34-10-00-170-004-A


34-10-00 PB 301

TITLE:
A/C Reg.:
34-10-00-170-004-A - Cleaning
** ON A/C ALL
of the Pitot Probe Drain Holes
CARD: ZONE: 125, 126 INTERVAL:
SKILL: ACCESS: 812, 822, 812

MECH. INSP.

** ON A/C ALL

TASK 34-10-00-170-004-A
Cleaning of the Pitot Probe Drain Holes

WARNING: MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER
RADAR ARE OPENED, SAFETIED AND TAGGED.

WARNING: OPEN THE PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3),


4DA1(2,3) AND 5DA1(2,3) BEFORE YOU OPEN THE PHC CIRCUIT BREAKERS
2DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE:
- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO
MAINTENANCE PERSONNEL.

FIN : 9DA1 , 9DA2 , 9DA3


1. Reason for the Job
Refer to the MPD TASK: 341300-11
CLEANING OF 1 OUT OF 3 PITOT PROBES.
· To remove dust and particles from the pitot probes.
2 Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment

REFERENCE QTYDESIGNATION
No specific 1 ACCESS PLATFORM 2M (6 FT)
NITROGEN COMPRESSED SOURCE 2 BAR (29 PSI) -
No specific AR DRY
No specific AR SAFETY CLIP - CIRCUIT BREAKER
No specific AR WIRE - NYLON
(98D34103004001) 2 CLEANER-PITOT PROBE
(98F34103003000) 1 FLUSHING TOOL-PITOT PROBE

B. Work Zones and Access Panels

ZONE/ACCESS ZONE DESCRIPTION


125 LATERAL AVIONIC COMPARTMENT
126 LATERAL AVIONIC COMPARTMENT
FOR 9DA1 (PROBE-PITOT, 1)
812
FOR 9DA2 (PROBE-PITOT, 2)
822
JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 1 of 7
JCP Ref: reference DATABASE REV DATE: Aug 01/2016
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Sep 24/2016 07:19
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 341300-11
HIM - A318/A319/A320/A321 AMM TASK : 34-10-00-170-004-A
34-10-00 PB 301

TITLE:
A/C Reg.:
34-10-00-170-004-A - Cleaning
** ON A/C ALL
of the Pitot Probe Drain Holes
MECH. INSP.

ZONE/ACCESS ZONE DESCRIPTION


FOR 9DA3 (PROBE-PITOT, 3)
812

C. Referenced Information

REFERENCE DESIGNATION
Energize the Ground Service Network from the External
(Ref. 24-42-00-861-001-A). Power
De-energize the Ground Service Network Supplied from
(Ref. 24-42-00-862-001-A). the External Power
(Ref. 34-11-15-000-001-A). Removal of the Pitot Probe
(Ref. 34-11-15-400-001-A). Installation of the Pitot Probe
Check of the Quick-Disconnect Coupling SHEET 1

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 2 of 7
JCP Ref: reference DATABASE REV DATE: Aug 01/2016
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Sep 24/2016 07:19
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 341300-11
HIM - A318/A319/A320/A321 AMM TASK : 34-10-00-170-004-A
34-10-00 PB 301

TITLE:
A/C Reg.:
34-10-00-170-004-A - Cleaning
** ON A/C ALL
of the Pitot Probe Drain Holes
MECH. INSP.

PIN LOCATED ON
QD MALE PART
NOT OK OK

GROOVE LOCATED
ON QD
FEMALE PART

BLUE RING

1 2 3

NOTE:

1 NOT CONNECTED

2 NOT CORRECTLY CONNECTED THE PIN IS NOT FULLY ENGAGED IN ITS GROOVE

3 CORRECTLY CONNECTED YOU CAN SEE THE BLUE RING


THE PIN IS CORRECTLY ENGAGED IN ITS GROOVE
N_MM_341000_3_AZZ2_01_00

Figure 34-10-00-991-00500-00-A / SHEET


1/1 - Check of the Quick-Disconnect Coupling
** ON A/C ALL

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 3 of 7
JCP Ref: reference DATABASE REV DATE: Aug 01/2016
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Sep 24/2016 07:19
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 341300-11
HIM - A318/A319/A320/A321 AMM TASK : 34-10-00-170-004-A
34-10-00 PB 301

TITLE:
A/C Reg.:
34-10-00-170-004-A - Cleaning
** ON A/C ALL
of the Pitot Probe Drain Holes
MECH. INSP.

3. Job Set-up
Subtask 34-10-00-861-063-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001) .
Subtask 34-10-00-865-084-A
B. Open, safety and tag this(these) circuit breaker(s):

PANEL DESIGNATION FIN LOCATION


121VU COM NAV/RADAR/2 5SQ2 K14
121VU COM NAV/RADAR/1 5SQ1 K13
FOR FIN 9DA1 (PROBE-PITOT, 1)
49VU ANTI ICE/PROBES/AOA/1 4DA1 D04
49VU ANTI ICE/PROBES/PITOT/1 3DA1 D02
122VU ANTI ICE/PROBES/1/STATIC 5DA1 Z13
122VU ANTI ICE/PROBES/1/TAT 1DA1 Z12
FOR FIN 9DA2 (PROBE-PITOT, 2)
122VU ANTI ICE/PROBES/2/TAT 1DA2 Y15
122VU ANTI ICE/PROBES/2/PITOT 3DA2 Y14
122VU ANTI ICE/PROBES/2/AOA 4DA2 Y13
122VU ANTI ICE/PROBES/2/STATIC 5DA2 Y11
FOR FIN 9DA3 (PROBE-PITOT, 3)
122VU ANTI ICE/PROBES/3/PITOT 3DA3 Z16
122VU ANTI ICE/PROBES/3/AOA 4DA3 Z15
122VU ANTI ICE/PROBES/3/STATIC 5DA3 Z14
Subtask 34-10-00-010-067-A
C. Get access to the Avionics Compartment
(1) Put the ACCESS PLATFORM 2M (6 FT) in position :
· At zone 125 to get access to pitot probes 1 (9DA1) and 3 (9DA3)
· At zone 126 to get access to pitot probe 2 (9DA2).
(2) Open the applicable access door:
(a) FOR 9DA1 (PROBE-PITOT, 1)
· 812
(b) FOR 9DA3 (PROBE-PITOT, 3)
· 812
(c) FOR 9DA2 (PROBE-PITOT, 2)
· 822.
Subtask 34-10-00-210-052-A
D. Inspection/Check of the Pitot Probe
(1) Do a general visual inspection of the Pitot probe 1 (9DA1), 2 (9DA2), or 3 (9DA3):
Make sure that the Pitot probe tube is not bent and has no holes or cracks.
If you find damage, replace the Pitot probe (Ref. AMM TASK 34-11-15-000-001)
and (Ref. AMM TASK 34-11-15-400-001) and go to Para. 5.

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 4 of 7
JCP Ref: reference DATABASE REV DATE: Aug 01/2016
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Sep 24/2016 07:19
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 341300-11
HIM - A318/A319/A320/A321 AMM TASK : 34-10-00-170-004-A
34-10-00 PB 301

TITLE:
A/C Reg.:
34-10-00-170-004-A - Cleaning
** ON A/C ALL
of the Pitot Probe Drain Holes
MECH. INSP.

(2) For any damage not covered by the step 3.D.(1), do a check of the probe in
workshop during sheduled maintenance procedures (A or C Checks, etc.). Refer
to the inspection part of the CMM 341153 for Thales Pitot probe or CMM 341109
for Rosemount (Aerospace)/Goodrich Pitot probe.
Subtask 34-10-00-860-079-A
E. Connection of the Dry Nitrogen Source

CAUTION: DO NOT CONNECT THE NITROGEN SOURCE TO THE QUICK-


DISCONNECT COUPLING OF THE ADM. IF YOU DO, DAMAGE TO THE
ISIS INDICATOR WILL OCCUR.

(1) Disconnect the quick-disconnect coupling from the total Pitot probe 1 (2 or 3).
(2) Connect FLUSHING TOOL-PITOT PROBE (98F34103003000) to the quick-
disconnect coupling of the pitot probe 1 (2 or 3). Then connect the flushing tool to
a NITROGEN COMPRESSED SOURCE 2 BAR (29 PSI) - DRY.
(3) Attach the hose to prevent movement.
4. Procedure
Subtask 34-10-00-170-061-A
A. Cleaning of the Pitot Probe Drain-Holes (for Thales Pitot Probes)
(1) Blow the gas into the hose at a pressure of 2 bars (29 psi) for approximately 3
minutes, and at the same time:
(a) Clean the drain holes of the Pitot probe 1 (2 or 3) with a CLEANER-PITOT
PROBE (98D34103004001) and a WIRE - NYLON diameter 0.7 mm (0.027
inch) then 0.8 mm (0.031 inch).

NOTE: The WIRE-NYLON must have a length of 5 mm (0.1968 in.) to


prevent contact between the metallic tool element and the pitot probe.

(2) Make sure that there is no contamination in the pressurized gas at the outlet of the
Pitot probe 1 (2 or 3).
(3) Stop the flow of gas.
(4) Disconnect the dry nitrogen source.
(5) Disconnect the FLUSHING TOOL-PITOT PROBE (98F34103003000) from the
pitot probe 1 (2 or 3).
(6) Connect the quick-disconnect coupling to the Pitot probe 1 (2 or 3).
(7) Make sure that you can see the blue ring on the quick-disconnect coupling.
(8) Pull the quick-disconnect coupling to make sure that it is correctly attached.
(9) Make sure that the quick-disconnect coupling is correctly engaged (the pin located
on the quick-disconnect male part is fully engaged into the groove located in the
quick-disconnect female part).
(Ref. Fig. Check of the Quick-Disconnect Coupling SHEET 1)
Subtask 34-10-00-170-062-A

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 5 of 7
JCP Ref: reference DATABASE REV DATE: Aug 01/2016
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Sep 24/2016 07:19
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 341300-11
HIM - A318/A319/A320/A321 AMM TASK : 34-10-00-170-004-A
34-10-00 PB 301

TITLE:
A/C Reg.:
34-10-00-170-004-A - Cleaning
** ON A/C ALL
of the Pitot Probe Drain Holes
MECH. INSP.

B. Cleaning of the Pitot Probe Drain-Holes (for Rosemount (Aerospace)/Goodrich Pitot


Probes)
(1) Blow the gas into the hose at a pressure of 2 bars (29 psi) for approximately 3
minutes, and at the same time:
(a) Clean the drain holes of the Pitot probe 1 (2 or 3) with a CLEANER-PITOT
PROBE (98D34103004001) and a WIRE - NYLON diameter 0.6 mm (0.023
inch) then 0.7 mm (0.027 inch).

NOTE: The WIRE-NYLON must have a length of 5 mm (0.1968 in.) to


prevent contact between the metallic tool element and the pitot probe.

(2) Make sure that there is no contamination in the pressurized gas at the outlet of the
Pitot probe 1 (2 or 3).
(3) Stop the flow of gas.
(4) Disconnect the dry nitrogen source.
(5) Disconnect the FLUSHING TOOL-PITOT PROBE (98F34103003000) from the
pitot probe 1 (2 or 3).
(6) Connect the quick-disconnect coupling to the Pitot probe 1 (2 or 3).
(7) Make sure that you can see the blue ring on the quick-disconnect coupling.
(8) Pull the quick-disconnect coupling to make sure that it is correctly attached.
(9) Make sure that the quick-disconnect coupling is correctly engaged (the pin located
on the quick-disconnect male part is fully engaged into the groove located in the
quick-disconnect female part).
(Ref. Fig. Check of the Quick-Disconnect Coupling SHEET 1)
Subtask 34-10-00-170-058-A
C. After the Cleaning Procedure

WARNING:IF YOU DISCONNECT PITOT PROBE 3, OR IF YOU DISCONNECT


MORE THAN ONE PITOT PROBE, MAKE SURE THAT A SECOND
QUALIFIED MECHANIC DOES A VISUAL INSPECTION OF THE QUICK-
DISCONNECT COUPLING CONNECTIONS.
THE TWO MECHANICS MUST SIGN OFF THE JOB.

(1) If you disconnect Pitot probe 3 (9DA3), or if you disconnect more than one Pitot
probe, a second qualified mechanic must do a visual inspection of the quick-
disconnect coupling connections.
(2) The two mechanics must sign off the job.
(3) Make sure that the quick-disconnect coupling is correctly engaged (the pin located
on the quick-disconnect male part is fully engaged into the groove located in the
quick-disconnect female part).
(Ref. Fig. Check of the Quick-Disconnect Coupling SHEET 1)
Subtask 34-10-00-865-085-A
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 6 of 7
JCP Ref: reference DATABASE REV DATE: Aug 01/2016
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Sep 24/2016 07:19
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 341300-11
HIM - A318/A319/A320/A321 AMM TASK : 34-10-00-170-004-A
34-10-00 PB 301

TITLE:
A/C Reg.:
34-10-00-170-004-A - Cleaning
** ON A/C ALL
of the Pitot Probe Drain Holes
MECH. INSP.

PANEL DESIGNATION FIN LOCATION


121VU COM NAV/RADAR/2 5SQ2 K14
121VU COM NAV/RADAR/1 5SQ1 K13
FOR FIN 9DA1 (PROBE-PITOT, 1)
49VU ANTI ICE/PROBES/AOA/1 4DA1 D04
49VU ANTI ICE/PROBES/PITOT/1 3DA1 D02
122VU ANTI ICE/PROBES/1/STATIC 5DA1 Z13
122VU ANTI ICE/PROBES/1/TAT 1DA1 Z12
FOR FIN 9DA2 (PROBE-PITOT, 2)
122VU ANTI ICE/PROBES/2/TAT 1DA2 Y15
122VU ANTI ICE/PROBES/2/PITOT 3DA2 Y14
122VU ANTI ICE/PROBES/2/AOA 4DA2 Y13
122VU ANTI ICE/PROBES/2/STATIC 5DA2 Y11
FOR FIN 9DA3 (PROBE-PITOT, 3)
122VU ANTI ICE/PROBES/3/PITOT 3DA3 Z16
122VU ANTI ICE/PROBES/3/AOA 4DA3 Z15
122VU ANTI ICE/PROBES/3/STATIC 5DA3 Z14
5. Close-up
Subtask 34-10-00-410-067-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the applicable access door:
(a) FOR 9DA1 (PROBE-PITOT, 1)
· 812
(b) FOR 9DA3 (PROBE-PITOT, 3)
· 812
(c) FOR 9DA2 (PROBE-PITOT, 2)
· 822.
(3) Remove the access platform(s).
Subtask 34-10-00-862-064-A
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001) .
*** END OF CARD ***

JCP Title: temporary job card package CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 7 of 7
JCP Ref: reference DATABASE REV DATE: Aug 01/2016
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Sep 24/2016 07:19
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE

You might also like