Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Drew Testo 350 PDS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MONITORING EQUIPMENT

DREWTM/testo 350
Description
DREW/testo 350 Emission Analyzer is one of the most
advanced portable semi-continuous emission analyzers
providing compliance level accuracy, extremely flexible test-
ing arrangements with versatile configuration and reporting
capabilities. It is designed for every combustion application
from slow-speed two-stroke engines, medium- and high-speed
four-stroke engines, boilers, gas turbines and incinerators
requiring simple or occasional testing to more advanced
exhaust emission compliance monitoring.

Exclusive sensor design, patented sample gas paths, and active


sample conditioning innovations are combined for a light-
weight and simple-to-use emission monitoring solution.

Features
DREW/testo 350 Emission Analyzer’s exclusive sensor design
technology allows for high accuracy emission monitoring. DREW/testo 350 Emission Analyzer (PCN 1AA9771)

• Market leading, six-sensor simultaneous measurement


• New generation low range CO sensor and low range • Long-lasting NiMH rechargeable battery pack with
NOx sensor available (0.1 ppm resolution) for gas turbine outboard DC connection and AC operation
application • Available trigger input option to start and stop measure-
• Wide range CO2 measurement using advanced NDIR ment externally
technology • RS232 computer connection for immediate software
• Quick and easy pre-calibrated plug-and-play sensor analysis
replacement • easyEmission software user interface for advanced analysis
• Revolutionary continuous temperature compensation including graphics functions, diagnostics, on-line measure-
and control extends testing range for assured accuracy ment and reporting capabilities
• Innovative dilution system for the widest CO testing • Simple on-site sensor calibration capability including
range and longest sensor life diagnostic and sensor output
• Automatic fresh air rinse
• Superior sample conditioning for true NOx results Standard Configuration
• Extensive remote control capabilities Sensor Range Resolution
• Comprehensive combustion and environmental O2 0 to 25% vol. 0.1% vol.
calculations NO 0 to 3000 ppm 1 ppm
• Measurement unit options NO2 0 to 500 ppm 0.1 ppm
• Programmable automatic testing programs for short-term SO2 0 to 5000 ppm 1 ppm
tests or long-term monitoring CO (H2 comp.) 0 to 10,000 ppm 1 ppm
• On-board memory to 250,000 measurement readings
CO2 (NDIR) 0 to 50% vol. 0.01% vol.
• Extensive data management including advanced bus system
for multi-unit logging from multiple sampling points
• Handheld control unit operation provides testing
flexibility
• User-definable control unit display settings and frequently
accessed function keys
• Customizable reporting and printing capabilities
• Simple rugged connector for sample gas

Continued on page 2

DREW/testo 350 PDS 0612 R0


Application and Benefits With routine and systematic measurement of exhaust
emissions, operators can help identify degraded conditions
Monitoring exhaust emissions is becoming more prevalent
of combustion machinery. Furthermore, increased activ-
in response to increased regulatory requirements, including
ity in the development of emissions trading would allow
the following:
operators to be ready to go without having the need to
invest in complicated and often expensive equipment and
• MARPOL 73/78 Annex VI: Regulation 13 – Nitrogen
learn how to monitor exhaust emissions and interpret the
oxides (NOx)
measurements.
• MARPOL 73/78 Annex VI: Regulation 14 – Sulphur Complete Solution
oxides (SOx)
DREW/testo 350 Emission Analyzer (PCn 1AA9771) comes
• MARPOL 73/78 Annex VI: Appendix III – Criteria standard with the following:
and procedures for designation of SOx emission control • Analyzer box with O2, NO, NO2, SO2, CO and CO2 (NDIR)
areas (SECA) sensors
• Engine exhaust probe, 335mm (13in) immersion depth
• MARPOL 73/78 Annex VI: Appendix IV – Type ap- with 2.2m (7ft) special hose for NOx/SOx measurement
proval and operating limits for shipboard incinerators • Control unit
(O2 in combustion chamber; CO in flue gas) • Control unit cable connection, 4.9m (16ft)
• Rechargeable NiMH battery pack
• MARPOL 1997 Resolution 2: Chapter 6 – Demonstrat- • Thermal printer paper, 6 rolls
ing compliance with NOx emission limits on board • Particle filters, 20 pieces
• Carrying belt set for analyzer box and control unit
• MARPOL 1997 Resolution 5: Consideration of mea- • Heavy-duty storage case
sure to address sulphur deposition (SOx) in north-west • Instruction manual
Europe • easyEmission software with RS232 cable for computer
connection
• MARPOL 1997 Resolution 8: CO2 emissions from
ships

Configuration
The DREW™/testo 350 emission analyzer has been config-
ured with regulatory requirements in mind as it comes standard
with O2, NOx (NO+NO2), SO2, CO and CO2 (NDIR) sensors.
The portability of the analyzer allows multiple sampling loca-
tions to be monitored. Wherever necessary, such as when
entering and/or operating in SECA, official records can be
produced and kept for regulatory compliance. These records
are then available for local authorities to inspect.

As regulations continue to evolve, the versatility of the


DREW/testo 350 Emission Analyzer allows additional
sensors to be easily swapped in and out of the analyzer in
matter of seconds.

Furthermore, additional analyze boxes can be added for


simultaneous monitoring of more than one exhaust stack
location using a single control unit.

®
Registered trademark, TMTrademark, Drew Marine
©
2010 Drew Marine • All Rights Reserved • DREW/testo 350 PDS 0612 R0
www.drew-marine.com

All statements, information and data presented herein are believed to be accurate and reliable but are not to be taken as a guarantee, express warranty or implied warranty of merchantability
or fitness for a particular purpose, or representation, express or implied, for which seller assumes legal responsibility, and they are offered solely for your consideration, investigation and
verification. Statements or suggestions concerning possible use of this product are made without representation or warranty that any such use is free of patent infringement and are not
recommendations to infringe on any patent.

DREW MARINE • 100 South Jefferson Road, Whippany, NJ 07981 USA • Tel: (1-973) 526-5700