1. All Sanitary works shall conform with the prevailing requirements of local ordinances and national laws.
1/4 BEND ELBOW
2. Read the drawings in connection with other related drawings and specifications.
The Architech and the Engineer shall be notified immediately of any descripancies found therein.
3. The Contractor shall determine the actual location, depth and invert elevation of exixsting pipes and MOSQUITO NET
4. The Contractor shall be responsible for all required floor and wall openings.
OPEN OPEN
5. All pipes shall be installed as indicated. Any relocation required to proper execution of other trades VENT PIPE
shll be with prior approval of the Architech and the Engineer.
FD
6. All slope for horizontal pipes shall maintain 1% as minimum, unless otherwise noted. CO
WC
LAV
TAP TO METER 2 DN DN
7. All fixtures shall be vented, unless otherwise noted. GV WC LAV
GV WC
LAV
LAV
8. All pipes sizes indicated are in millimeter (mm) diameter, unless otherwise noted. WC
TAP TO METER 3 CO
FD
9. All underground G.I. water pipes shall be coated with (2) layer of asphalt with jute sack.
10. All water pipes shall be provided with 30 cm. pipe extension and capped at the end.
11. All water pipes shall be hydrostatically tested to pressure of 1034 kpa for two (2) hours. OPEN OPEN 03 VENT PIPE DET.
P-01 SCALE: 1:20mts.
12. All water pipes shall be thoroughly flushed and disinfected.
SP
13. All Sanitary and stormdrainage pipes shall be hydrostatically tested to ensure thet the system are water tight. SP
14. WORKMANSHIP : The work throughout, shall be executed in the best and the most thorough manner
OPEN
known to trade and to the satisfaction of the Architect and the Engineer.
15. The Contractor shall be responsible for securing all government / local construction and operation permits and
pays all required fees. FD
CO
WC
LAV
TAP TO METER 4
GV WC LAV
LAV
GV WC
LAV PIPE SLEEVES
WC
TAP TO METER 5
CO
FLOOR SLAB
SPECIFICATION FD
1. COLD WATER PIPE - UNITEC PIPE, BELDEN or approved equal. OPEN OPEN
2. DOWNSPOUT - Polyvinyl chloride, series 1000 Emerald Crown pipe brand or approved equal.
MASTER
3. STORM DRAINAGE PIPE - interior polyvinyl chloride, series 1000 / class 35 Emerald or Crown pipe brand or approved equal. FILLER
PIPE HANGER
- Exterior concrete pipe, ASTM standard. WALL OR
BEAM
4. VENT PIPE / VENT STACK - Polyvinyl chloride, series 1000 Emerald Crown pipe brand or approved equal.
5. SOIL AND WASTE PIPES - Polyvinyl chloride, series 1000 Emerald Crown pipe brand or approved equal.
6. PIPE SEALANT - Polyvinyl chloride Solvent Cement 400 cc.
7. VALVES - 20 up to 50 mm - bronze ASTM B 62,860 kpa class, Threaded end. 01 PLUMBING LAYOUT 02 SANITARY LAYOUT CLEAN OUT
P-01 SCALE: 1:100mts. P-01 SCALE: 1:100mts.
LEGEND
WM- WATER METER CWR- COLD WATER RISER CWDF- COLD WATER DOWN FEED
04 PIPE HANGER DETAIL
GV- GATE VALVE KSK- KITCHEN SINK SS- SOIL STACK P-01 SCALE: 1:20mts.
CV- CHECK VALVE UDP- UNDER DRAIN PIPE %S- % SLOPE
CWL- COLD WATER LINE WS- WASTE STACK FD- FLOOR DRAIN
WP- WASTE PIPE SP- SOIL PIPE VTR- VENT THRU ROOF
PD- PIPE DOWN LAV- LAVATORY ADCB- AREA DRAIN CATCH BASIN SCREW PLUG
CONCRETE SLAB
AC- AIR CHAMBER GATE VALVE FIN. FLOOR LEVEL COVER AND FRAME
PU- PIPE UP CDP- CONCRETE DRAIN PIPE
WATER METER FINISH FLOOR LINE
FCO- FLOOR CLEAN OUT GT- GREASE TRAP SDL- STORM DRAINAGE LINE UNION PATENTE
CCO- CEILING CLEAN OUT DD- DECK DRAIN VP- VENT PIPE IRON BODY FERRULES
W/ BRASS SCREW
PLUG
GCO- GROUND CLEAN OUT VAC- VENT ABOVE CEILING HB- HOSE BIBB
PVC PIPE