Vax Consultants Pvt. LTD.,: Pier Column Desig Details
Vax Consultants Pvt. LTD.,: Pier Column Desig Details
Vax Consultants Pvt. LTD.,: Pier Column Desig Details
Load IDs LOADS & COMBINATIONS AT TOP OF FOUNDATION, RL (+) 96.457 Congestion Factor 1.15
Load Details
& LCs Load Factors P, kN HL HT ML MT Materials Used
G1 Self Weight of Pier System 1.350 939.91 0.00 0.00 0.00 0.00 Concrete, M 35
G2 Super-structure Dead Load 0.00 0.00 0.00 0.00 Steel, Fe 500
Dislodged Condition 1.350 1587.00 0.00 0.00 0.00 0.00 Dia of Pier, D = 1800 mm
Both Span existing Condition 1.350 3174.00 0.00 0.00 0.00 0.00 Clear cover = 50 mm
G3 Back-fill Weight 1.500 2064.98 0.00 0.00 0.00 0.00 Dia of Tie = 10 mm
Fep Earth Pressure 1.500 0.00 0.00 0.00 0.00 0.00 Core dia = Dia of pier - 2 x Clear cover = 1700 mm
G4 SIDL, other than W/C 1.350 309.40 0.00 0.00 0.00 0.00 Diameter of Longitudinal Steel = 32 mm
G5 Wearing Coat Loading, W/C 1.750 149.68 0.00 0.00 0.00 0.00 Effective Cover, d' = 76.00 mm
Q Vehicular Loading, without Impact d' / D = 0.042
One Side Loaded Condition Refer Chart 59 of SP : 16
70R W 1.500 862.87 0.00 0.00 258.86 2508.43
70RW + Class A 1.500 1190.34 0.00 0.00 357.10 1559.03 CLASSIFICATION OF COLUMN PIER:
70RT 1.500 730.80 0.00 0.00 219.24 2085.02 Refer Clause 11.2 of IRC:112-2011
70RT + Class A 1.500 1081.25 0.00 0.00 324.38 1069.04 Radius of Gyration, i = (I/A) 0.5
4
Class A - One Lane 1.500 327.46 0.00 0.00 98.24 1373.01 I = 5.15039E+11 mm
2
Class A - Two Lanes 1.500 654.93 0.00 0.00 196.48 1601.96 A = 2543400 mm
Class A - Three Lanes 1.500 982.40 0.00 0.00 294.72 652.52 Radius of Gyration, i = 450.000 mm
Both Sides Loaded Condition 0.00 0.00 0.00 0.00 Length of pier (L) = 3.832 m
70R W 1.500 1150.00 0.00 0.00 172.72 3340.80 Effective Length Factor = 1.500 Refer Table 11.1 of IRC:112-2011
70RW + Class A 1.500 1787.09 0.00 0.00 178.08 1493.26 Effective Length of pier (L e ) = 5.749 m
70RT 1.500 804.99 0.00 0.00 196.99 2294.21 L e /i = 12.775
70RT + Class A 1.500 1486.77 0.00 0.00 202.72 317.16 As per Clause 16.2.1 - Pier yunder consideration is known as OTHER COLUMN
Class A - One Lane 1.500 637.07 0.00 0.00 5.36 2675.71
Class A - Two Lanes 1.500 1274.14 0.00 0.00 10.71 3121.62
Class A - Three Lanes 1.500 1911.21 0.00 0.00 16.08 1274.12
Fh Breaking Forces
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Pier Group - GP1
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Pier Group - GP1
LOAD COMBINATIONS AT TOP OF FOUNDATION, RL (+) 96.46 AND STRUCTURAL DESIGN OF PIER COLUMN
LOAD COMBINATIONS AT TOP OF FOUNDATION, RL (+) 96.457 AND STRUCTURAL DESIGN OF PIER COLUMN
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai