Photovoltaic PV1-F DC Solar Cable

APPLICATION
Solar cable intended for the interconnection within photovoltaic systems such as solar panel arrays.
Suitable for fixed installations, internal and external, within conduit or systems, but not direct burial applications.
Our solar cable is ozone-resistant according to BS EN 50396, UV resistant according to HD 605/A1, and is tested
for durability according to EN 60216. The cable is designed to last at least 25 years.
For installations where fire, smoke emissions and toxic fumes create a potential risk to life and equipment.

CONSTRUCTION
Conductor
Class 5 flexible tinned copper conductor
Insulation
Halogen-free cross-linked compound Black or White
Sheath
Halogen-free cross-linked, flame retardant compound Black or Red

STANDARDS
TÜV listed as PV1-F, TÜV 2 ,
IEC 60228/VDE 0295, HD 605/A1, BS EN 60754-1,
BS EN 60754-2, BS EN 60684-2, BS EN 61034,
BS EN 50396, BS EN/IEC 60332-1-2, BS EN/IEC 60216-1

CHARACTERISTICS
Voltage Rating (Uo/U)
AC: 600/1000V DC: 900/1800V
Temperature Rating
Fixed: -40°C to +90°C
Minimum Bending Radius
Fixed: 4 x overall diameter Flexed: 5 x overall diameter
Maximum Voltage (Umax)
1.8kV DC (conductor/conductor, non earthed system, circuit not under load)
Maximum Conductor Temperature
+120°C (for 20000h)
Test Voltage
6.5kV AC according to BS EN 50395
DIMENSIONS

NOMINAL
CROSS NOMINAL OVERALL
NO. OF NOMINAL WEIGHT
SECTIONAL DIAMETER
CORES kg/km
AREA mm
mm²
1 2.5 4.5 39
1 4 5.3 57
1 6 6.0 80
1 10 7.0 122
1 16 8.3 181
1 25 9.7 273
1 35 11 364
1 50 13.2 520
1 70 15.4 713
1 95 17.4 930
1 120 20.1 1191
1 150 22.5 1514
1 185 26 1828
1 240 26.8 2324

Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables

CURRENT CARRYING CAPACITY


NOMINAL CROSS SECTIONAL MAXIMUM RESISTANCE OF
AREA CONDUCTOR AT 20ºC
Metal-Coated Wires In Air
mm²
ohms/km Amps
2.5 8.21 41
4 5.09 55
6 3.39 70
10 1.95 98
16 1.24 132
25 0.795 176
35 0.565 218
50 0.393 276
70 0.277 347
95 0.21 416
120 0.164 488
150 0.132 566
185 0.108 644
240 0.0817 775
Flexible Earth Cable RV

DESCRIPTION
Power and control cable, PVC, 450/750V, wiring of devices and control cabinets, flame-retardant,
class 5/ fine wire, fixed installation, ring/spool

APPLICATION
Laying in tubes, exposed or buried in plaster, and in closed installation ducts
For direct laying on racks, troughs and tubes only as potential equalisation conductor

CONSTRUCTION
Fine-wired copper conductor of bare copper strands in line with conductor class 5 acc. IEC 60228
Core insulation: Based on PVC

DATA

ETIM 5.0 Class-ID: EC000993


Classification ETIM 5:
ETIM 5.0 Class-Description: Single core cable

ETIM 6.0 Class-ID: EC000993


Classification ETIM 6:
ETIM 6.0 Class-Description: Single core cable
Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5
According to EN 50565-1
Conductor stranding: OD ≤ 8 mm: 4 x OD*/2 x OD**;
Minimum bending radius: 8 < OD ≤ 12 mm: 5 x OD*/3 x OD**;
OD > 12 mm: 6 x OD*/4 x OD**

U0/U: 450/750V
Nominal voltage:
2000 V
Test voltage:
VDE 0298 Part 4
Current rating:
EN 50565-1/ VDE 0298-565-1
Fixed installation: -40°C to +80°C
Temperature range:
Moved: +5°C to +70°C
Description Unit Request

1C*400mm2
Specification -

- Copper Wire Stranded IEC 60228 cl.5


Conductor

Wire max. mm 0.51

Diameter mm 30.0

- PVC Flame retardant & UV Protection


Insulation

- Black
Color

Nominal thickness mm 2.60

mm 35.2
Outer Diameter Approx.

Ω/km 0.0486
Max. conductor resist.@20℃
35kV 1 Core Armored XLPE Power Cable

APPLICATION
Power cables for power networks, underground direct buried and in cable ducting.

CONSTRUCTION
Conductor Class 2 stranded aluminum conductor according to IEC/BS EN 60228
Conductor Screen Semi-conductive screen material
Insulation XLPE (Cross-Linked Polyethylene) Type GP8 according to BS 7655
Insulation Screen Semi-conductive screen material
Metallic Screen Copper tape screen according to BS 6622
Wrapping tape Non-woven fabrics tape
Inner bedding PVC Polyolefin according to IEC 60502
Armour Aluminum wire 1350-H19
Outer Sheath PVC Polyolefin according to IEC 60502

CHARACTERISTICS
Design IEC 60502-2
Voltage Rating 35 kV
Temperature Rating -5°C to +90°C
Minimum Bending Radius 12 x overall diameter
Flame retardant IEC 60332-1
Sheath Colour Black
Specification

Size Unit 1C*300mm2 1C*150mm2 1C*120mm2

Conductor - -

-Material - Aluminum wire cl.2

-Conductor diameter mm 20.5 14.4 13.0

Conductor shield - Extruded Semi-conductive layer

-Nominal thickness mm 0.8

Insulation - -

-Material - Extruded XLPE

-Nominal thickness mm 10.5

Insulation shield - Extruded Semi-conductive layer

-Nominal thickness mm 0.8

Metallic shield - Soft Copper Tape

-Tape thickness mm 0.12

Wrapping tape - Water block Non-woven fabrics tape

Inner Sheath - PVC

-Color - Black

-Nominal thickness mm 1.5 1.4 1.3

Armored - Aluminum wire

-Wire diameter mm 2.5

Outer Sheath - PVC

-Color - Black

-Nominal thickness mm 2.8 2.6 2.5


-Approximate overall
diameter mm 59.0 53.0 51.0
Electrical
Characteristics - -
-D.C resistance at 20°C
of conductor ≤ Ohm/Km 0.100 0.206 0.253

-Test voltage - 91kV/5Min(Not Broken)


CU / PVC (single core) Earth Cable
PVC Insulated, Non-Sheathed Cable, 450 / 750V, BS 6004, BS EN50525-2-31, IEC60227

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded

Insulation: Polyvinyl Chloride (PVC) Compound Type C

ELECTRICAL CHARACTERISTICS

Operating Voltage, Uo/U: 450/750V

Operating Temperature: -15ºC to 70ºC

Final Short Circuit Temperature: 160ºC for cable ≤ 300mm2

Test Voltage: 2kV for 5 minutes

REFERENCE STANDARDS

Design Specification: BS 6004, BS EN50525-2-31, IEC60227

Conductor: IEC60228, BS EN60228

Flame Retardant: IEC60332-1, BS EN60332-1

INSTALLATION REFERENCE

Up to 10mm²: 3 x overall diameter

10mm² to 25mm²: 4 x overall diameter

Above 25mm²: 5 x overall diameter

COLORS

Red Black Blue Yellow White Green/Yellow Grey Brown


DIMENSIONS

NOMINAL THICKNESS
NOMINAL CROSS NOMINAL OVERALL
OF NOMINAL WEIGHT
SECTIONAL AREA DIAMETER
INSULATION kg/km
mm² mm
mm

1.5 0.7 2.9 22


2.5 0.8 3.6 32
4 0.8 4.1 50
6 0.8 4.7 71
10 1 5.9 110
16 1 6.8 164
25 1.2 8.4 256
35 1.2 9.4 346
50 1.4 11 473
70 1.4 12.7 674
95 1.6 14.7 913
120 1.6 16.2 1150
150 1.8 18 1416
185 2 20 1749
240 2.2 23 2317
300 2.4 25.2 3049
400 2.6 28.4 3657
500 2.8 31.8 4700
630 2.8 38.1 5890
Bare Annealed Copper
STRANDED PLAIN ANNEALED COPPER CONDUCTOR ( SINGLE CORE )
IEC60228, ASTM B3

APPLICATIONS
Bare Copper conductors are primarily used for grounding purposes as specified in the
National Electrical Code.
Soft-drawn solid or stranded conductors, for use as grounding connections in circuits, and
grounding for machinery or equipment.
Hard-drawn conductors for overhead transmission and distribution lines, as grounding
connections in circuits, and grounding for machinery or equipment.

SPECIFICATIONS
Following ASTM specifications:
• B-1 Hard-Drawn Copper Wire.
• B-2 Medium-Hard Copper Wire.
• B-3 Soft or Annealed Copper Wire.
• B-8 Concentric-Lay-Stranded Hard, Medium-Hard or Soft Copper Conductor.
• B-33 Tinned Conductors
• B-787 19 Wire Combination Unilay-Stranded Soft copper wire.
• ASTM B172, NTC 1865 ASTM B174, NTC 1817 Flexible conductors Class K and M
• IEC 228 for sizes in mm2.

CONSTRUCTION
Bare copper, solid or stranded. Available in tempers hard, medium-hard, or soft. Stranded conductors
are concentrically stranded in hard and medium-hard tempers and are Combination Unilay stranded
in the soft-drawn temper.

FEATURES
For grounding electrical systems where high conductivity and flexibility is required.
Suitable for numerous other applications.
Parameter

-IEC
RV-K - BS EN 60502-1 XLPE PVC Cable

APPLICATION
The RV-K cable is for power distribution and can be used for all types of low voltage industrial-type connections,
building installations, in urban grids, etc. This cable is particularly suitable for use in challenging layouts because
of its high flexibility, also making the installation process substantially easier.
It can be buried or installed in a tube as well as outdoors without requiring additional protection.
The RV-K cable withstands damp conditions.

CHARACTERISTICS
Voltage Rating (Uo/U)
0.6/1kV
Temperature Rating
-15ºC to +90ºC
Minimum Bending Radius
Fixed: 5 x overall diameter

CONSTRUCTION
Conductor
Class 5 flexible copper conductor
Insulation
XLPE (Cross-Linked Polyethylene)
Sheath
PVC (Polyvinyl Chloride)
Core Identification
3 core: Green/Yellow Blue Brown
4 core: Green/Yellow Brown Black Grey
5 core: Green/Yellow Blue Brown Black Grey
7 core and above: Black with White numbers
Sheath Colour
Black

STANDARDS
IEC 60502-1, UNE 21123-2
Flame retardant according to BS EN/IEC 60332-1-2
Size Unit 4C*6mm2

Conductor - -

-
-Material Annealed Stranded Copper Wire IEC 60228 cl.5

-Diameter mm 3.8

-
Insulation -

-
-Material Flame retardant XLPE

-
-Identification Color code

-Nominal thickness mm 0.7

Outer Sheath - -

-
-Material Flame retardant/UV Protection PVC

-
-Sheath Color Black

-Nominal thickness mm 1.8

Finished Cable - -

-Approximate overall diameter mm 16.0

Electrical Characteristics - -

-D.C resistance at 20°C ≤ Ohm/Km 3.30

-Test voltage - 3.5kV/5Min


Fiber Optic Cable GYTA53 Series

GYTA53 outdoor fiber optic cable is steel tape armored, used for direct buried indoor/outdoor.

We supply single mode GYTA53-24B1 fiber optic cable and multimode GYTA53-24A1b fiber optic cables.

Construction as central strength member (steel), jelly filled, fiber contained loose tube and PP

filler (if necessary) stranded, water blocking jelly, copolymer coated aluminum tape, PE inner sheath, longitudinally

covered by copolymer coated steel tape, PE outer sheath.

Features:

♦ Low dispersion and attenuation

♦ Proper design, precise control for fiber excess length and distinct stranding process render the cable excellent

mechanical and environmental properties

♦ Double-jacket structure make cable have nice properties of moisture resistance and crush resistance

♦ With small cable diameter, light cable weight, easily to lay

♦ Operating Temperature : -20 ~ +60 C

Good mechanical and temperature performance

• Stranded loose tube improves the tensile strength

• Metal strength member provides excellent strain performance

• Double-jacket structure ensures moisture resistance and crush resistance

• Steel tape and aluminum tape enhances water-blocking & moisture-proof performance

Applications:

♦ Laying modes: Direct Buried

♦ Long-distance communication, local trunk line, CATV & computer networks system

• Used for duct and buried laying method

• Adopted to outdoor distribution

• Specially used where good mechanical performance and rodent resistance are expected
Fiber properties in cable

Specifications
Category Description
After cabling
Attenuation @1310 nm
≤0.35/0.37 dB/km
(No-wired/Wired)
Attenuation @1550 nm
≤0.21/0.23 dB/km
(No-wired/Wired)
Zero Dispersion Wavelength 1300~1324 nm

Zero Dispersion Slope ≤ 0.092 ps/nm2∙km

PMD Link value of fiber individual ≤0.18 ps/√km

Optical PMDq (Q=0.01% N=20) ≤0.08 ps/√km


Specifications
Cable Cutoff Wavelength (λcc)
≤1260 nm
1100-1320 nm
Dispersion coefficient at 1285-1330 nm ≤3.5 ps/nm.km

Dispersion coefficient at 1550 nm ≤18.0 ps/nm.km

Dispersion coefficient at 1625 nm ≤22.0 ps/nm.km

Macro bending Loss


≤ 0.05 dB
(100 turns; Ф50 mm) @1550 nm
≤ 0.10 dB
(100 turns; Ф50 mm) @1625 nm

Mode Field Diameter @1310 nm 9.2±0.4μm

Mode Field Diameter @1550 nm 10.4±0.5μm

Cladding Diameter 125 ±1.0μm


Dimensional
Specifications Core/clad concentricity error ≤0.6μm

Coating/cladding concentricity error ≤12μm

Cladding Non-Circularity ≤1%

Coating diameter (colored) 250 ±15 μm

Allowable tensile Long term 1000N/Short term 3000N

Long term 1000N/100mm


Allowable crush
Short term 3000N/100mm
Static: 10 x cable diameter
Min. bending radius Dynamic: 20 x cable diameter
Mechanical
Specifications -20℃ ~ +60℃

Temperature range
Descriptions
Single mode GYTA53-8B1 & Multimode GYTA53-24A1b
1. PBT loose tube of 8-24 fibers
Fiber core: Singlemode with G652 9/125μm; Multimode with G651 62.5/125μm
Tube number: 4, Tube thickness: 0.35mm Diameter: 2.1μm
UV color fiber: Standard chromatogram
2. Filling Compound
3. Central Strength member: steel wire Diameter: 1.5mm
4. Filler rod
5. APL: Aluminum Polyethylene Laminate moisture barrier, thickness 0.25mm
6. Black MDPE inner sheath, Ave. Thickness 1.0mm
7. Water-blocking tape
8. PSP: Longitudinal corrugated steel tape laminated with polyethylene on both sides, thickness: 0.22mm
9. MDPE outer sheath, Ave.thickness: 2.0mm
Cable Overall Diameter: 13.0mm

Structure
RS-485 Data Cables

Description
Electrically radiated noise frequently present in factory floor environments can interfere with device-to-device communication
circuits, causing delayed signals or data loss. One important factor in establishing a good, reliable communication circuit
is cable selection. AutomationDirect offers high quality, lowcapacitance data cables designed with impedances specific for
RS-485 communication applications in industrial environments. The 24 AWG tinned copper conductors are twisted pairs to reduce
electrical noise sensitivity and are available in one, two, or three-pair color coded constructions.
The polyethylene conductor insulation provides a very high insulation resistance with a low, stable dielectric constant resulting in lower
capacitance and excellent velocity of propagation for superior signal transmission.
To protect from radiated or conducted electromagnetic interference (EMI), our data cables have combination shields consisting
of an overall foil shield layer with drain wire and a woven braid shield layer. The overall foil shield has 100% cable coverage
for excellent protection against higher frequency noise. A drain wire is provided to easily terminate and ground the foil shield.
A second shield layer consists of a woven braid that is ideal for minimizing low frequency interference while providing superior
structural integrity to the overall cable. Our combination foil/ braid shielded cables offer maximum shield effectiveness across
the frequency spectrum compared to other single layer shielded cables. The rugged gray PVC jacket is durable enough for use in
demanding industrial applications.

Features
• Low capacitance data cables for RS-485 applications in industrial environments
• Color coded 24 AWG tinned copper twisted pair conductors to reduce electrical noise sensitivity
• Polyethylene insulation provides a very high insulation resistance with a low, stable dielectric constant
• Combination overall foil shield with tinned copper drain wire plus tinned copper braid shield maximizes shielding
effectiveness compared to single layer shielded cables
• Rugged gray PVC jacket provides durability in demanding installations
• UL CM/CL2 or AWM Style 2919