Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Nozzle Performance Study System: Technical Description

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Page 1/2

02/2003

HM 260 NOZZLE PERFORMANCE STUDY SYSTEM


Technical description
The critical pressure ratio and the efficiency of
nozzles can be determined using the experi-
mental set-up HM 260. It is possible to insert
various nozzles or a baffle plate into the force
measurement device. The test chamber is fitted
with two air connections. Different forces can be
determined using the different inserts and air
connections. The distance between nozzle and
baffle plate is adjustable. The nozzle air inlet
pressure is adjusted using a pressure controller.
The back pressure is set with a needle valve at
the mass flow meter. The following data are
measured: airflow rate of air, air temperature,
pressure at inlet and outlet of the nozzle and
force.

Experiments
• Critical pressure ratio (convergent-divergent
pressure ratio)
• Demonstration of choking effect
• Determination of airflow rate
• Nozzle thrust
• Nozzle efficiency
• Determination of flow rate at the narrowest
cross-section of a nozzle

• Nozzle and baffle plate system with variable distance


• Measurement of nozzle thrust or baffle plate force
• Relationship of nozzle pressure, back pressure and critical
pressure ratio
• Demonstration of„choking effect“
• Determination of nozzle efficiency

G.U.N.T. Gerätebau GmbH, P.O.Box 1125, D-22881 Barsbüttel, Phone +49 (40)670854-0, Fax +49 (40)670854-42, E-mail sales@gunt.de, Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/2
02/2003

HM 260 NOZZLE PERFORMANCE STUDY SYSTEM


Specification
[1] Benchtop unit to investigate different nozzles
[2] Determination of critical pressure ratio,
nozzle thrust, baffle plate force, nozzle efficiency,
„choking effect“
[3] Test chamber made of stainless steel, force
measurement via bending beam
[4] 5 different nozzles, (4 convergent-divergent,
1 convergent)
[5] Measurement of pressure and temperature at
nozzle inlet and outlet
[6] Needle valve for setting the back pressure
[7] Airflow directly indicated on flow meter
[8] lxwxh 800x450x830 35kg

Technical data
Required air approx. 240l/min,
Compressed air: max. 10bar
Airflow meter made of conical glass,
measuring range: 0.7...8.3g/s
5 nozzles of different length:
diameter of nozzle cross-section: 2mm
- 1 convergent
- 4 convergent-divergent, 3.6…15.8mm long
Test chamber made of stainless steel
1 nozzle inlet air indicator, 2 nozzle inlet air pressure controller, 3 pressure vessel - test chamber, Force measurement: measuring the bending of a
4 control valve with mass flow meter, 5 nozzle outlet air pressure indicator, 6 nozzle outlet air
temperature indicator, 7 flexion pipe force indicator, 8 nozzle inlet air temperature indicator
flexion beam with a distance sensor

Dimensions and weight


l x w x h : 800 x 450 x 830 x mm
Weight : approx. 35 kg

Connections
100-240V, ~50/60Hz
Compressed air: 240l/min
Scope of delivery
1 benchtop unit HM 260 including 5 different
nozzles
1 instructions manual

Order details
070.26000 HM 260 Nozzle Performance
Study System

G.U.N.T. Gerätebau GmbH, P.O.Box 1125, D-22881 Barsbüttel, Phone +49 (40)670854-0, Fax +49 (40)670854-42, E-mail sales@gunt.de, Web http://www.gunt.de
We reserve the right to modify our products without any notifications.