Planning and preliminary Design


• Abutment type: RCC type Abutment

• Materials : M20 grade of concrete for abutment stem


M25 grade of concrete for abutment cap Fe415 HYSD
bars for all RC work

• Geometry of Abutment:

Seating width : 800mm

Height of dirt wall = 1.35m Thickness of dirt wall = 0.25m


Width of stem of abutment = 1m

Thickness of footing = 0.76m

Width of footing (B) = 3m

Thickness of abutment cap = 350mm

Width of abutment cap = 750mm

Length of abutment = 8800m


Cross-section of Abutment
Forces acting on abutment (per unit length)
1. Total Load from superstructure =143.489KN/m
2. Weight of wearing coat = 28.125KN/m
3. Weight of approach slab = 11.186KN/m
4. Live load from superstructure = 47.401 KN/m
5. Load from braking effort
• Horizontal braking load per unit length = 7.955 KN/m
Vertical reaction due to braking load per unit
length=0.802KN/m
6. Wind load[Refer bearing design]
• Transverse Wind load per unit length = 4.753KN/m
Longitudinal Wind load per unit length = 1.188 KN/m
7. Seismic Load due to the DL and LL from superstructure
• Seismic load in transverse direction per unit length = 38.256KN/m
Seismic load in longitudinal direction per unit length = 34.437KN/m

8. Load due to temperature variation, creep and shrinkage effect =


0.673KN/m
9. Self- weight of Abutment = 199.735 KN/m

10. Seismic load due to the self weight of abutment = 5.447KN/m

11. Load due to static earth pressure


• Horizontal component of load /length = 105.215KN/m
Vertical component of load/ length = 46.845KN/m
12. Load due to dynamic earth pressure
Horizontal component of load/length =105.215KN/m
Vertical component of load/length = 55.382KN/m

13. Surcharge Load


Horizontal component of load per unit load = 33.424 KN/m
Vertical component of load per unit load = 14.881KN/m

14. Backfill weight on heel slab of footing = 368.046KN/m

15. Weight of footing = 100.000KN/m


Design of Abutment stem
Methodology

• Abutment stem has been designed as a


cantilever slab.
• Design bending moment is higher in seismic
combination of loads
• So, design of abutment stem has been carried
out for seismic combination of loads only.
• using limit state method for the calculation of
reinforcement of abutment stem.
• Results

a. Main vertical bars (vertical bars in the side of backfill)


Provide 28mm φ bar @ 200 mm c/c, on calculation
b. Outer vertical reinforcement (vertical bars)
Provide 16 mm φ bar @ 250 mm c/c,
c. Horizontal Reinforcement
Provided 15 - 12 mm φ on each face of abutment
Design of Abutment footing
• Design Data
Factor axial load= 858 KN
Eccentricity=570 mm
• σtoe = 318.124 kN/m2
• σheel = 176.042 kN/m2
RESULT
• Moment about AA axis =1454.241 kN-m
• Moment about BB axis = 236.627 kN-m
• From one way shear overall footing depth =
1.4m
• Reinforcement: 20mm dia bar @ 90mm c/c in
both direction of abutment slab