Laboratory No.

9 Electronic Starters
Name of the members: Nogales Núñez Nicol.
College: Universidad Católica Boliviana “San Pablo”
Teacher's name: Ing. Fernando Vargas Fernandez
Code and name of the discipline: IND-203 (Automated Processes)
Department of Mechatronic and Industrial Engineering
Date of realization: 24/04/2020
- Describe the operation of the soft start circuit and its application.
Lets the three-
phase current go
The soft starters control the effective input voltage to the motor from zero (or Three-phase
if it’s closed and
a configurable value) to the nominal operating voltage for starting and vice 2 thermomagneti
it closes itself if
versa for stopping. By regulating the supply voltage, we control the starting c relay
there is a short
current consumed by the motor and the torque generated.
circuit. 10A  
Opens or shorts
Key selector the current flow
3
switch depending of its
1. Operating voltage (three-phase position. 10A  
mains voltage)
It is a device that
2. Supply voltage of the control
allows to control Siemens
circuit
4 Soft start the start and stop Sirius, 17.6 A
3. Start input IN
of induction - 7.5KW
4. Output ON
motors.
5. Status LED DEVICE
6. Status LED STATE/ BYPASSED / Three-phase,
5 Motor drive
FAILURE 0.25HP/380VCA  
7. Start ramp time
8. Start voltage - Describe the start-up operation of a motor with a frequency inverter,
9. Motor connection terminals default parameters. And you mention some applications

It is a system for controlling the rotational speed of an alternating current


(AC) motor by controlling the supply frequency supplied to the motor. A
variable frequency drive is a special case of a variable speed drive.
For the operation of the circuit:
1. It is started with the selector key. 1. Display
2. The starter starts with the thyristors. 2. Board for
3. After a programmed time, the electric motor will commute normally, parameterization
remaining to work in this way. (STATE/BYPASSED) 3. Control part: 5 digital
That is, I switch from electronic start (thyristors) to electric start (platinums). inputs, 1 relay output, 1
To verify starting current to save energy and protect the motor, it is important analog input, 1 positive
to remember that the motors start abruptly, producing a water hammer that temperature coefficient input
can injure the motors themselves, and therefore soft starters avoid this. 4. Final part: 220 VAC three-
As measured, the current gradually increases from 0.32 A to 0.41 A and the phase power terminals.
voltages start at 236 VCA and start at 392 VCA. 5. Start button
Possible applications for Siemens Sirius 3RW40 soft starters: 6. Stop button
(1) Hydraulic bombs 7. Investment reversal
(2) Presses 8. Potentiometer
(3) Elevators 9. DSI-RS485 port
(4) Lifts
For the operation of the
- Insert the corresponding circuit circuit:

1. Turn on the thermomagnetic circuit breakers (three-phase and single-


phase).
2. Select the working frequency with the potentiometer (in this case at
maximum frequency).
3. Press the start button to start the engine.
4. When a turn reversal is made, the button is pressed and the motor
automatically stops for a moment and rotates the direction of movement.
The acceleration start time is 10 seconds at a certain frequency of 60 Hz,
with the potentiometer we can regulate the frequency.
As a curious fact we can add that in Bolivia it works with a frequency of 50
Hz.
Possible applications for frequency inverter:
(1) Conveyor belts
(2) Centrifugal pumps and fans
(3) Positive displacement pumps
(4) Lifts and elevators
(5) Extruders:
(6) Mechanical presses and rocker arms
(7) Textile machines
- Technically describe all the devices used in the circuit (8) Air compressors
(9) Extraction pumps
No. Devices Characteristics Observations - Insert the corresponding circuit
Lets the biphasic
current go if it’s
Single-phasic closed and it
1 thermomagneti closes itself if
c relay there is a short
circuit. 220VCA/
10A  
- Technically describe all the devices used in the circuit

No. Devices Characteristics Observations


Lets the biphasic
current go if it’s
Single-phasic
closed and it closes
1 thermomagneti
itself if there is a
c relay
short circuit.
220VCA/ 10A  

Lets the three-phase


Three-phase current go if it’s
2 thermomagneti closed and it closes
c relay itself if there is a
short circuit. 10A
 
Electrical protection
element that protects
against short circuits
3 Motor guard
and overcurrents at
the same time 1.6A-
32A  
A frequency variator
allows, among other
Frequency options, to regulate Powerflex
4
inverter the motor speed at 4M/1HP/220VCA
any time, not only at
start and stop.
Three-phase,
5 Motor drive
0.5HP/380VCA  

- Final conclusion of the entire laboratory

We can define that whatever the electronic starter (soft starter or frequency
variator), both have one thing in common, they can manage to control the
electric current injected into the motors and thus generate various parameters
of behavior and behavior for the different applications of industrial electrical
machines.