Design of ABUTMENT System - GROUP GA1: Vax Consultants Pvt. LTD.
Design of ABUTMENT System - GROUP GA1: Vax Consultants Pvt. LTD.
Design of ABUTMENT System - GROUP GA1: Vax Consultants Pvt. LTD.
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
As per Annexure A-1 of IRC:112-2011, following categories of ACTIONS are considered in the Design:
I - PERMANENT ACTION
A) PERMANENT ACTION - G
G1 Self Weight of Pier System due to Gravity
G2 Dead Load of Structure due to Gravity
G3 Back-Fill Weight
Fep Earth Pressure, Fep
Fs Secondary effects, such as Creep and Shrinkage, Fs
B) VARIABLE GRAVITY LOADS TREATED AS PERMANENT LOADS
G4 Superimposed Dead Loads - Hand Rail, Crash Barriers, Road Furniture,
Footpaths and other service loads
G5 Surfacing & Wearing Coat (Resurfacing Loads may also be considered)
C) QUASI PERMANENT LOADS
T Temparature Load (A load that acts for 50% or more duration during
the structure's Life)
II - VARIABLE ACTIONS
A) DUE TO VEHICULAR MOVEMENT
Q Vehicular Live Load due to Gravity
Qim Impact Load due to Vehicular Gravity Loads
Longitudinal Loads
Fh Braking Force
Ff Bearing Friction
Fcf Centrifugal Force
Qfpl Pedestrian/Foot Path Load
Fcp Live Load Surcharge Pressure
B) DUE TO ENVIRONMENTAL EFFECTS
W Wind Load
C) DUE TO HYDRAULIC ACTIONS
Gb Buoyancy Effects
Fwc Water Current Forces
The above listed forces are determined in detail and presented below.
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
300 105.795
300
300 103.233
300
150
300
2.035
600
100.898
1.500
Thickness of Return Wall 99.398
750 mm
0.750
98.148 98.648
500
500
750
750
97.398
500
2000 900 2600 X
5500
Dimensions Distance Mx
Weight
Item Description from X, in
(kN)
Nos. Length (m) Breadth (m) Height (m) m kNm
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
G3 BACK-FILL WEIGHT
Width of Heel Slab = 2.000 m
Length of Foundation = 12.000 m
FRL = 105.795 m
Foundation Level = 97.398 m
Top of Foundation Level = 98.648 m
Weight of Soil
Rectangular portion = 3087.504 kN,
acts at 4.500 m away from Point X
Triangular Portion = 108.000 kN
acts at 4.833 m away from Point X
3
Unit Weight of Soil overburden = 18 kN/m
Total Soil Overburden Weight = 3195.50 kN
acts at 4.511 m away from Point X
Weight of soil on Toe Slab is also considered. Top 1.0m thickness of soil is ignored as there can be occasions when
such depth of excavation may take place during service stage for taking service lines through in the vicinity of
Abutments.
Width of Toe Slab = 2.600 m
Length of Foundation = 12.000 m
Ground Level = 100.898 m
Foundation Level = 97.398 m
Top of Foundation Level = 3.650 m
Weight of Soil
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
G4 SIDL SUCH AS HAND RAILS, CRASH BARRIERS, FOOTPATHS& OTHER SERVICE LOADS
Support Reactions due to SIDLs are obtained from the STAAD Analysis and presented below:
G5 SURFACING & WEARING COAT LOADS (Resurfacing Loads may also be considered)
Support Reactions due to W/C are obtained from the STAAD Analysis and presented below:
Pedestal and Reaction loads due to
identification w/c
On Pedestal, R1 18.71
On Pedestal, R2 18.71
On Pedestal, R3 18.71
On Pedestal, R4 18.71
Total 74.84
T TEMPARATURE LOADS (A load that acts for 50% or more duration during the structure's Life)
No such loads act on the Supports
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
Axial MT,
LL Case Axial Load, P MT, kNm Impact
Load, P kNm
Factor (%)
With Impact Without Impact
70R W 748.52 2567.69 18.00 634.34 2176.0
70RW + Class A 1032.59 1595.85 18.00 875.07 1352.4
70RT 635.48 1994.37 10.00 577.71 1813.1
70RT + Class A 940.22 1022.56 10.00 818.45 929.6
Class A - One Lane 284.07 1405.44 18.00 240.74 1191.1
Class A - Two Lanes 568.14 1639.80 18.00 481.47 1389.7
Class A - Three Lanes 852.21 667.93 18.00 722.21 566.0
Ff BEARING FRICTION
Secondary effects are due to temperature and shrinkage.
Refer Clause no. 211 of IRC:6-2010
Shrinkage strain = 0.0002
Coefficient of thermal expansion = 0.0000117
Maximum temperature variation = 17.5 deg.
Temperature Strain = 0.00020475
Total Strain = 0.00040475
Total change in the length of the longitudinal girder = 8.08 mm
Design change in length (10% more is considered) = 8.89 mm
Change in length effective per support = 4.44 mm
Details of Bearings Adopted are:
Length lo = 500 mm
Breath bo = 360 mm
Overall Thickness = 96 mm
Side cover, c = 6 mm
Outer Cover he = 6 mm
Number of layers of neoprane = 5 nos.
Number of Steel Plates = 6 Nos.
Thickness of Elastomer hi = 12 mm
Thickness of steel plates hs = 4 mm
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
MT at
MT at Top of
Reaction on Centrifugal Foundatio
Live Load Case Foundation
Pier, W, kN Force, C, kN n Level,
Level, kNm
kNm
One Side Loaded Condition
70R W 1000.00 0.000 0.000 0.000
70RW + Class A 1540.00 0.000 0.000 0.000
70RT 700.00 0.000 0.000 0.000
70RT + Class A 1240.00 0.000 0.000 0.000
Class A - One Lane 540.00 0.000 0.000 0.000
Class A - Two Lanes 1080.00 0.000 0.000 0.000
Class A - Three Lanes 1620.00 0.000 0.000 0.000
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
Clause 217.3 of IRC:6 states that if adequate length of approach slab is provided, no Live Load Surcharge need to be
considered.
However,Cl.714.4 of IRC:78 states that a Live Load Surcharge equivalent to 1.2 m height of backfill shall be
considered in the design. Hence, the same is considered.
Lateral pressure = 6.422 kN/Sq.m.
Total lateral load = 647.10 kN, at bottom of foundation and it acts at an inclination of
20 Degrees with horizontal
= 550.77 kN, at top of Foundation and acts at
At Bottom of Foundation 20 degrees with horizontal
Horizontal component = 608.08 kN, acts at 4.1985 m above point X
And, vertical component = 221.32 kN acts at 3.500 m from point X
This component is ignored, to be on conservative side
Moment about Point X = 2553.02 kNm, at bottom of pile cap
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
Gb BUOYANCY EFFECTS:
100% buoyancy effects are considered and the calculations are provided below. Self weight of the abutment system
and self weight of soil overburden decreases due to buoyancy and the effects of the same are determined below.
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
C = 0.3827
D = 0.9398
Ca, Active Earth Pr. Coefficient = 0.29749 (Under Normal conditions)
Seismic Effects on Active Earth Pressure Forces
Due to normal
Due to Seismic Effects
conditions
At Bottom of
Description At top of Foundation
Foundation
Seismic Normal Seismic Normal
Effects Effects Effects Effects
Height 7.147 8.397
Pressure Ordinate (kN/Sq.m.) 48.496 38.271 56.977 44.964
Total Force per m 173.299 136.761 239.220 188.8
Total Force, kN 2079.589 1641.131 2870.637 2265.4
Horizontal Component, kN 1954.300 1542.258 2697.690 2128.9
Lever Arm 3.002 3.527
Rigid Body Moment 5866.301 4629.456 9514 7508
Resultant Moment about Point X 5866.301 4629.456 9514 7508
Increment in Active Earth Pressure Loads due to Seismic Effects
Horizontal Loads 412.042 568.778
Moment about Point X 1236.844 2005.932
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
1587.00 158.70 1
Back-fill Weight 2
Earth Pressure 1541.25 -4626.42 3
SIDL, other than W/C 154.70 15.47 4
Wearing Coat Loading, W/C 74.84 7.48 5
Vehicular Loading, without Impact 6
One Side Loaded Condition 7
70R W 634.34 63.43 2176.0 8
70RW + Class A 875.07 87.51 1352.4 9
70RT 577.71 57.77 1813.1 10
70RT + Class A 818.45 81.84 929.6 11
Class A - One Lane 240.74 24.07 1191.1 12
Class A - Two Lanes 481.47 48.15 1389.7 13
Class A - Three Lanes 722.21 72.22 566.0 14
Breaking Forces 15
One Side Loaded Condition 16
70R W 33.98 100.00 -479.74 17
70RW + Class A 38.57 113.50 -544.50 18
70RT 23.79 70.00 -335.82 19
70RT + Class A 28.37 83.50 -400.58 20
Class A - One Lane 18.35 54.00 -259.06 21
Class A - Two Lanes 36.70 108.00 -518.12 22
Class A - Three Lanes 41.28 121.50 -582.88 23
Bearing Friction Effects 41.92 -202.54 24
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
Centrifugal Forces 25
One Side Loaded Condition 26
70R W 0.00 0.0 27
70RW + Class A 0.00 0.0 28
70RT 0.00 0.0 29
70RT + Class A 0.00 0.0 30
Class A - One Lane 0.00 0.0 31
Class A - Two Lanes 0.00 0.0 32
Class A - Three Lanes 0.00 0.0 33
Live Load Surcharge Pressure 517.56 -3698.99 34
Wind Forces 35
One Side Loaded Condition 83.30 36.77 147.08 -257.17 1028.7 36
Vehicular Collision Load 37
Seismic Forces 38
Seismic Foces - Long - Due to all Inertia Loads 262.87 -1582.60 39
Seismic Foces - Tran. - Due to all Inertia Loads 40
70R W 275.05 -1684.3 41
70RW + Class A 279.67 -1722.8 42
70RT 273.96 -1675.2 43
70RT + Class A 278.58 -1713.8 44
Class A - One Lane 267.49 -1621.2 45
Class A - Two Lanes 272.12 -1659.8 46
Class A - Three Lanes 276.74 -1698.3 47
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai
Vax Consultants Pvt. Ltd., Construction of Grade Separator at Medavakkam
Foundation & Structural Engineers Detailed Design Calculations for Abutment Group - GA1
Centrifugal Forces
One Side Loaded Condition
70R W 0.0 0.0
70RW + Class A 0.0 0.0
70RT 0.0 0.0
70RT + Class A 0.0 0.0
Class A - One Lane 0.0 0.0
Class A - Two Lanes 0.0 0.0
Class A - Three Lanes 0.0 0.0
Live Load Surcharge Pressure 608.1 -2553.0
Wind Forces
One Side Loaded Condition 83.30 36.8 147.1 303.1 1212.5
Buoyancy Effects 0.00 0.0
Vehicular Collision Load
Seismic Forces
Seismic Foces - Long - Due to all Inertia Loads 262.9 1911.2
Seismic Foces - Tran. - Due to all Inertia Loads 262.871 1911.2
Seismic Foces - Tran. - Due to VLL
70R W 60.9 584.4
70RW + Class A 84.0 806.2
70RT 55.5 532.3
70RT + Class A 78.6 754.0
Class A - One Lane 23.1 221.8
Class A - Two Lanes 46.2 443.6
Class A - Three Lanes 69.3 665.4
Due to Backfill 568.8 2005.9
Divisional Engineer,
Chennai Metro Development Project - III, Division - IV,
Alandur, Chennai