Power Electronics Lab Lab 3

IMPLEMNTATION OF AC STATIC CONVERTER WITH RESISTIVE & RESISTIVE-


INDUCTIVE LOADS

Objectives

To carry out the experiments “AC Static converter with ohmic load (R)”.

To carry out the experiments “AC Static converter circuit with ohmic - inductive load (RL)”.

List of Equipment/Software

Following software/equipment is required:

 Supply voltage: 45 V
 Ohmic - inductive load: 33 Ω (3 x 100 Ω resistances in parallel)
 Ohmic- inductive load: 33 Ω (3 x 100 Ω resistances in parallel) and 50 mH (1 inductance in
series)
 Pulse form: “Pulse”
 Bridge topology: “735 012 – 11 W1C”
 CASSY Software

Circuit Diagram
Power Electronics Lab Lab 3

Connection Diagram

Experimental Procedure
Power Electronics Lab Lab 3

In Lab Exercise No. 01

The time profiles should be drawn for the angles 90° and 135°and described briefly. To obtain the line
diagrams below, please connect the components as per connection diagram. Open the CASSY Lab file
W1C_R_90.labx.
Measurement of us01, uV1, ud, id
us01: Line voltage
ud : DC voltage
id : DC current
uV : valve voltage

Task 1.1
Measurement of us01, uV1, ud, id at α = 90°

Results/Graphs
Power Electronics Lab Lab 3
Task 1.2
Measurement of us01, uV1, ud, id at 135°
Open the CASSY Lab file W1C_R_135.labx.

Results/Graphs
Power Electronics Lab Lab 3

In Lab Exercise No. 02

Transfer characteristic of AC Static converter circuit with ohmic load

Measure how the root-mean-square value I α is dependent on the control angle in the range from 0° …
150°. The measurements should be taken in 30° steps. Calculate the quotients of the current and draw the
control characteristic of the DC current f(α) = Id(α) / Id(α=0).

Id(α) : DC current (averaged value) depending on angle.

Evaluated Results

α/° 0 30° 60° 90° 120° 150°


°
Id(α)/V
Id(α) / Id(α=0)
Power Electronics Lab Lab 3

In Lab Exercise No. 03

Compare the controls characteristics determined for the ideal case (Theory) and for the measured values
as drawn in the fig. above.

Theoretical results

Id(α) / Id(α=0) = √ (1/π * (π - α + sin 2α ) / 2)

Id(α) / Id(α=0) ----- ----- ----- ----- ---- ---

Analysis/Discussion

In Lab Exercise No. 04

The time profiles of which have been drawn for the angles 45° and 135° are to be described briefly. To
obtain the line diagrams below, please connect the components as shown in connection diagram. Open the
CASSY lab file W1C_RL_45.labx.
Measurement of us01, ud, uv1, id.
us01 : line voltage
ud : DC voltage
id : DC current
uV1 : Valve voltage
Power Electronics Lab Lab 3

Task 4.1
Measurement of us01, ud, uv1, id.at α = 45°
Result/Graph

Task 4.2
Measurement of us01, ud, uv1, id.at α = 135°

Open the CASSY lab file W1C_RL_135.labx.

Result/Graph
Power Electronics Lab Lab 3

Analysis/Discussion

You might also like