Research and Design of A Multifunctional Soft Starter
Research and Design of A Multifunctional Soft Starter
Research and Design of A Multifunctional Soft Starter
Abstract: Aiming at the starting problem of motor equipment, this paper studied a large of existing soft start modes and their starting
characteristics. Then, using MATLAB/Simulink tool to build common soft start simulation models, this paper got a lot of simulation
waveforms. These helped to identify the applicable occasions of these soft starters and their respective advantages and disadvantages.
We designed an integrated soft starter that includes voltage ramp soft start, current limit soft start, voltage jump soft start, and discrete
frequency soft start based on dsPIC6014a in the premise of doing these efforts, and given the system's hardware and software design in
detail. The test results on the experimental platform showed that this design can easily set the start modes according to different starting
requirements and all the modes possess so prefect control effect that motor can start smoothly, and experimental data indicators also meet
operation requirements. So it is worthy of promotion and application.
Key Words: SCRSoft startDiscrete frequencydsPIC
(c)Torque waveform
Fig 3 current-limiting starting the simulation waveform
(c)Torque waveform
(a)The current waveform
Fig 4 voltage kick start the simulation waveform
1070
Discrete variable frequency soft starter and ordinary ability to recognize and prevent of CPU to pulse CPU
electronic soft starter basically have the same structure, interrupt by mistake.
but the former can maintain a higher starting torque,
effectively reduce starting current and meet the general
load and full load starting requirements.
The so-called discrete frequency is the frequency
control, the AC input some half wave conduction, some
half wave cutoff, thereby increasing cycle of output Fig.6 voltage synchronous detection circuit
voltage to reduce the frequency. Due to the cycle of B. The power factor detection circuit
change are multiples, so frequency is an integer Induction motor for thyristor voltage regulation circuit,
multiple.Discrete variable frequency soft starter start-up belongs to the perceptual load and when on both ends of
process is in the band of the switching process, so the thyristor voltage drop to zero, the current is not zero,
which will inevitably lead to stream Angle of (namely
classification variable frequency, also known as discrete
variable frequency. The starting simulation waveform is the power factor Angle) existed.And voltage of the
shown in Figure 5 (starting from 3.85Hz, 7.14Hz,
motor is not a single determined by triggering Angle ,
12.5Hz, 16.7Hz, 25Hz, AC voltage regulator starting,
starting with 50Hz). also influenced by stream Angle .While in the process
of starting, stream Angle changed larger along with
4 DESIGN OF HARDWARE the rotating speed, to accurately control the voltage of
the machine, you must make the thyristor trigger Angle
Prototype design block diagram as shown in figure 5, followed the stream Angle changes, thus to eliminate
the controller used for Microchip company the asynchronous motor in no load or light load startup
dsPIC6014A - 301 16-bit high-performance electromagnetic torque and current oscillation.It
controller/PF, main circuit is the same as the traditional presents a motor soft start based on gradient method of
soft starter.Controlling circuit mainly includes: power factor Angle closed-loop control strategy as in
Synchronous voltage detection circuit, voltage/current [5], this method is effective to improve the soft starting
detection circuit, drive circuit, the forerunner of the of the motor performance.In order to achieve this
security circuit , contactor control circuit and buttons algorithm, the phase current and phase voltage can be
and display. detected by phase difference to obtain the Angle of
thyristor stream.Current signal of the zero crossing
detection circuit as shown in figure 7, current signal go
through filter circuit and signal conversion to obtain
current synchronization signal.Joint voltage synchronous
detection circuit is shown in figure 7, through the software
to calculate the motor power factor Angle, to adjust the
thyristor trigger Angle compensation.
1071
under-voltage
g pprotection function. button, and motor starting initialized, everything in
place, the processor calculates ,and adjust b according
to the feedback,until the thyristor conduct and bypass
contactor closed completely. At this point, the detection
circuit continue to work, real-time to monitor the
running state of the system, realize the protection
function to motor after the start.
Fig. 8 current/voltage signal detection
D. Driver circuit(e.g[7],[8])
Front drive circuit integrated darlington chip
(ULN2003AN) will amplify I/O output signal , with
enough power signal pulse transformer to isolate it, then
the thyristor is driven. Triode Q1 run in switch state in
order to make/trigger pulse is prohibited.Found in the
actual test, the trigger pulse width should not be too
wide, otherwise easy to cause Q1 damaged, thus
triggering pulse use enough power narrow pulse
sequence, at the same time, he reliability of the trigger is
guaranteed ,and the pulse transformer saturation is
prevented.Driver circuit is shown in figure 9.
Fig 10 The main program flow chart
6 EXPERIMENT RESULTS
a three-phase induction motor with the fan load soft
start experiment is taken ,and the parameters of the
motor is =380/660V,= 11A,= 5.5KW,= 900r/min.Using
human-machine interface can choose starting mode and
set up specific parameters, measured the experimental
waveforms of different starting mode as shown in figure
Fig.9 drive circuit design 11.
E. Parameter setting, display and protection function
The soft starter contains buttons, display screen.Button
complete motor start-stop control mainly, display for
the touch screen, the user can choose starting mode and
set the relevant parameters according to the actual
load.When start button press, the motor set triggering
Angle according to the requirements calculation,
control thyristor on and off.From the starting to stable (a)Double oblique wave voltage starting
operation of motor, the system independently complete
the whole process.At the same time, the soft start
equipment for over current, overload, overheating and
lack of equal protection.
1072
[4] Ge GuangJun, Wang Xi, Ma Xuke. Design of a new type of
soft starter of three-phase asynchronous motor. Industry and
mine automation, 2009 (3): 17-20.
[5] Tong Jun, Zhang Zhen, Guo Changyong. Research on
closed loop control technology of soft start power factor
angle of motor [J]. proceedings of the, 2013, 17 (12): 51-56.
[6] Cheng Xue, Hou Sizu, Wang Bin. Design and
implementation of a soft starter for an induction motor with
(d)Hierarchical variable frequency soft start limited current [J]. motor technology, 2006 (4): 8-10+13
Fig 11 experimental waveforms [7] Zhang Hao, Zhong Chao Wei. Software of electronic soft
starter control algorithm design. Power electronics
In order to see the characteristics of the soft start mode technology, 2002, 1 (1): 30-32+53.
from the experimental waveforms directly, the starting [8] Chen Zhonghua, Guo Fengyi, Shi Zhaoyuan. Research and
data are listed in Table1. Simulation of soft start control method of asynchronous
Table1 Experimental Data of Soft Start motor [J]. automation of mining and mining, 2008 (1): 4-7
Startin Ramp Current-li Voltage Discrete
g
voltage miting kick start frequenc
Mode start start y Soft
start
dada
Ist ! 6I N ! 5I N ! 5I N ! 3I N
t∀4 IN 5s 8s 3s 0s
7 CONCLUSION
Now there are many electronic soft starting device on
the market,the product features are different , so,it is
important to choose a easy to use and full-featured one
for the user.This design has a broad application
prospects because it offers more soft start mode,
flexible parameter adjustment, strong ability to adapt to
the load, and support the change of the online analog
current and voltage.
8 REFERENCES
[1] Wang Yi, Xu Dianguo, Zhao Kaiqi. A new method to
improve the starting torque of the induction motor with
thyristor control [J]. proceedings of the electrical
engineering, 2004, 24 (3): 145-150.
[2] Wang Zhaoan, Liu Jinjun. Electric power and electronic
technology [M]. Beijing: Mechanical Industry Press, 2009
154-156.
[3] Ruan Yi, Chen Boshi. Electric drive automatic control
system [M]. Beijing: Mechanical Industry Press, 118-120.
2009
1073