Coiled Tubing Surface Equipment PPT
Coiled Tubing Surface Equipment PPT
Coiled Tubing Surface Equipment PPT
• Surface equipment
• BHA assemblies
Injector
Operator’s Cab Reel
Junction weld
in flat strip
Bias weld
in flat strip
PRESSURE BLEED
ON
60 GPM
TOP OFF PUMP
TUBING WEIGHTINDICATOR
ON PRESSURE
OFF OFF THROTTLE
ON CIRCULATING PRESSURE WELLHEAD PRESSURE
REEL BRAKE
OFF
INSIDE TRACTION
BOP SUPPLY SUPPLY PRESSURE
AIR HORN
BOP PRESSURE BOP SUPPLY PRESSURE
MIDDLE INSIDE TRACTION
PRIORITY PRESSURE INJECTOR DIRECTIONAL Sc hlum berger
ON PRESSURE 2,000 PSI MAX CONTROL VALVE
STRIPPER STRIPPER PILOTPRESSURE Dowell REEL PRESSURE
#2 #1 OFF PRESSURE ADJUST
IN INJECTOR CHAIN
LUBRICATION
RETRACT NEUTRAL PACK RETRACT NEUTRAL PACK
UP HIGH
Looks more complex, but main data is from load, wellhead pressure and annular pressure.
Main controls are injector head and coil spooling.
– Weight Indicator
• displays weight exerted by the tubing on the injector head
B
George E. King Engineering
3/14/2009 37
GEKEngineering.com
George E. King Engineering
3/14/2009 38
GEKEngineering.com
George E. King Engineering
3/14/2009 39
GEKEngineering.com
Selected Reel Diameter Information
Reel Information for Various Sizes of CT
CT Diam. Reel Hub Diam. Guide Arch (Reel Width) Approx. Capacity
(in) (in) (in) (in) (ft)
0.75 48 48
1 60 48-54
1.25 72 48-72 117 17500
1.5 84 (48)-72 128 15000
1.75 96 72-96 148 18000
2 96 72-96
2.375 108 90-120
2.875 108 90-120
3.5 120 90-120
72-in. radius
120-in. radius (HR 260)
(HR 480)
50-in. radius
(HR 240)
0.750 24 48
1.000 20-30 48-54
1.250 25-36 48-72
1.500 30-40 48-72
1.750 35-48 72-96
2.000 40-48 72-96
2.375 48-54 90-120
2.875 54-58 90-120
3.500 65-70 96-120
Gooseneck or guide-arch
Stripper assembly
Incorrect
Correct
100
90
80
0.108”
Load Necessary, lbs
70
0
60
0
50
0
40 0
30
20 0.072”
10
0
0 2000 4000 6000 8000 10000 12000
Wellhead Pressure, psi
Pressure Induced Snubbing Force VS Well Head Pressure for Various Coiled
Tubing Sizes, (Must add stripper friction force)
160000
140000
1" CT
Base Snubbing Force, lbs
120000 1-1/4" CT
1-1/2" CT
100000
1-3/4" CT
80000 2" CT
2-3/8" CT
60000
2-7/8" CT
40000 3.5" CT
20000
0
0 2000 4000 6000 8000 10000 12000 14000 16000
Well Head Pressure, psi
George E. King Engineering
3/14/2009 69
GEKEngineering.com
George E. King Engineering
3/14/2009 70
GEKEngineering.com
Gap between the injector and
the stuffing box – The pipe in
this area is very susceptible
to bending – Note the brace
around the CT.
• total =10835 lb
at start of the CT run-in