Array Sizing: Information About System
Array Sizing: Information About System
Array Sizing: Information About System
3. Module
8400000∗1.3
DC Daily load demand∈Ah= =118181.8 Ah
0.77∗120
1∗8400000
Battery cpacity ( Ah ) = =65359.5 Ah
120∗0.7∗0.85∗1.8
65359.5
NO of batt ∈¿= =71.82 round up 72
910
120
NO of batt inseries= =20
6
Total NO of batt=72∗20=1440
3∗8400000
Battery cpacity ( Ah ) = =196078.43 Ah
120∗0.7∗0.85∗1.8
196078.43
NO of batt ∈¿= =215.47 round up 216
910
120
NO of batt inseries= =20
6
Total NO of batt=216∗20=4320
Inverter sizing
Inverter rating =𝐿𝑜𝑎𝑑×1.25(𝑠𝑎𝑓𝑒𝑡𝑦 𝑓𝑎𝑐𝑡𝑜𝑟)
¿ ≫11572 ( Total module )∗300 ( Module ℘ )∗300 ( suny days )∗5.48 ( PSH )
¿ ≫5707310400 Wh=5707310.4 KWhTotal energy generation energy by PV system
1 KWh energy price by Diesel generator=45 Afg/KWh
So 5707310.4*45=256828968 Afg will be saved yearly by this system
And 1 KWh generated by diesel generator produce 1.5 Kg CO2
So 1.5 *5707310.4=8560965.6 Kg CO2 emission prevent by this system