Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

FR301 THRU FR307: Fast Recovery Rectifier

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

FR301 THRU FR307

FAST RECOVERY RECTIFIER


Reverse Voltage - 50 to 1000 Volts Forward Current - 3.0 Ampere

FEATURES
DO-201AD
● The plastic package carries Underwriters Laboratory
Flammability Classification 94V-0
● Fast switching for high efficiency
● Low reverse leakage
● High forward surge current capability 1.0 (25.4)
MIN.
● High temperature soldering guaranteed:

● 250 C/10 seconds,0.375”(9.5mm) lead length, 0.220(5.6)


0.197(5.0)
5 lbs. (2.3kg) tension DIA.

0.375(9.6)
0.285(7.2)

MECHANICAL DATA
Case: JEDEC DO-201AD molded plastic body
Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026 1.0 (25.4)
MIN.
Polarity: Color band denotes cathode end
Mounting Position: Any 0.052(1.3)
Weight:0.04 ounce, 1.10 grams 0.048(1.2)
DIA.

Dimensions in inches and (millimeters)

MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS


Ratings at 25 C ambient temperature unless otherwise specified.
Single phase half-wave 60Hz,resistive or inductive load,for capacitive load current derate by 20%.
FR FR FR FR FR FR FR
Characteristic SYMBOLS
301 302 303 304 305 306 307 UNITS
Maximum repetitive peak reverse voltage VRRM 50 100 200 400 600 800 1000 V
Maximum RMS voltage VRMS 35 70 140 280 420 560 700 V
Maximum DC blocking voltage VDC 50 100 200 400 600 800 1000 V
Maximum average forward rectified current
I(AV) 3.0 A
0.375”(9.5mm) lead length at TA=75 C
Peak forward surge current
8.3ms single half sine-wave superimposed on IFSM 200.0 A
rated load (JEDEC Method)
Maximum instantaneous forward voltage at 3.0A VF 1.3 V
Maximum DC reverse current TA=25 C 5.0
IR µA
at rated DC blocking voltage TA=100 C 100.0
Maximum reverse recovery time (NOTE 1) trr 150 250 500 ns
Typical junction capacitance (NOTE 2) CJ 60.0 pF
Typical thermal resistance (NOTE 3) R JA 20.0 C/W
Operating junction and storage temperature range TJ,TSTG -65 to +150 C
Note:1.Reverse recovery condition IF=0.5A,IR=1.0A,Irr=0.25A
2.Measured at 1MHz and applied reverse voltage of 4.0V D.C.
3.Thermal resistance from junction to ambient at 0.375”(9.5mm)lead length,P.C.B. mounted
FR301 THRU FR307
RATINGS AND CHARACTERISTIC CURVES

FIG. 1- FORWARD CURRENT DERATING CURVE FIG. 2-MAXIMUM NON-REPETITIVE PEAK FORWARD
AVERAGE FORWARD RECTIFIED CURRENT,

SURGE CURRENT
3.0 200

PEAK FORWARD SURGE CURRENT,


2.4 160
AMPERES

1.8

AMPERES
120

1.2 Single Phase


Half Wave 60Hz 80
Resistive or
inductive Load

0.6 8.3ms SINGLE HALF SINE-WAVE


40
(JEDEC Method)

0
0 25 50 75 100 125 150 175 0
1 10 100

AMBIENT TEMPERATURE, C NUMBER OF CYCLES AT 60 Hz

FIG. 3-TYPICAL INSTANTANEOUS FORWARD FIG. 4-TYPICAL REVERSE CHARACTERISTICS


CHARACTERISTICS
1,000
20
10
INSTANTANEOUS REVERSE CURRENT,
INSTANTANEOUS FORWARD

100
CURRENT,AMPERES

MICROAMPERES

1
10

TJ=100 C
0.1 TJ=25 C 1
PULSE WIDTH=300 ms
1%DUTY CYCLE

0.1
0.01
0.6 0.8 1.0 1.2 1.4 1.5 TJ=25 C

0.01
0 20 40 60 80 100
INSTANTANEOUS FORWARD VOLEAGE,
VOLTS PERCENT OF PEAK REVERSE VOLTAGE,%

FIG. 5-TYPICAL JUNCTION CAPACITANCE FIG. 6-TYPICAL TRANSIENT THERMAL IMPEDANCE


200
TRANSIENT THERMAL IMPEDANCE,

100

100
JUNCTION CAPACITANCE, pF

10
C/W

TJ=25 C
10
1

0.1
0.01 0.1 1 10 100
1
0.1 1.0 10 100
REVERSE VOLTAGE,VOLTS
t,PULSE DURATION,sec.