Declaration of Conformity: Contractor 3D Standard Non-Belted FBH
Declaration of Conformity: Contractor 3D Standard Non-Belted FBH
Declaration of Conformity: Contractor 3D Standard Non-Belted FBH
Alexander Andrew, Inc. declares that the product(s) listed above is in conformity with
the requirements of the following performance standard(s):
ANSI Z359.11-2014
Level 1: FallTech Lab Level 2: FallTech Lab Level 3: Independent 3rd Party Lab
Outside the Scope of Within the Scope of accredited to
ISO/IEC Standard 17025:2005 ISO/IEC Standard 17025:2005 ISO/IEC Standard 17025:2005
Supporting
Documentation
PC-0777
Authorized Signature
Material/Sample Identification
Sample ID Description
242061 Full Body Harness
241980 Full Body Harness
241860 Full Body Harness
2477763 Full Body Harness
241912 Full Body Harness
241992 Full Body Harness
241694 Full Body Harness
2412381 Full Body Harness
242136 Full Body Harness
2478060 Full Body Harness
242039 Full Body Harness
2477730 Full Body Harness
FLT-08 Rev. F
Certificate# TL-594 Testing Page 1 of 12
FallTech Testing Laboratory
1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
Test Summary
Test Specification Test Criteria Test Result Pass/Fail
Static Strength
3600 Lbf > 1 Minute 3658.2 Lbf Pass
(Dorsal D-ring)
Static Strength Harness Shall Not Release Test
Did Not Release Pass
(Dorsal D-ring) Torso
ANSI Z359.11-2014 Adjuster Slippage Slippage < 1" 0.0" Pass
4.3.5 Shall Not Tear a Distance
Tear Distance Greater Than to Adjacent Did Not Tear Through Pass
Eyelet
Straps Shall Not Show Any
Tearing Did Not Tear Pass
Signs of Tearing
Static Strength
3600 Lbf > 1 Minute 3644.7 Lbf Pass
(Dorsal D-ring)
Static Strength Harness Shall Not Release Test
Did Not Release Pass
(Dorsal D-ring) Torso
ANSI Z359.11-2014 Adjuster Slippage Slippage < 1" 0.0" Pass
4.3.5 Shall Not Tear a Distance
Tear Distance Greater Than to Adjacent Did Not Tear Through Pass
Eyelet
Straps Shall Not Show Any
Tearing Did Not Tear Pass
Signs of Tearing
Static Strength
3600 Lbf > 1 Minute 3691.7 Lbf Pass
(Dorsal D-ring)
Static Strength Harness Shall Not Release Test
Did Not Release Pass
(Dorsal D-ring) Torso
Adjuster Slippage Slippage < 1" 0.0" Pass
ANSI Z359.11-2014
4.3.5 Shall Not Tear a Distance
Tear Distance Greater Than to Adjacent Did Not Tear Through Pass
Eyelet
Straps Shall Not Show Any
Tearing Did Not Tear Pass
Signs of Tearing
FLT-08 Rev. F
Certificate# TL-594 Testing Page 2 of 12
FallTech Testing Laboratory
1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
Static Strength
3600 Lbf > 1 Minute 3647.3 Lbf Pass
(Side D-ring)
Static Strength Harness Shall Not Release Test
Did Not Release Pass
(Side D-ring) Torso
Adjuster Slippage Slippage < 1" 0.0" Pass
ANSI Z359.11-2014
4.3.5 Shall Not Tear a Distance
Tear Distance Greater Than to Adjacent Did Not Tear Through Pass
Eyelet
Straps Shall Not Show Any
Tearing Did Not Tear Pass
Signs of Tearing
Static Strength
3600 Lbf > 1 Minute 3649.4 Lbf Pass
(Side D-ring)
Static Strength Harness Shall Not Release Test
Did Not Release Pass
(Side D-ring) Torso
Adjuster Slippage Slippage < 1" 0.0" Pass
ANSI Z359.11-2014
4.3.5 Shall Not Tear a Distance
Tear Distance Greater Than to Adjacent Did Not Tear Through Pass
Eyelet
Straps Shall Not Show Any
Tearing Did Not Tear Pass
Signs of Tearing
Static Strength
3600 Lbf > 1 Minute 3647.2 Lbf Pass
(Side D-ring)
Static Strength Harness Shall Not Release Test
Did Not Release Pass
(Side D-ring) Torso
Adjuster Slippage Slippage < 1" 0.0" Pass
ANSI Z359.11-2014
4.3.5 Shall Not Tear a Distance
Tear Distance Greater Than to Adjacent Did Not Tear Through Pass
Eyelet
Straps Shall Not Show Any
Tearing Did Not Tear Pass
Signs of Tearing
FLT-08 Rev. F
Certificate# TL-594 Testing Page 3 of 12
FallTech Testing Laboratory
1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
FLT-08 Rev. F
Certificate# TL-594 Testing Page 4 of 12