WDG-1210 現址式氧氣分析儀
WDG-1210 現址式氧氣分析儀
WDG-1210 現址式氧氣分析儀
i 0 to 25 % Oxygen Concentration
THE WDG SERIES IS A HIGHLY FLEXIBLE RANGE OF The unique sensor design allows the entire sensor
+,*+ˎ35(&,6,21)/8(*$62;<*(1$1$/<6(56 assembly, including the heater, to be removed without
'(9(/23('63(&,),&$//<)25&20%867,21 disturbing the outer protection tube which remains in
$1$/<6,6$1'&21752/$33/,&$7,216. the process; this makes field service fast and easy, and
because there is no need to return the probe to the
The WDG 1200 and 1210 are rugged and reliable for net factory for repair, there’s no expensive downtime.
oxygen and use industry-proven zirconium oxide sensor
technology. The outer probe tube is 310 stainless steel,
MODELS
so no abrasion shield is needed for most applications.
The integrated/remote controller features precision MODEL MAXIMUM FLUE READING
temperature control for optimum stability, built-in GAS TEMPERATURE DISPLAY
diagnostics, and over- temperature protection. Modbus
WDG 1200 0 - 677 °C / 32 - 1250 °F INTEGRATED
and 4-20 mA outputs are standard; automatic calibration
is available. WDG 1210 0 - 677 °C / 32 - 1250 °F REMOTE
F E AT U R E S
• POLLUTION CONTROL
: : : $ 0 ( 7 ( . ˎ / $ 1 ' & 2 0 | L A N D. E N Q U I RY @ A M E T E K . CO M
WDG 1200 & 1210
FLUE GAS OXYGEN ANALYSERS
SPECIFICATIONS
Measurement Range: From 0 to 1 %, 0 to 25 % O2 v/v
Accuracy: ±1 % of measured value or ± 0.05 % oxygen, whichever is greater
Response Time: < 3 secs to calibration gas 63 % of a process step change, 20 secs
Drift: < 0.1 % of cell output per month (< 0.005 % O2 per month with 2 % O2 applied)
Linearity: ±1 % of output span
Repeatability: ±1 % of output span
3UREH/HQJWKV 0.22 m (9 in), 0.45 m (18 in), 0.9 m (36 in), 1.8 m (72 in)
Mounting Options: 2” NPT thread, 3” 300 lb ANSI, 2” 150 lb ANSI, 3” 150 lb ANSI, 4” 300 lb ANSI, DN65 PN6 (JIS)
Max Flue Gas Temperature: 677 °C (1250 °F)
6DPSOH3UHVVXUH ±2 psig (± 13.8 kPa)
Environment: Ambient Temp. : -20 to 71 °C (-5 to 160 °F)
Relative Humidity: 10 % to 90 %, non-condensing
Calibration Gas Requirement: Use all calibration gases @ 10 psig, 3 to 6 scfh (0.70 kg/cm2, 1.41 to 2.82 L/min) O2 Span Gas: Air or
from 1.0 % to 25 % O2, balance N2 O2 Zero Gas: 2 % or from 0.1 to 10% O2, balance N2
Calibration: Manual, automatic and remote trigger
352%(&21752/81,7
Display/Keypad: Single-line 4-digit LED; 4 keys
Analog Outputs: Isolated 4-20 mA. Max impedance 500 ohms. Current loop isolation is 1000 V rms
Alarms: System Fault, Maintenance, Calibration in Progress – Single pole form C 2A at 30 V ac/dc
Communications: Modbus, Isolated RS-485 2-wire
Environment: Ambient Temp.: -20 to 71 °C (-5 to 160 °F)
Relative Humidity: 10 % to 80 %, non-condensing
Enclosure: IP65
3RZHU5HTXLUHPHQWV Nominal 115-230 Vac ±10 %, 47-63 Hz; 4 A 6 mm female thread for earth grounding
System Compliance: EMC directive 89/336/EEC Low Voltage Directive 73/23/ EEC, CE
AUTOMATIC CALIBRATION UNIT
Dimensions: 300 x 200 x 155 mm / 11.8” x 7.9” x 6.1” (HxWxD)
:HLJKW 6 kg / 13.2 lbs.
Operating Temperature: 0 to 50 °C / 32 - 122 °F
Enclosure Rating: IP65
3RZHU6XSSO\ Selected to 110 v or 230 v a.c. 50-60 Hz 10VA
Supply Tolerance: -10 %, +20 %
*DV,QOHW3UHVVXUH 25 - 30 psi (1.7 to 2.0 bar)
*DV2XWOHW)ORZ 3 to 6 scfh (1.6 to 2.8 l/min)
3UHVVXUH6ZLWFK 15 psi (1.0 bar) trip pressure
Span (slave) Relays: 2 - galvanically free changeover relay contacts
Control Interface: Single 8 core hard wire lead to Genesis Control Unit
Fuse Rating: 125 mA @ 230v antisurge, 250 mA @ 110v antisurge
,VRODWLRQ6ZLWFK5DWLQJ 240V 1A (customer supplied)
Installation: Category II
Overvoltage: Category II
2)121ˎ&217$&77(03(5$785(
i Measures
Measu
ures CO O2 NO - Calculates CO2 and NOX
i Acid Dewpoint • SO3 • H2 SO4
:::$0(7(.ˎ/$1'&20
CONTACT US
www.ametek-land.com
MARCOM0496 WDG 1200 & 1210 Rev 2 Copyright © 2008-20 LAND Instruments International. Continuous product development may make it necessary to change these details without notice.