Test Report issued under the responsibility of:

NCB TÜV SÜD PSB Pte Ltd.


1 Science Park Drive, 118221 Singapore
Singapore

TEST REPORT
IEC 60950-1
Information technology equipment – Safety –
Part 1: General requirements

Report Number. .............................. : 085-110044304-000


Date of issue ................................... : 2015-09-07
Total number of pages.................... 48

Applicant’s name ........................... : Mass Power Electronic Limited


Address ........................................... : 10/F, TOWER A, BILLION CENTRE 1 WANG KWONG ROAD,
KOWLOON BAY, KOWLOON, HONG KONG.
Test specification:
Standard .......................................... : IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
Test procedure ............................... : CB Scheme
Non-standard test method ............ : N/A
Test Report Form No. .................... : IEC60950_1F
Test Report Form(s) Originator .... : SGS Fimko Ltd
Master TRF...................................... : Dated 2014-02
Copyright © 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment
and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 3 of 48
Report No.: 085-110044304-000

List of Attachments (including a total number of pages in each attachment):


nd
Attachment No. 1: 71 pages of National and Group Differences for IEC 60950-1 2 Ed.
+A1:2009+A2:2013 as per CB Bulletin;
Attachment No. 2: 19 pages of European Group Differences and National Differences for EN 60950-
1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013;
Attachment No. 3: 2 pages of circuit diagram drawing, PCB layout drawing;
Attachment No. 4: 8 pages of EU plug test report for EN 50075:1990 and UK plug test report for BS
1363-3:1995 + Amd. No. 9543, 14225, 14540, 17437 & A4 and BS 1363-1:1995 +
Amd. No. 9541, 14539, 17435 & A4;
Attachment No. 5: 3 pages of model list;
Attachment No. 6: 11 pages of photo document.
Summary of testing:

Tests performed (name of test and test Testing location:


clause): TÜV SÜD Certification and Testing (China) Co.,
The submitted samples were found to comply with Ltd. Guangzhou Branch
the requirements of: 5F, Communication Building, 163 Pingyun Rd,
- IEC 60950-1:2005 + A1:2009 + A2:2013; Huangpu Ave. West, Guangzhou 510656, PR
- EN 60950-1:2006 + A11:2009 + A1:2010 + China
A12:2011 + A2:2013;
- The EU plug and UK plug have been evaluated
in this report, the other mains plugs should be
assessed to the national standard when national
approval.
- The selected models for test are the most
representative, if no specified, the model
SCF1200042E1BA was the selected model for
test:
Model type Performed test
SCF0500100E1BA Input test, energy
(5,0V/1,00A) hazard test, SELV circuit
test, working voltage
SCF0810062E1BA test, normal heating test,
(8,1V/0,62A) short-cicuited output
terminals and overload
test
SCF1200042G1BA Mechanical strength
(12,0V/0,42A) test, torque test, drop
test
SCF1200042E1BA Full test
(12,0V/0,42A)
- Before placing the products in the different
countries, the manufacturer must ensure that:
Operating Instructions, Ratings Labels and
Warnings Labels are in an Accepted or Official
Language of the country in question; The
equipment complies with the National Standards
and/or Electrical Codes of the country, province or
city or in question.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 4 of 48
Report No.: 085-110044304-000
Summary of compliance with National Differences:
List of countries addressed: National Differences and Group Differences as per CB bulletin. See
attachment of National and Group Differences for details

The product fulfils the requirements of EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013

Copy of marking plate (representative):


The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective Certification Bodies that own these marks.

These are representative labels; the others are identical with them except model name, output rating.
Minimum height of CE mark is 5mm, minimum height of WEEE mark is 7mm.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 5 of 48
Report No.: 085-110044304-000
Test item particulars...................................................:
Equipment mobility.................................................: [] movable [] hand-held [] transportable
[] stationary [] for building-in [√] direct plug-in
Connection to the mains........................................: [√] pluggable equipment [√] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[] not directly connected to the mains
Operating condition................................................: [√] continuous
[] rated operating / resting time:
Access location ......................................................: [√] operator accessible
[] restricted access location
Over voltage category (OVC) ................................: [] OVC I [√] OVC II [] OVC III [] OVC IV
[] other:
Mains supply tolerance (%) or absolute mains
supply values .........................................................: +10%, -10% (requested by applicant)
Tested for IT power systems .................................: [√] Yes [] No
IT testing, phase-phase voltage (V) ......................: 230V (only for Norway)
Class of equipment ................................................: [] Class I [√] Class II [] Class III
[] Not classified
Considered current rating of protective device as 16A except 13A for United Kingdom
part of the building installation (A) .......................: (20A for Canada and United States)
Pollution degree (PD) .............................................: [] PD 1 [√] PD 2 [] PD 3
IP protection class ..................................................: IP20
Altitude during operation (m) ................................: < 2000 m
Altitude of test laboratory (m) ...............................: < 500
Mass of equipment (kg) .........................................: Approx. 0.07kg
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement.................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing.......................................................................... :
Date of receipt of test item ........................................ : 2015-07-21
Date (s) of performance of tests ............................... : 2015-07-22 to 2015-08-22

General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.

Throughout this report a comma / point is used as the decimal separator.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 6 of 48
Report No.: 085-110044304-000
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has Yes
been provided ............................................................... : Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Shenzhen Mass Power Electronic Limited
437#, Hedong Village, Hengkeng Community,
Guanlan Street, Bao’an District, 518110 Shenzhen,
PEOPLE'S REPUBLIC OF CHINA.
General product information:
1. These switch mode power supplies are designed for supply information technology equipment, for
indoor use only and ambient temperature 45°C Max.
2. Models SCFxxxyyyyz1mn (xxx=036-120; yyyy=0005-0100; z=A, C, E, G, I, K, M, O; m=B, W, G, L;
n=A-Z or 0-9);
xxx=036-120 indicates rated output voltage range 3,6-12,0 V d.c.;
yyyy=0005-0100 indicates rated output current range 50-1000 mA;
z=A, C, E, G, I, K, M, O, indicates type of the AC plug,
z=A, sample with United States, Japan or Taiwan plug,
z=C, sample with China plug,
z=E, sample with Europe plug,
z=G, sample with United Kingdom, Hongkong or Singapore plug,
z=I, sample with Australia plug,
z=K, sample with Korean plug,
z=M, sample with Argentina plug,
z=O, sample with India plug.
m=B, W, G, L, indicates the color of enclosure, n=A-Z or 0-9, indicates the customer code.
3. All models are similar except parameter of transformer and some components.
4. These adaptors’s top enclosure is secured to bottom enclosure by ultrasonic welding.
5. These models are in compliance with the requirements of sub clause 2.5 (limited power source).

Abbreviations used in the report:

- normal conditions N.C. - single fault conditions S.F.C


- functional insulation OP - basic insulation BI
- double insulation DI - supplementary insulation SI
- between parts of opposite
polarity BOP - reinforced insulation RI

Indicate used abbreviations (if any)

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 7 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1 GENERAL P

1.5 Components P
1.5.1 General Components which were found P
to affect safety aspects comply
with the requirements of this
standard or within the safety
aspects of the relevant IEC
component standards.
Comply with IEC 60950-1 or relevant component (see appended tables 1.5.1) P
standard
1.5.2 Evaluation and testing of components Components which are certified P
to IEC and /or national
standards are used correctly
within their ratings.
Components not covered by
IEC standards are tested under
the conditions present in the
equipment.
1.5.3 Thermal controls No thermal controls provided. N/A
1.5.4 Transformers Transformer used are suitable P
for their intended application
and comply with the relevant
requirements of the standard
and particularly Annex C.
1.5.5 Interconnecting cables Interconnection o/p cable to P
other device is carrying only
SELV on an energy level below
240 VA.
1.5.6 Capacitors bridging insulation N/A
1.5.7 Resistors bridging insulation N/A
1.5.7.1 Resistors bridging functional, basic or N/A
supplementary insulation
1.5.7.2 Resistors bridging double or reinforced insulation N/A
between a.c. mains and other circuits
1.5.7.3 Resistors bridging double or reinforced insulation N/A
between a.c. mains and antenna or coaxial cable
1.5.8 Components in equipment for IT power systems P
1.5.9 Surge suppressors N/A
1.5.9.1 General N/A
1.5.9.2 Protection of VDRs N/A
1.5.9.3 Bridging of functional insulation by a VDR N/A
1.5.9.4 Bridging of basic insulation by a VDR N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 8 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1.5.9.5 Bridging of supplementary, double or reinforced N/A


insulation by a VDR

1.6 Power interface P


1.6.1 AC power distribution systems TN and IT (Only for Norway) P
1.6.2 Input current Highest load according to P
1.2.2.1 for this equipment is the
operation with the max.
specified DC-load.
(see appended table 1.6.2)
1.6.3 Voltage limit of hand-held equipment Not hand-held equipment N/A
1.6.4 Neutral conductor P

1.7 Marking and instructions P


1.7.1 Power rating and identification markings P
1.7.1.1 Power rating marking P
Multiple mains supply connections.........................: Only one mains supply N/A
connection
Rated voltage(s) or voltage range(s) (V) ............... : See page 2 P
Symbol for nature of supply, for d.c. only............... : Mains from AC source N/A
Rated frequency or rated frequency range (Hz) ... : See page 2 P
Rated current (mA or A) ........................................ : See page 2 P
1.7.1.2 Identification markings P
Manufacturer’s name or trade-mark or Trademark was shown P
identification mark ................................................. :
Model identification or type reference ................... : See page 2 P
Symbol for Class II equipment only ...................... : P

Other markings and symbols ................................ : Other marks do not give rise to P
misunderstanding
1.7.1.3 Use of graphical symbols P
1.7.2 Safety instructions and marking P
1.7.2.1 General P
1.7.2.2 Disconnect devices N/A
1.7.2.3 Overcurrent protective device Pluggable equipment type A N/A
1.7.2.4 IT power distribution systems Only for Norway P
1.7.2.5 Operator access with a tool No such area N/A
1.7.2.6 Ozone N/A
1.7.3 Short duty cycles Continuous operation N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 9 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1.7.4 Supply voltage adjustment ................................... : Only one supply voltage range N/A
Methods and means of adjustment; reference to N/A
installation instructions ......................................... :
1.7.5 Power outlets on the equipment .......................... : No outlet used N/A
1.7.6 Fuse identification (marking, special fusing Non-replaceable fusible resistor P
characteristics, cross-reference) ............................: “10ohm/1W” marked on PCB
near RF1
1.7.7 Wiring terminals No such terminals N/A
1.7.7.1 Protective earthing and bonding terminals ..............: N/A
1.7.7.2 Terminals for a.c. mains supply conductors N/A
1.7.7.3 Terminals for d.c. mains supply conductors N/A
1.7.8 Controls and indicators No switch used N/A
1.7.8.1 Identification, location and marking .........................: N/A
1.7.8.2 Colours ...................................................................: N/A
1.7.8.3 Symbols according to IEC 60417............................: N/A
1.7.8.4 Markings using figures ..........................................: N/A
1.7.9 Isolation of multiple power sources ........................: Only one power source N/A
1.7.10 Thermostats and other regulating devices .............: N/A
1.7.11 Durability Rubbing test for 15 s with water P
then for 15 s with petroleum
spirit, no curling and legible
after test
1.7.12 Removable parts Rating label stick on enclosure N/A
and no removable part within
equipment
1.7.13 Replaceable batteries ......................................... : No batteries used N/A
Language(s) ........................................................ : 
1.7.14 Equipment for restricted access locations ........... : No restricted access lication N/A

2 PROTECTION FROM HAZARDS P


2.1 Protection from electric shock and energy hazards P
2.1.1 Protection in operator access areas P
2.1.1.1 Access to energized parts No access with test finger and P
test pin to any parts with only
basic insulation to ELV or
hazardous voltage
Test by inspection ................................................. : P
Test with test finger (Figure 2A) ........................... : Hazardous parts not accessible P
Test with test pin (Figure 2B) ................................ : Hazardous parts not accessible P

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 10 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Test with test probe (Figure 2C) ........................... : No TNV circuit within N/A
equipment
2.1.1.2 Battery compartments N/A
2.1.1.3 Access to ELV wiring N/A
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm)
2.1.1.4 Access to hazardous voltage circuit wiring N/A
2.1.1.5 Energy hazards ..................................................... : (see appended tables 2.1.1.5) P
2.1.1.6 Manual controls N/A
2.1.1.7 Discharge of capacitors in equipment No X capacitor used N/A
Measured voltage (V); time-constant (s) ............... : 
2.1.1.8 Energy hazards – d.c. mains supply Connected to a.c. mains supply N/A
only
a) Capacitor connected to the d.c. mains supply . : N/A
b) Internal battery connected to the d.c. mains N/A
supply :
2.1.1.9 Audio amplifiers .................................................... : No such amplifier N/A
2.1.2 Protection in service access areas N/A
2.1.3 Protection in restricted access locations N/A

2.2 SELV circuits P


2.2.1 General requirements 42.4V peak or 60VDC are not P
exceeded in outputs of power
supply under normal operation
or single fault condition.
(see appended table 2.2)
2.2.2 Voltages under normal conditions (V) .................. : Each output of power supply is P
not exceeded 42.4V peak or
60VDC
2.2.3 Voltages under fault conditions (V) ....................... : Single fault did not cause P
excessive voltage in accessible
outputs. Limits of 71V peak and
120V DC were not exceed and
SELV limits not for longer than
0.2 seconds
(see appended table 2.2)
2.2.4 Connection of SELV circuits to other circuits ......: No direct connection between P
SELV and any primary circuits

2.3 TNV circuits N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 11 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.3.1 Limits No TNV circuit within N/A


equipment
Type of TNV circuits .............................................. : 
2.3.2 Separation from other circuits and from accessible N/A
parts
2.3.2.1 General requirements N/A
2.3.2.2 Protection by basic insulation N/A
2.3.2.3 Protection by earthing N/A
2.3.2.4 Protection by other constructions ......................... : N/A
2.3.3 Separation from hazardous voltages N/A
Insulation employed ............................................... : 
2.3.4 Connection of TNV circuits to other circuits N/A
Insulation employed ............................................... : 
2.3.5 Test for operating voltages generated externally N/A

2.4 Limited current circuits N/A


2.4.1 General requirements N/A
2.4.2 Limit values N/A
Frequency (Hz) ...................................................... : 
Measured current (mA) .......................................... : 
Measured voltage (V) ............................................ : 
Measured circuit capacitance (nF or µF) ............... : 
2.4.3 Connection of limited current circuits to other N/A
circuits

2.5 Limited power sources P


a) Inherently limited output N/A
b) Impedance limited output N/A
c) Regulating network or IC current limiter, limits (see appended table 2.5) P
output under normal operating and single fault
condition
Use of integrated circuit (IC) current limiters N/A
d) Overcurrent protective device limited output N/A
Max. output voltage (V), max. output current (A), (see appended table 2.5) 
max. apparent power (VA) ..................................... :
Current rating of overcurrent protective device (A) .: 

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 12 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.6 Provisions for earthing and bonding N/A


2.6.1 Protective earthing Class II equipment N/A
2.6.2 Functional earthing N/A
Use of symbol for functional earthing ...................: N/A
2.6.3 Protective earthing and protective bonding N/A
conductors
2.6.3.1 General N/A
2.6.3.2 Size of protective earthing conductors N/A
2
Rated current (A), cross-sectional area (mm ), 
AWG ...................................................................... :
2.6.3.3 Size of protective bonding conductors N/A
2
Rated current (A), cross-sectional area (mm ), 
AWG ...................................................................... :
Protective current rating (A), cross-sectional area 
2
(mm ), AWG........................................................... :
2.6.3.4 Resistance of earthing conductors and their N/A
terminations; resistance (Ω), voltage drop (V), test
current (A), duration (min) ..................................... :
2.6.3.5 Colour of insulation ................................................ : N/A
2.6.4 Terminals N/A
2.6.4.1 General N/A
2.6.4.2 Protective earthing and bonding terminals N/A
Rated current (A), type, nominal thread diameter 
(mm)....................................................................... :
2.6.4.3 Separation of the protective earthing conductor N/A
from protective bonding conductors
2.6.5 Integrity of protective earthing N/A
2.6.5.1 Interconnection of equipment N/A
2.6.5.2 Components in protective earthing conductors and N/A
protective bonding conductors
2.6.5.3 Disconnection of protective earth N/A
2.6.5.4 Parts that can be removed by an operator N/A
2.6.5.5 Parts removed during servicing N/A
2.6.5.6 Corrosion resistance N/A
2.6.5.7 Screws for protective bonding N/A
2.6.5.8 Reliance on telecommunication network or cable N/A
distribution system

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 13 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.7 Overcurrent and earth fault protection in primary circuits P


2.7.1 Basic requirements Equipment relies on 16A rated P
fuse or circuit breaker of the
wall outlet installation protection
of the building installation in
regard to L to N short circuit.
Over-current protection is
provided by the fusible resistor.
Instructions when protection relies on building Not applicable for pluggable N/A
installation equipment type A
2.7.2 Faults not simulated in 5.3.7 The protection device is well P
dimensioned and mounted.
2.7.3 Short-circuit backup protection Pluggable equipment type A. P
Building installation is
considered as providing short-
circuit backup protection.
2.7.4 Number and location of protective devices .......... : Minimum one protective device P
is located in either of the two
conductors.
2.7.5 Protection by several devices Only one protection device N/A
2.7.6 Warning to service personnel ................................ : No service work necessary. N/A

2.8 Safety interlocks N/A


2.8.1 General principles No safety interlocks N/A
2.8.2 Protection requirements N/A
2.8.3 Inadvertent reactivation N/A
2.8.4 Fail-safe operation N/A
Protection against extreme hazard N/A
2.8.5 Moving parts N/A
2.8.6 Overriding N/A
2.8.7 Switches, relays and their related circuits N/A
2.8.7.1 Separation distances for contact gaps and their N/A
related circuits (mm) ..............................................:
2.8.7.2 Overload test N/A
2.8.7.3 Endurance test N/A
2.8.7.4 Electric strength test (see appended table 5.2) N/A
2.8.8 Mechanical actuators N/A

2.9 Electrical insulation P

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 14 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.9.1 Properties of insulating materials No natural rubber, hygroscopic P


material and material
containing asbestos used as
insulation
2.9.2 Humidity conditioning P
Relative humidity (%), temperature (°C) ............... : RH: 93%, 45°C, 120hrs 
2.9.3 Grade of insulation Insulation complies with sub- P
clauses 2.10, 4.5.1 and 5.2.
2.9.4 Separation from hazardous voltages The secondary circuit is P
seperated from hazardaous
voltages by reinforce insulation
or double insulation
Method(s) used ..................................................... : Method 1 used 

2.10 Clearances, creepage distances and distances through insulation P


2.10.1 General P
2.10.1.1 Frequency ..............................................................: Considered P
2.10.1.2 Pollution degrees ...................................................: 2 P
2.10.1.3 Reduced values for functional insulation N/A
2.10.1.4 Intervening unconnected conductive parts N/A
2.10.1.5 Insulation with varying dimensions N/A
2.10.1.6 Special separation requirements N/A
2.10.1.7 Insulation in circuits generating starting pulses N/A
2.10.2 Determination of working voltage The rms and the peak voltage P
were measured on the
switching power supply. The
unit was connected to a 240V
TN power system and
secondary ground was
maintained during
measurement. Results see
appended table 2.10.2.
2.10.2.1 General P
2.10.2.2 RMS working voltage (Results see appended table P
2.10.2)
2.10.2.3 Peak working voltage (Results see appended table P
2.10.2)
2.10.3 Clearances P
2.10.3.1 General P
2.10.3.2 Mains transient voltages P
a) AC mains supply ................................................: 2500V P

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 15 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

b) Earthed d.c. mains supplies ..............................: N/A


c) Unearthed d.c. mains supplies ..........................: N/A
d) Battery operation ...............................................: N/A
2.10.3.3 Clearances in primary circuits (see appended table 2.10.3 and P
2.10.4)
2.10.3.4 Clearances in secondary circuits N/A
2.10.3.5 Clearances in circuits having starting pulses N/A
2.10.3.6 Transients from a.c. mains supply .........................: N/A
2.10.3.7 Transients from d.c. mains supply .........................: N/A
2.10.3.8 Transients from telecommunication networks and N/A
cable distribution systems .....................................:
2.10.3.9 Measurement of transient voltage levels N/A
a) Transients from a mains supply N/A
For an a.c. mains supply .......................................: N/A
For a d.c. mains supply .........................................: N/A
b) Transients from a telecommunication network : N/A
2.10.4 Creepage distances (see appended table 2.10.3 and P
2.10.4)
2.10.4.1 General P
2.10.4.2 Material group and comparative tracking index P
CTI tests .................................................................: Material group IIIb is assumed 
to be used
2.10.4.3 Minimum creepage distances (see appended table 2.10.3 and P
2.10.4)
2.10.5 Solid insulation P
2.10.5.1 General P
2.10.5.2 Distances through insulation (see appended table 2.10.5) P
2.10.5.3 Insulating compound as solid insulation N/A
2.10.5.4 Semiconductor devices N/A
2.10.5.5 Cemented joints N/A
2.10.5.6 Thin sheet material – General Thin sheet material not used as N/A
insulation
2.10.5.7 Separable thin sheet material N/A
Number of layers (pcs) ...........................................: 
2.10.5.8 Non-separable thin sheet material N/A
2.10.5.9 Thin sheet material – standard test procedure N/A
Electric strength test (see appended table 5.2) 
2.10.5.10 Thin sheet material – alternative test procedure N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 16 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Electric strength test (see appended table 5.2) 


2.10.5.11 Insulation in wound components Approved source of triple P
insulated wire used in T1
secondary winding for
reinforced insulation.
2.10.5.12 Wire in wound components P
Working voltage .....................................................: (see appended table 2.10.3 and P
2.10.4)
a) Basic insulation not under stress .......................: N/A
b) Basic, supplementary, reinforced insulation ......: N/A
c) Compliance with Annex U .................................: Approved triple insulated wire P
used in T1 as secondary
winding wire
Two wires in contact inside wound component; By tape P
angle between 45° and 90° ...................................:
2.10.5.13 Wire with solvent-based enamel in wound No such construction N/A
components
Electric strength test 
Routine test N/A
2.10.5.14 Additional insulation in wound components No such construction N/A
Working voltage .....................................................: N/A
- Basic insulation not under stress .........................: N/A
- Supplementary, reinforced insulation ..................: N/A
2.10.6 Construction of printed boards P
2.10.6.1 Uncoated printed boards (see appended table 2.10.3 and P
2.10.4)
2.10.6.2 Coated printed boards No coated printed boards N/A
2.10.6.3 Insulation between conductors on the same inner No multi-layer PCBs provided N/A
surface of a printed board
2.10.6.4 Insulation between conductors on different layers No multi-layer PCBs provided N/A
of a printed board
Distance through insulation (see appended table 2.10.5) N/A
Number of insulation layers (pcs) ...........................: Single layer PCB N/A
2.10.7 Component external terminations No such components N/A
2.10.8 Tests on coated printed boards and coated No such boards and componets N/A
components
2.10.8.1 Sample preparation and preliminary inspection N/A
2.10.8.2 Thermal conditioning N/A
2.10.8.3 Electric strength test (see appended table 5.2) N/A
2.10.8.4 Abrasion resistance test N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 17 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.10.9 Thermal cycling N/A


2.10.10 Test for Pollution Degree 1 environment and N/A
insulating compound
2.10.11 Tests for semiconductor devices and cemented N/A
joints
2.10.12 Enclosed and sealed parts No hermetically sealed N/A
component

3 WIRING, CONNECTIONS AND SUPPLY P


3.1 General P
3.1.1 Current rating and overcurrent protection (see appended table 4.5.1) P
3.1.2 Protection against mechanical damage Wires do not touch sharp edges P
which could damage the
insulation and cause hazard
3.1.3 Securing of internal wiring The wires are secured by P
soldering and glue so that a
loosening of the terminal
connection is unlikely
3.1.4 Insulation of conductors N/A
3.1.5 Beads and ceramic insulators No such insulators N/A
3.1.6 Screws for electrical contact pressure No such screws N/A
3.1.7 Insulating materials in electrical connections N/A
3.1.8 Self-tapping and spaced thread screws No such screws N/A
3.1.9 Termination of conductors P
10 N pull test Not loosening P
3.1.10 Sleeving on wiring N/A

3.2 Connection to a mains supply P


3.2.1 Means of connection Mains plug was used P
3.2.1.1 Connection to an a.c. mains supply P
3.2.1.2 Connection to a d.c. mains supply N/A
3.2.2 Multiple supply connections Single mains supply N/A
3.2.3 Permanently connected equipment Not permanently connected N/A
equipment
Number of conductors, diameter of cable and 
conduits (mm) ....................................................... :
3.2.4 Appliance inlets N/A
3.2.5 Power supply cords N/A
3.2.5.1 AC power supply cords N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 18 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Type ...................................................................... : 
2
Rated current (A), cross-sectional area (mm ), 
AWG ...................................................................... :
3.2.5.2 DC power supply cords N/A
3.2.6 Cord anchorages and strain relief N/A
Mass of equipment (kg), pull (N) .......................... : 
Longitudinal displacement (mm) ........................... : 
3.2.7 Protection against mechanical damage N/A
3.2.8 Cord guards N/A
Diameter or minor dimension D (mm); test mass (g) 
............................................................................... :
Radius of curvature of cord (mm) .......................... : 
3.2.9 Supply wiring space N/A

3.3 Wiring terminals for connection of external conductors N/A


3.3.1 Wiring terminals N/A
3.3.2 Connection of non-detachable power supply cords N/A
3.3.3 Screw terminals N/A
3.3.4 Conductor sizes to be connected N/A
Rated current (A), cord/cable type, cross-sectional 
2
area (mm ) ............................................................. :
3.3.5 Wiring terminal sizes N/A
Rated current (A), type, nominal thread diameter 
(mm) ...................................................................... :
3.3.6 Wiring terminal design N/A
3.3.7 Grouping of wiring terminals N/A
3.3.8 Stranded wire N/A

3.4 Disconnection from the mains supply P


3.4.1 General requirement P
3.4.2 Disconnect devices By mains plug P
3.4.3 Permanently connected equipment N/A
3.4.4 Parts which remain energized N/A
3.4.5 Switches in flexible cords N/A
3.4.6 Number of poles - single-phase and d.c. Single – phase equipment P
equipment
3.4.7 Number of poles - three-phase equipment Single – phase equipment N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 19 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

3.4.8 Switches as disconnect devices No switches N/A


3.4.9 Plugs as disconnect devices N/A
3.4.10 Interconnected equipment N/A
3.4.11 Multiple power sources Only one power source N/A

3.5 Interconnection of equipment P


3.5.1 General requirements Equipment with output type P
SELV circuit
3.5.2 Types of interconnection circuits ........................... : SELV circuit P
3.5.3 ELV circuits as interconnection circuits No ELV circuit N/A
3.5.4 Data ports for additional equipment N/A

4 PHYSICAL REQUIREMENTS P
4.1 Stability N/A
Angle of 10° N/A
Test force (N) ........................................................ : N/A

4.2 Mechanical strength P


4.2.1 General P
Rack-mounted equipment. N/A
4.2.2 Steady force test, 10 N Applied to component when P
measuring creepage distances
and clearances
4.2.3 Steady force test, 30 N N/A
4.2.4 Steady force test, 250 N Applied to enclosure for all P
models, no hazards. Enclosure
material: see table 1.5.1
4.2.5 Impact test P
Fall test P
Swing test P
4.2.6 Drop test; height (mm) .......................................... : No hazard as result from drop P
test
4.2.7 Stress relief test After 7 hours at temperature of P
96°C and cooling down to room
temperature, no shrinkage,
distortion or loosening any
enclosure part was noticeable
on the adapter.
4.2.8 Cathode ray tubes No such device N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 20 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Picture tube separately certified ............................ : N/A


4.2.9 High pressure lamps No such device N/A
4.2.10 Wall or ceiling mounted equipment; force (N) ....... : N/A

4.3 Design and construction P


4.3.1 Edges and corners All edges and corners are P
rounded and /or smoothed
4.3.2 Handles and manual controls; force (N) .............: No such component N/A
4.3.3 Adjustable controls N/A
4.3.4 Securing of parts The enclosure is fixed by P
ultrasonic welding
4.3.5 Connection by plugs and sockets No mismating of connectors, P
plugs or sockets possible
4.3.6 Direct plug-in equipment P
Torque .................................................................. : 0.05Nm max. 
Compliance with the relevant mains plug standard See attached plug test report P
.............................................................................. :
4.3.7 Heating elements in earthed equipment No heating element N/A
4.3.8 Batteries (see appended tables 4.3.8) N/A
- Overcharging of a rechargeable battery N/A
- Unintentional charging of a non-rechargeable N/A
battery
- Reverse charging of a rechargeable battery N/A
- Excessive discharging rate for any battery N/A
4.3.9 Oil and grease No insulation exposed to oil N/A
and grease
4.3.10 Dust, powders, liquids and gases Equipment do not produce N/A
dust, not use powder, liquid and
gas
4.3.11 Containers for liquids or gases No containers for liquids or N/A
gases
4.3.12 Flammable liquids ................................................ : N/A
Quantity of liquid (l) .............................................. : N/A
Flash point (°C) .................................................... : N/A
4.3.13 Radiation N/A
4.3.13.1 General N/A
4.3.13.2 Ionizing radiation N/A
Measured radiation (pA/kg) .................................. : 
Measured high-voltage (kV) ................................. : 

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 21 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Measured focus voltage (kV) ............................... : 


CRT markings ...................................................... : 
4.3.13.3 Effect of ultraviolet (UV) radiation on materials N/A
Part, property, retention after test, flammability N/A
classification ......................................................... :
4.3.13.4 Human exposure to ultraviolet (UV) radiation ...... : N/A
4.3.13.5 Lasers (including laser diodes) and LEDs N/A
4.3.13.5.1 Lasers (including laser diodes) N/A
Laser class ........................................................... : 
4.3.13.5.2 Light emitting diodes (LEDs) N/A
4.3.13.6 Other types ........................................................... : N/A

4.4 Protection against hazardous moving parts N/A


4.4.1 General No moving part within N/A
equipment
4.4.2 Protection in operator access areas .................... : N/A
Household and home/office document/media (see Annex EE) N/A
shredders
4.4.3 Protection in restricted access locations .............. : N/A
4.4.4 Protection in service access areas N/A
4.4.5 Protection against moving fan blades N/A
4.4.5.1 General N/A
Not considered to cause pain or injury. a)…………: N/A
Is considered to cause pain, not injury. b) ………...: N/A
Considered to cause injury. c) …………: N/A
4.4.5.2 Protection for users N/A
Use of symbol or warning …………………………..: N/A
4.4.5.3 Protection for service persons N/A
Use of symbol or warning …………………………..: N/A

4.5 Thermal requirements P


4.5.1 General P
4.5.2 Temperature tests (see appended table 4.5) P
Normal load condition per Annex L ...................... : Maximum normal load which 
specified by manufacturer
4.5.3 Temperature limits for materials (see appended table 4.5) P
4.5.4 Touch temperature limits (see appended table 4.5) P

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 22 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

4.5.5 Resistance to abnormal heat ............................... : (see appended table 4.5.5) P

4.6 Openings in enclosures P


4.6.1 Top and side openings No opening P
Dimensions (mm) ................................................. : 
4.6.2 Bottoms of fire enclosures P
Construction of the bottomm, dimensions (mm) .. : Two small hole in bottom of 
enclosure (Ø 0,9mm, optional)
under V-0 PCB at secondary
side
4.6.3 Doors or covers in fire enclosures N/A
4.6.4 Openings in transportable equipment P
4.6.4.1 Constructional design measures P
Dimensions (mm) ................................................. : Two small hole Ø 0,9mm 
(optional), do not exceed 1 mm
4.6.4.2 Evaluation measures for larger openings N/A
4.6.4.3 Use of metallized parts N/A
4.6.5 Adhesives for constructional purposes N/A
Conditioning temperature (°C), time (weeks) ........ : 

4.7 Resistance to fire P


4.7.1 Reducing the risk of ignition and spread of flame Method 1 used P
Method 1, selection and application of components (see appended table 4.7) P
wiring and materials
Method 2, application of all of simulated fault (see appended table 5.3) N/A
condition tests
4.7.2 Conditions for a fire enclosure See below P
4.7.2.1 Parts requiring a fire enclosure With having the following parts: P
 Components in primary
 Components in secondary
 Insulated wiring
The fire enclosure is required.
4.7.2.2 Parts not requiring a fire enclosure Transformer, etc. N/A
4.7.3 Materials P
4.7.3.1 General Parts mounted on PCB of P
flammability class V-0.
4.7.3.2 Materials for fire enclosures The fire enclosure is V-0. P
4.7.3.3 Materials for components and other parts outside Output connector insulated with P
fire enclosures PVC

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 23 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

4.7.3.4 Materials for components and other parts inside PCB rated V-0, bobbin material P
fire enclosures rated V-0, approved by UL
4.7.3.5 Materials for air filter assemblies No such devices N/A
4.7.3.6 Materials used in high-voltage components No such components N/A

5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS P


5.1 Touch current and protective conductor current P
5.1.1 General (see appended Table 5.1) P
5.1.2 Configuration of equipment under test (EUT) EUT has only one mains P
connection
5.1.2.1 Single connection to an a.c. mains supply P
5.1.2.2 Redundant multiple connections to an a.c. mains N/A
supply
5.1.2.3 Simultaneous multiple connections to an a.c. mains N/A
supply
5.1.3 Test circuit Equipment of figure 5A used P
5.1.4 Application of measuring instrument Figure 4 of IEC 60990 used P
5.1.5 Test procedure Measured between each pole P
of live parts and output
terminal, between each pole of
live parts and enclosure
5.1.6 Test measurements P
Supply voltage (V) ................................................ : 264V, 60Hz 
Measured touch current (mA) .............................. : (see appended table 5.1) 
Max. allowed touch current (mA) ......................... : (see appended table 5.1) 
Measured protective conductor current (mA) ...... : 
Max. allowed protective conductor current (mA) .. : 
5.1.7 Equipment with touch current exceeding 3,5 mA N/A
5.1.7.1 General ................................................................ : N/A
5.1.7.2 Simultaneous multiple connections to the supply N/A
5.1.8 Touch currents to telecommunication networks and No telecommunication network N/A
cable distribution systems and from connection ports on equipment
telecommunication networks
5.1.8.1 Limitation of the touch current to a N/A
telecommunication network or to a cable
distribution system
Supply voltage (V) ................................................ : 
Measured touch current (mA) .............................. : 
Max. allowed touch current (mA) ......................... : 

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 24 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

5.1.8.2 Summation of touch currents from N/A


telecommunication networks
a) EUT with earthed telecommunication ports ..... : N/A
b) EUT whose telecommunication ports have no N/A
reference to protective earth

5.2 Electric strength P


5.2.1 General (see appended table 5.2) P
5.2.2 Test procedure P

5.3 Abnormal operating and fault conditions P


5.3.1 Protection against overload and abnormal (see appended table 5.3) P
operation
5.3.2 Motors No motors N/A
5.3.3 Transformers With the shorted o/p of the P
transformer, no high
temperature of the transformer
was recorded.
Results of the short-circuit tests
see appended table 5.3 and
Annex C.
5.3.4 Functional insulation ............................................. : Method c). Test results see P
appended table 5.3
5.3.5 Electromechanical components No electromechanical N/A
component provided
5.3.6 Audio amplifiers in ITE ......................................... : No such component N/A
5.3.7 Simulation of faults (Results see appended table P
5.3)
5.3.8 Unattended equipment No thermostat, temperature N/A
limiter and thermal cut-out
incorporated in equipment.
5.3.9 Compliance criteria for abnormal operating and No fire propagated beyond the P
fault conditions equipment. No molten metal
was emitted. Electric strength
test primary to SELV was
passed.
5.3.9.1 During the tests During the test, no fire P
propagated beyond equipment;
not emit molten metal and
enclosure did not deform.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 25 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

5.3.9.2 After the tests After the test, no any insulation P


damaged and withstand
dielectric strength test
AC3000V between live parts
and accessible parts.

6 CONNECTION TO TELECOMMUNICATION NETWORKS N/A


6.1 Protection of telecommunication network service persons, and users of other N/A
equipment connected to the network, from hazards in the equipment
6.1.1 Protection from hazardous voltages N/A
6.1.2 Separation of the telecommunication network from earth N/A
6.1.2.1 Requirements (see appended table 5.2) N/A
Supply voltage (V) ................................................ : 
Current in the test circuit (mA) ........................... : 
6.1.2.2 Exclusions ............................................................ : N/A

6.2 Protection of equipment users from overvoltages on telecommunication N/A


networks
6.2.1 Separation requirements N/A
6.2.2 Electric strength test procedure N/A
6.2.2.1 Impulse test N/A
6.2.2.2 Steady-state test N/A
6.2.2.3 Compliance criteria N/A

6.3 Protection of the telecommunication wiring system from overheating N/A


Max. output current (A) ........................................ : 
Current limiting method ........................................ : 

7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N/A


7.1 General N/A
7.2 Protection of cable distribution system service N/A
persons, and users of other equipment connected to
the system, from hazardous voltages in the
equipment
7.3 Protection of equipment users from overvoltages on N/A
the cable distribution system
7.4 Insulation between primary circuits and cable N/A
distribution systems
7.4.1 General N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 26 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

7.4.2 Voltage surge test N/A


7.4.3 Impulse test N/A

A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE N/A


A.1 Flammability test for fire enclosures of movable N/A
equipment having a total mass exceeding
18 kg, and of stationary equipment (see 4.7.3.2)
A.1.1 Samples................................................................. : 
Wall thickness (mm) .............................................. : 
A.1.2 Conditioning of samples; temperature (°C) .......... : N/A
A.1.3 Mounting of samples ............................................ : N/A
A.1.4 Test flame (see IEC 60695-11-3) N/A
Flame A, B, C or D ............................................... : 
A.1.5 Test procedure N/A
A.1.6 Compliance criteria N/A
Sample 1 burning time (s) ..................................... : 
Sample 2 burning time (s) ..................................... : 
Sample 3 burning time (s) ..................................... : 
A.2 Flammability test for fire enclosures of movable equipment having a total mass N/A
not exceeding 18 kg, and for material and components located inside fire
enclosures (see 4.7.3.2 and 4.7.3.4)
A.2.1 Samples, material .................................................. : 
Wall thickness (mm) .............................................. : 
A.2.2 Conditioning of samples; temperature (°C) .......... : N/A
A.2.3 Mounting of samples ............................................ : N/A
A.2.4 Test flame (see IEC 60695-11-4) N/A
Flame A, B or C .................................................... : 
A.2.5 Test procedure N/A
A.2.6 Compliance criteria N/A
Sample 1 burning time (s) ..................................... : 
Sample 2 burning time (s) ..................................... : 
Sample 3 burning time (s) ..................................... : 
A.2.7 Alternative test acc. to IEC 60695-11-5, cl. 5 and 9 N/A
Sample 1 burning time (s) ..................................... : 
Sample 2 burning time (s) ..................................... : 
Sample 3 burning time (s) ..................................... : 

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 27 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

A.3 Hot flaming oil test (see 4.6.2) N/A


A.3.1 Mounting of samples N/A
A.3.2 Test procedure N/A
A.3.3 Compliance criterion N/A

B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and N/A
5.3.2)
B.1 General requirements N/A
Position ................................................................. : 
Manufacturer ........................................................ : 
Type ...................................................................... : 
Rated values ....................................................... : 
B.2 Test conditions N/A
B.3 Maximum temperatures (see appended table 5.3) N/A
B.4 Running overload test (see appended table 5.3) N/A
B.5 Locked-rotor overload test N/A
Test duration (days) ............................................. : 
Electric strength test: test voltage (V) .................. : 
B.6 Running overload test for d.c. motors in N/A
secondary circuits
B.6.1 General N/A
B.6.2 Test procedure N/A
B.6.3 Alternative test procedure N/A
B.6.4 Electric strength test; test voltage (V) .................. : N/A
B.7 Locked-rotor overload test for d.c. motors in N/A
secondary circuits
B.7.1 General N/A
B.7.2 Test procedure N/A
B.7.3 Alternative test procedure N/A
B.7.4 Electric strength test; test voltage (V) ................. : N/A
B.8 Test for motors with capacitors (see appended table 5.3) N/A
B.9 Test for three-phase motors (see appended table 5.3) N/A
B.10 Test for series motors N/A
Operating voltage (V) ........................................... : 

C ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) P

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 28 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Position ................................................................. : T1 (In the complete power 


supply unit)
Manufacturer ........................................................ : See table 1.5.1 
Type ...................................................................... : See table 1.5.1 
Rated values ....................................................... : See table 1.5.1 
Method of protection..............................................: Electronic protection 
C.1 Overload test (see appended table 5.3) P
C.2 Insulation (see appended tables 5.2 and P
C2)
Protection from displacement of windings.............: By bobbin and insulation tape P

D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS P


(see 5.1.4)
D.1 Measuring instrument P
D.2 Alternative measuring instrument N/A

E ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13) N/A

F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES P


(see 2.10 and Annex G)

G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM N/A


CLEARANCES
G.1 Clearances N/A
G.1.1 General N/A
G.1.2 Summary of the procedure for determining N/A
minimum clearances
G.2 Determination of mains transient voltage (V) N/A
G.2.1 AC mains supply .................................................. : N/A
G.2.2 Earthed d.c. mains supplies ................................. : N/A
G.2.3 Unearthed d.c. mains supplies ............................. : N/A
G.2.4 Battery operation .................................................. : N/A
G.3 Determination of telecommunication network N/A
transient voltage (V) ...........................................:
G.4 Determination of required withstand voltage (V) N/A
G.4.1 Mains transients and internal repetitive peaks ..... : N/A
G.4.2 Transients from telecommunication networks ...... : N/A
G.4.3 Combination of transients N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 29 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

G.4.4 Transients from cable distribution systems N/A


G.5 Measurement of transient voltages (V) N/A
a) Transients from a mains supply N/A
For an a.c. mains supply N/A
For a d.c. mains supply N/A
b) Transients from a telecommunication network N/A
G.6 Determination of minimum clearances ............: N/A

H ANNEX H, IONIZING RADIATION (see 4.3.13) N/A

J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) N/A


Metal(s) used ........................................................ : 

K ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8) N/A


K.1 Making and breaking capacity N/A
K.2 Thermostat reliability; operating voltage (V) ......... : N/A
K.3 Thermostat endurance test; operating voltage (V) N/A
............................................................................... :
K.4 Temperature limiter endurance; operating voltage N/A
(V) ......................................................................... :
K.5 Thermal cut-out reliability N/A
K.6 Stability of operation (see appended table 5.3) N/A

L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL P


BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
L.1 Typewriters N/A
L.2 Adding machines and cash registers N/A
L.3 Erasers N/A
L.4 Pencil sharpeners N/A
L.5 Duplicators and copy machines N/A
L.6 Motor-operated files N/A
L.7 Other business equipment P

M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N/A


M.1 Introduction N/A
M.2 Method A N/A
M.3 Method B N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 30 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

M.3.1 Ringing signal N/A


M.3.1.1 Frequency (Hz) ..................................................... : 
M.3.1.2 Voltage (V) ........................................................... : 
M.3.1.3 Cadence; time (s), voltage (V) ............................. : 
M.3.1.4 Single fault current (mA) ....................................... : 
M.3.2 Tripping device and monitoring voltage ............... : N/A
M.3.2.1 Conditions for use of a tripping device or a N/A
monitoring voltage
M.3.2.2 Tripping device N/A
M.3.2.3 Monitoring voltage (V) .......................................... : N/A

N ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1, N/A
7.3.2, 7.4.3 and Clause G.5)
N.1 ITU-T impulse test generators N/A
N.2 IEC 60065 impulse test generator N/A

P ANNEX P, NORMATIVE REFERENCES 

Q ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1) N/A


- Preferred climatic categories ............................. : N/A
- Maximum continuous voltage ............................ : N/A
- Combination pulse current ................................. : N/A
Body of the VDR N/A
Test according to IEC60695-11-5.........................:
Body of the VDR. N/A
Flammability class of material ( min V-1)..............:

R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL N/A


PROGRAMMES
R.1 Minimum separation distances for unpopulated N/A
coated printed boards (see 2.10.6.2)
R.2 Reduced clearances (see 2.10.3) N/A

S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) N/A


S.1 Test equipment N/A
S.2 Test procedure N/A
S.3 Examples of waveforms during impulse testing N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 31 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER N/A


(see 1.1.2)

U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED P


INSULATION (see 2.10.5.4)
Approved TIW used 

V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) P


V.1 Introduction P
V.2 TN power distribution systems P

W ANNEX W, SUMMATION OF TOUCH CURRENTS N/A


W.1 Touch current from electronic circuits N/A
W.1.1 Floating circuits N/A
W.1.2 Earthed circuits N/A
W.2 Interconnection of several equipments N/A
W.2.1 Isolation N/A
W.2.2 Common return, isolated from earth N/A
W.2.3 Common return, connected to protective earth N/A

X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause P


C.1)
X.1 Determination of maximum input current P
X.2 Overload test procedure P

Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) N/A


Y.1 Test apparatus ..................................................... : N/A
Y.2 Mounting of test samples ..................................... : N/A
Y.3 Carbon-arc light-exposure apparatus .................. : N/A
Y.4 Xenon-arc light exposure apparatus .................... : N/A

Z ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2) P

AA ANNEX AA, MANDREL TEST (see 2.10.5.8) N/A

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 32 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

BB ANNEX BB, CHANGES IN THE SECOND EDITION 

CC ANNEX CC, Evaluation of integrated circuit (IC) current limiters N/A


CC.1 General N/A
CC.2 Test program 1……………………………………….: N/A
CC.3 Test program 2……………………………………….: N/A
CC.4 Test program 3.....................................................: N/A
CC.5 Compliance...........................................................: N/A

DD ANNEX DD, Requirements for the mounting means of rack-mounted N/A


equipment
DD.1 General N/A
DD.2 Mechanical strength test, variable N………………..: N/A
DD.3 Mechanical strength test, 250N, including end N/A
stops……………………………………………………:
DD.4 Compliance…………………………………………….: N/A

EE ANNEX EE, Household and home/office document/media shredders N/A


EE.1 General N/A
EE.2 Markings and instructions N/A
Use of markings or symbols…………………………: N/A
Information of user instructions, maintenance and/or N/A
servicing instructions…………………………:
EE.3 Inadvertent reactivation test…………………………: N/A
EE.4 Disconnection of power to hazardous moving parts: N/A
Use of markings or symbols…………………………: N/A
EE.5 Protection against hazardous moving parts N/A
Test with test finger (Figure 2A) ……………………: N/A
Test with wedge probe (Figure EE1 and EE2) ……: N/A

1.5.1 TABLE: List of critical components P


Object/part No. Manufacturer/ Type/model Technical data Standard Mark(s) of
1
trademark (Edition / year) conformity )
Plastic Sabic Innovative 945(GG) PC, 94V-0, UL 94 UL E45329
Enclosure Plastics B V 120°C, Min.
thickness:
1,9mm
Pin Holder Sabic Innovative 945(GG) PC, 94V-0, UL 94 UL E45329
Plastics B V 120°C

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 33 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

PCB Dongguan HX-002A or HX- 94V-0, 130°C UL 94 UL E230194


Huaxing Circuit 003A
Board Factory
(Alternative) Cheng Ho Power 24B-7 94V-0, 130°C, UL 94 UL
Corp
(Alternative) Guang Zhou SX-1 or SX-2 94V-0, 130°C UL 94 UL
Shengxin Electric
Co., Ltd.
(Alternative) Dong Guan New NE5000 or 94V-0, 130°C UL 94 UL
Energy Printed NE5000A
Circuit Board Co.,
Ltd.
(Alternate) Wing Shing YS-3 94V-0, 130°C UL 94 UL
Electronic & PCB
Ltd.
(Alternate) -- -- 94V-0, 130°C UL 94 UL
Fuse Resistor Shenzhen FRKNP-1WS 10Ω, 1W IEC 60950-1 Tested with
(RF1) Kayocota appliance
Electronics Co.,
Ltd
Bridge Diodes -- -- Min. 1A, Min. -- Tested with
(D1-D4) 600V appliance
Storage -- -- 3.3-4.7µF for -- Tested with
capacitor (C1, C1, 4.7-6.8µF appliance
C2) for C2, min.
400V, min.
105°C
Inductor (L1) -- -- 3,3µH±10%, IEC 60950-1 Tested with
rated 130°C appliance
Inductor (L2) -- -- 1,5mH±10%, IEC 60950-1 Tested with
rated 130°C appliance
Heat shrinkable Shenzhen Woer RSFR or RSFR- 600V, 125°C, UL 224 UL
tube Heat-Shrinkable H VW-1
Material Co., Ltd.
(Alternate) -- -- 600V, 125°C, UL 224 UL
VW-1
Output cord Herwell Electric 2468, 2464, AWG24-18, Min. UL 758 UL
Wire Co., Ltd. 1185 80°C,
300VAC,VW-1
(Alternate) Shenzhen MD 2468, 2464, AWG24-18, Min. UL 758 UL
Electric Co., Ltd. 1185 80°C, 300VAC,
VW-1

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 34 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

(Alternate) Yong Hao 2468, 2464, AWG24-18, Min. UL 758 UL


Electrical Industry 1185 80°C, 300VAC,
Co., Ltd. VW-1
(Alternate) Huizhou 2468, 2464, AWG24-18, Min. UL 758 UL
Guangfeng 1185 80°C, 300VAC,
Plastic Produce VW-1
Co., Ltd.
(Alternate) Xinya Electronic 2468, 2464, AWG24-18, Min. UL 758 UL
Co., Ltd. 1185 80°C, 300VAC,
VW-1
(Alternate) Yixiang Electric 2468, 2464, AWG24-18, Min. UL 758 UL
Wire & Cable Co., 1185 80°C, 300VAC,
Ltd. VW-1
(Alternate) -- 2468, 2464, AWG24-18, Min. UL 758 UL
1185 80°C, min.
300VAC, VW-1
(Alternate) -- -- AWG24-18, Min. UL 758 UL
80°C, Min.
300V, VW-1
Plastic Chang Chun 4130(100%Virgi PBT, 94V-0, UL 94 UL E59481
material (for Plastics Co., Ltd. n) (a)(b) 120°C
support
transformer
seconary
pins)
Transformer (T1) Shenzhen Mass T005 A 0001 for Core: EE13, IEC 60950-1 Tested with
Power Electronic output 3,6-8,0V Class B appliance
Limited models;
T005 A 0002 for
output 8,1-
12,0V models.
Material used in transformer T1, L1, L2:
- Bobbin (for SUMITOMO PM-9820 Phenolic, 94V-0, UL 94 UL E41429
T1) BAKELITE 150°C
-Magnet wire Shantou UEW/130 MW75, 130°C UL 1446 UL
(for T1, L1, Shengang
L2) Electrical
Industrial Co.,
Ltd.
(Alternate) Tai-I Electric Wire UEW MW75, 130°C UL 1446 UL
& Cable Co., Ltd.
(Alternate) Pacific Electric DD-NYU MW28C, 130°C UL 1446 UL
Wire & Cable Co.,
Ltd.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 35 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

(Alternate) Feng Ching Metal *UEW MW75-C, 130°C UL 1446 UL


Corp
(Alternate) Huizhou Golden XUEW MW75C, 130°C UL 1446 UL
Ocean Magnet
Wire Factory
(Alternate) -- -- 130°C UL 1446 UL
- Insulation tape Symbio Inc 35660Y*(%) 130°C UL 510 UL
(for T1)
(Alternate) Jingjiang Yahua 130°C UL 510 UL
Pressure
CT, PZ
Sensitive Glue
Co., Ltd.
(Alternate) 3M Company 1350F-1 130°C UL 510 UL
Electrical Markets
Div (EMD)
-Triple insulation Totoku Electric TIW-2 Reinforced IEC 60950-1 VDE
wire (for T1) Co., Ltd. Insulation, Class
B
(Alternate) Furukawa Electric TEX-E Reinforced IEC 60950-1 VDE
Co., Ltd. Insulation, Class
B
(Alternate) Young Chang STW-B Reinforced IEC 60950-1 VDE
Silicone Co., Ltd. Insulation, Class
B
(Alternate) Hoi Luen THL-B Reinforced IEC 60950-1 VDE
Electrical Mfr Co., Insulation, Class
Ltd. B
(Alternate) Feng Ching Metal FTIW Reinforced IEC 60950-1 TUV PS
Corp Insulation, Class
B
(Alternate) Dah Jin TLW-B Reinforced IEC 60950-1 VDE
Technology Insulation, Class
Co., Ltd. B
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance. See OD-CB2039.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 36 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1.5.1 TABLE: Opto Electronic Devices N/A


Manufacturer ............................................... :

Type............................................................. :

Separately tested ........................................ :


Bridging insulation ....................................... :
External creepage distance ......................... :

Internal creepage distance .......................... :

Distance through insulation ......................... :

Tested under the following conditions ......... :


Input............................................................. : --
Output .......................................................... : --
supplementary information

1.6.2 TABLE: Electrical data (in normal conditions) P


U (V) I (A) Irated (A) P (W) Fuse # Ifuse (A) Condition/status
For model: SCF0500100E1BA
90V/50Hz 0.130 -- 7.30 RF1 0.130 At rated output load
90V/60Hz 0.131 -- 7.30 RF1 0.131 At rated output load
100V/50Hz 0.120 0.15 7.22 RF1 0.120 At rated output load
100V/60Hz 0.121 0.15 7.21 RF1 0.121 At rated output load
240V/50Hz 0.065 0.15 7.12 RF1 0.065 At rated output load
240V/60Hz 0.065 0.15 7.12 RF1 0.065 At rated output load
264V/50Hz 0.061 -- 7.18 RF1 0.061 At rated output load
264V/60Hz 0.060 -- 7.18 RF1 0.060 At rated output load
For model: SCF0810062E1BA
90V/50Hz 0.123 -- 6.91 RF1 0.123 At rated output load
90V/60Hz 0.124 -- 6.90 RF1 0.124 At rated output load
100V/50Hz 0.113 0.15 6.82 RF1 0.113 At rated output load
100V/60Hz 0.114 0.15 6.82 RF1 0.114 At rated output load
240V/50Hz 0.062 0.15 6.72 RF1 0.062 At rated output load

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 37 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

240V/60Hz 0.061 0.15 6.72 RF1 0.061 At rated output load


264V/50Hz 0.058 -- 6.77 RF1 0.058 At rated output load
264V/60Hz 0.057 -- 6.76 RF1 0.057 At rated output load
For model: SCF1200042E1BA
90V/50Hz 0.123 -- 6.83 RF1 0.123 At rated output load
90V/60Hz 0.125 -- 6.83 RF1 0.125 At rated output load
100V/50Hz 0.112 0.15 6.75 RF1 0.112 At rated output load
100V/60Hz 0.113 0.15 6.75 RF1 0.113 At rated output load
240V/50Hz 0.061 0.15 6.71 RF1 0.061 At rated output load
240V/60Hz 0.061 0.15 6.68 RF1 0.061 At rated output load
264V/50Hz 0.057 -- 6.74 RF1 0.057 At rated output load
264V/60Hz 0.057 -- 6.75 RF1 0.057 At rated output load
Supplementary information: --

2.1.1.5 c) TABLE: max. V, A, VA test P


1)

Voltage (rated) Current (rated) Voltage (max.) Current (max.) VA (max.)


(V) (A) (V) (A) (VA)
For model: SCF0500100E1BA
5.0 1.00 5.15 1.34 6.55
For model: SCF0810062E1BA
8.1 0.62 8.09 0.84 6.61
For model: SCF1200042E1BA
12.0 0.42 12.06 0.83 8.95
supplementary information:
Tested under AC 264V, 50Hz

2.1.1.5 c) TABLE: stored energy N/A


2)

Capacitance C (µF) Voltage U (V) Energy E (J)


-- -- --
-- -- --
supplementary information: --

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 38 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.2 TABLE: evaluation of voltage limiting components in SELV circuits P


Component (measured between) max. voltage (V) Voltage Limiting Components
(normal operation)
V peak V d.c.
For model: SCF0500100E1BA
T1 secondary winding Pin Ta-Pin Tb 25.6 -- --
“”
D7 - - pinTb -- 5.22 D7
For model: SCF0810062E1BA NBS30D240150HE
T1 secondary winding Pin Ta-Pin Tb 40.0 -- --
“”
D7 - - pinTb -- 8.12 D7
For model: SCF1200042E1BA
T1 secondary winding Pin Ta-Pin Tb 40.0 -- --
“”
D7 - - pinTb -- 12.30 D7

Fault test performed on voltage limiting Voltage measured (V) in SELV circuits
components (V peak or V d.c.)
D7 short-circuit for model SCF0500100E1BA 0V (unit shut down immediately)
D7 short-circuit for model SCF0810062E1BA 0V (unit shut down immediately)
D7 short-circuit for model SCF1200042E1BA 0V (unit shut down immediately)
supplementary information:
Tested under AC 264V, 50Hz

2.5 TABLE: Limited power sources P


Circuit output tested:
Note: Measured Uoc (V) with all load circuits disconnected:
Components Sample Uoc (V) Isc (A) VA
No.
Meas. Limit Meas. Limit
For model: SCF0500100E1BA
Normal condition 1 5.15 1.34 8 6.55 100
0 (unit shut 0 (unit shut 0 (unit shut
Single fault: R8 Sc 1 down down 8 down 100
immediately) immediately) immediately)

Single fault: 0 (unit shut 0 (unit shut 0 (unit shut


2 down down 8 down 100
R9 Sc immediately) immediately) immediately)
Single fault: 0 (RF1 open 0 (RF1 open 0 (RF1 open
2 8 100
R11 Sc immediately) immediately) immediately)

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 39 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

For model: SCF0810062E1BA


Normal condition 1 8.09 0.84 8 6.61 100
0 (unit shut 0 (unit shut 0 (unit shut
Single fault: R8 Sc 1 down down 8 down 100
immediately) immediately) immediately)

Single fault: 0 (unit shut 0 (unit shut 0 (unit shut


2 down down 8 down 100
R9 Sc immediately) immediately) immediately)
Single fault: 0 (RF1 open 0 (RF1 open 0 (RF1 open
2 8 100
R11 Sc immediately) immediately) immediately)
For model: SCF1200042E1BA
Normal condition 1 12.06 0.83 8 8.95 100
0 (unit shut 0 (unit shut 0 (unit shut
Single fault: R8 Sc 1 down down 8 down 100
immediately) immediately) immediately)

Single fault: 0 (unit shut 0 (unit shut 0 (unit shut


2 down down 8 down 100
R9 Sc immediately) immediately) immediately)
Single fault: 0 (RF1 open 0 (RF1 open 0 (RF1 open
2 8 100
R11 Sc immediately) immediately) immediately)
supplementary information:
Sc=Short circuit, Oc=Open circuit

2.10.2 Table: working voltage measurement P

Location RMS voltage (V) Peak voltage (V) Comments


For model: SCF0500100E1BA

T1 Pin1- PinTa 178 368

T1 Pin2- PinTa 206 524

T1 Pin3- PinTa 185 356

T1 Pin4- PinTa 186 384

T1 Pin1- PinTb 178 344

T1 Pin2- PinTb 211 536 Max. Vrms and Max. Vpeak

T1 Pin3- PinTb 186 352

T1 Pin4- PinTb 189 412


For model: SCF1200042E1BA

T1 Pin1- PinTa 178 376

T1 Pin2- PinTa 209 524

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 40 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

T1 Pin3- PinTa 187 368

T1 Pin4- PinTa 186 368

T1 Pin1- PinTb 177 344

T1 Pin2- PinTb 214 544 Max. Vrms and Max. Vpeak

T1 Pin3- PinTb 186 356

T1 Pin4- PinTb 188 408


supplementary information:
tested under 240Va.c., 60Hz.

2.10.3 and TABLE: Clearance and creepage distance measurements P


2.10.4
Clearance (cl) and creepage U peak U r.m.s. Required cl cl Required cr cr
distance (cr) at/of/between: (V) (V) (mm) (mm) (mm) (mm)
Functional:
Line and Neutral before RF1
<420 240 1.5 3.2 2.5 3.2
(FI)
L to circuit after RF1 (FI) <420 240
Basic/supplementary:
Two terminals of RF11 (BI) <420 240 2.0 4.9 2.5 4.9
Reinforced:
Live parts and outer surface <420 240 4.0 6.0 5.0 6.0
Primary winding/core of T1 544 214 4.4 12.9 5.0 12.9
and secondary pins
Primary Winding/core of T1 544 214 4.4 5.7 5.0 5.7
and secondary components
D7
Primary Winding/core of T1 544 214 4.4 5.0 5.0 7.2
and secondary components
C7
Primary Winding/core of T1 544 214 4.4 5.6 5.0 10.0
and secondary components
L3
Pri. and sec. track on PCB 544 214 4.4 7.5 5.0 7.5
Supplementary information:
1. The core of T1 is considered as primary hazardous live part.
2. FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.
3. The secondary winding wire of T1 is approved reinforced insulation wires.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 41 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.10.5 TABLE: Distance through insulation measurements P


Distance through insulation (DTI) at/of: U peak U rms Test Required DTI DTI
(V) (V) voltage (mm) (mm)
(V)
Thickness of enclosure (RI) <420 240 AC3000 ≥ 0.4 Min. 1.9
Plastic material (for support transformer seconary 568 256 AC3000 ≥ 0,4 1)
pins) (RI)
Supplementary information:
1) see appended table1.5.1
RI: Reinforced insulation.

4.3.8 TABLE: Batteries N/A


The tests of 4.3.8 are applicable only when appropriate battery -- --
data is not available
Is it possible to install the battery in a reverse polarity position? -- --
Non-rechargeable batteries Rechargeable batteries
Discharging Un- Charging Discharging Reversed charging
Meas. Manuf. intentional Meas. Manuf. Meas. Manuf. Meas. Manuf.
current Specs. charging current Specs. current Specs. current Specs.
Max. -- -- -- -- -- -- -- -- --
current
during
normal
condition
Max. -- -- -- -- -- -- -- -- --
current
during
fault
condition

Test results: Verdict


- Chemical leaks --
- Explosion of the battery --
- Emission of flame or expulsion of molten metal --
- Electric strength tests of equipment after completion of tests --
Supplementary information: --

4.3.8 TABLE: Batteries N/A


Battery category .......................................... : (Lithium, NiMh, NiCad, Lithium Ion …)
Manufacturer ............................................... : --
Type / model ................................................ : --

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 42 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Voltage ........................................................ : --
Capacity....................................................... : --
Tested and Certified by (incl. Ref. No.) ....... : --
Circuit protection diagram: --

MARKINGS AND INSTRUCTIONS (1.7.13 )


Location of replaceable battery --
Language(s) …………………………………….: --
Close to the battery …………………………….: --
In the servicing instructions ……………………: --
In the operating instructions …………………..: --

4.5 TABLE: Thermal requirements P


Supply voltage (V) .......................... : A: 90V/60Hz Horizontal; 
B: 90V/60Hz Vertical;
C: 264V/50Hz Horizontal;
D: 294V/50Hz Vertical.
Ambient Tmin (°C) ............................ : 45.0 45.0 45.0 45.0 
Ambient Tmax (°C) ........................... : 45.0 45.0 45.0 45.0 
Maximum measured temperature T of part/at ....: T (°C) Allowed
Tmax (°C)
For model: SCF0500100E1BA A B C D --

RF1 body 82.0 87.6 66.9 70.3 Ref.


PCB under D4 80.5 85.3 69.2 72.1 130
C1 76.3 80.1 69.3 71.5 105
C2 82.2 85.4 75.3 76.9 105
L1 81.2 85.3 74.4 77.0 120
L2 68.8 70.6 65.2 65.8 120
PCB near U1 104.5 106.5 100.0 100.5 130
T1 winding 102.5 102.4 102.0 100.0 110
T1 core 99.5 100.0 98.4 97.5 Ref.
PCB under D7 102.0 102.9 104.4 103.4 130
L3 84.2 86.3 85.4 85.5 120
C7 87.6 89.5 88.2 88.3 105

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 43 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Output wire 66.0 68.1 67.3 67.2 80


Enclosure inside (top T1) 78.7 80.1 79.3 79.1 Cl 4.2.7
Enclosure inside (side T1) 75.8 74.7 76.9 73.7 Cl 4.2.7
Enclosure outside (top T1) 70.3 71.9 70.8 70.3 95
Enclosure outside (side T1) 69.6 67.6 69.9 66.2 95
For model: SCF0810062E1BA A B C D --

RF1 body 76.4 81.9 64.2 67.9 Ref.


PCB under D4 77.1 80.5 69.4 71.9 130
C1 72.2 74.8 67.3 68.5 105
C2 77.2 79.8 74.4 76.0 105
L1 76.2 79.3 70.9 73.1 120
L2 77.4 79.3 70.9 71.6 120
PCB near U1 92.5 93.9 91.6 91.6 130
T1 winding 102.0 102.5 104.9 103.9 110
T1 core 99.5 99.8 102.9 101.7 Ref.
PCB under D7 95.2 96.6 100.4 99.7 130
L3 79.3 81.4 82.3 82.4 120
C7 75.8 77.3 77.4 77.1 105
Output wire 61.2 63.5 63.4 63.2 80
Enclosure inside (top T1) 82.9 81.4 85.5 82.5 Cl 4.2.7
Enclosure inside (side T1) 73.6 71.8 76.3 72.6 Cl 4.2.7
Enclosure outside (top T1) 72.1 70.4 74.2 69.8 95
Enclosure outside (side T1) 61.0 59.6 63.6 59.8 95
For model: SCF1200042E1BA A B C D --

RF1 body 77.8 83.4 65.4 68.3 Ref.


PCB under D4 75.7 81.0 66.7 69.6 130
C1 75.2 79.2 70.2 72.0 105
C2 78.0 81.7 73.6 75.2 105
L1 77.7 82.1 72.9 75.4 120
L2 73.6 77.1 68.8 70.1 120
PCB near U1 100.7 104.2 98.9 99.8 130
T1 winding 97.8 99.5 100.0 99.1 110
T1 core 93.7 96.1 96.3 96.0 Ref.
PCB under D7 94.4 96.8 98.9 98.4 130
L3 79.1 82.3 81.7 82.6 120
C7 80.3 83.0 82.0 82.7 105

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 44 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Output wire 60.1 63.1 61.8 62.8 80


Enclosure inside (top T1) 77.5 80.1 79.2 79.6 Cl 4.2.7
Enclosure inside (side T1) 79.3 79.6 81.4 78.8 Cl 4.2.7
Enclosure outside (top T1) 68.2 70.8 69.2 69.8 95
Enclosure outside (side T1) 69.9 70.0 71.9 69.0 95
Supplementary information:
Temperature T of winding: t1 (°C) R1 (Ω) t2 (°C) R2 (Ω) T (°C) Allowed Insulation
Tmax (°C) class
-- -- -- -- -- -- -- --
Supplementary information:
1. Thermocouple method used.
2. Tma is 45°C Max. The above data are adjusted at Tma=45°C.
3. Horizontal means the adaptor is plugged into horizontal socket-outlet; Vertical means the adaptor is
plugged into vertical wall socket-outlet.

4.5.5 TABLE: Ball pressure test of thermoplastic parts P


Allowed impression diameter (mm) .....................: ≤ 2 mm 
Part Test temperature Impression diameter
(°C) (mm)
Plug holder 125 1.1
Supplementary information:
The bobbin material for T1 is phenolic, accecpted without test.

4.7 TABLE: Resistance to fire P


Part Manufacturer of Type of material Thickness Flammability Evidence
material (mm) class
Plastic Enclosure SABIC 945(GG) Min. V-0 UL E45329
INNOVATIVE 1.9mm
PLASTICS B V
Supplementary information: See table 1.5.1.

5.1 TABLE: touch current measurement P

Measured between: Measured Limit Comments/conditions


(mA) (mA)
Between live parts and output 0.01 0.25 264V/60Hz, Figure 5A used
terminal
Between live parts and output 0.005 0.25 264V/60Hz, Figure 5A used
accessible enclosure with foil
supplementary information: --

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 45 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

5.2 TABLE: Electric strength tests, impulse tests and voltage surge tests P
Test voltage applied between: Voltage shape Test voltage Breakdo
(AC, DC, (V) wn
impulse, surge) Yes / No
Functional:
Between L and N before RF1 (RF1 disconnected) AC 1500 No
Basic:
Two terminals of fuse resistor RF1 ( RF1 open condition) AC 1500 No
Reinforced:
Between live parts and output terminal DC 4242 No
Between live parts and accessible enclosure with foil AC 3000 No
T1 primary and secondary AC 3000 No
T1 secondary and core AC 3000 No
Supplementary information:--

5.3 TABLE: Fault condition tests P


Ambient temperature (°C) ................................... : Same as below 
Power source for EUT: Manufacturer, model/type, -- 
output rating ........................................................ :
Component Fault Supply Test Fuse # Fuse current Observation
No. voltage time (A)
(V)
For model: SCF1200042E1BA
D1 S-C 264Va.c. 1s RF1 -- RF1 open immediately, no hazard.
C1 S-C 264Va.c. 1s RF1 -- RF1 open immediately, no hazard.
C2 S-C 264Va.c. 1s RF1 -- RF1 open immediately, no hazard.
T1 pin1-pin2
S-C 264Va.c. 10min RF1 →
0.057 0.022 Unit shut down immediately, no
damaged, no hazard.
T1 pin3-pin4
S-C 264Va.c. 10min RF1 0.057→0.020 Unit shut down immediately, no
damaged, no hazard.
T1 pinTa-pinTb
S-C 264Va.c. 10min RF1 0.057→0.021 Unit shut down immediately, no
damaged, no hazard.
U1 pin1-pin2
S-C 264Va.c. 10min RF1 0.057→0.010 Unit shut down immediately, no
damaged, no hazard.
U1 pin1-pin3
S-C 264Va.c. 10min RF1 0.057→0.057 Similar with normal operation, no
hazards.
U1 pin1-pin4
S-C 264Va.c. 10min RF1 0.057→0.005 Unit shut down immediately, no
damaged, no hazard.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 46 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

U1 pin1-pin5
S-C 264Va.c. 10min RF1

0.057 0.037 Component U1 damaged, repeat
three times as the same results, no
hazard.
U1 pin3-pin4
S-C 264Va.c. 10min RF1 →
0.057 0.010 Unit shut down immediately, no
damaged, no hazard.
U1 pin3-pin5 S-C 264Va.c. 1s RF1 -- RF1 open immediately, no hazard.
U1 pin4-pin5 RF1 open immediately, component
S-C 264Va.c. 1s RF1 --
U1 damaged, no hazard.
U1 pin5-pin7 S-C 264Va.c. 1s RF1 -- RF1 open immediately, no hazard.
R8
S-C 264Va.c. 10 min RF1

0.057 0.031 Component U1 damaged, repeat
three times as the same results, no
hazard.
R9
S-C 264Va.c. 10 min RF1

0.057 0.006 Component U1 damaged, repeat
three times as the same results, no
hazard.
R11 RF1 open immediately, component
S-C 264Va.c. 1s RF1 --
U1 damaged, no hazard.
D7
S-C 264Va.c. 10 min RF1 →
0.057 0.009 Unit shut down immediately, no
damaged, no hazard.
Output “V+” to
S-C 264Va.c. 10 min RF1 0.057→0.010 Unit shut down immediately, no
“V-” damaged, no hazard.
0.057→ Output overload up to 0.71A, then
0.065→ unit shut down,
Output “V+” to
O-L 264Va.c.
3hrs
RF1 0.072→ Max. Temperature of T1 winding:
“V-” 54mins 0.080→ 125.5°C, Max. Temperature of T1
0.010 core: 120.0°C, no damage, no
hazards.
For model: SCF0500100E1BA
Output “V+” to
S-C 264Va.c. 10 min RF1 →
0.061 0.009 Unit shut down immediately, no
“V-” damaged, no hazard.
0.061 → Output overload up to 1.22A, then
0.066 → unit shut down,
Output “V+” to
“V-”
O-L 264Va.c.
4hrs
RF1 0.068 → Max. Temperature of T1 winding:
116.4°C, Max. Temperature of T1
1mins 0.017
core: 111.6°C, no damage, no
hazards.
For model: SCF0810062E1BA
Output “V+” to
S-C 264Va.c. 10 min RF1 →
0.058 0.010 Unit shut down immediately, no
“V-” damaged, no hazard.
0.058 → Output overload up to 0.8A, then unit
0.063 → shut down,
Output “V+” to
“V-”
O-L 264Va.c.
4hrs
RF1 0.070 → Max. Temperature of T1 winding:
127.2°C, Max. Temperature of T1
1mins 0.010
core: 124.6°C, no damaged, no
hazard.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 47 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Supplementary information:
1. “Sc” means short-circuited test, “Oc” means open-circuited test, “O-L” means overload test; Uo means
output voltage at normal load, Uoc means output voltage without load. (Unit: V d.c.)
2. Thermocouple method was used.
3. Tma is 45°C Max. The above data are corrected at Tma=45°C.
4. Limited temperature for T1 winding: 165°C (Class B).
5. The fuse resistor RF1 operated fault tests were repeated 10 times (all source of fuse resistor were
considered, detailed fuse resistor information see appended table 1.5.1), the test results are same, the fuse
resistor body no explode and no hazards.
6. All tests were repeated in AC 90V/60Hz. Same result generated.

C.2 TABLE: transformers P


Loc. Tested insulation Working Working Required Required Required Required
voltage voltage electric clearance creepage distance thr.
peak / V rms / V strength / mm distance / insul.
mm
(2.10.2) (2.10.2) (5.2) (2.10.3) (2.10.4) (2.10.5)
Pri. Reinforced 544 214 AC 4.4 5.0 Yes
Winding to insulation 3000V
Sec.
winding/pin
Sec. Reinforced 544 214 AC 4.4 5.0 Yes
Winding/pi insulation 3000V
n to Iron
core
Loc. Tested insulation Test Measured Measured Measured
voltage/ V clearance creepage distance thr.
/ mm dist./ mm insul. / mm;
number of
layers
Pri. Reinforced insulation AC 12.9 12.9 Triple
Winding to 3000V insulation
Sec. wire used as
winding/pin secondary
winding
Sec. Reinforced insulation AC 12.9 12.9 Triple
Winding/pi 3000V insulation
n to Iron wire used as
core secondary
winding
supplementary information:--
T1 iron core is considered as primary hazardous live part.

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 48 of 48
Report No.: 085-110044304-000
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

C.2 TABLE: transformers P


1. Outlook Drawing (Unit: mm)

2. Schematic:

3. Section Drawing:

4. Winding Specification:

END OF REPORT

TRF No. IEC60950_1F TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 1 of 71
Report No.: 085-110044304-000

Attachment No. 1
nd
National and Group Differences for IEC 60950-1 2 Ed. +A1:2009+A2:2013 as per CB
Bulletin
National Differences covered by this report
Country CENELEC National Base standard National standard Tested
Group differ. differ.
(see separate
attachment)

AT Austria Yes - IEC 60950-1 ed2 + EN 60950-1/A2:2013 Yes


A1+ A2
AU Australia - Yes IEC 60950-1 ed2+ A1 AS/NZS 60950.1:2011/Amdt Yes
1:2012
Argentina - - IEC 60950-1 ed2+ A1 - Yes
Belarus - - IEC 60950-1 ed2 + A1 - Yes
BE Belgium Yes - IEC 60950-1 ed2 + EN 60950-1/A2:2013 Yes
A1+ A2
Brazil - - IEC 60950-1 ed2 + A1 - Yes
CA Canada - Yes IEC 60950-1 ed2 + A1 CAN/CSA-C22.2 No. 60950- Yes
1/A1:2011
CH Switzerland Yes - IEC 60950-1 ed2+ A1 SN EN 60950-1/A1:2010 Yes
CN China - Yes IEC 60950-1(ed.2) GB4943.1-2011 Yes
CZ Czech Republic Yes - IEC 60950-1 ed2 + A1 EN 60950-1/A1:2010 Yes
DE Germany Yes Yes IEC 60950-1 ed2 + EN 60950-1/A2:2013; VDE Yes
A1+ A2 0805-1:2011-01
DK Denmark Yes Yes IEC 60950-1 ed2 + DS/EN 60950-1/A2:2013 Yes
A1+A2
ES Spain Yes Yes IEC 60950-1 ed2 UNE EN 60950-1 Yes

FI Finland Yes Yes IEC 60950-1 ed2 + A1 EN 60950-1/A1:2010 Yes

FR France Yes - IEC 60950-1 ed2 + EN 60950-1/A2:2013 Yes


A1+ A2
GB United Kingdom Yes Yes IEC 60950-1 ed2 + BS EN 60950-1/A2:2013 Yes
A1+ A2
HU Hungary Yes - IEC 60950-1 ed2 + EN 60950-1/A1:2010 Yes
A1+ A2
IE Ireland Yes Yes IEC 60950-1 ed2 EN 60950-1 Yes

IL Israel - Yes IEC 60950-1 ed2 + A1 SI 60950-1:2012 Yes

IN India - - IEC 60950-1 ed2 + A1 - Yes

IT Italy Yes - IEC 60950-1 ed2 + EN 60950-1/A2:2013 Yes


A1+A2
JP Japan - Yes IEC 60950-1 ed1 J60950-1(H26); J3000 (H25) Yes

KR Korea - Yes IEC 60950-1 ed2 + A1 K 60950-1 Yes

MY Malaysia - - IEC 60950-1 ed2 + A1 - -

NO Norway Yes - IEC 60950-1 ed2 + EN 60950-1/A2:2013 Yes


A1+A2
NL Netherlands Yes - IEC 60950-1 ed2 + EN 60950-1/A2:2013 Yes
A1+A2
PL Poland Yes - IEC 60950-1 ed2 + A1 EN 60950-1/A1:2010 Yes

Russian Republic - - IEC 60950-1 ed1 - Yes


Saudi Arabia - - IEC 60950-1 ed2 + A1 - Yes

SE Sweden Yes Yes IEC 60950-1 ed2 + SS-EN60950-1/A2:2013 Yes


A1+A2

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 2 of 71
Report No.: 085-110044304-000

Attachment No. 1
National Differences covered by this report
Country CENELEC National Base standard National standard Tested
Group differ. differ.
(see separate
attachment)

SG Singapore - - IEC 60950-1 ed2 + - -


A1+A2
SI Slovenia Yes - IEC 60950-1 ed2 + A1 SIST EN 60950/A1:2010 Yes

Slovakia - - IEC 60950-1 ed2 + - Yes


A1+A2
SERBIA - - IEC 60950-1 ed2 + - Yes
A1+A2
UA Ukraine - Yes IEC 60950 ed3 DSTU 4113-2001 Yes

US United States of America - Yes IEC 60950-1 ed2 + UL 60950-1 Am.1; Am.2 Yes
A1+A2

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 3 of 71
Report No.: 085-110044304-000

Attachment No. 1

General remarks:
The test results presented in this report relate only to the object tested.

This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.

Throughout this report a point is used as the decimal separator.

See attachment 2 for European Group Differences and National Differences.

Note: Before placing the products in the different countries, the manufacturer must ensure that:

1. Operating Instructions, Ratings Labels and Warnings Labels written in an Accepted or Official Language of
the county in question.
2. The equipment complies with the National Standards and/or Electrical Codes of the country in question.
3. Mains plugs and internal wirings should be assessed to the national standard.
Possible test case verdicts:
- test case does not apply to the test object .................. : N/A
- test object does meet the requirement ....................... : P (Pass)
- test object does not meet the requirement ................. : F (Fail)

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 4 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

AU Australia AU
APPENDIX ZZ 
VARIATIONS TO IEC 60950-1, ED.2.0 (2005)+A1(2009) FOR APPLICATION
IN AUSTRALIA AND NEW ZEALAND
(Normative)
ZZ1 INTRODUCTION 
This Appendix sets out variations and additional requirements to cover issues which
have not been addressed by the International Standard. These variations indicate
national variations for purposes of the IECEE CB System and will be published in the
IECEE CB Bulletin.
ZZ2 VARIATIONS
The following variations apply to the source text.
1.2 Insert the following between ‘person, service’ and P
‘range, rated frequency’:
POTENTIAL IGNITION SOURCE….. …..1.2.12
1.2.12.20 Insert a new Clause 1.2.12.201 after Clause P
1 1.2.12.15 as follows:
1.2.12.201 POTENTIAL IGNITION SOURCE
Possible fault which can start a fire if the open-
circuit voltage measured across an interruption or
faulty contact exceeds a value of 50 V (peak) a.c.
or d.c. and the product of the peak value of this
voltage and the measured r.m.s current under
normal operating conditions exceeds 15 VA.
Such a faulty contact or interruption in an
electrical connection includes those which may
occur in CONDUCTIVE PATTERNS on PRINTED
BOARDS.
NOTE 201 An electronic protection circuit may be
used to prevent such a fault from becoming a
POTENTIAL IGNITION SOURCE.
NOTE 202 This definition is from AS/NZS
60065:2003.
1.5.1 1. Add the following to the end of the first P
paragraph: ‘or the relevant Australian/New
Zealand Standard’.
2. In NOTE 1, add the following after the word
‘standard’: ‘or an Australian/New Zealand
Standard’
1.5.2. Add the following to the end of the first and third P
dash items: ‘or the relevant Australian/New
Zealand Standard’.
3.2.5.1 Modify Table 3B as follows: N/A
1. Delete the first four rows and replace with the
following:

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 5 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

AU Australia AU
N/A
Minimum conductor sizes
RATED CURRENT of equipment AWG or kcmil
Nominal
A [cross-sectional area in
cross-sectional area 2
2 mm ]
mm
see Note 2
a
Over 0.2 up to and including 3 0,5 18 [0,8]

Over 3 up to and including 7.5 0,75 16 [1,3]


b
Over 7.5 up to and including 10 (0,75) 1,00 16 [1,3]
c
Over 10 up to and including 16 1,0) 1,5 14 [2]

2. Delete NOTE 1.
a
3. Delete Footnote and replace with the following:
a
This nominal cross-sectional area is only allowed for Class II appliances if the length of the power
supply cord, measured between the point where the cord, or cord guard, enters the appliance, and
the entry to the plug does not exceed 2 m (0.5 mm2 three-core supply flexible cords are not
permitted; see AS/NZS 3191).
4.1.201 Insert a new Clause 4.1.201 after Clause 4.1 as N/A
follows:
4.1.201 Display devices used for television
purposes
Display devices which may be used for television
purposes, with a mass of 7 kg or more, shall
comply with the requirements for stability and
mechanical hazards, including the additional
stability requirements for television receivers,
specified in AS/NZS 60065.
4.3.6 Delete the third paragraph and replace with the N/A
following:
Equipment with a plug portion, suitable for
insertion into a 10 A 3-pin flat-pin socket-outlet
complying with AS/NZS 3112, shall comply with
the requirements in AS/NZS 3112 for equipment
with integral pins for insertion into socket-outlets.
4.3.13.5 Clause 4.3.13.5 and replace with the following: N/A
1.Add the following after each reference to ‘IEC
60825-1’ : or ‘AS/NZS 60825.1’
2. Add the following after ‘IEC 60825-2’ in line
two of the first paragraph:
‘or AS/NZS 60825.2’
4.7 Add the following new paragraph to the end of the N/A
clause:
‘For alternate tests refer to Clause 4.7.201.’

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 6 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

AU Australia AU
4.7.201 Insert a new Clause 4.7.201 after Clause 4.7.3.6 N/A
as follows:
4.7.201 Resistance to fire – Alternative tests
4.7.201.1 General
Parts of non-metallic material shall be resistant to
ignition and spread of fire.
This requirement does not apply to decorative
trims, knobs and other parts unlikely to be ignited
or to propagate flames originating from inside the
apparatus, or the following:
(a) Components that are contained in an
enclosure having a flammability category
of V-0 according to AS/NZS 60695.11.10
and having openings only for the
connecting wires filling the openings
completely, and for ventilation not
exceeding 1 mm in width regardless of
length.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 7 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

AU Australia AU
(b) The following parts which would N/A
contribute negligible fuel to a fire:
-small mechanical parts, the mass of
which does not exceed 4 g, such as
mounting parts, gears, cams, belts and
bearings;
-small electrical components, such as
capacitors with a volume not exceeding 1
750 mm3, integrated circuits, transistors
and optocoupler packages, if these
components are mounted on material of
flammability category V-1, or better,
according to AS/NZS 60695.11.10.
NOTE In considering how to minimize propagation
of fire and what ‘small parts’ are, account should
be taken of the cumulative effect of small parts
adjacent to each other for the possible effect of
propagating fire from one part to another.
Compliance shall be checked by the tests of
4.7.201.2, 4.7.201.3, 4.7.201.4 and 4.7.201.5.
For the base material of printed boards,
compliance shall be checked by the test of
4.7.201.5. The tests shall be carried out on parts
of non-metallic material which have been removed
from the apparatus. When the glow-wire test is
carried out, the parts shall be placed in the same
orientation as they would be in normal use. These
tests are not carried out on internal wiring.
4.7.201.2 Testing of non-metallic materials Parts
of non-metallic material shall be subject to the
glow-wire test of AS/NZS 60695.2.11 which shall
be carried out at 550°C. Parts for which the glow-
wire test cannot be carried out, such as those
made of soft or foamy material, shall meet the
requirements specified in ISO 9772 for category
FH-3 material. The glow-wire test shall be not
carried out on parts of material classified at least
FH-3 according to ISO 9772 provided that the
sample tested was not thicker than the relevant
part.
4.7.201.3 Testing of insulating materials.
Parts of insulating material supporting
POTENTIAL IGNITION SOURCES shall be
subject to the glow-wire test of AS/NZS
60695.2.11 which shall be carried out at 750°C.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 8 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

AU Australia AU
The test shall be also carried out on other parts of N/A
insulating material which are within a distance of
3mm of the connection.
NOTE Contacts in components such as switch
contacts are considered to be connections.
For parts which withstand the glow-wire test but
produce a flame, other parts above the connection
within the envelope of a vertical cylinder having a
diameter of 20 mm and a height of 50 mm shall
be subjected to the needle-flame test. However,
parts shielded by a barrier which meets the
needle-flame test shall not be tested.
The needle-flame test shall be made in
accordance with AS/NZS 60695.11.5 with the
following modifications:
Clause of AS/NZS 60695.11.5 Change N/A
9 Test procedure
9.2 Application of needle-flame Replace the first paragraph with:
The specimen shall be arranged so
that the flame can be applied to a
vertical or horizontal edge as shown
in the examples of figure 1. If
possible the flame shall be applied
at least 10 mm from a corner
Replace the second paragraph with:
The duration of application of the
±
test flame shall be 30 s 1 s.
9.3 Number of test specimens Replace with:
The test shall be made on one
specimen. If the specimen does not
withstand the test, the test may be
repeated on two further specimens,
both of which shall then withstand
the test.
11 Evaluation of test results Replace with:
The duration of burning (tb) shall
not exceed 30 s. However, for
printed circuit boards, it shall not
exceed 15 s.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 9 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

AU Australia AU
The needle-flame test shall not be carried out on parts of material classified as V-0 or V- N/A
1 according to AS/NZS 60695.11.10, provided that the sample tested was not thicker
than the relevant part.
4.7.201.4 Testing in the event of non-extinguishing material
If parts, other than enclosures, do not withstand the glow wire tests of 4.7.201.3, by
failure to extinguish within 30 s after the removal of the glow-wire tip, the needle-flame
test detailed in 4.7.201.3 shall be made on all parts of non-metallic material which are
within a distance of 50 mm or which are likely to be impinged upon by flame during the
tests of 4.7.201.3. Parts shielded by a separate barrier which meets the needle-flame
test need not be tested.
NOTE 1 - If the enclosure does not withstand the glow-wire test the equipment is
considered to have failed to meet the requirements of Clause 4.7.201 without the need
for consequential testing.
NOTE 2 - If other parts do not withstand the glow-wire test due to ignition of the tissue
paper and if this indicates that burning or glowing particles can fall onto an external
surface underneath the equipment, the equipment is considered to have failed to meet
the requirements of Clause 4.7.201 without the need for consequential testing.
NOTE 3 - Parts likely to be impinged upon by the flame are considered to be those
within the envelope of a vertical cylinder having a radius of 10 mm and a height equal to
the height of the flame, positioned above the point of the material supporting, in contact
with, or in close proximity to, connections.
4.7.201.5 Testing of printed boards
The base material of printed boards shall be subjected to the needle-flame test of
Clause 4.7.201.3. The flame shall be applied to the edge of the board where the heat
sink effect is lowest when the board is positioned as in normal use. The flame shall not
be applied to an edge, consisting of broken perforations, unless the edge is less than 3
mm from a POTENTIAL IGNITION SOURCE.
The test is not carried out if the —
-Printed board does not carry any POTENTIAL IGNITION SOURCE;
-Base material of printed boards, on which the available apparent power at a connection
exceeds 15 VA operating at a voltage exceeding 50 V and equal or less than 400 V
(peak) a.c. or d.c. under normal operating conditions, is of flammability category V-1 or
better according to AS/NZS 60695.11.10, or the printed boards are protected by an
enclosure meeting the flammability category V-0 according to AS/NZS 60695.11.10, or
made of metal, having openings only for connecting wires which fill the openings
completely; or
-Base material of printed boards, on which the available apparatus power at a
connection exceeds 15 VA operating at a voltage exceeding 400 V (peak) a.c. or d.c.
under normal operating conditions, and base material of printed boards supporting spark
gaps which provides protection against overvoltages, is of flammability category V-0
according to AS/NZS 60695.11.10 or the printed boards are contained in a metal
enclosure, having openings only for connecting wires which fill the openings completely.
Compliance shall be determined using the smallest thickness of the material.
NOTE – Available apparent power is the maximum apparent power which can be drawn
from the supplying circuit through a resistive load whose value is chosen to maximise
the apparent power for more than 2 min when the circuit supplied is disconnected.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 10 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

AU Australia AU
6.2.2 For Australia only, delete the first paragraph and N/A
Note, and replace with the following:
In Australia only, compliance with 6.2.2 shall be
checked by the tests of both 6.2.2.1 and 6.2.2.2.
6.2.2.1 For Australia only, delete the first paragraph N/A
including the Note, and replace with the following:
In Australia only, the electrical separation is
subjected to 10 impulses of alternating polarity,
using the impulse test generator reference 1 of
Table N.1. The Interval between successive
impulses is 60 s and the initial voltage, Uc, is:
for 6.2.1 a):7.0 kV for hand-held telephones and
for headsets and 2.5 kV for other equipment; and
for 6.2.1 b) and 6.2.1 c):1.5 kV.
NOTE 201 – The 7 kV impulse simulates lightning
surges on typical rural and semi-rural network
lines.
NOTE 202 – The value of 2.5 kV for 6.2.1 a) was
chosen to ensure the adequacy of the insulation
concerned and does not necessarily simulate
likely overvoltages.
6.2.2.2 For Australia only, delete the first paragraph N/A
including the Note, and replace with the following:
In Australia only, the a.c. test voltage is:
for 6.2.1 a):3 kV; and
for 6.2.1 b) and 6.2.1 c):1.5 kV.
NOTE 201 – Where there are capacitors across
the insulation under test, it is recommended that
d.c. test voltages are used.
NOTE 202 – The 3 kV and 1.5 kV values have
been determined considering the low frequency
induced voltages from the power supply
distribution system.
7.3 Add the following before the first paragraph: N/A
Equipment providing functions that fall only within
the scope of AS/NZS 60065 and that incorporate
a PSTN interface, are not required to comply with
this Clause where the only ports provided on the
equipment, in addition to a coaxial cable
connection and a PSTN interface, are audio or
Video ports and analogue or data ports not
intended to be used for telecommunications
purposes.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 11 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

AU Australia AU
Annex P Add the following Normative References: N/A
AS/NZS 3191, Electric flexible cords
AS/NZS 3112, Approval and test specification—
Plugs and socket-outlets
Index 1.Insert the following between ‘asbestos, not to be N/A
used as insulation’ and ‘attitude see orientation’:
AS/NZS 3112………………..4.3.6
AS/NZS 3191………………..3.2.5.1(Table 3B)
AS/NZS 60064………………4.1.201
AS/NZS 60695.2.11…………4.7.201.2, 4.7.201.3
AS/NZS 60695.11.10………..4.7.201.1, 4.7.201.5
AS/NZS 60695.11.5…………4.7.201.3
AS/NZS 60825.1…………….4.3.13.5.1
AS/NZS 60825.2…………….4.3.13.5.1
2. Insert the following between ‘positive
temperature coefficient(PTC) device’ and
‘Powder’:
Potential ignition source…………………1.2.201,
4.7.201.3, 4.7.201.5

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 12 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CA Canada CA
Canada and the United States of America have adopted a single, bi-national standard, 
CAN/CSA C22.2 No. 60950-1/UL60950-1, Second Edition, Amendment 1 which is
based on IEC 60950-1, Second Edition, Amendment 1. This bi-national standard should
be consulted for further details on the national conditions and differences summarized
below.

SPECIAL NATIONAL CONDITIONS 


The following is a summary of the key national differences based on national regulatory 
requirements, such as the Canadian Electrical Code (CEC) Part and the Canadian
Building Code, which are referenced in legislation and which form the basis for the rules
and practices followed in electrical and building installations.
1.1.1 All equipment is to be designed to allow P
installation in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70, the
Canadian Electrical Code (CEC), Part I,
CAN/CSA C22.1, and when applicable, the
National Electrical Safety Code, IEEE C2. Also,
unless marked or otherwise identified, installation
is allowed per the Standard for the Protection of
Electronic Computer/Data-Processing
Equipment, ANSI/NFPA 75.
1.4.14 For Pluggable Equipment Type A, the protection P
in the installation is assumed to be 20A.
1.5.5 For lengths exceeding 3.05 m, external P
interconnecting flexible cord and cable
assemblies are required to be a suitable cable
type (e.g., DP, CL2) specified in the CEC/NEC.

For lengths 3.05 m or less, external


interconnecting flexible cord and cable
assemblies that are not types specified in the
CEC are required to have special construction
features and identification markings.
1.7.1 Equipment for use on a.c. mains supply systems N/A
with a neutral and more than one phase
conductor (e.g. 120/240 V, 3-wire) require a
special marking format for electrical ratings.

A voltage rating that exceeds an attachment plug


cap rating is only permitted if it does not exceed
the extreme operating conditions in Table 2 of
CAN/CSA C22.2 No. 235, and if it is part of a
range that extends into the Table 2 "Normal
Operating Conditions." Likewise, a voltage rating
shall not be lower than the specified "Normal
Operating Conditions," unless it is part of a range
that extends into the "Normal Operating
Conditions."

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 13 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CA Canada CA
1.7.7 Wiring terminals intended to supply Class 2 N/A
outputs in accordance with CEC Part 1 or NEC
shall be marked with the voltage rating and
“Class 2” or equivalent. Marking shall be located
adjacent to the terminals and shall be visible
during wiring.
2.5 Where a fuse is used to provide Class 2, Limited N/A
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
2.6.3.3 The first column on Table 2D modified to require, N/A
“Smaller of the RATED CURRENT of the
equipment or the PROTECTIVE CURRENT
RATING of the circuit under consideration.”
2.7.1 Suitable NEC/CEC branch circuit protection rated N/A
at the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable.

Power distribution transformers distributing power


at 100 volts or more, and rated 10 kVA or more,
require special transformer overcurrent
protection.
3.2 Wiring methods (terminals, leads, etc.) used for N/A
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 14 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CA Canada CA
3.2.1 Power supply cords are required to have N/A
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
3.2.1.2 Equipment connected to a centralized d.c. power N/A
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
3.2.3 Permanent connection of equipment to the mains N/A
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
3.2.5 Power supply cords are required to be no longer N/A
than 4.5 m in length.

Minimum cord length is required to be 1.5 m, with


certain constructions such as external power
supplies allowed to consider both input and
output cord lengths into the requirement.

Flexible power supply cords are required to be


compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.
3.2.9 Permanently connected equipment is required to N/A
have a suitable wiring compartment and wire
bending space.
3.3 Wiring terminals and associated spacings for field N/A
wiring connections shall comply with CSA C22.2
No. 0.
3.3.3 Wire binding screws are not permitted to attach N/A
2
conductors larger than 10 AWG (5.3 mm ).
3.3.4 Terminals for permanent wiring, including N/A
protective earthing terminals, are required to be
suitable for Canadian/US wire gauge sizes, rated
125 percent of the equipment rating, and be
specially marked when specified (1.7.7).
3.3.5 First column of Table 3E revised to require N/A
“Smaller of the RATED CURRENT of the
equipment or the PROTECTIVE CURRENT
RATING of the circuit under consideration.”
3.4.2 Motor control devices are required for N/A
cord-connected equipment with a motor if the
equipment is rated more than 12 A, or if the
motor has a nominal voltage rating greater than
120 V, or is rated more than 1/3 hp (locked rotor
current over 43 A).
3.4.8 Vertically-mounted disconnect switches and N/A
circuit breakers are required to have the "on"
position indicated by the handle in the up position.
3.4.11 For computer room applications, equipment with N/A
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 15 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CA Canada CA
4.3.12 The maximum quantity of flammable liquid stored N/A
in equipment is required to comply with NFPA 30.
4.3.13.5 Equipment with lasers is required to meet the N/A
Canadian Radiation Emitting Devices Act, REDR
C1370 and/or Code of Federal Regulations 21
CFR 1040, as applicable.
4.7 For computer room applications, automated N/A
information storage systems with combustible
3
media greater than 0.76 m (27 cu ft) are required
to have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
4.7.3.1 For computer room applications, enclosures with N/A
combustible material measuring greater than 0.9
2
m (10 sq ft) or a single dimension greater than
1.8 m (6 ft) are required to have a flame spread
rating of 50 or less. For other applications,
enclosures with the same dimensions require a
flame spread rating of 200 or less.
Annex H Equipment that produces ionizing radiation is N/A
required to comply with the Canadian Radiation
Emitting Devices Act, REDR C1370 and/or Code
of Federal Regulations, 21 CFR 1020, as
applicable.
OTHER DIFFERENCES 
The following key national differences are based on requirements other than national regulatory
requirements.
1.5.1 Some components and materials associated with (see appended table 1.5.1) P
the risk of fire, electric shock, or personal injury
are required to have component or material
ratings in accordance with the applicable national
(Canadian and/or U.S.) component or material
standard requirements. These components
include:
attachment plugs, battery packs (rechargeable
type, used with transportable equipment),
cathode ray tubes, circuit breakers,
communication circuit accessories, connectors
(used for current interruption of non-LPS circuits),
cord sets and power supply cords, direct plug-in
equipment, enclosures (outdoor), flexible cords
and cables, fuses (branch circuit), fuseholders,
ground-fault current interrupters, industrial control
equipment, insulating tape, interconnecting
cables, lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
protectors, switches (including interlock
switches), thermal cutoffs, thermostats, (multi-
layer) transformer winding wire, transient voltage
surge suppressors, tubing, wire connectors, and
wire and cables.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 16 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CA Canada CA
1.6.1.2 A circuit for connection to the DC Mains Supply is N/A
classified as either a SELV Circuit, TNV-2 Circuit
or Hazardous Voltage Circuit depending on the
maximum operating voltage of the supply. This
maximum operating voltage shall include
consideration of the battery charging “float
voltage” associated with the intended supply
system, regardless of the marked power rating of
the equipment.
2.3.1 For TNV-2 and TNV-3 circuits with other than N/A
ringing signals and with voltages exceeding 42.4
Vpeak or 60 Vd.c., the maximum acceptable
current through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA d.c.
under normal operating conditions.
2.3.2.1 In the event of a single fault between TNV and N/A
SELV circuits, the limits of 2.2.3 apply to SELV
Circuits and accessible conductive parts.
2.6.3.4 Protective bonding conductors of non-standard N/A
protective bonding constructions (e.g., printed
circuit traces) may be subjected to the additional
limited short circuit test conditions specified.
4.2.8.1 Enclosures around CRTs with a face diameter of N/A
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
4.3.2 Equipment with handles is required to comply N/A
with special loading tests.
5.1.8.3 Equipment intended to receive N/A
telecommunication ringing signals is required to
comply with a special touch current measurement
tests.
5.3.7 Internal (e.g., card cage) SELV circuit connectors P
and printed wiring board connectors that are
accessible to the operator and that deliver power
are to be overloaded.

During abnormal operating testing, if a circuit is


interrupted by the opening of a component, the
test shall be repeated twice (three tests total)
using new components as necessary.
6.4 Equipment intended for connection to N/A
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
Annex Articulated accessibility probe (Fig EE.3) required N/A
EE for assessing accessibility to document/media
shredders instead of the Figure 2A test finger.
M.2 Continuous ringing signals up to 16 mA only are N/A
permitted if the equipment is subjected to special
installation and performance restrictions.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 17 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CA Canada CA
Annex Equipment connected to a telecommunication N/A
NAD and cable distribution networks and supplied with
an earphone intended to be held against, or in the
ear is required to comply with special acoustic
pressure requirements.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 18 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CN China CN
1.1.2 GB 4943.1-2011 applies to equipment for use at Should be evaluated when imported N/A
altitudes not exceeding 5000m above sea level, to relevant national
primarily in regions with moderate or tropical
climates.
Amend the third dashed paragraph of 1.1.2 as:
——equipment intended to be used in vehicles, on
board ships or aircraft, at altitudes greater
than 5000m;
1.4.5 After the third paragraph, add a paragraph: P
If the equipment is intended for direct connection
to an AC mains supply, the tolerances on RATED
VOLTAGE shall be taken as +10%,-10% unless a
wider tolerance is declared by the manufacturer.
The first dash paragraph "-the RATED VOLTAGE
is 230V single -phase or 400V three-phase, in
which case the tolerance shall be taken as +10%
and -10%" of IEC 60950-1:2005 is deleted in GB
4943.1-2011
1.4.12.1 Tma in clause 1.4.12.1 amended as: Tma: is the P
maximum ambient temperature permitted by the
manufacturer's specification, or 35 °C, whichever
is greater.

Add note 1: For equipment not to be operated at


tropical climatic conditions, Tma: is the maximum
ambient temperature permitted by the
manufacturer's specification, or 25 °C, whichever
is greater.
Add note 2: For equipment is to be operated at
2000m-5000m above sea leave, its temperature
test conditions and temperature limits are under
consideration.
1.5. 2 Add a note behind the first break off section in N/A
Clause 1.5.2: A component used shall comply with
related requirements corresponding altitude of
5000m.
1.7 Add one paragraph before the last paragraph: The N/A
required marking and instruction should be given
in normative Chinese unless otherwise specified.
1.7.1 Based on the AC mains supply of China, the Rated voltage: 100-240VAC; P
RATED VOLTAGE should be 220V (single phase)
or 380V (three-phases) for single rated voltage, for Rated frequency: 50/60Hz
RATED VOLTAGE RANGE, it should cover 220V
or 380V (three-phases), for multiple RATED
VOLTAGES, one of them should be 220V or 380V
(three-phases) and set on 220V or 380V (three-
phases) when manufactured.

And the RATED FREQUENCY or RATED


FREQUENCY RANGE should be 50Hz or include
50Hz.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 19 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CN China CN
1.7.2.1 Add requirements of warning for equipment Should be evaluated when imported N/A
intended to be used at altitudes not exceeding to relevant national
2000m or at non-tropical climate regions:
For equipment intended to be used at altitude not
exceeding 2000m, a warning label containing the
following or a similar appropriate wording, or a
symbol as in annex DD shall fixed to the
equipment at readily visible place.
"Only used at altitude not exceeding 2000m."

≤2000m
For equipment intended to be used in not-tropical
climate regions, a warning label containing the
following or a similar appropriate wording, or a
symbol as in annex DD shall fixed to the
equipment at readily visible place.
"Only used in not-tropical climate regions."

If only the symbol used, the explanation of the


symbol shall be contained in the instruction
manual.
The above statements shall be given in a
language acceptable to the regions where the
apparatus is intended to be used.
2.7.1 Amended the first paragraph as: P
Protection in PRIMARY CIRCUITS against
overcurrent short-circuits and earth faults shall be
provided as an integral part of the equipment
except special provisions. And the protective
device shall meet the requirement of Clause 5.3.

Delete note of Clause 2.7.1.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 20 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CN China CN
2.9.2 First section of Clause 2.9.2 amended as two Should be evaluated when imported P
sections: to relevant national
Where required by 2.9.1, 2.10.8.3, 2.10.10 or
2.10.11, humidity conditioning is conducted for
120 h in a cabinet or room containing air with
ambient temperature 40±2℃ and a relative
humidity of (93±3)%. During this conditioning the
component or subassembly is not energized.
For equipment not to be operated at tropical
climatic conditions, Where required by 2.9.1,
2.10.8.3, 2.10.10 or 2.10.11, humidity conditioning
is conducted for 48 h in a cabinet or room
containing air with a relative humidity of (93±3) %.
The temperature of the air, at all places where
samples can be located, is maintained within 2 °C
of any convenient value between 20 °C and 30 °C
such that condensation does not occur.
Due to pretreatment of equipment operated at
high altitude area is humidity conditioning
withstand hot shock, specific requirements are to
be considered.

Add note: For equipment to be operated at 2000


m - 5000m above sea level, assessment and
requirement of humidity conditioning for Insulation
material properties are considered.
2.10.3.1 Amend the third paragraph of Clause 2.10.3.1 to Should be evaluated when imported N/A
be: to relevant national
These requirements apply for equipment to be
operated up to 2000 m above sea level. For
equipment to be operated at more than 2000 m
above sea level and up to 5000m above sea level,
the minimum CLEARANCE shall be multiplied by
the factor 1.48 corresponding altitude of 5000m
given in Table A.2 of IEC 60664-1. For equipment
to be operated at more than 5000 m above sea
level, the minimum CLEARANCE shall be
multiplied by the factor given in Table A.2 of IEC
60664-1. Linear interpolation is permitted between
the nearest two points in Table A.2. The calculated
minimum CLEARANCE using this multiplication
factor shall be rounded up to the next higher 0,1
mm increment.
2.10.3.3& Add "(applicable for altitude up to 2000m)" in N/A
2.10.3.4 header of Table 2K, 2L and 2M.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 21 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CN China CN
2.10.3.4 Add a new section above Table 2K and in Clause N/A
2.10.3.4:
Minimum CLEARANCES determined by above
rules apply for equipment to be operated up to
2000m above sea level. For equipment to be
operated at 2000 m - 5000m above sea level, the
minimum CLEARANCE shall be multiplied by the
factor 1.48 corresponding altitude of 5000m given

in Table A.2 of GB/T16935.1 IEC 60664-1 . )
For equipment to be operated at more than 5000
m above sea level, the minimum CLEARANCE
shall be multiplied by the factor given in Table A.2
of GB/T16935.1.
3.2.1.1 Add a paragraph before the last paragraph: N/A
Plugs connected to AC mains supply shall comply
with GB 1002 or GB 1003 or GB/T 11918 as
applicable.
4.2.8 Clause 4.2.8 cathode ray tubes quoted Clause 18 N/A
of GB8898-2011.

Delete note of Clause 4.2.8.


Annex E Last section of Annex E amended as: For N/A
comparison of winding temperatures determined
by the resistance method of this annex with the
temperature limits of Table 4B, 35 °C shall be
added to the calculated temperature rise. And add
note: for equipment not to be operated at tropical
climatic conditions, 25 °C shall be added to the
calculated temperature rise to compare with the
temperature of Table 4B.
Annex Change the second section of Clause G.6 to be: N/A
G.6 For equipment to be operated at 2000 m - 5000m
above sea level, the minimum CLEARANCE shall
be multiplied by the factor 1.48 corresponding
altitude of 5000m given in Table A.2 of
GB/T16935.1. For equipment to be operated at
more than 5000 m above sea level, the minimum
CLEARANCE shall be multiplied by the factor
given in Table A.2 of IEC 60664-1. Linear
interpolation is permitted between the nearest two
points in Table A.2. The calculated minimum
CLEARANCE using this multiplication factor shall
be rounded up to the next higher 0,1 mm
increment.
Annex BB Amended as : N/A
(informati The differences between Chinese national
ve) standards GB 4943.1-2011 and GB 4943-2001.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 22 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CN China CN
Annex Added annex DD: Instructions for the new safety N/A
DD warning labels.
(normativ
e) DD.1 Altitude warning label

Meaning of the label: Evaluation for apparatus only


based on altitude not exceeding 2000m, therefor
it’s the only operating condition applied for the
equipment .There may be some potential safety
hazard if the equipment is used at altitude above
2000m .

DD.2 Climate warning label

Meaning of the label: Evaluation for apparatus only


based on temperate climate condition, therefor it’s
the only operating condition applied for the
equipment .There may be some potential safety
hazard if the equipment is used in tropical climate
region.
Annex EE Added annex EE: N/A
(informati Illustration relative to safety explanation in
ve) normative Chinese, Tibetan, Mongolian, Zhuang
Language and Uighu.
Other In accordance with the relevant CTL decisions and N/A
amendm the amendments of IEC 60950-1, the specific
ents requirements or mistakes in IEC standard are
corrected or editorially modified in this part,
Including clause 1.7, 2.1.1.7, 2.9.2, Table 2H,
Figure 2H, F.8, F.9, M.3 and Annex U.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 23 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

CN China CN
Quoting The principles of quoting and referring to other standards in Annex P and reference N/A
standards documents of IEC 60950-1 are as follows:
and If the date of the reference document is given, only that edition applies, excluding any
reference subsequent corrigenda and amendments. However, parties to agreements based on this
document part are encouraged to investigate the possibility of applying the most recent editions of
s the reference documents. For undated references, the latest edition of the referenced
document applies, including any corrigenda and amendments.
For the usage of international standards in Chinese national standards and industry
standards is various, in the aim of achieving easy operation and based on the
requirements of GB/T 1.1 and GB/T 20000.2, when quoting an entire international
standard in the normative quoting files and reference documents of Annex P of this part,
the principles of quotation are as follows:
- If there is no national standard or industry standard corresponding to the international
standard, then the international standard is quoted;
- If there is national standard or industry standard corresponding to the international
standard, then either the national or industry standard is quoted;
- If the date of the national standard or industry standard is not given, the latest edition of
the standard applies;
- The national standard or industry standard number, corresponding international
standard number and the consistency level code should be identified in parentheses
behind the listed national standard or industry standard.
When quoting several chapters or clauses of the international standard, the principles of
quotation are as follows:
- If there is no national standard or industry standard corresponding to the international
standard, then the international standard is quoted;
- If there is national standard or industry standard corresponding to the international
standard, then either the national or industry standard is quoted.
Meanwhile, in order to retain the relevant information on international standards,
informative annex CC is increased, which gives the table about the comparison of the
normative quoting files and reference documents in IEC 60950-1: 2005 and GB 4943.1-
2011.

DE Germany DE
1.5 The moulded plug of plug-in power supplies will P
be considered as component and will be
generally evaluated in Germany according to DIN
VDE 0620-1:2010 respectively DIN VDE 0620-
1:2013 and DIN VDE 0620-2-1:2013.
After the test according to DIN VDE 0620-2-
1:2013, sub-clause 24.2, the plug be shall still
pass the test according to DIN VDE 0620-
101:1992 clause 7, figure 2 “Gauge for
interchangeability”.

It should be possible to insert the plug without


applying an excessive force such that the end
surface touches the surface of the gauge.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 24 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

DE Germany DE
Annex According to GPSG, section 2, clause 4: P
ZC, cl. If certain rules on the use, supplementation or
1.7.2.1 maintenance of an item of technical work
equipment or ready-to-use commodity must be
observed in order to guarantee safety and health,
instructions for use in German must be supplied
when it is brought into circulation.

DK Denmark DK
1.2.4.1 In Denmark, certain types of Class I appliances N/A
(see 3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.

1.7.5 In Denmark, socket-outlets for providing power N/A


to other equipment shall be in accordance with
the Heavy Current Regulations, Section 107-2-
D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-
7a, when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet
shall be in accordance with Standard Sheet DK
1-1b or DK 1-5a.

For CLASS II EQUIPMENT the socket outlet


shall be in accordance with Standard Sheet
DKA 1-4a.
3.2.1.1 In Denmark, supply cords of single-phase N/A
equipment having a rated current not
exceeding13 A shall be provided with a plug
according to the Heavy Current Regulations,
Section 107-2-D1.

CLASS I EQUIPMENT provided with socket-


outlets with earth contacts or which are
intended to be used in locations where
protection against indirect contact is required
according to the wiring rules shall be provided
with a plug in accordance with standard sheet
DK 2-1a or DK 2-5a.

If poly-phase equipment and single-phase


equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord
with a plug, this plug shall be in accordance
with the Heavy Current Regulations, Section
107-2-D1 or EN 60309-2.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 25 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

ES Spain ES
3.2.1.1 In Spain, supply cords of single-phase equipment N/A
having a rated current not exceeding 10 A shall
be provided with a plug according to UNE
20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to UNE-EN
50075:1993.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the wiring
rules, shall be provided with a plug in accordance
with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 26 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

FI Finland FI
1.5.7.1 Resistors bridging BASIC INSULATION in N/A
CLASS I PLUGGABLE EQUIPMENT TYPE A
must comply with the requirements in 1.5.7.2. In
addition when a single resistor is used, the
resistor must withstand the resistor test in 1.5.7.2.
1.5.9.4 The third dashed sentence is applicable only to N/A
equipment as defined in 6.1.2.2 of this annex.
1.7.2.1 CLASS I PLUGGABLE EQUIPMENT TYPE A N/A
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed
mains socket-outlet.
The marking text shall be as follows:
"Laite on liitettävä suojakoskettimilla varustettuun
pistorasiaan"
2.3.2 There are additional requirements for the N/A
insulation. See 6.1.2.1 and 6.1.2.2 of this
annex.
2.10.5.1 There are additional requirements for the N/A
3 insulation. See 6.1.2.1 and 6.1.2.2 of this
annex.
5.1.7.1 TOUCH CURRENT measurement results N/A
exceeding 3,5 mA r.m.s. are permitted only for
the following equipment:
• STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
o is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential
bonding has been applied, for example, in
telecommunication centre; and
o has provision for a permanently
connected PROTECTIVE EARTHING
CONDUCTOR; and
o is provided with instructions for the
installation of that conductor by a
SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
• STATIONARY PERMANENTLY
CONNECTED EQUIPMENT.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 27 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

FI Finland FI
6.1.2.1 Add the following text between the first and N/A
second paragraph of the compliance clause:

If this insulation is solid, including insulation


forming part of a component, it shall at least
consist of either

- two layers of thin sheet material, each of


which shall pass the electric strength test
below, or
- one layer having a distance through
insulation of at least 0,4 mm, which shall
pass the electric strength test below.
Alternatively for components, there is no distance
through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do
not exist, if the component passes the electric
strength test in accordance with the compliance
clause below and in addition
- passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV),
and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test
voltage of 1,5 kV.
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to EN 60384-
14:2005, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 60384-14:2005, which in addition to the Y3
testing, is tested with an impulse test of
2,5 kV defined in EN 60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in
EN 60384-14:2005
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 60384-14:2005,
in the sequence of tests as described in EN
60384-14:2005.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 28 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

FI Finland FI
6.1.2.2 The exclusions are applicable for N/A
PERMANENTLY CONNECTED EQUIPMENT,
PLUGGABLE EQUIPMENT TYPE B and
equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR and is
provided with instructions for the installation of
that conductor by a SERVICE PERSON.
7.2 For requirements see 6.1.2.1 and 6.1.2.2 of this N/A
annex. The term TELECOMMUNICATION
NETWORK in 6.1.2 being replaced by the term
CABLE DISTRIBUTION SYSTEM.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 29 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

GB United Kingdom GB
2.6.3.3 In the United Kingdom, the current rating of the N/A
circuit shall be taken as 13 A, not 16 A.
2.7.1 In the United Kingdom, to protect against P
excessive currents and short-circuits in the
PRIMARY CIRCUIT of DIRECT PLUG-IN
EQUIPMENT, tests according to 5.3 shall be
conducted, using an external protective device
rated 30 A or 32 A. If these tests fail, suitable
protective devices shall be included as integral
parts of the DIRECT PLUG-IN EQUIPMENT, so
that the requirements of 5.3 are met.
3.2.1.1 In the United Kingdom, apparatus which is fitted N/A
with a flexible cable or cord and is designed to be
connected to a mains socket conforming to BS
1363 by means of that flexible cable or cord and
plug, shall be fitted with a ‘standard plug’ in
accordance with Statutory Instrument 1768:1994
- The Plugs and Sockets etc. (Safety)
Regulations 1994, unless exempted by those
regulations.
NOTE ‘Standard plug’ is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
3.2.5.1 In the United Kingdom, a power supply cord with N/A
2
conductor of 1,25 mm is allowed for equipment
with a rated current over 10 A and up to and
including 13 A.
3.3.4 In the United Kingdom, the range of conductor N/A
sizes of flexible cords to be accepted by terminals
for equipment with a RATED CURRENT of over
10 A up to and including 13 A is:
2 2
• 1,25 mm to 1,5 mm nominal cross-sectional
area.
4.3.6 In the United Kingdom, the torque test is P
performed using a socket outlet complying with
BS 1363 part 1:1995, including Amendment 1:
1997 and Amendment 2:2003 and the plug part of
DIRECT PLUG-IN EQUIPMENT shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.13, 12.16 and 12.17,
except that the test of 12.17 is performed at not
less than 125 °C. Where the metal earth pin is
replaced by an Insulated Shutter Opening Device
(ISOD), the requirements of clauses 22.2 and 23
also apply.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 30 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

IE Ireland IE
3.2.1.1 In Ireland, apparatus which is fitted with a flexible N/A
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
4.3.6 In Ireland, DIRECT PLUG-IN EQUIPMENT is N/A
known as plug similar devices. Such devices shall
comply with Statutory Instrument 526:1997 -
National Standards Authority of Ireland (Section
28) (Electrical plugs, plug similar devices and
sockets for domestic use) Regulations, 1997.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 31 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

IL Israel IL
1.6.1 Note: In Israel, the clause is subject to Electricity N/A
Law, 1954, its regulations and updates.
1.7.201 Marking in the Hebrew language N/A
The marking in the Hebrew language shall be in
accordance with the Consumer Protection Order
(Marking of goods), 1983.
In addition to the marking required by clause
1.7.1, the following shall be marked in Hebrew
language.
1. Name of the apparatus and its commercial
designation;
2. Manufacturer's name and address; if the
equipment is imported, the importer's name and
address;
3. Manufacturer's registered trademark, if any;
4. Name of the model and serial number, if any;
5. Country of manufacture.
The details shall be marked on the apparatus or
on its packaging, or on a label well attached to
the apparatus or on the packaging, by bonding or
sewing, such that the label cannot be easily
removed.
1.7.2.1 All the instructions and warnings related to safety N/A
shall also be written in the Hebrew language.
1.201 Power consumption in standby mode Shall be considered during national N/A
The equipment shall comply with the approved
requirements of the Energy Sources Regulations
(Maximum electrical power in standby mode for
domestic and office electrical appliances), 20011,
with a permitted deviation of up to 10%
2.9.4 Separation from hazardous voltages N/A
-The following shall be added at the beginning of
the clause:
According to the Electricity Law, 1954, and the
Electricity Regulations (Earthing and means of
protection against electricity of voltages up to
1000V) , 1991, in Israel, seven means of
protection from electrocution are permitted, as
follows:
1) Network system earthing - (TN-C-S, TN –S);
2) Network system earthing - (TT);
3) Network Insulation Terre – (IT);
4) Isolated transformer;
5) Safety extra low voltage;
6) Residual current circuit breaker;
7) Reinforced insulation; Double insulation.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 32 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

IL Israel IL
2.201 Prevention of electromagnetic interference N/A
The device shall meet the requirements in the
relevant part of the Israeli Standard series, SI
961.
If the device contains components for the
prevention of electromagnetic interference, the
devices shall not lower the safety level of the
device, as required by this standard.
3.2.1.1 Note: In Israel, the feed plug shall comply with N/A
thee requirements of Israel Standard SI 32
Part1.1.
3.2.1.2 Note: As of the date of publication of this N/A
standard, there is no Israel Standard for
connection accessories to d.c.
Annex P Normative references P

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 33 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

IL Israel IL
P

The referenced The substituted Israel Comments


International Standard
Standard
(a)
IEC 60065: SI 60065 - Audio, video The Israel Standard, excluding
2001 and similar electronic national modifications and
apparatus – Safety additions noted, is identical to
requirements the International Standard, IEC
60065 – Edition 7.1:2005-12
IEC 60083 (a) The Israeli Standard, excluding
Si 32 Part 1.1 - Plugs
national modifications and
and socket-outlets for
additions noted, is identical to
household and similar
the International Standard, IEC
purposes: plugs and
60884-1 – Third edition:2002-06
socket-outlets for single
phase up tp 16A-General
REuse standardized
IEC 60227 SI 60227 (all parts)- The Israeli Standard series,
(all parts) Polyvinyl chloride excluding national modifications
insulated cables of rated and additions noted, is identical
voltage up to and to the Standard series, IEC
including 450/750V 60227 (all parts)
IEC 60245 SI 60245 Part 1 – Rubber The Israeli Standard series,
(all parts) insulated cables - Rated excluding national modifications
voltage up to and and additions noted, is identical
including 450/750V: to the Standard series, IEC
General requirements 60245 (all parts)
IEC 60309 SI 1109 Part 1 -Plugs, The Israeli Standard, excluding
(all parts)(b) socket- outlets and national modifications and
couplers for industrial additions noted, is identical to
purposes: General the International Standard, IEC
requirements 60309-1 – Fourth edition: 1999-
2.
SI 1109 Part 2 -Plugs, The Israeli Standard, excluding
socket- outlets and national modifications and
couplers for industrial additions noted, is identical to
purposes: Dimensional the International Standard, IEC
interchangeability 60309-1 – Fourth edition: 1999-
requirements for pin and 4.
contact-tube accessories
IEC 60317 SI 1067 Part 1 – The Israeli Standard is identical
(all parts)(b) Enameled(e) round to the International
copper wires with high Electrotechnical Commission
mechanical properties Standard IEC 3l7-1: 1980-02
SI 1067 Part 2 - Self- The Israel Standard is identical
fluxing enamelled(e) to the International
round copper wires Electrotechnical Commission
Standard IEC 307-4: 1980-02
SI 1067 Part 3 - The Israel Standard is identical
Enameled(e) round to the International
copper wires with a Electrotechnical Commission
temperature index of IEC 317-8: 1980-02
180ºC
TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 34 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

IL Israel IL
P

The referenced The substituted Israel Comments


International Standard
Standard
IEC 60320 SI 60320 Part 1 - The Israel Standard, excluding
(all parts)(b) Appliance couplers for national modifications and additions
household and similar noted, is identical to the
general purposes: International Electrotechnical
General requirements Commission Standard, IEC 60320-
1: Second edition: 2001-06
SI 60320 Part 2.1 - The Israel Standard, excluding
Appliance couplers for national modifications and additions
household and similar noted, is identical to the
general purposes: Sewing International Electrotechnical
machine couplers Commission Standard, IEC 60320-
2-1: Second edition: 2000-07
SI 60320 Part 2.2 - The Israel Standard, excluding
Appliance couplers for national modifications and additions
household and similar noted, is identical to the
general purposes: International Electrotechnical
Interconnection couplers Commission Standard, IEC 60320-
for household and similar 2-2: Second edition: 1998-08
equipment
SI 60320 Part 2.3 - The Israel Standard, excluding
Appliance couplers for national modifications and additions
household and similar noted, is identical to the
general purposes: International Electrotechnical
appliance coupler with a Commission Standard, IEC 60320-
degree of protection 2-3: First edition: 1998-09.
higher than IPXO
IEC 60364-1: Electricity Law, 1954, with -
2001 its Regulations and
updates
IEC 60730-1: SI 60730 Part 1 - The Israel Standard, excluding
1999 Automatic electrical national modifications and additions
Amendment 1 controls for household noted, is identical to the
(2003) and similar use: International Electrotechnical
General requirements Commission Standard, IEC 60730-
1: Edition 3.2: 2007-03.
IEC 60825-1 SI 60825 Part 1 - Safety The Israel Standard, excluding
of products: Equipment national modifications and additions
classification and noted, is identical to the
requirements International Electrotechnical
Commission Standard, IEC 60825-
1: Second edition 3.2: 2007-03.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 35 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

IL Israel IL
P

The referenced
The substituted Israel
International Comments
Standard
Standard
IEC 60947-1: 2004 SI 60947 Part 1 -Low- The Israel Standard, excluding
voltage switchgear and national modifications and
controlgear: General rules additions noted, is identical to the
International Electrotechnical
Commission Standard, IEC
60947-1: Edition 5.0: 2007-06.
IEC 61058-1: 2000 SI 61058 Part 1 - The Israel Standard, excluding
Switches for appliances: national modifications and
General requirements additions noted, is identical to the
International Electrotechnical
Commission Standard, IEC
61058-1: Edition 3.1: 2001.
ISO 3864 SI 3864 Part 1(a) - The Israel Standard, excluding
Graphical symbols national modifications and
(all parts)(b)
additions noted, is identical to the
International Organization for
Standardization Standard, ISO
3864-1: First edition 2002-05-15.
Notes:
(a) This Standard is being revised.
(b) In the International Standard series, there are parts not yet adopted as Israeli
Standards. This table notes the relevant Israeli Standards, and in the Comments
column, the corresponding parts of the International Standard series.
(c) Not relevant to the translation.

-The following shall be added to the annex: N/A


Israel Standards
SI 961 (all parts) – Electromagnetic compatibility
Israeli Laws, Regulations and documents
Electricity Law, 1954, with its Regulations and updates
Cosumer Protection Order (Marking of goods), 1983, Kovetz Hatakanot 4465 daed
1983-02-24
Energy Sources Regulations (Maximum electrical power in standby mode for domestic
and office electrical appliances), 2011

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 36 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
1.2.4.1 Replace the existing NOTE as NOTE 1, and Added. N/A
add NOTE 2 as following:
NOTE 2: Even if the equipment is designed as
CLASS I EQUIPMENT, if a 2-pin plug adaptor
with a protective earthing lead wire (adaptor
which converts a plug for CLASS I EQUIPMENT
to a 2-pin plug with no earthing contact) or a
cord set having a 2-pin plug with a protective
earthing lead wire is packed as accessory
together with the equipment or if use of those is
recommended to the users, the equipment is
considered as CLASS 0I EQUIPMENT.
1.2.4.3A Add 1.2.4.3A as following: Added. N/A
1.2.4.3A
CLASS 0I EQUIPMENT
Equipment having a mains plug without earthing
contact, which protection against electric shock
is achieved by:
- using BASIC INSULATION; and
- for the measures to connect conductive
part(s) regarded as part at HAZARDIUS
VOLTAGE in the event of fault of BASIC
INSULATION to PROTECTIVE EARTHING
CONDUCTOR, equipping any one of the
following:
a) mains plug with a protective earthing lead
wire, this includeds the following cases:
- where a 2-pin plug adaptor with a
protective earthing lead wire is packed as
accessory together with the equipment; or
- where use of it is recommended.
b) independent protective earthing terminal
(see 2.6.5.8A) if the equipment uses a
power supply cord of two conductors
(exclude earthing conductor)
NOTE - CLASS 0I EQUIPMENT may have a
part constructed with DOUBLE INSUILATION or
REINFORCED INSULATION.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 37 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
1.3.2 Add the following NOTEs after first paragraph: Added. N/A
NOTE 1 TRANSPORTABLE or similar
equipment that are relocated frequently for
intended usage it is recommended not to design
as CLASS I or CLASS 0I EQUIPMENT unless it
is intended to be installed by a SERVICE
PERSON or installation personnel.

NOTE 2 Considering wiring circumstance in


Japan, equipment intended to be installed
where the provision for earthing connection is
unlikely should not be designed as CLASS I or
CLASS 0I EQUIPMENT unless it is intended to
be installed by a SERVICE PERSON or
installation personnel.
1.5.1 Replace the first paragraph with the following: Added. P
Where safety is involved, components shall
comply either with the requirements of this
standard, with the safety aspects of the relevant
JIS component standards, or IEC component
standards in case there is no applicable JIS
component standard available. However, a
component that falls within the scope of METI
Ministerial ordinance No. 85 is properly used in
accordance with its marked ratings,
requirements of 1.5.4, 2.8.7 and 3.2.5 apply,
and in addition, for connector of power cord set
which is capable of insertion to one of appliance
inlets specified in either IEC 60320-1 or JIS C
8283-1, the connector shall comply with the
dimensions of the appropriate connector
specified in IEC 60320-1 or JIS C 8283-1.

Replace NOTE 1 with the following:


NOTE 1 A JIS or an IEC component standard
is considered relevant only if the component in
question clearly falls within its scope.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 38 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
1.5.2 Replace first sentence in the first dashed Added. P
paragraph with the following:
- a component that has been demonstrated
to comply with a JIS component standard
harmonized with the relevant IEC
component standard, or where such JIS
component standard is not available, a
component that has been demonstrated to
comply with the relevant IEC component
standard shall be checked for correct
application and use in accordance with its
rating.
Replace existing NOTE to NOTE 1 without
modification of the sentence in the second
dashed paragraph.

Replace “where no relevant IEC component


standard exists” to “where neither the relevant
IEC component standard nor JIS standard
corresponding to the relevant IEC component
standard exists” in the third dashed paragraph.

Add NOTE 2 as follows:


NOTE 2 If an appliance inlet with a rated current
of 10A, which is of STANDARD SHEET C14
specified in JIS C 8283-1, is used for equipment
with a rated voltage of 125V or less; and with a
rated current of exceeding 10A, refer to 1.7.5A.
1.5.9.1 Add the following at the end of NOTE 1: No gas discharge tube (GDT) used. N/A
Gas discharge tube (GDT) may be connected to
VDR in series.
1.5.9.4 Add the following at last paragraph: No gas discharge tube (GDT used. N/A
If a GDT complies with the requirements for
FUNCTIONAL INSULATION, the GDT may be
connected to a VDR bridging BASIC
INSULATION in accordance with the conditions
specified in this sub-clause in series.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 39 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
1.7.1 Replace the existing dashed items for Replaced. P
manufacturer’s name etc. and for model
identification etc. with the following respectively:
- manufacturer’s (or responsible business
operator’s) name or trade-mark or
identification mark;
- manufacturer’s (or responsible business
operator’s) model identification or type
reference;
In the last paragraph, replace “ISO 7000 or IEC
60417” with “JIS S 0101, ISO 7000 or IEC
60417”.
1.7.2.1 Add the following: Added. P
Instructions and the marking(s) on equipment, Instruction in Japanese provided.
which related to safety, shall be made in
Japanese.
1.7.5 Replace IEC 60083 with JIS C 8303 in the Replaced. N/A
second paragraph.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 40 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
1.7.5A Add the following new clause after 1.7.5 Added. N/A
1.7.5.A Power supply cord set
If an appliance inlet with a rated current of 10 A,
which is of STANDARD SHEET C14 specified in
JIS C 8283-1, is used for equipment with a rated
voltage of 125 V or less and with a rated current
of exceeding 10 A, the operating instructions
shall provide the following or equivalent
instruction:

For equipment with an appliance inlet, if a power


supply cord set is not provided by packing
together with the equipment, the operating
instructions shall provide information on the
applicable power supply cord set.
NOTE For the combination of CLASS 0I
EQUIPMENT equipped with an appliance inlet
with earthing contact and a power supply cord
set of two conductors (exclude earthing
conductor), to pack the power supply cord set
together with the equipment and to provide a
sentence calling attention of the following purport
in the operating instructions are recommended,
because such power supply cord set is a special
kind of cord set:
- this is usable only for this equipment;
and
- to use this for other equipment is not
allowed.
1.7.14A Add the following new clause after 1.7.14 Added. N/A
1.7.14A Marking for protective earthing
connection for CLASS 0I EQUIPMENT
CLASS 0I EQUIPMENT shall be provided with
the following or equivalent instruction:
- on the mains-plug or the easily visible
section of equipment, the following
instruction:

- in the easily visible section of equipment


or in the operating instructions, the following
instruction:

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 41 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
1.7.14B Add the following new clause after 1.7.14 Added. N/A
1.7.14B Protective earth wire used for CLASS 0I
EQUIPMENT
For CLASS 0I EQUIPMENT equipped with a
separate protective earthing terminal as main
protective earthing terminal, if a protective earth
wire is not provided by packing together with the
equipment, the operating instructions shall
provide information on the applicable protective
earth wire. (See 2.6.3.2.)
2.1.1.1 In b) of the fifth paragraph, replace “IEC 60083, Replaced. P
IEC 60309, IEC 60320, IEC 60906-1 or IEC
60906-2” with “JIS C 8303, (the Ministerial
Ordinance establishing Technical Requirements
for Electrical Appliances and Materials, MEIT
Ordinance No. 85, Clause 1 (METI Ordinance
No. 34 of 2013), JIS C 8285, the IEC 60309
series of standards, the JIS C 8283 series of
standards, the IEC 60320 series of standards”.
2.6.3.2 Add the following: Added. N/A
If the conductor of protective earthing lead wire
or the protective earth wire of CLASS 0I
EQUIPMENT is of single-core, it shall be one of
the following:
- annealed copper wire of 1,6 mm in
diameter, or metallic wire having the same or
more strength and diameter and being not easily
corrosive; or
- single-core cord or single-core cabtyre
cable (sheathed flexible cable), which have a
2
cross-sectional area of at least 1,25 mm .
2.6.3.5 Add the following: Added. N/A
However, this requirement does not apply to the
inside conductor of power supply cord (or power
supply cord set), which has been molded
together with a plug and a connector and has
been sheathed.
2.6.4.2 Add the following: Added. N/A
For CLASS 0I EQUIPMENT equipped with a
separate protective earthing terminal, the
protective earthing terminal may be used as the
main protective earthing terminal.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 42 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
2.6.5.4 Replace 1st sentence with the following. Added. N/A
“Protective earthing conductors” with “Protective
earthing conductors of CLASS I EQUIPMENT”.
2.6.5.6 Replace “protective earthing terminals” with Added. N/A
“protective earthing and protective bonding
terminals”.
2.6.5.8A Add the following new clause. after 2.6.5.8A Added. N/A
2.6.5.8A Earthing of CLASS 0I EQUIPMENT
Plugs with a lead wire for earthing shall not be
used for equipment having a rated voltage
exceeding 150V.
For plugs with a lead wire for earthing, the lead
wire shall not be earthed by a clip.
CLASS 0I EQUIPMENT shall be provided with
an earthing terminal or lead wire for earthing in
the external location where easily visible.
2.9.3 Deleted the following mark of Figure 2H: N/A
Table 2H
B13 e) and S2 d)
2.9.3 Addition of marking for table 2H: N/A
Figure 2H
B8, B9, B12, B13, S1
2.10.3.1 In the third paragraph, replace IEC 60664-1 with Replaced. P
JIS C 60664-1.

Replace the 8th paragraph with the following:


The above minimum CLEARANCES for
connectors do not apply to:
- connectors that comply with JIS C 8285,
the IEC 60309 series of standards, the JIS C
8283 series of standards, the IEC 60320 series
of standards or JIS C 8303; and
- connectors that comply with the
Ministerial Ordinance establishing Technical
Requirements for Electrical Appliances and
Materials MEIT Ordinance No. 85, Clause 1
(METI Ordinance No. 34 of 2013), and comply
with the dimensions specified in the JIS C 8283
series of standards, JIS C 8303 or IEC 60309-2;
see also 1.5.2.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 43 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
2.10.3.2 In the bottom column of Table 2J, add the Added. P
following:
In Japan, the MAINS TRANSIENT VOLTAGE
value against the nominal AC MAINS SUPPLY
voltage of 100 V is decided by applying the
columns for the AC MAINS SUPPLY voltage of
150 V.
2.10.3.3 In Table 2L, add the following into the column Added. P
specifying the additional CLEARANCES and at
the end:
For intermediate voltage values between the
PEAK WORKING VOLTAGE values given in this
table, linear interpolation is permitted between
the nearest two points, the calculated additional
minimum CLEARANCE being rounded up to the
next higher 0,1 mm increment.
2.10.4.3 Replace the 6th paragraph with the following: Replaced. P
The above minimum CLEEPAGE DISTANCES
for connectors do not apply to:
- connectors that comply with JIS C 8285,
the IEC 60309 series of standards, the JIS C
8283 series of standards, the IEC 60320 series
of standards or JIS C 8303; and
- connectors that comply with the
Ministerial Ordinance establishing Technical
Requirements for Electrical Appliances and
Materials MEIT Ordinance No. 85, Clause 1
(METI Ordinance No. 34 of 2013), and comply
with the dimensions specified in the JIS C 8283
series of standards, JIS C8303 or IEC 60309-2;
see also 1.5.2.
1
2.10.9 Replace clause which as test method of T from Replaced. N/A
1.4.5 to 1.4.12.
3.2.1.1 Add the following: Added. N/A
When equipment with an appliance inlet
connects to AC mains supply, see clause 1.7.5A
for the relevant mark of power supply cord set.
3.2.3 Add the following after Table 3A: Added. N/A
Table 3A applies when cables complying JIS C
3662 or JIS C 3663 are used. In case of other
cables, cable entries shall be so designed that a
conduit suitable for the cable used can be fitted.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 44 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
3.2.4 Add the following: Added. N/A
The equipment shall have a structure of which
the soldered sections of the terminals of
appliance inlet are not subjected to mechanical
stress during the insertion or removal of the
connector, except the case fixing the appliance
inlet itself mechanically but not only by
soldering.
3.2.5.1 At the end of the first dashed item, replace “; Added. N/A
and” with “, or be a sheathed cord complying
with Appendix 1 specified in the Interpretation
for the Ministerial Ordinance establishing
Technical Requirements for Electrical
Appliances and Materials MEIT Ordinance No.
85, Clause 1 (METI Ordinance No. 34 of 2013) ;
and”.
In the second dashed item, replace “insulated:” Added. N/A
with “insulated, be a cord of the following or be a
sheathed cord complying with Appendix 1
specified in the Interpretation for the Ministerial
Ordinance establishing Technical Requirements
for Electrical Appliances and Materials MEIT
Ordinance No. 85, Clause 1 (METI Ordinance
No. 34 of 2013), :”
In the third dashed item, add the following: Added. N/A
However, the coating of the protective earth
conductor inside covered with sheath (cord set)
power cord integrally formed with the connector
and the plug need not be a combination of
green and yellow. In addition, the power cord of
CLASS OI EQUIPMENT having a protective
earth conductor separately, it is not necessary to
provide a protective earth conductor.
Replace the existing fourth dashed item with the Added. N/A
following:
- if those complying with JIS C 3662-5 or JIS
C 3663-4, have conductors with cross-
sectional areas not less than those specified
in Table 3B, and if others, comply with the
relevant wiring rules.

In Table 3B, replace “IEC 60320” with “the JIS


C8283 series of standards or the IEC 60320
series of standards”.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 45 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
3.3.4 Add the following note to Table 3D: Added. N/A
For cables other than those complying with JIS
C 3662 or JIS C 3663, terminals shall be
suitable for the size of the intended cables.
3.3.7 Add the following after the first sentence: Added. N/A
This requirement is not applicable to the
external earting terminal of CLASS 0I
EQUIPMENT.
4.3.4 Add the following after the first sentence: Added. N/A
This requirement also applies to those
connections in CLASS 0I EQUIPMENT, where
CLEARANCE or CREEPAGE DISTANCES of
BASIC INSULATION would be reduced to less
than the values specified in 2.10.
4.3.5 In the paragraph, replace “IEC 60083 or IEC Replaced. N/A
60320” with “the JIS C 8283 series of standards,
JIS C 8303 or JIS C 8358”.
4.5.3 In the item b in Table 4B, add the following: Replaced. P
NOTE If no data of material is available,
Appendix 4, 1(1),ロ,3 specified in the
Interpretation for “the Ministerial Ordinance
establishing Technical Requirements for
Electrical Appliances and Materials MEIT
Ordinance No. 85, Clause 1 (METI Ordinance
No. 34 of 2013)” is applicable.

In the item c in Table 4B, replace IEC 60085


with JIS C 4003.
5.1.3 Add a note after the first paragraph as follows: Added. N/A
NOTE In Japan, three-phase power distribution Single phase power distribution
systems of delta connection are typical, system used.
therefore, in such case, test is conducted using
the test circuit from IEC 60990, figure 13.
5.1.6 Replace Table 5A as follows Replaced. P

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 46 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)

Type of Terminal A of Maximum Maximum


equipment
measuring instrument TOUCH PROTECTIVE
CURRENT CONDUCTOR
connected to:
a CURRENT
mA r.m.s.
All equipment Accessible parts and circuits not 0,25 –
b
connected to protective earth
HAND-HELD Class I equipment main 0,75 –
protective earthing terminal
Class 0I equipment main 0,5 –
protective earthing terminal
MOVABLE (other Class I equipment main 3,5 –
than HAND- protective earthing terminal
HELD, but
Class 0I equipment main 1,0 –
including
protective earthing terminal
TRANSPORTABL
E EQUIPMENT)
STATIONARY, Class I equipment main 3,5 –
PLUGGABLE protective earthing terminal
TYPE A
Class 0I equipment main 1,0 –
protective earthing terminal
All other
STATIONARY
Class I equipment main 3,5 –
EQUIPMENT
protective earthing terminal
– 5 % of input
– not subject to
current
the conditions of
5.1.7 Class 0I equipment main 1,0 –
protective earthing terminal
– subject to the – –
conditions of 5.1.7
a
If peak values of TOUCH CURRENT are measured, the maximum values are obtained
by multiplying the r.m.s. values in the table by 1,414.
b
Some unearthed accessible parts are covered in 1.5.6 and 1.5.7 and the requirements
of 2.4 apply. These may be different from those in 5.1.6.
6 Add following in the end of NOTE 1: No TNV.
N/A
For suitable additional measures, see Annex JB.
6.1.2.1 Add the following: No TNV.
N/A
NOTE 3 For example, the highest nominal
voltage is 230 V in Europe and 120 V in North
America.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 47 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
th
Annex G.6 Replace the existing 8 paragraph with the The alternative method was not
following: considered. N/A
The above minimum CLEARANCES for
connectors do not apply to:
- connectors that comply with JIS C 8285, the
IEC 60309 series of standards, the JIS C
8283 series of standards, the IEC 60320
series of standards or JIS C 8303; and
- connectors that with the Ministerial Ordiance
establishing Technical Requirements for
Electrical Appliances and Materials (MEIT
Ordinance No. 34 of 2013) and comply with
the dimensions specified in the JIS C 8283
series of standards, JIS C 8303 or IEC 60309-
2;
see also 1.5.2.
Annex M In M.1, replace the existing paragraph with the No telephone ringing signals.
following: N/A
One of the two methods specified in this annex
shall be applied.
NOTE Method A specified in the annex is typical
of analogue telephone network in Europe and
Method B of those in North America.
Annex P Replace the existing Annex P with the following: Replaced. P

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 48 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
Annex P
(normative)
Normative references
The following reference documents are indispensable for the application of this standard. If the date of the reference
document is given, only that edition applies, and any newer edition and subsequent amendments do not apply. If the date
of the reference document is not given, the latest edition including the amendments applies.
Further information on the reference documents, including how to obtain copies, can be found on the following internet
sites:
http://www.jisc.go.jp/
http://www.iec.ch
http://www.iso.org
http://www.itu.int

JIS B 0205-2, ISO general purpose metric screw threads - Part2: General plan

NOTE Corresponding IS: ISO 261, ISO general purpose metric screw threads General plan (IDT)
JIS B 0205-3, ISO general purpose metric screw threads - Part3 : Selected sizes for screws, bolts and nuts

NOTE Corresponding IS: ISO 262 ISO general purpose metric screw threads - Selected sizes for screws, bolts and nuts
(IDT)
JIS C 0448, Coding of indicating devices and actuators by colours and supplementary means
NOTE Corresponding IS: IEC 60073, Basic and safety principles for man-machine interface, marking and identification -
Coding principles for indicator devices and actuators (IDT)
JIS C 2134, Method for the determination of the proof and the comparative tracking indices of solid insulating materials
NOTE Corresponding IS: IEC 60112, Method for the determination of the proof and the comparative tracking indices of
insulating materials (IDT)
JIS C 3215 (all parts), Specifications for particular types of winding wires
NOTE Corresponding IS: IEC 60317 (all parts), Specifications for particular types of winding wires (IDT)

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 49 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
JIS C 3661-1:1998, Electrical test methods for electric cables - Part 1: Electrical tests for cables, cords and wires for
voltages up to and including 450/750V
NOTE Corresponding IS: IEC 60885-1:1987, Electrical test methods for electric cables. Part 1: Electrical tests for cables,
cords and wires for voltages up to and including 450/750 V (IDT)
JIS C 3662 (all parts), Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 1 : General
requirements
NOTE Corresponding IS: IEC 60227 (all parts), Polyvinyl chloride insulated cables of rated voltages up to and including
450/750 V (MOD)
JIS C 3663 (all parts), Rubber insulated cables - Rated voltages up to and including 450/750 V
NOTE Corresponding IS: IEC 60245 (all parts), Rubber insulated cables - Rated voltages up to and including 450/750 V
(MOD)
JIS C 4003, Electrical insulation-Thermal evaluation and designation
NOTE Corresponding IS: IEC 60085:2004, Electrical insulation - Thermal classification (MOD)
JIS C 4526-1:2005, Switches for appliances - Part 1: General requirements
NOTE Corresponding IS: IEC 61058-1:2000, Switches for appliances - Part 1: General requirements (MOD)
JIS C 5101-14:2009, Fixed capacitors for use in electronic equipment - Part 14: Sectional specification: Fixed capacitors
for electromagnetic interference suppression and connection to the supply mains
NOTE Corresponding IS: IEC 60384-14:2005, Fixed capacitors for use in electronic equipment - Part 14: Sectional
specification: Fixed capacitors for electromagnetic interference suppression and connection to the supply mains (IDT)
JIS C 6065:2007 and Amendment 1:2009, Audio, video and similar electronic apparatus - Safety requirements
NOTE Corresponding IS: IEC 60065:2001, Audio, video and similar electronic apparatus - Safety requirements and
Amendment 1:2005 (MOD)
JIS C 6802, Safety of laser products
JIS C 6803, Safety of laser products-Safety of optical fiber communication systems
JIS C 6804, Safety of laser products-Safety of free space optical communication systems used for transmission of
information
NOTE Corresponding IS: IEC 60825-12, Safety of laser products - Part 12: Safety of free space optical communication
systems used for transmission of information (IDT)
JIS C 8201-1:2007, Low-voltage switchgear and controlgear-Part 1: General rules
NOTE Corresponding IS: IEC 60947-1:2004, Low-voltage switchgear and controlgear - Part 1: General rules (MOD)
JIS C 8283 (all parts), Appliance couplers for household and similar general purposes
NOTE Corresponding IS: IEC 60320 (all parts), Appliances couplers for household and similar general purposes (MOD)
JIS C 8285, Plugs, socket-outlets and couplers for industrial purposes
NOTE Corresponding IS: IEC 60309-1, Plugs, socket-outlets and couplers for industrial purposes - Part 1: General
requirements (MOD)
JIS C 8303, Plugs and receptacles for domestic and similar general use
JIS C 8358:1994, Appliance couplers for domestic and similar use
JIS C 9730-1:2010, Automatic electrical controls for household and similar use - Part 1:General requirements
NOTE Corresponding IS: IEC 60730-1:1999, Automatic electrical controls for household and similar use - Part 1: General
requirements and Amendment 1:2003 (MOD)
JIS C 60068-2-78, Environmental testing - Test Cab:Damp heat,steady state
NOTE Corresponding IS: IEC 60068-2-78, Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
(IDT)
JIS C 60364-1:2006, Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general
characteristics, definitions
NOTE Corresponding IS: IEC 60364-1:2001, Electrical installations of buildings - Part 1: Fundamental principles,
assessment of general characteristics, definitions (IDT)
JIS C 60664-1:2009, Insulation coordination for equipment within low-voltage systems - Part 1:Principles,requirements
and tests
NOTE Corresponding IS: IEC 60664-1:1992, Insulation coordination for equipment within low-voltage systems - Part 1:
Principles, requirements and tests, Amendment 1:2000 and Amendment 2:2002 (IDT)
JIS C 60695-2-11, Fire hazard testing - Glow-wire flammability test method for end-products
TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
NOTE Corresponding IS: IEC 60695-2-11, Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-
wire flammability test method for end-products (IDT)
Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
- -
JIS C 60695-2-20, Fire hazard testing Part 2 : Glowing /Hot wire based test methods Section 20 : Hot-wire coil
ignitability test on materials
NOTE Corresponding IS: IEC/TS 60695-2-20, Fire hazard testing - Part 2-20: Glowing/hot wire based test methods - Hot-
Page 50 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
JIS C 60695-10-2, Fire hazard testing-Part 10-2: Abnormal heat-Ball pressure test
NOTE Corresponding IS: IEC 60695-10-2, Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test (IDT)
JIS C 60695-11-5:2007, Fire hazard testing-Part 11-5:Test flames-Needle-flame test method - Apparatus, confirmatory
test arrangement and guidance
NOTE Corresponding IS: IEC 60695-11-5:2004, Fire hazard testing - Part 11-5: Test flames - Needle-flame test method -
Apparatus, confirmatory test arrangement and guidance (IDT)
JIS C 60695-11-10, Fire hazard testing-Part 11-10:Test flames - 50 W horizontal and vertical flame test methods
NOTE Corresponding IS: IEC 60695-11-10, Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical
flame test methods (IDT)
JIS C 60695-11-20, Fire hazard testing-Part 11-20: Test flames - 500 W flame test methods
NOTE Corresponding IS: IEC 60695-11-20, Fire hazard testing - Part 11-20: Test flames - 500 W flame test methods
(IDT)
JIS K 7110, Plastics - Determinaion of Izod impact strength
NOTE Corresponding IS: ISO 180, Plastics - Determination of Izod impact strength (MOD)
JIS K 7111 (all parts), Plastics-Determination of Charpy impact properties - Part 1: Non-instrumented impact test
NOTE Corresponding IS: ISO 179 (all parts), Plastics - Determination of Charpy impact properties (MOD)

JIS K 7127, Plastics - Determination of tensile properties Part 3 : Test conditions for films and sheets
NOTE Corresponding IS: ISO 527-3, Plastics - Determination of tensile properties - Part 3: Test conditions for films and
sheets (IDT)

JIS K 7160, Plastics Determination of tensile-impact strength
NOTE Corresponding IS: ISO 8256, Plastics - Determination of tensile-impact strength (IDT)
- -
JIS K 7161, Plastics Determination of tensile properties Part 1 : General principles
NOTE Corresponding IS: ISO 527-1, Plastics - Determination of tensile properties - Part 1: General principles (IDT)
JIS K 7162, Plastics - Determination of tensile properties - Part 2 : Test conditions for moulding and extrusion plastics
NOTE Corresponding IS: ISO 527-2, Plastics - Determination of tensile properties - Part 2: Test conditions for moulding
and extrusion plastics (IDT)
JIS K 7164, Plastics - Determination of tensile properties - Test conditions for isotropic and orthotropic fibre-reinforced
plastic composites
NOTE Corresponding IS: ISO 527-4, Plastics - Determination of tensile properties - Part 4: Test conditions for isotropic
and orthotropic fibre-reinforced plastic composites (MOD)
JIS K 7165, Plastics-Determination of tensile properties-Part 5: Test conditions for unidirectional fibre-reinforced plastic
composites
NOTE Corresponding IS: ISO 527-5, Plastics - Determination of tensile properties - Part 5: Test conditions for
unidirectional fibre-reinforced plastic composites (MOD)
JIS K 7171, Plastics - Determination of flexural properties
NOTE Corresponding IS: ISO 178, Plastics - Determination of flexural properties (IDT)
JIS K 7241, Cellular plastics-Determination of horizontal burning characteristics of small specimens subjected to a small
flame
NOTE Corresponding IS: ISO 9772, Cellular plastics - Determination of horizontal burning characteristics of small
specimens subjected to a small flame (IDT)
JIS K 7341, Plastics-Determination of burning behaviour of thin flexible vertical specimens in contact with a small-flame
ignition source
NOTE Corresponding IS: ISO 9773, Plastics - Determination of burning behaviour of thin flexible vertical specimens in
contact with a small-flame ignition source (IDT)
JIS K 7350-1, Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance
NOTE Corresponding IS: ISO 4892-1, Plastics - Methods of exposure to laboratory light sources - Part 1: General
guidance (IDT)
JIS K 7350-2, Plastics - Methods of exposure to laboratory light sources - Part 2 : Xenon-arc lamps
NOTE Corresponding IS: ISO 4892-2, Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc
lamps (MOD)
JIS K 7350-4, Plastics - Methods of exposure to laboratory light sources - Part 4: Open-flame carbon-arc lamps
NOTE Corresponding IS: ISO 4892-4, Plastics - Methods of exposure to laboratory light sources - Part 4: Open-flame
carbon-arc lamps (MOD) TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
JIS S 0101:2000, Graphical warning symbols for consumers
Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
TS C 60695-11-3, Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test
methods
NOTE Corresponding IS: IEC 60695-11-3, Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and
confirmational test methods (IDT)
Page 51 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
TS C 60695-11-4, Fire hazard testing - Part 11-4: Test flames - 50 W flames - Apparatus and confirmational test methods
NOTE Corresponding IS: IEC 60695-11-4, Fire hazard testing - Part 11-4: Test flames - 50 W flames - Apparatus and
confirmational test methods (IDT)
IEC 60216-4-1, Electrical insulating materials - Thermal endurance properties - Part 4-1: Ageing ovens - Single-chamber
ovens
IEC 60309 (all parts), Plugs, socket-outlets and couplers for industrial purposes
IEC 60317 (all parts), Specifications for particular types of winding wires
IEC 60317-43, Specifications for particular types of winding wires - Part 43: Aromatic polyimide tape wrapped round
copper wire, class 240
IEC 60320 (all parts), Appliance couplers for household and similar general purposes
IEC 60417-DB:2002, Graphical symbols for use on equipment
(For DB, see the online database of the IEC.)
IEC 60747-5-5, Semiconductor devices - Discrete devices - Part 5-5: Optoelectronic devices – Photocouplers
IEC 60825-1, Safety of laser products - Part 1: Equipment classification and requirements
IEC 60825-2, Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS)
IEC/TR 60825-9, Safety of laser products - Part 9: Compilation of maximum permissible exposure to incoherent optical
radiation
IEC 60851-3:1996, Winding wires - Test methods - Part 3: Mechanical properties and Amendment 1:1997
IEC 60851-5:1996, Winding wires - Test methods - Part 5: Electrical properties, Amendment 1:1997 and Amendment
2:2004
IEC 60851-6:1996, Methods of test for winding wires - Part 6: Thermal properties
IEC 60947-1:2004, Low-voltage switchgear and controlgear - Part 1: General rules
IEC 60990:1999, Methods of measurement of touch current and protective conductor current
IEC 61051-2, Varistors for use in electronic equipment - Part 2: Sectional specification for surge suppression varistors
ISO 180, Plastics - Determination of Izod impact strength
ISO 4892-1, Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance
ISO 7000-DB:2004, Graphical symbols for use on equipment - Index and synopsis
(For DB, see the online database of the IEC.)
ISO 8256, Plastics - Determination of tensile-impact strength
ITU-T Recommendation K.44, Resistibility tests for telecommunication equipment exposed to overvoltages and
overcurrents - Basic Recommendation

Annex Replace the existing NOTE as NOTE1, add Replaced. P


U.2.4 NOTE 2 as follows:
NOTE 2 by taking into account environmental
impact, “(for example, 1.1.1-trichloroethance)”
described in the corresponding IEC standard was
deleted.
Annex V.1 Replace “In 3.1.2 of IEC 60364-1” with “312 of JIS Replaced. P
C 60364-1”.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 52 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
Annex W.1 Replace second and third sentence in the first Replaced. N/A
paragraph with the following:
This distinction between earthed and unearthed
(floating) circuit is not the same as between
CLASS I EQUIMENT, CLASS 0I EQUIPMENT
and CLASS II EQUIPMENT. Floating circuits can
exist in CLASS I EQUIPMENT or CLASS 0I
EQUIPMENT and earthed circuits in CLASS II
EQUIPMENT.
Annex AA Replace figure AA.3 which correct the position of Replaced. N/A
insulating metal sheet.
Annex JA Add a new annex JA with the following contents. Not document shredding N/A
machine.
Annex JA
(normative)
Requirements for document shredding machines
(see 1.7, 2.8.3, 3.4 and 4.4)
Introduction
This annex specifies the safety requirements for
document shredding machines, except those of
STATIONARY EQUIPMENT used by connecting
directly to 3-phase AC MAINS SUPPLY of a
voltage not the than 200V.
Document shredding machines shall comply with
the requirements of this annex in addition to other
requirements specified in this standard, except
those of STATIONARY EQUIPMENT used by
connecting directly to three-phase AC MAINS
SUPPLY of a voltage not less than 200V.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 53 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
JA.1 Markings and instructions N/A
In the easily visible part near to the slot for
documents, by a method of clearly legible and
permanent and by using easily understandable
terms, document shredding machines shall have
markings of the symbol specified in 6.2.1
(general cautions) of JIS S 0101:2000, Graphical
warning symbols for consumers, and also the
following precautions for use:
- that use by an infants/children may cause a
hazard of injury etc.;
- that a hand can be drawn into the mechanical
section for shredding when touching the
document-slot;
- that clothing can be drawn into the mechanical
section for shredding when touching the
document-slot;
- that hairs can be drawn into the mechanical
section for shredding when touching the
document-slot;
- in case of equipment incorporating a
commutator motor, that equipment may catch
fire or explode by spraying of flammable gas.
JA.2 Inadvertent reactivation N/A
Any safety interlock that can be operated by
means of the test finger, Figure JA.1, is
considered to be likely to cause inadvertent
reactivation of the hazard.
Compliance is checked by inspection and, where
necessary, by a test with the test finger, Figure
JA.1

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 54 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
JA.3 Disconnect switch N/A
Document shredding machines shall incorporate
an isolating switch complying with sub-clause
3.4.2 as the device disconnecting the power of
hazardous moving parts. For this switch, two-
position (single-use) switch or multi-position
(multifunction) switch (e.g., slide switch) may be
used.
If two-position switch, the positions for “ON” and
“OFF” shall be indicated in accordance with sub-
clause 1.7.8. If multi-position switch, the position
for “OFF” shall be indicated in accordance with
sub-clause 1.7.8 and other positions shall be
indicated with proper terms or symbols.
Compliance is checked by inspection.
JA.4 Protection in operator access area N/A
Any warning shall not be used instead of the
structure for preventing access to hazardous
moving parts.
Document shredding machines shall comply with
the following requirements.
Insert the test finger, Figure JA.1, into all
openings in MECHANICAL ENCLOSURES
without applying appreciable force. It shall not be
possible to touch hazardous moving parts with
the test finger. This consideration applies to all
sides of MECHANICAL ENCLOSURES when the
equipment is mounted as intended . Before
testing with the test finger, remove the parts
detachable without a tool.
Insert the wedge-probe, Figure JA.2, into the
document-slot. And, against all directions of
openings, if straight-cutting type, a force of 45 N
shall apply to the probe, and 90 N if cross-cutting
type. In this case, the weight of the probe is to be
factored into the overall applied force. Before
testing with the wedge-probe, remove the parts
detachable without a tool. It shall not be possible
to touch any hazardous moving parts, including
the shredding roller or the mechanical section for
shedding, with the probe.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 55 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)

Figure JA.1 Test finger

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 56 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)

Details of the tip of wedge

Dimensions in millimeters
Distance from the tip Thickness of probe
0 2
12 4
180 24

The thickness of the probe varies linearly, except changing the slope at the respective points shown in the table.
The allowable dimensional tolerance of the probe shall be +/- 0,127 mm.

Figure JA.2 Wedge-probe.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 57 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
Annex JB Add Annex JB as follows: N/A

Annex JB
(informative)
Current conditions Installation environment on
overvoltages and overcurrents, and the measures
(see NOTE 1 in Clause 6)
Introduction
This standard is based on “ITU-T
Recommendation K.11:1993” to stipulate
requirement for equipment on a premise to install
in the environment where appropriate measures
were taken for so that overvoltage more than
peak 1.5kV does not hang to the apparatus. But
in Japan due to environment is difficult to
integrate with “ITU-T Recommendation
K.11:1993”, in here explain for desirable
environment and show actions to be taken how to
make a desirable setting environment.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 58 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)
JB.1 A desirable setting environment N/A
When lead electric wires in building for any kind
service of metal wire, for overvoltage restraint and
overcurrent restraint, it is desirable that be close to
each other including grounding conductor. It is
important to make it close each other especially the
lead in point of power line, communication line and
grounding conductor. In that case, attention is
necessary for electromagnetic induction where
occurred between a communication line and the
power line which are not covered. It is desirable
that set up main grounding terminal which close to
lead in point of power line and communication line
in building as much as possible. Due to minimize
the surge current in building for all shielding
conductor of cable which lead in building, it shall
connected directly with main grounding terminal in
lead in point via surge protection device (SPD) e.g.
arrester and so on. It shall be considered corrosion
measures in joint if necessary.
It is desirable that SPD which set on
communication line is close to lead in point
toward the building as much as possible.
Furthermore set the SPD near the main power
line, and it may make the distance from SPD to a
grounding conductor as short as possible. It is
effective if use a short grounding conductor with
low impedance for that decrease surge voltage
between electric power system protection
conductor and the communication line.
Desirable setting environment for TT electric N/A
power system is as figure JB.1. Established SPD
as that excessive potential difference does not
occur between communication side and the
electricity side, and recommend that ground wire
of both are connected with a short conductor.
Concerning the detail for recommend setting
environment, see
ITU-T Recommendation K.11:1993, K.21:1996,
K.27:1996, K.31:1993 and K.66:2004.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 59 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)

Note:
a) All bonding line to a main grounding terminal makes it as short as possible (Less than 1.5m in the place that
danger of direct lightning is high).
b) The connected line which from SPD to main grounding terminal is as short as possible (less 1.5m).
c) Setting for SPD (omitted the detail). All SPD connected line is short as possible (less 0.5m).

Figure JB.1 – Sample of desirable setting for TT electric power system of single phase three-wire type + neutral
line
(From ITU-T Recommendation K.66:2004)

JB.2 Situation and countermeasure of setting N/A


environment for overvoltage and overcurrent
In Japan, TT type often adopted for electric power
system. Typical example is as figure JB.2. For
this TT type, on condition that it shall be an
electric power system which does not wired with
grounding conductor except neutral line, and it
shall be connected with grounding terminal which
have an electrically independent different from
this grounding terminal of neutral line by user for
equipment which need to connect with ground.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 60 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)

Grounded electric wire and grounded equipment in particularly

Figure JB.2 – Example of three-wire type TT electric power system

But as thing are stand, there are a lot of cases that N/A
an outlet is not prepared with the grounding
terminal which is appropriate in the setting place of
the equipment. On the other hand, grounding
resistance value of SPD where set at lead-in point
of communication line sometime is not enough low,
it make that dielectric breakdown was occurred
due to the voltage that a thunder surge current
evoked for grounding resistance which flow into the
communication line and drift to the ground through
SPD. The same result is expected that grounding
resistance value is not enough low too if set SPD
on electric power system. This status is as figure
JB.3.
As figure JB.1, it can decrease effectively by
connecting both with the conductor of the low
resistance value when excessive potential
difference occurred in internal equipment.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 61 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

J 60950-1(H26)
(Deviations from IEC 60950-1:2005, second edition)
Special National conditions, National deviation and other information according to MITI Ordinance No. 85.
Japanese unique deviations in J60950-1(H26) (=JIS C 6950-1:2012)

Figure JB.3 - Insufficient grounding and setting environment of bonding


(From ITU-T Recommendation K.66:2004)

It is desirable that provide the information for set N/A


environment which appropriate measures were
given based on
ITU-T RecommendationK.11:1993 when
perform design and sale network connected
equipment.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 62 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

KR Republic of Korea KR
1.5.101 Addition N/A
Plugs for the connection of the apparatus to the
supply mains shall comply with the Korean
requirement (KSC 8305).
8 Addition N/A
EMC The apparatus shall comply with the relevant
CISPR standards

SE Sweden SE
1.2.13.14 In Norway and Sweden, for requirements see N/A
1.7.2.1 and 7.3 of this annex.
1.5.1 Sweden (Ordinance 1990:944) N/A
Add the following:
NOTE In Sweden, switches containing mercury
are not permitted.
1.5.7.1 In Finland, Norway and Sweden, resistors N/A
bridging BASIC INSULATION in CLASS I PLUGGABLE
EQUIPMENT TYPE A must comply with the
requirements in 1.5.7.1. In addition when a single
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
1.5.9.4 In Finland, Norway and Sweden, the third dashed N/A
sentence is applicable only to equipment as
defined in 6.1.2.2 of this annex.
1.7.2.1 In Finland, Norway and Sweden, CLASS I N/A
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall,
if safety relies on connection to protective earth or
if surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall N/A
be as follows:
In Finland:
"Laite on liitettävä suojamaadoituskoskettimilla
varustettuun pistorasiaan"
In Norway:
“Apparatet må tilkoples jordet stikkontakt”
In Sweden:
“Apparaten skall anslutas till jordat uttag”

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 63 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

SE Sweden SE
1.7.2 In Norway and Sweden, the screen of the cable N/A
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of
a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective
earthing of the building installation through the
mains connection or through other equipment
with a connection to protective earthing – and
to a cable distribution system using coaxial
cable, may in some circumstances create a
fire hazard. Connection to a cable distribution
system has therefore to be provided through a
device providing electrical isolation below a
certain frequency range (galvanic isolator, see
EN 60728-11).”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60
Hz, for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr
– og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom
utstyret og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medfőra risk főr brand. Főr att
undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV
nätet.”
2.3.2 In Finland, Norway and Sweden there are N/A
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
2.10.5.13 In Finland, Norway and Sweden, there are N/A
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.
TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 64 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

SE Sweden SE
5.1.7.1 In Finland, Norway and Sweden TOUCH N/A
CURRENT measurement results exceeding 3,5
mA r.m.s. are permitted only for the following
equipment:
STATIONARY PLUGGABLE EQUIPMENT TYPE
A that is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential
bonding has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the installation of
that conductor by a SERVICE PERSON;
STATIONARY PLUGGABLE EQUIPMENT TYPE
B;
STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
6.1.2.1 In Finland, Norway and Sweden, add the N/A
following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of
which shall pass the electric strength test
below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the
electric strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do
not exist, if the component passes the electric
strength test in accordance with the compliance
clause below and in addition
- passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test
voltage of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 65 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

SE Sweden SE
A capacitor classified Y3 according to EN N/A
132400:1994, may bridge this insulation under
the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3
testing, is tested with an impulse test of 2,5
kV defined in EN 60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on
all the test specimens as described in EN
132400;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400, in
the sequence of tests as described in EN
132400.
6.1.2.2 In Finland, Norway and Sweden, the exclusions N/A
are applicable for PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE
B and equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR and is
provided with instructions for the installation of
that conductor by a SERVICE PERSON.
7.2 In Finland, Norway and Sweden, for requirements N/A
see 6.1.2.1 and 6.1.2.2 of this annex. The term
TELECOMMUNICATION NETWORK in 6.1.2
being replaced by the term CABLE
DISTRIBUTION SYSTEM.
7.3 In Norway and Sweden, there are many buildings N/A
where the screen of the coaxial cable is normally
not connected to the earth in the building
installation.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 66 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

UA Ukraine UA
1.4.5 In Ukraine the NOMINAL VOLTAGE is 220 V for Rated voltage: 100-240VAC P
monophase or 380 V for three-phase supply.

1.5.8 In Ukraine the components connected between N/A


phase and earthing or between phase and neutral
terminal shall be calculated for the voltage
between phases.
1.7.2 In Ukraine for the APPARATUS of I CLASS the N/A
necessity of its obligatory earthing shall be
indicated in the manuals.
2.3.3 In Ukraine the method b) is not used. N/A
6.2.2 In Ukraine the both tests in 6.2.2.1 and 6.2.2.2 are N/A
applied.
6.2.2.1 In Ukraine in 6.2.1 a) is used Uc = 3,5 kV. N/A
6.2.2.2 In Ukraine in 6.2.1 a) is used 3,0 kV for N/A
telephones and headsets and 2,5 kV - for other
equipment and in 6.2.1 b) and c) is used 1,5 kV.
Annex N In Ukraine in 6.2.1 a) is used 3,0 kV for N/A
telephones and headsets and 2,5 kV - for other
equipment, and in 6.2.1 b) and c) is used 1,5 kV.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 67 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

US United States of America US


SPECIAL NATIONAL CONDITIONS BASED ON FEDERAL REGULATIONS 
1.1.1 All equipment is to be designed to allow P
installation in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70, the
Canadian Electrical Code (CEC), Part I, CAN/CSA
C22.1, and when applicable, the National
Electrical Safety Code, IEEE C2. Also, unless
marked or otherwise identified, installation is
allowed per the Standard for the Protection of
Electronic Computer/Data-Processing Equipment,
ANSI/NFPA 75.
1.1.2 Baby monitors are required to additionally comply N/A
with ASTM F2951, Consumer Safety Specification
for Baby Monitors.
1.4.14 For Pluggable Equipment Type A, the protection P
in the installation is assumed to be 20A.
1.5.5 For lengths exceeding 3.05 m, external N/A
interconnecting flexible cord and cable assemblies
are required to be a suitable cable type (e.g., DP,
CL2) specified in the NEC.
For lengths 3.05 m or less, external
interconnecting flexible cord and cable assemblies
that are not types specified in the NEC are
required to have special construction features and
identification markings.
1.7.1 Equipment for use on a.c. mains supply systems N/A
with a neutral and more than one phase conductor
(e.g. 120/240 V, 3-wire) require a special marking
format for electrical ratings.
A voltage rating that exceeds an attachment plug
cap rating is only permitted if it does not exceed
the extreme operating conditions in Table 2 of
CAN/CSA C22.2 No. 235, and if it is part of a
range that extends into the Table 2 "Normal
Operating Conditions." Likewise, a voltage rating
shall not be lower than the specified "Normal
Operating Conditions," unless it is part of a range
that extends into the "Normal Operating
Conditions."
1.7.7 Wiring terminals intended to supply Class 2 N/A
outputs in accordance with the NEC or CEC Part
1 shall be marked with the voltage rating and
“Class 2” or equivalent. The marking shall be
located adjacent to the terminals and shall be
visible during wiring.
2.5 Where a fuse is used to provide Class 2, Limited N/A
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 68 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

US United States of America US


2.6 Equipment with isolated ground (earthing) N/A
receptacles are required to comply with NEC
250.146(D) and CEC 10-112 and 10-906(8).
2.7.1 Suitable NEC/CEC branch circuit protection rated N/A
at the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable. Power
distribution transformers distributing power at 100
volts or more, and rated 10 kVA or more, require
special transformer overcurrent protection.
3.2 Wiring methods (terminals, leads, etc.) used for N/A
the connection of the equipment to the mains shall
be in accordance with the NEC/CEC.
3.2.1 Power supply cords are required to have N/A
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
3.2.1.2 Equipment connected to a centralized d.c. power N/A
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
3.2.3 Permanent connection of equipment to the mains N/A
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
3.2.5 Power supply cords are required to be no longer N/A
than 4.5 m in length. Minimum cord length is
required to be 1.5 m, with certain constructions
such as external power supplies allowed to
consider both input and output cord lengths into
the requirement.
Flexible power supply cords are required to be
compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.
3.2.9 Permanently connected equipment is required to N/A
have a suitable wiring compartment and wire
bending space.
3.3 Wiring terminals and associated spacings for field N/A
wiring connections shall comply with CSA C22.2
No. 0.
3.3.3 Wire binding screws are not permitted to attach N/A
2
conductors larger than 10 AWG (5.3 mm ).
3.3.4 Terminals for permanent wiring, including N/A
protective earthing terminals, are required to be
suitable for U.S./Canadian wire gauge sizes, rated
125 percent of the equipment rating, and be
specially marked when specified (1.7.7).

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 69 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

US United States of America US


3.3.5 First column of Table 3E revised to require N/A
“Smaller of the RATED CURRENT of the
equipment or the PROTECTIVE CURRENT
RATING of the circuit under consideration.”
3.4.2 Motor control devices are required for cord- N/A
connected equipment with a motor if the
equipment is rated more than 12 A, or if the motor
has a nominal voltage rating greater than 120 V,
or is rated more than 1/3 hp (locked rotor current
over 43 A).
3.4.8 Vertically-mounted disconnect switches and N/A
circuit breakers are required to have the "on"
position indicated by the handle in the up position.
3.4.11 For computer room applications, equipment with N/A
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
4.3.12 The maximum quantity of flammable liquid stored N/A
in equipment is required to comply with NFPA30.
4.3.13.5. Equipment with lasers is required to meet the U.S. N/A
1 Code of Federal Regulations 21 CFR 1040 (and
the Canadian Radiation Emitting Devices Act,
REDR C1370).
4.7 For computer room applications, automated N/A
information storage systems with combustible
3
media greater than 0.76 m (27 cu ft) are required
to have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
4.7.3.1 For computer room applications, enclosures with N/A
combustible material measuring greater than 0.9
2
m (10 sq ft) or a single dimension greater than
1.8 m (6 ft) are required to have a flame spread
rating of 50 or less. For other applications,
enclosures with the same dimensions require a
flame spread rating of 200 or less.
Annex H Equipment that produces ionizing radiation is N/A
required to comply with the U.S. Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
OTHER NATIONAL DIFFERENCES 

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 70 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

US United States of America US


1.5.1 Some components and materials associated with (see appended table 1.5.1) P
the risk of fire, electric shock, or personal injury
are required to
have component or material ratings in accordance
with the applicable national (U.S. and Canadian)
component or material requirements. These
components include: attachment plugs, battery
packs (rechargeable type, used with transportable
equipment), cathode ray tubes, circuit breakers,
communication circuit accessories, connectors
(used for current interruption of non-LPS circuits),
cord sets and power supply cords, direct plug-in
equipment, electrochemical capacitor modules
(energy storage modules with ultracapacitors),
enclosures (outdoor), flexible cords and cables,
fuses (branch circuit), fuseholders, ground-fault
current interrupters, industrial control equipment,
insulating tape, interconnecting cables,
lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
protectors, switches (including interlock
switches), thermal cutoffs, thermostats, (multi-
layer) transformer winding wire, surge protective
devices, tubing, vehicle battery adapters, wire
connectors, and wire and cables.
1.6.1.2 A circuit for connection to the DC Mains Supply is N/A
classified as a SELV Circuit, a TNV-2 Circuit or a
Hazardous Voltage Circuit depending on the
maximum operating voltage of the supply. This
maximum operating voltage shall include
consideration of the battery charging “float
voltage” associated with the intended supply
system, regardless of the marked power rating of
the equipment.
2.3.1 For TNV-2 and TNV-3 circuits with other than N/A
ringing signals and with voltages exceeding 42.4
Vpeak or 60 Vd.c., the maximum acceptable
current through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA d.c.
under normal operating conditions.
2.3.2.1 In the event of a single fault between TNV and N/A
SELV circuits, the limits of 2.2.3 apply to SELV
Circuits and accessible conductive parts.
2.6.2 Equipment with functional earthing is required to N/A
be marked with the functional earthing symbol
(IEC 60417-6092).

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 71 of 71
Report No.: 085-110044304-000

Attachment No. 1
IEC60950-1
Clause Requirement + Test Result - Remark Verdict

US United States of America US


2.6.3.4 Protective bonding conductors of non-standard N/A
protective bonding constructions (e.g., printed
circuit traces) may be subjected to the additional
limited short circuit test conditions specified.
4.2.8.1 Enclosures around CRTs with a face diameter of N/A
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
4.3.2 Equipment with handles is required to comply with N/A
special loading tests.
5.1.8.3 Equipment intended to receive telecommunication N/A
ringing signals is required to comply with a special
touch current measurement tests.
5.3.7 Internal (e.g., card cage) SELV circuit connectors P
and printed wiring board connectors that are
accessible to the operator and that deliver power
are to be overloaded.
During abnormal operating testing, if a circuit is
interrupted by the opening of a component, the
test shall be repeated twice (three tests total)
using new components as necessary.
6.4 Equipment intended for connection to N/A
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
Annex UL articulated accessibility probe (Fig EE.3) N/A
EE required for assessing accessibility to
document/media shredders instead of the Figure
2A test finger.
Annex Continuous ringing signals up to 16 mA only are N/A
M.2 permitted if the equipment is subjected to special
installation and performance restrictions.
Annex Equipment connected to a telecommunication N/A
NAD and cable distribution networks and supplied with
an earphone intended to be held against, or in the
ear is required to comply with special acoustic
pressure requirements.

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch

Test Report National and Group Differences for IEC 60950-1 2nd Ed.+A1+A2 Rev. 07
Page 1 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 60950-1


EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Information technology equipment – Safety –
Part 1: General requirements
Differences according to................ : EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013
Attachment Form No. ..................... : EU_GD_IEC60950_1F
Attachment Originator ................... : SGS Fimko Ltd
Master Attachment ......................... : Date 2014-02
Copyright © 2014 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 – CENELEC COMMON MODIFICATIONS

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
Clauses, subclauses, notes, tables and figures which are additional to those in
IEC60950-1 and it´s amendmets are prefixed “Z”
Contents Add the following annexes: P
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Annex ZB (normative) Special national conditions
(A2:2013)
Annex ZD (informative) IEC and CENELEC code designations for
flexible cords
General Delete all the “country” notes in the reference document (IEC 60950-1:2005) P
according to the following list:
1.4.8 Note 2 1.5.1 Note 2 & 3 1.5.7.1 Note
1.5.8 Note 2 1.5.9.4 Note 1.7.2.1 Note 4, 5 & 6
2.2.3 Note 2.2.4 Note 2.3.2 Note
2.3.2.1 Note 2 2.3.4 Note 2 2.6.3.3 Note 2 & 3
2.7.1 Note 2.10.3.2 Note 2 2.10.5.13 Note 3
3.2.1.1 Note 3.2.4 Note 3. 2.5.1 Note 2
4.3.6 Note 1 & 2 4.7 Note 4 4.7.2.2 Note
4.7.3.1Note 2 5.1.7.1 Note 3 & 4 5.3.7 Note 1
6 Note 2 & 5 6.1.2.1 Note 2 6.1.2.2 Note
6.2.2 Note 6.2.2.1 Note 2 6.2.2.2 Note
7.1 Note 3 7.2 Note 7.3 Note 1 & 2
G.2.1 Note 2 Annex H Note 2
General Delete all the “country” notes in the reference document (IEC 60950- P
(A1:2010) 1:2005/A1:2010) according to the following list:
1.5.7.1 Note 6.1.2.1 Note 2
6.2.2.1 Note 2 EE.3 Note
Page 2 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
General Delete all the “country” notes in the reference document (IEC 60950- P
(A2:2013) 1:2005/A2:2013) according to the following list:
2.7.1 Note * 2.10.3.1 Note 2
6.2.2. Note
* Note of secretary: Text of Common Modification remains unchanged.
1.1.1 Replace the text of NOTE 3 by the following. N/A
NOTE 3 The requirements of EN 60065 may also be used to meet safety requirements for multimedia
(A1:2010) equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. For television sets EN
60065 applies.
1.3.Z1 Add the following subclause: N/A
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and
constructed as to present no danger when used
for its intended purpose, either in normal operating
conditions or under fault conditions, particularly
providing protection against exposure to
excessive sound pressures from headphones or
earphones.
NOTE Z1 A new method of measurement is described
in EN 50332-1, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations -
Part 1: General method for “one package equipment”,
and in EN 50332-2, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations -
Part 2: Guidelines to associate sets with headphones
coming from different manufacturers.
(A12:2011) In EN 60950-1:2006/A12:2011 N/A
Delete the addition of 1.3.Z1 / EN 60950-1:2006
Delete the definition 1.2.3.Z1 / EN 60950-1:2006
/A1:2010
1.5.1 Add the following NOTE: P
NOTE Z1 The use of certain substances in electrical
and electronic equipment is restricted within the EU:
see Directive 2002/95/EC.
(Added info*) New Directive 2011/65/11 *

1.7.2.1 In addition, for a PORTABLE SOUND SYSTEM, N/A


(A1:2010) the instructions shall include a warning that
excessive sound pressure from earphones and
headphones can cause hearing loss.
1.7.2.1 In EN 60950-1:2006/A12:2011 N/A
(A12.2011) Delete NOTE Z1 and the addition for Portable
Sound System.
Add the following clause and annex to the existing
standard and amendments.
Page 3 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
Zx Protection against excessive sound pressure from personal music N/A
players
Zx.1 General N/A
This sub-clause specifies requirements for
protection against excessive sound pressure from
personal music players that are closely coupled to
the ear. It also specifies requirements for
earphones and headphones intended for use with
personal music players.

A personal music player is a portable equipment 


for personal use, that:
− is designed to allow the user to listen to
recorded or broadcast sound or video; and
− primarily uses headphones or earphones that
can be worn in or on or around the ears; and
− allows the user to walk around while in use.
NOTE 1 Examples are hand-held or body-worn portable CD
players, MP3 audio players, mobile phones with MP3 type
features, PDA’s or similar equipment.

A personal music player and earphones or


headphones intended to be used with personal
music players shall comply with the requirements
of this sub-clause.

The requirements in this sub-clause are valid for


music or video mode only.

The requirements do not apply:


− while the personal music player is connected to
an external amplifier; or
− while the headphones or earphones are not
used.
NOTE 2 An external amplifier is an amplifier which is not part
of the personal music player or the listening device, but which
is intended to play the music as a standalone music player.

The requirements do not apply to:


− hearing aid equipment and professional
equipment;
NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through normal
electronics stores are considered not to be professional
equipment.
Page 4 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
− analogue personal music players (personal N/A
music players without any kind of digital
processing of the sound signal) that are brought
to the market before the end of 2015.
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that within a
few years it will no longer exist. This exemption will not be
extended to other technologies.

For equipment which is clearly designed or


intended for use by young children, the limits of
EN 71-1 apply.
Zx.2 Equipment requirements N/A
No safety provision is required for equipment that
complies with the following:
− equipment provided as a package (personal
music player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA measured
while playing the fixed “programme simulation
noise” as described in EN 50332-1; and
− a personal music player provided with an
analogue electrical output socket for a listening
device, where the electrical output is ≤ 27 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
as described in EN 50332-1.
NOTE 1 Wherever the term acoustic output is used in this
clause, the 30 s A-weighted equivalent sound pressure level
LAeq,T is meant. See also Zx.5 and Annex Zx.

All other equipment shall:


a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and
automatically return to an output level not
exceeding those mentioned above when the
power is switched off; and
Page 5 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
c) provide a means to actively inform the user of N/A
the increased sound pressure when the
equipment is operated with an acoustic output
exceeding those mentioned above. Any means
used shall be acknowledged by the user before
activating a mode of operation which allows for
an acoustic output exceeding those mentioned
above. The acknowledgement does not need to
be repeated more than once every 20 h of
cumulative listening time; and
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening
time, independent how often and how long the personal music
player has been switched off.
d) have a warning as specified in Zx.3; and
e) not exceed the following:
1) equipment provided as a package (player
with Its listening device), the acoustic output
shall be ≤ 100 dBA measured while playing the
fixed “programme simulation noise” described
in EN 50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
described in EN 50332-1.
For music where the average sound pressure
(long term LAeq,T) measured over the duration of
the song is lower than the average produced by
the programme simulation noise, the warning
does not need to be given as long as the average
sound pressure of the song is below the basic limit
of 85 dBA. In this case T becomes the duration of
the song.
NOTE 4 Classical music typically has an average sound
pressure (long term LAeq,T) which is much lower than the
average programme simulation noise. Therefore, if the player
is capable to analyse the song and compare it with the
programme simulation noise, the warning does not need to be
given as long as the average sound pressure of the song is
below the basic limit of 85 dBA.
For example, if the player is set with the programme simulation
noise to 85 dBA, but the average music level of the song is
only 65 dBA, there is no need to give a warning or ask an
acknowledgement as long as the average sound level of the
song is not above the basic limit of 85 dBA.
Page 6 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict

Zx.3 Warning N/A


The warning shall be placed on the equipment, or
on the packaging, or in the instruction manual and
shall consist of the following:
− the symbol of Figure 1 with a minimum height of
5 mm; and
− the following wording, or similar:

“To prevent possible hearing damage, do not


listen at high volume levels for long periods.”

Figure 1 – Warning label (IEC 60417-6044)

Alternatively, the entire warning may be given


through the equipment display during use, when
the user is asked to acknowledge activation of the
higher level.
Zx.4 Requirements for listening devices (headphones and earphones) N/A
Zx.4.1 Wired listening devices with analogue N/A
input
With 94 dBA sound pressure output LAeq,T, the
input voltage of the fixed “programme simulation
noise” described in EN 50332-2 shall be ≥ 75 mV.

This requirement is applicable in any mode where


the headphones can operate (active or
passive), including any available setting (for
example built-in volume level control).

NOTE The values of 94 dBA – 75 mV correspond with 85dBA


– 27 mV and 100 dBA – 150 mV.
Page 7 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
Zx.4.2 Wired listening devices with digital N/A
input
With any playing device playing the fixed
“programme simulation noise” described in EN
50332-1 (and respecting the digital interface
standards, where a digital interface standard
exists that specifies the equivalent acoustic level),
the acoustic output LAeq,T of the listening device
shall be ≤ 100 dBA.

This requirement is applicable in any mode where


the headphones can operate, including any
available setting (for example built-in volume level
control, additional sound feature like equalization,
etc.).

NOTE An example of a wired listening device with digital input


is a USB headphone.

Zx.4.3 Wireless listening devices N/A


In wireless mode:
− with any playing and transmitting device playing
the fixed programme simulation noise described
in EN 50332-1; and
− respecting the wireless transmission standards,
where an air interface standard exists that
specifies the equivalent acoustic level; and
− with volume and sound settings in the listening
device (for example built-in volume level control,
additional sound feature like equalization, etc.)
set to the combination of positions that
maximize the measured acoustic output for the
abovementioned programme simulation noise,
the acoustic output LAeq,T of the listening device
shall be ≤ 100 dBA.

NOTE An example of a wireless listening device is a Bluetooth


headphone.

Zx.5 Measurement methods N/A


Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable.
Unless stated otherwise, the time interval T shall
be 30 s.

NOTE Test method for wireless equipment provided without


listening device should be defined.
Page 8 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
2.7.1 Replace the subclause as follows: N/A
Basic requirements
To protect against excessive current, short-circuits
and earth faults in PRIMARY CIRCUITS,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a), b)
and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as parts of
the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and
earth fault protection may be provided by
protective devices in the building installation;
c) it is permitted for PLUGGABLE EQUIPMENT N/A
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent
and short-circuit protection in the building
installation, provided that the means of protection,
e.g. fuses or circuit breakers, is fully specified in
the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded
as providing protection in accordance with the
rating of the wall socket outlet.
2.7.2 This subclause has been declared ‘void’. N/A
3.2.3 Delete the NOTE in Table 3A, and delete also in N/A
this table the conduit sizes in parentheses.
3.2.5.1 Replace “60245 IEC 53” by “H05 RR-F”; N/A
“60227 IEC 52” by “H03 VV-F or
H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05 VVH2-F2”.
In Table 3B, replace the first four lines by the
following:
a)
Up to and including 6 | 0,75 |
b)
Over 6 up to and including 10| (0,75) 1,0 |
c)
Over 10 up to and including 16| (1,0) 1,5 |
In the conditions applicable to Table 3B delete the
a)
words “in some countries” in condition .
In NOTE 1, applicable to Table 3B, delete the
second sentence.
Page 9 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
NOTE Z1 The harmonised code designations
3.2.5.1 corresponding to the IEC cord types are given in Annex ZD
N/A
(A2:2013)

3.3.4 In Table 3D, delete the fourth line: conductor sizes N/A
for 10 to 13 A, and replace with the following:
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to
4 |
Delete the fifth line: conductor sizes for 13 to 16 A
4.3.13.6 Replace the existing NOTE by the following: N/A
(A1:2010) NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the
limitation of exposure of the general public to
electromagnetic fields 0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and
safety requirements regarding the exposure of workers
to risks arising from physical agents (artifical optical
radiation).
Standards taking into account mentioned N/A
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are
indicated in the OJEC.
Annex H Replace the last paragraph of this annex by: N/A
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall
not exceed 1 µSv/h (0,1 mR/h) (see NOTE).
Account is taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2.
Bibliography Additional EN standards. 

ZA NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH 


THEIR CORRESPONDING EUROPEAN PUBLICATIONS

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.2.4.1 In Denmark, certain types of Class I appliances N/A
(see 3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
1.2.13.14 In Norway and Sweden, for requirements see N/A
(A11:2009) 1.7.2.1 and 7.3 of this annex.
Page 10 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.5.7.1 In Finland, Norway and Sweden, resistors N/A
(A11:2009) bridging BASIC INSULATION in CLASS I PLUGGABLE
EQUIPMENT TYPE A must comply with the
requirements in 1.5.7.1. In addition when a single
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
1.5.8 In Norway, due to the IT power system used (see P
annex V, Figure V.7), capacitors are required to
be rated for the applicable line-to-line voltage
(230 V).
1.5.9.4 In Finland, Norway and Sweden, the third N/A
dashed sentence is applicable only to equipment
as defined in 6.1.2.2 of this annex.
Page 11 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.7.2.1 In Finland, Norway and Sweden, CLASS I N/A
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall,
if safety relies on connection to protective earth or
if surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”

1.7.2.1 In Norway and Sweden, the screen of the cable


(A11:2009) distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of
a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
60728-11).”
Page 12 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
NOTE In Norway, due to regulation for installations of cable N/A
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det
ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret
og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV
nät kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning
av utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
1.7.2.1 In Denmark, CLASS I PLUGGABLE N/A
(A2:2013) EQUIPMENT TYPE A intended for connection to
other equipment or a network shall, if safety relies
on connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in Denmark shall be as follows:
In Denmark: “Apparatets stikprop skal tilsluttes
en stikkontakt med jord, som giver forbindelse til
stikproppens jord.”
1.7.5 In Denmark, socket-outlets for providing power to N/A
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet
shall be in accordance with Standard Sheet DK 1-
1b or DK 1-5a.
1.7.5 For CLASS II EQUIPMENT the socket outlet shall be
(A11:2009)
in accordance with Standard Sheet DKA 1-4a.
Page 13 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.7.5 In Denmark, socket-outlets for providing power to N/A
(A2:2013) other equipment shall be in accordance with the
DS 60884-2-D1:2011.
For class I equipment the following Standard
Sheets are applicable: DK 1-3a, DK 1-1c,
DK 1-1d, DK 1-5a or DK 1-7a, with the exception
for STATIONARY EQUIPMENT where the
socket-outlets shall be in accordance with
Standard Sheet DK 1-1b, DK 1-1c, DK 1-1d or
DK 1-5a.
Socket outlets intended for providing power to
Class II apparatus with a rated current of 2,5 A
shall be in accordance with DS 60884-2-D1
standard sheet DKA 1-4a. Other current rating
socket outlets shall be in compliance with by
DS 60884-2-D1 Standard Sheet DKA 1-3a or
DKA 1-3b.
Justification
the Heavy Current Regulations, 6c
2.2.4 In Norway, for requirements see 1.7.2.1, 6.1.2.1 N/A
and 6.1.2.2 of this annex.
2.3.2 In Finland, Norway and Sweden there are N/A
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
2.3.4 In Norway, for requirements see 1.7.2.1, 6.1.2.1 N/A
and 6.1.2.2 of this annex.
2.6.3.3 In the United Kingdom, the current rating of the N/A
circuit shall be taken as 13 A, not 16 A.
2.7.1 In the United Kingdom, to protect against P
excessive currents and short-circuits in the
PRIMARY CIRCUIT of DIRECT PLUG-IN
EQUIPMENT, tests according to 5.3 shall be
conducted, using an external protective device
rated 30 A or 32 A. If these tests fail, suitable
protective devices shall be included as integral
parts of the DIRECT PLUG-IN EQUIPMENT, so
that the requirements of 5.3 are met.
2.10.5.13 In Finland, Norway and Sweden, there are N/A
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.
Page 14 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
3.2.1.1 In Switzerland, supply cords of equipment having N/A
a RATED CURRENT not exceeding 10 A shall be
provided with a plug complying with SEV 1011 or
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2.1991 Plug Type 15 3P+N+PE
250/400 V, 10 A
SEV 6533-2.1991 Plug Type 11 L+N
250 V, 10 A
SEV 6534-2.1991 Plug Type 12 L+N+PE
250 V, 10 A
In general, EN 60309 applies for plugs for
currents exceeding 10 A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998:
SEV 5932-2.1998: Plug Type 25 , 3L+N+PE
230/400 V, 16 A

SEV 5933-2.1998:Plug Type 21, L+N, 250 V, 16A

SEV 5934-2.1998: Plug Type 23, L+N+PE 250 V,


16 A
3.2.1.1 In Denmark, supply cords of single-phase N/A
equipment having a rated current not
exceeding13 A shall be provided with a plug
according to the Heavy Current Regulations,
Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with standard sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord
with a plug, this plug shall be in accordance with
the Heavy Current Regulations, Section 107-2-D1
or EN 60309-2.
Page 15 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
3.2.1.1 In Denmark, supply cords of single-phase N/A
(A2:2013) equipment having a rated current not exceeding
13 A shall be provided with a plug according to
DS 60884-2-D1.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with standard sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a poly-phase
equipment is provided with a supply cord with a
plug, this plug shall be in accordance with the
standard sheets DK 6-1a in DS 60884-2-D1 or
EN 60309-2.
Justification
the Heavy Current Regulations, 6c
3.2.1.1 In Spain, supply cords of single-phase equipment N/A
having a rated current not exceeding 10 A shall
be provided with a plug according to UNE
20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to UNE-EN
50075:1993.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the wiring
rules, shall be provided with a plug in accordance
with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
3.2.1.1 In the United Kingdom, apparatus which is fitted P
with a flexible cable or cord and is designed to be
connected to a mains socket conforming to BS
1363 by means of that flexible cable or cord and
plug, shall be fitted with a ‘standard plug’ in
accordance with Statutory Instrument 1768:1994 -
The Plugs and Sockets etc. (Safety) Regulations
1994, unless exempted by those regulations.
NOTE ‘Standard plug’ is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS
1363 or an approved conversion plug.
Page 16 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
3.2.1.1 In Ireland, apparatus which is fitted with a flexible N/A
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 - National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
3.2.4 In Switzerland, for requirements see 3.2.1.1 of N/A
this annex.
3.2.5.1 In the United Kingdom, a power supply cord with N/A
conductor of 1,25 mm2 is allowed for equipment
with a rated current over 10 A and up to and
including 13 A.
3.3.4 In the United Kingdom, the range of conductor N/A
sizes of flexible cords to be accepted by terminals
for equipment with a RATED CURRENT of over
10 A up to and including 13 A is:
2 2
• 1,25 mm to 1,5 mm nominal cross-sectional
area.
4.3.6 In the United Kingdom, the torque test is P
performed using a socket outlet complying with
BS 1363 part 1:1995, including Amendment
1:1997 and Amendment 2:2003 and the plug part
of DIRECT PLUG-IN EQUIPMENT shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.13, 12.16 and 12.17,
except that the test of 12.17 is performed at not
less than 125 °C. Where the metal earth pin is
replaced by an Insulated Shutter Opening Device
(ISOD), the requirements of clauses 22.2 and 23
also apply.
4.3.6 In Ireland, DIRECT PLUG-IN EQUIPMENT is N/A
known as plug similar devices. Such devices shall
comply with Statutory Instrument 526:1997 -
National Standards Authority of Ireland (Section
28) (Electrical plugs, plug similar devices and
sockets for domestic use) Regulations, 1997.
Page 17 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
5.1.7.1 In Finland, Norway and Sweden TOUCH N/A
CURRENT measurement results exceeding 3,5
mA r.m.s. are permitted only for the following
equipment:
• STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential
bonding has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the
installation of that conductor by a SERVICE
PERSON;
• STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
6.1.2.1 In Finland, Norway and Sweden, add the N/A
(A1:2010) following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of
which shall pass the electric strength test below,
or
- one layer having a distance through
insulation of at least 0,4 mm, which shall pass the
electric strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
- is subject to ROUTINE TESTING for
electric strength during manufacturing, using a
test voltage of 1,5 kV.
Page 18 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
It is permitted to bridge this insulation with an N/A
optocoupler complying with 2.10.5.4 b).

It is permitted to bridge this insulation with a


capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to
EN 60384-14:2005, may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 60384-14, which in addition to the Y3 testing,
is tested with an impulse test of 2,5 kV defined in
EN 60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on
all the test specimens as described in
EN 60384-14:
- the impulse test of 2,5 kV is to be
performed before the endurance test in
EN 60384-14, in the sequence of tests as
described in EN 60384-14.
6.1.2.2 In Finland, Norway and Sweden, the exclusions N/A
are applicable for PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE
B and equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR and is
provided with instructions for the installation of
that conductor by a SERVICE PERSON.
7.2 In Finland, Norway and Sweden, for N/A
requirements see 6.1.2.1 and 6.1.2.2 of this
annex.
The term TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.
7.3 In Norway and Sweden, for requirements see N/A
(A11:2009) 1.2.13.14 and 1.7.2.1 of this annex.
Page 19 of 19
Report No.: 085-110044304-000
Attachment No. 2
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

Annex ZD
(informative)

IEC and CENELEC code designations for flexible cords


Type of flexible cord Code designations
IEC CENELEC
PVC insulated cords
Flat twin tinsel cord 60227 IEC 41 H03VH-Y
Light polyvinyl chloride sheathed flexible cord 60227 IEC 52 H03VV-F
H03VVH2-F
Ordinary polyvinyl chloride sheathed flexible cord 60277 IEC 53 H05VV-F
H05VVH2-F
Rubber insulated cords
Braided cord 60245 IEC 51 H03RT-F
Ordinary tough rubber sheathed flexible cord 60245 IEC 53 H05RR-F
Ordinary polychloroprene sheathed flexible cord 60245 IEC 57 H05RN-F
Heavy polychloroprene sheathed flexible cord 60245 IEC 66 H07RN-F
Cords having high flexibility
Rubber insulated and sheathed cord 60245 IEC 86 H03RR-H
Rubber insulated, crosslinked PVC sheathed cord 60245 IEC 87 H03RV4-H
Crosslinked PVC insulated and sheathed cord 60245 IEC 88 H03V4V4-H
Page 1 of 2
Report No.: 085-110044304-000
Attachment No. 3
Circuit diagram:

RF1
10ohm 1W
D3

D1
D4

D2
C1
L1

R2

L2
optional

R10

C2
R9

R8
C7
optional

R12

1
R11

C6

R7
U1

R5

R1
5

D6

C4
R4

R3
D5

1
4
3

T1
Tb

Ta

R13
D7

C9
C7
R14
optional

L3
C8

V+
V-

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 2 of 2
Report No.: 085-110044304-000
Attachment No. 3
PCB layout drawing:

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Page 1 of 8
Report Ref. No.: 085-110044304-000

Attachment No. 4
Contains
Cover page 1 page

EU Plug portion test report 3 pages

UK Plug portion test report 4 pages

Total: 8 pages
Page 2 of 8
Report Ref. No.: 085-110044304-000
Attachment No. 4

“EU plug portion test” according to EN50075:1990

Clause Requirement- Test Result- Remark Verdict


7 DIMENSIONS P
Dimension of plug shall comply with standard sheet1 (See appended table) P
8 PROTECTION AGAINST ELECTRIC SHOCK --
8.1 Live parts of the plugs, with the exception of the bare P
metal pins, should not be accessible(75N, 60 second
in 35°C ambient)
8.2 It should not be possible to make connection between P
a pin of a plug and live socket contact of a socket
while the other pin is accessible
8.3 External parts of plug made of insulating material P
9 CONSTRUCTION --
9.1 Plugs are not rewirable P
9.2 Switches, fuse, lampholder shall not be incorporated P
in plugs
9.3 Pins of shall have adequate mechanical strength to P
withstand the stress imposed during use
9.4 Pins of plugs shall be locked against rotation and P
adequately fixed into body of the plug
9.6 Plug shall be shaped in such a way and made of such P
material that they can easily be withdrawn by hand
from the socket outlet
10 RESISTANCE TO HUMIDITY P
11 INSULATION RESISTANCE AND ELECTRIC STRENGTH P
11.1 Insulation resistance (500V, min 5MΩ) 200MΩ P
11.2 Electric strength (2000V) P
13 MECHANICAL STRENGTH --
13.1 Compression test (150 N, 5 min) P
13.2 Tumbling barrel test for adaptor P
After test, the pin shall not turn when a torque of 0.4
Nm is applied, first in one direction for 1 min and then
in the opposite direction for 1 min.
13.3 Abrasion test on the insulating sleeves 20000 movements: no damage P
13.4 Pin shall not have displaced in body of the plug more P
than 1mm
14 RESISTANCE TO HEAT AND TO AGING P
14.1 Sufficient resistant to heat Incorparated with adaptor. P
14.1.1 After 1 h in heating cabinet at 100°C no damage Tested with adaptor. P
shown

TÜV SÜD Certification and Testing (China) Co. Guangzhou Branch


Page 3 of 8
Report Ref. No.: 085-110044304-000
Attachment No. 4

Clause Requirement- Test Result- Remark Verdict


14.1.2 After 1 h in heating cabinet at 80°C and a force of P
20N through the jaws no damage shown
14.2 Aging test P
-at 70°C for 168h P
-at room temperature for 96h P
No traces of cloth at a force of 5N P
No damage leads to non-compliance P
15 CURRENT-CARRYING PARTS AND CONNECTIONS --
15.1 Connections withstand the mechanical stresses P
occurring in normal use
15.2 Electric connection shall be so designed that contact P
pressure is not transmitted through insulation
15.3 Current-carrying parts P
Copper P
Alloy containing at least 58% of copper equivalent 59%-63% copper P
16 CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION P
Live parts of different polarity: 3mm 13.9 mm P
Through insulation between live parts and accessible 2.1 mm P
surfaces: 1.5mm
17 RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT --
AND TO FIRE
Glow-wire test P
Parts of insulating material to retain current-carrying P
parts: 750 °C
Other parts: 650 °C P

7 Table: Dimension of plug


st nd rd
Location 1 Sample 2 Sample 3 sample Limit (mm)
1
A 26.30 26.40 26.40 26.1 ± 0.5*
1
B 14.10 14.10 14.10 13.7 ± 0.7*
C 35.60 35.70 35.70 35.3 ± 0.7*1
(see note *1) 18.10 18.10 18.10 ≥18
D 19.20 19.10 19.20 19 ± 0.5
E 3.98 3.98 3.99 Ø4.0 ± 0.06
F 3.50 3.60 3.60 Ø3.8 Max.
3
F 3.89 3.86 3.89 Ø4.0 Max.*
3
F 3.83 3.82 3.83 4.0 Max.*
G 10.29 10.33 10.27 10-11
2
a1 18.30 18.40 18.30 18-19.2*
2
a2 17.20 17.30 17.20 17-18*
H N/A N/A N/A 4 Min.
I 5.10 5.00 5.00 R5-R6

TÜV SÜD Certification and Testing (China) Co. Guangzhou Branch


Page 4 of 8
Report Ref. No.: 085-110044304-000
Attachment No. 4

J 45.0º 44.5º 44.6º ---


Alternative for end of pins
K N/A N/A N/A Ø0.7- Ø1.7
L N/A N/A N/A 90° Max.
M N/A N/A N/A 2 Max.
Note
*1: These dimension shall not exceeded within a distance of 18mm from the engagement face of plug.
*2: a1: in the plane of the engagement face, a2: at the ends of pins.
*3: This dimension maybe increased to 4mm within a distance of 4mm from engagement face of plug.

Remark: see standard sheet 1 for details of location of measurement.

TÜV SÜD Certification and Testing (China) Co. Guangzhou Branch


Page 5 of 8
Report Ref. No.: 085-110044304-000
Attachment No. 4

PRODUCT INCORPORATING PINS FOR INSERTION INTO UK SOCKET OUTLET


TEST ACCORDING TO APPLICABLE REQUIREMENTS FROM BS1363-3 AND
ASTA BEAB REQUIREMENT 4 (ABR4)

BS 1363-3:1995 + Amd. No. 9543, 14225, 14540, 17437 & A4

Clause Requirement – Test Result – Remarks Verdict


12.1 Disposition of pins Pass
12.2 Dimensions (See appended table) Pass

12.2.1 Gauging test according to finger 5,the plug portion


shall enter the gauge fully with a force less than Applied force: 2N Pass
10N
In the case of adaptors with ISODs, the test given in
13.8 of BS 1363-2:1995 shall be applied and the
Applied force: 19N Pass
maximum withdrawal force from a socket-outlet
conforming to BS 1363-2 shall not exceed 36N
12.3 Distance of pins from periphery Measured distance: 9.55mm Pass
12.7 Fixing of cover Pass
Deformation immediately following the temperature
12.9 rise test specified in the appropriate (base) standard Pass

12.11 Construction of pins Pass

12.11.1 All exposed surfaces of the adaptor plug pins shall


be smooth and free from burrs or sharp edges and Pass
other irregularities.

12.11.4.1 For solid pins, applying a force 1100N on the pin


Pass
according to figure 32.

12.11.4.2 For non-solid pins, conformity shall be checked by


the following test.
1) Applying a force 800N on the pin according to
Figure 32. 50 times without impact. Pass

2) Separate specimens applying a force 1100N on


the pin according to Figure 32.

12.11.4.3 For ISOD, applying a force 400N on the pin


Pass
according to figure 32.

12.11.5.1 Adaptors with non-solid pins shall not cause


excessive wear to socket contacts or shutters of Pass
sockets-outlets

TÜV SÜD Certification and Testing (China) Co. Guangzhou Branch


Page 6 of 8
Report Ref. No.: 085-110044304-000
Attachment No. 4

BS 1363-3:1995 + Amd. No. 9543, 14225, 14540, 17437 & A4

Clause Requirement – Test Result – Remarks Verdict


Adaptors with ISOD shall not cause excessive
12.11.5.2
wear to socket contacts or shutters of sockets-
outlets. Pass
One type of socket-outlet shall preferably have a
shutter-operating ramp of metal.
12.11.6.1 1 Nm torque test on the opposite two directions
Pass
according to figure 33

12.13 Retention of pins Pass


12.14 Flexibility of pins Pass
12.18 Insulating sleeves on pins Pass
12.19.3 Abrasion resistance of insulating sleeve Pass

13.10 The total mass of the equipment with all specified


connectors shall not exceed 800g. The torque Measured torque: 0.05Nm Pass
exerted on socket shall not exceed 0.7 Nm

BS 1363-1:1995 + Amd. No. 9541, 14539, 17435 & A4


Additional requirements For plug portion with
Insulated Shutter Opening Device (ISOD)
Clause Requirement – Test Result – Remarks Verdict

12.9.1 All exposed surfaces of plug pins shall be smooth


and free from burrs or sharp edges and other
irregularities which could cause damage or Pass
excessive wear to corresponding socket contacts
or shutters

Additional test for adaptor with UK plug need to comply with IEC60950-1
(CB bulletin, IEC60950-1:2005+A1:2009, clause 4.3.6)

Clause Requirement – Test Result – Remarks Verdict

12.17.4 Placed in a heating cabinet at 125(-8, 0)°C for a


period of 120(-5, 0)min, after which the specimen is
removed and immediately cooled by immersion in
water at approximately room temperature.
Pass
The thickness of the insulation remaining at the
point of impression is measured and shall not have
been reduced by more than 50 %.

22.2 75C ball pressure test to ISOD. Pass


23 750C GWT to ISOD. Pass

TÜV SÜD Certification and Testing (China) Co. Guangzhou Branch


Page 7 of 8
Report Ref. No.: 085-110044304-000
Attachment No. 4

Clause 12.2: Dimensions measurement


Dimensions(mm) Sample A Sample B Sample C Limit
A 23.81 23.81 23.82 25.37 max
B 32.85 32.85 32.84 34.6 max
C N/A N/A N/A 15 min.
D 9.55 9.55 9.55 9.5 min.
E (L-E) 11.09 11.08 11.05 11.05-11.18
E (N-E) 11.08 11.06 11.07 11.05-11.18
F (L-E) 22.14 22.15 22.16 22.10-22.36
F (N-E) 22.13 22.13 22.12 22.10-22.36
G1 6.46 6.40 6.38 6.22-6.48
G2 6.44 6.37 6.41 6.22-6.48
H 4.05 4.05 4.05 3.90-4.05
I 22.38 22.37 22.43 22.23-23.23
J 1.41 1.40 1.42 1.35-1.85
K(earth) N/A N/A N/A 7.80-8.05
K (ISOD) 7.99 7.98 8.01 7.75-8.05
L (line) 8.72 9.01 9.17 9.5 max
L (neutral) 8.82 9.01 9.17 9.5 max
M (line) 9.10 8.82 8.81 9.2 max
M (neutral) 8.96 8.76 8.76 9.2 max
N (line) 4.04 4.04 4.03 3.90-4.05
N (neutral) 4.00 4.00 4.02 3.90-4.05
O (line) 17.82 17.83 17.98 17.20-18.20
O (neutral) 17.78 17.77 17.93 17.20-18.20
P (line) 1.77 1.78 1.78 1.35-1.85
P (neutral) 1.78 1.76 1.79 1.35-1.85
Q 7.02 7.02 7.01 6.35 min.
R (line) 1.93 1.81 1.88 1.2-2.0
R (neutral) 1.88 1.86 1.87 1.2-2.0
R (earth) 2.00 2.00 2.00 1.2-2.0
W 0.27 0.27 0.30 R 0.1-1.0
θ1 58.0 58.0 58.0 58º-62º
θ 2 (line) 69.5 68.6 68.3 60º-80º
θ 2 (neutral) 70.0 69.3 69.0 60º-80º
θ 2 (earth) 68.2 67.0 65.7 60º-80º
X1 (for ISOD only) 0.08 0.06 0.09 0.15 max
X2 (for ISOD only) 0.07 0.08 0.10 0.15 max
Alternative chamfers on L and N pin
S (line) N/A N/A N/A 1.35-1.85
S (neutral) N/A N/A N/A 1.35-1.85
θ 3 (line) N/A N/A N/A 58º-62º
θ 3 (neutral) N/A N/A N/A 58º-62º
θ 4 (line) 62.0 62.0 62.0 58º-62º
θ 4 (neutral) 62.0 62.0 62.0 58º-62º
T (line) 1.48 1.48 1.48 1.35-1.85
T(neutral) 1.48 1.48 1.48 1.35-1.85
TÜV SÜD Certification and Testing (China) Co. Guangzhou Branch
Page 8 of 8
Report Ref. No.: 085-110044304-000
Attachment No. 4

U (line) N/A N/A N/A 0.2 Max.


U(neutral) N/A N/A N/A 0.2 Max.
V (line) N/A N/A N/A 1.35-1.85
V(neutral) N/A N/A N/A 1.35-1.85

TÜV SÜD Certification and Testing (China) Co. Guangzhou Branch


Attachment No. 5

Page 1 of 3
Report No.: 085-110044304-000

Model No.: SCFxxxyyyyz1mn (xxx=036-120; yyyy=0005-0100; z=A, C, E, G, I, K, M, O; m=B, W, G, L;


n=A-Z or 0-9)
1. xxx = 036-120 denotes rated output voltage from 3.6-12.0VDC with step 0.1V;
2. yyyy = 0005-0100 denotes rated output current from 50-1000mA with step 10mA;
3. z = A, C, E, G, I, K, M, O, denotes different plug type:
a. z= A, for United States plug, Japan plug or Taiwan plug,
b. z= C, for China plug,
c. z= E, for Europe plug,
d. z= G, for United Kingdom plug, Hongkong plug or Singapore plug,
e. z= I, for Australia plug,
f. z= K, for Korean plug,
g. z= M, for Argentina plug,
h. z= O, India plug.
4. m = B, W, G, L, indicates the color of enclosure;
5. n = A-Z or 0-9, indicates the customer code.
Rated output Rated output
Model Number
Voltage (Vd.c.) Current (mA)
SCF036yyyyz1mn 3.6 50-1000
SCF037yyyyz1mn 3.7 50-1000
SCF038yyyyz1mn 3.8 50-1000
SCF039yyyyz1mn 3.9 50-1000
SCF040yyyyz1mn 4.0 50-1000
SCF041yyyyz1mn 4.1 50-1000
SCF042yyyyz1mn 4.2 50-1000
SCF043yyyyz1mn 4.3 50-1000
SCF044yyyyz1mn 4.4 50-1000
SCF045yyyyz1mn 4.5 50-1000
SCF046yyyyz1mn 4.6 50-1000
SCF047yyyyz1mn 4.7 50-1000
SCF048yyyyz1mn 4.8 50-1000
SCF049yyyyz1mn 4.9 50-1000
SCF050yyyyz1mn 5.0 50-1000
SCF051yyyyz1mn 5.1 50-980
SCF052yyyyz1mn 5.2 50-960
SCF053yyyyz1mn 5.3 50-940
SCF054yyyyz1mn 5.4 50-930
SCF055yyyyz1mn 5.5 50-910
SCF056yyyyz1mn 5.6 50-890

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Attachment No. 5

Page 2 of 3
Report No.: 085-110044304-000

SCF057yyyyz1mn 5.7 50-880


SCF058yyyyz1mn 5.8 50-860
SCF059yyyyz1mn 5.9 50-850
SCF060yyyyz1mn 6.0 50-830
SCF061yyyyz1mn 6.1 50-820
SCF062yyyyz1mn 6.2 50-810
SCF063yyyyz1mn 6.3 50-790
SCF064yyyyz1mn 6.4 50-780
SCF065yyyyz1mn 6.5 50-770
SCF066yyyyz1mn 6.6 50-760
SCF067yyyyz1mn 6.7 50-750
SCF068yyyyz1mn 6.8 50-740
SCF069yyyyz1mn 6.9 50-730
SCF070yyyyz1mn 7.0 50-710
SCF071yyyyz1mn 7.1 50-700
SCF072yyyyz1mn 7.2 50-690
SCF073yyyyz1mn 7.3 50-690
SCF074yyyyz1mn 7.4 50-680
SCF075yyyyz1mn 7.5 50-670
SCF076yyyyz1mn 7.6 50-660
SCF077yyyyz1mn 7.7 50-650
SCF078yyyyz1mn 7.8 50-640
SCF079yyyyz1mn 7.9 50-630
SCF080yyyyz1mn 8.0 50-630
SCF081yyyyz1mn 8.1 50-620
SCF082yyyyz1mn 8.2 50-610
SCF083yyyyz1mn 8.3 50-600
SCF084yyyyz1mn 8.4 50-600
SCF085yyyyz1mn 8.5 50-590
SCF086yyyyz1mn 8.6 50-580
SCF087yyyyz1mn 8.7 50-580
SCF088yyyyz1mn 8.8 50-570
SCF089yyyyz1mn 8.9 50-560
SCF090yyyyz1mn 9.0 50-560
SCF091yyyyz1mn 9.1 50-550
SCF092yyyyz1mn 9.2 50-540
SCF093yyyyz1mn 9.3 50-540
SCF094yyyyz1mn 9.4 50-530
SCF095yyyyz1mn 9.5 50-530
SCF096yyyyz1mn 9.6 50-520

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Attachment No. 5

Page 3 of 3
Report No.: 085-110044304-000

SCF097yyyyz1mn 9.7 50-520


SCF098yyyyz1mn 9.8 50-510
SCF099yyyyz1mn 9.9 50-500
SCF100yyyyz1mn 10.0 50-500
SCF101yyyyz1mn 10.1 50-495
SCF102yyyyz1mn 10.2 50-490
SCF103yyyyz1mn 10.3 50-490
SCF104yyyyz1mn 10.4 50-480
SCF105yyyyz1mn 10.5 50-480
SCF106yyyyz1mn 10.6 50-470
SCF107yyyyz1mn 10.7 50-470
SCF108yyyyz1mn 10.8 50-460
SCF109yyyyz1mn 10.9 50-460
SCF110yyyyz1mn 11.0 50-450
SCF111yyyyz1mn 11.1 50-450
SCF112yyyyz1mn 11.2 50-450
SCF113yyyyz1mn 11.3 50-440
SCF114yyyyz1mn 11.4 50-440
SCF115yyyyz1mn 11.5 50-430
SCF116yyyyz1mn 11.6 50-430
SCF117yyyyz1mn 11.7 50-430
SCF118yyyyz1mn 11.8 50-420
SCF119yyyyz1mn 11.9 50-420
SCF120yyyyz1mn 12.0 50-420

-End-

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 1 of 11 Report No.: 085-110044304-000
Attachment No. 6
Details of:
General view for models SCFxxxyyyyE1mn

Details of: General view for models SCFxxxyyyyE1mn

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 2 of 11 Report No.: 085-110044304-000
Attachment No. 6
Details of: General view for models SCFxxxyyyyE1mn

Details of: General view for models SCFxxxyyyyE1mn

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 3 of 11 Report No.: 085-110044304-000
Attachment No. 6

Details of: Internal construction for models SCFxxxyyyyE1mn

Details of: Components on PCB

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 4 of 11 Report No.: 085-110044304-000
Attachment No. 6

Details of: Components on PCB (Add glue to additionally fix the output wires with PCB)

Details of: Components on PCB

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 5 of 11 Report No.: 085-110044304-000
Attachment No. 6

Details of: General view for models SCFxxxyyyyG1mn

Details of: General view for models SCFxxxyyyyG1mn

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 6 of 11 Report No.: 085-110044304-000
Attachment No. 6

Details of: General view for models SCFxxxyyyyG1mn

Details of: Internal construction for models SCFxxxyyyyG1mn(after remove the top enclosure)

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 7 of 11 Report No.: 085-110044304-000
Attachment No. 6

Details of: Enclosure inside for models SCFxxxyyyyG1mn

Details of: General view for models SCFxxxyyyyA1mn

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 8 of 11 Report No.: 085-110044304-000
Attachment No. 6

Details of: General view for models SCFxxxyyyyA1mn

Details of: T1 general view

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 9 of 11 Report No.: 085-110044304-000
Attachment No. 6

Details of: T1 general view

Details of: T1 general view

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 10 of 11 Report No.: 085-110044304-000
Attachment No. 6

Details of: T1 general view after detach the plastic material (for support transformer secondary pins)

Details of: N3 and N1 winding use magnet wire

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
Photo documentation Page 11 of 11 Report No.: 085-110044304-000
Attachment No. 6

Details of: N2 winding use triple insulation wire

---END---