Power Protection 70100 R06 11
Power Protection 70100 R06 11
Power Protection 70100 R06 11
2
There Is A Liebert Power Solution
Desktops / Peripherals
To Meet Every Need
Emergency Shelters
Computer Rooms
Network Closets
Telecom / CATV
Labs & Testing
Point-Of-Sale
Data Centers
Production
CONTENTS
2 Rack PDU
16 Liebert MPX Adaptive Rack PDU
17 Liebert MPH Managed Rack PDU
18 Liebert MPX And Liebert MPH
19 Knurr DI-STRIP, Basic Rack PDU
3
Trouble Is Coming Down The Power Line And You Must Be Prepared
Every operation in your business depends upon the instant, You Face Many Challenges In The
around-the-clock availability of computers, servers and other Pursuit Of Productivity
electronic systems. If they aren’t working, neither is your company.
Is There Really A Problem?
Unfortunately, every piece of this equipment your company “My computer can ride right through a short blip
possesses is subject to the whims of the electricity that powers it. in the power—why do I need anything else?”
The first step in taking control of this situation is to understand the threats
to your system reliability—and exactly what you can do about them.
Different Needs Require Different Power
Protection Configurations
“Should I have a small UPS for each workstation
or have everything on one large system.
Which is best for my facility?”
We have efficient, high availability Liebert has identified ten distinct zones or areas of application, found
power solutions for any of the within many business operations, which have a requirement for
mission-critical power technology. While these zones have similarities
applications that are part of your
in the importance of their essential functions, they also have
mission-critical business operations.
different needs for infrastructure protection—all of which can be met
by Liebert solutions.
6
Telecom Wireline/Wireless Sites
Liebert can provide a reliable flow
UPStation
GXT
AC
INPUT
BATTERY
UPS
ON
BYPASS
UPStation
GXT
AC
INPUT
BATTERY
UPS
ON
BYPASS
UPStation
GXT
AC
INPUT
BATTERY
UPS
ONBYPASS
UPStation
GXT
AC
INPUT
BATTERY
UPS
ONBYPASS
Emergency Shelters
High-reliability Liebert UPS systems and DC
power equipment are critical to maintaining
operations in telecommunications shelters
and other unmanned structures. Network Operations
Centers
With many mission-critical
computing systems located
right in the office space,
there is a need for UPS
protection that can be
placed nearby. Liebert offers
a number of power systems
that are especially designed
for use in business and office
environments.
Network Closets
These densely-packed equipment UPStation
AC
UPStation
AC
GXT
INPUT
GXT
+
BATTERY
INPUT
UPS
BATTERY
ONBYPASS
AC
GXT
INPUT
BATTERY
UPS
ON
BYPASS
AC
GXT
INPUT
BATTERY
UPS
ON
BYPASS of UPS, distribution systems
and other power protection
equipment that can adapt
to data center growth
requirements.
Production
Liebert UPS, surge protection and power
distribution are all key to maintaining the
proper operation of process control and
Data Center UPStation
AC
UPStation
AC
GXT
INPUT
GXT
INPUT
BATTERY
BATTERY
UPS
UPS
ON
ON
BYPASS
BYPASS
AC
INPUT
BATTERY
UPS
ON
BYPASS
AC
INPUT
BATTERY
UPS
ON
BYPASS
UPStation
GXT
AC
INPUT
BATTERY
UPS
ON
BYPASS
UPStation
GXT
AC
INPUT
BATTERY
UPS
ON
BYPASS
AC
INPUT
BATTERY
UPS
ON
BYPASS
Mechanical Rooms
Liebert power protection and conditioning
systems can greatly improve the operation
of electrical switchgear and motor control
centers vital to numerous functions
throughout an industrial facility.
7
Efficiency Without Compromise ®
Expert Advice
INFRASTRUCTURE ritical infrastructure expertise enables highly
C
MANAGEMENT efficient and effective designs.
Uninterruptible Power
Areas of Opportunity
8
Design &
Deployment
Shorten Time
Minimize Space
Management
Operation
& Planning
Improve Performance Increase Availability
Increase Control Reduce Energy
Management Tools & Technologies Integration & Operation Services With more ways
rack, row and room sensor networks provide
IT, Implementation and commissioning services
to optimize
management and control of temp, humidity, ensure rapid deployment. data center
pressure, power, water detection, capacity,
and battery health.
E nterprise remote monitoring enables proactive
management.
infrastructure to
entralized real-time monitoring reduces
C Standards-based interface with Building Management
reduce design,
downtime and management. System bridges IT and facility management. management
and energy
costs while
Economization Critical Services
maintaining
F luid economizers enable “free cooling”
while controlling temperature, humidity, and
reventive maintenance optimizes
P
the lifetime value of equipment.
high availability
preventing contamination.
F acility Power Audits maximize efficiency
and flexibility,
L iebert Glycool safely uses outside temperatures
to reduce cooling system compressor runtime,
and availability. Emerson Network
saving up to 25% of energy cost.
Battery monitoring and service maximizes
performance, life, and availability.
Power delivers...
Efficiency
Variable Capacity Intelligent Control
Without
Liebert DS is the only data center cooling L iebert iCOM with predictive control and
Compromise
system to use variable capacity Digital Scroll teamwork saves up to 7% energy consumption
compressors. over traditional controls.
9
Knurr Racks And Cabinets
Low Profile
Casters
Allows 42U
Cabinet To
Roll Through
Standard
Doorway
10
Liebert MCR
Mini Computer Room Enclosure
Liebert IP Telephony
Availability System
Sealed Door
specially designed
rubber gasket
provides NEMA12
sealing protection
The Liebert GXT3, a true double conversion
Liebert GXT3 UPS, delivers the high level power quality
on-line UPS required to fully protect critical network
switching components from all power
problems. Available in sizes from 500 up
ECM to 3000 VA.
(Environmental
Control Module)
Continuous Power Availability
11
Smart Solutions Deliver Efficiency, Capacity,
Availability, Control
Space-savings, small-footprint
12
SmartRow™ The SmartRow™ solution has a room
Intelligent, integrated neutral design that lets you avoid many
infrastructure of the significant costs that come with a
in a self-contained line-up conventional data center buildout.
Smart Solutions
adding new equipment.
13
Liebert MB Modular Busway:
Flexible, Economical Power Delivery From PDU To Rack
Emerson Network Power brings you the most flexible, robust power
distribution system on the market today: Liebert MB Modular Busway.
System Compatibility
Liebert MB is compatible with the Knurr DCM rack and the entire family
of Liebert power products — rack and room PDUs, UPS systems and
surge protective devices — providing power distribution and protection.
Liebert MB Features:
Comprehensive offering of standard fittings.
Reconfigure to meet growing and changing IT demands.
Lightweight and flexible for easy installation, but rugged
enough for durability.
15-30% lower cost than typical cabling materials and
labor/installation costs.
UL 857 and CSA 22.2 agency ratings for safety.
100A, 225A and 400A availability.
Hot swappable, user replaceable bus plugs provide both
flexibility and maximum safety.
Bus plug capacities from 30A to 100A.
Pre-assembled bus plugs with whips or receptacles.
Multiple bus plug port spacing available. Liebert Power Monitoring Capabilities
Rack-mount, ceiling suspended or underfloor mounting options. The operation of Liebert MB can be monitored using:
Liebert SiteScan® Web Centralized Monitoring System.
Optional metering at bus plugs or tap box.
For more information, see pages 52 and 53.
14
Modular Power Distribution
Liebert NX Liebert Liebert Liebert MB
Battery Cabinet NX UPS Tap Box NX BDC Modular Busway Bus Plug
15
Liebert MPX - Adaptive Rack PDU:
Respond To Change While
Watching Your Bottom Line
Confidently take on the uncertain future of connected power Scalable Design Allows
requirements with Liebert MPX, the most responsive and adaptive Onsite Configuration
To Fit Immediate IT
rack PDU available. With Liebert MPX adaptive technology, you
Equipment Needs.
can economically increase availability of critical systems by
The Liebert MPX Adaptive
leveraging hot-swappable modular power and managing power
Rack PDU features essential
all the way to the receptacle level. characteristics to support
fast-paced, growing data centers.
Liebert MPX Benefits:
Adaptive capacity, distribution, monitoring,
Hot Swappable Output Power
control and management of critical devices. Deploy easily to get IT equipment
Flexibility to respond to constant change. online quickly
Buy only what you need and build on your investment.
Secure communication.
Receptacles & Modules
May be remotely controlled and
Reconfigurable Power Capacity metered, providing operator
& Distribution flexibility and allowing increased
site security
Liebert MPX is the perfect choice to respond to the needs
of a growing data center. Relocate or add IT equipment to
support changing needs, by easily reconfiguring the power Rack PDU Card (Liebert RPC)
Mounts in the Power Entry
input and distribution. Module and provides
upgradable network
Liebert MPX Features: communications, sensor
Industry leading operating temperature—up to 55˚C /131˚F and local display interface
16
Rack PDU Card
(Liebert RPC)
Provides upgradable
network communications,
Liebert MPH—Managed Rack PDU: sensor and local display
interface
Advanced Monitoring And Control Support
Liebert MPH is a flexible Rack PDU solution with remote Liebert MPH Features:
Rack PDU
monitoring and control capabilities as well as environmental Monitors electrical and
input options. It offers multiple power input selections environmental parameters with
and output configurations in both vertical zero-U and set threshold and alarm tools.
rackmount form factors. Up to four Liebert MPH PDUs may Industry leading operating
temperature—up to 55˚C/131˚F
be interconnected as a Rack PDU Array™, consolidating user
to support hot internal rack
IP connections and device monitoring. environments.
Controls and manages individual
Liebert MPH Monitoring
receptacles.
And Control Support
Predicts overcurrent conditions
Monitored electrical parameters include: voltage,
before they become critical.
current, total real power (watt), and energy
consumption (kW-hr). Capacity based current Remote monitoring at strip
and branch.
thresholds provide comprehensive alarm
notifications from the Rack PDU and branch. Card-based communications.
Local displays are easily located
to suit a crowded and changing
rack environment.
Supports mounting in 19” EIA,
42U rack environments—offered
in vertical, zero U and rackmount
form factors.
17
Monitoring Anywhere You Need It
From the individual receptacle of
each discrete device to the complete
Liebert MPX and Liebert MPH: rack PDU, monitoring is available
Enhanced Performance And Management to meet user needs. Displays are
designed for easy user location to fit
Of Dynamic IT Spaces changing site needs.
Display and sensors are designed
for easy mounting on the rack.
IT Space Is A Dynamic Environment Emerson Network Power’s portfolio of
A single display can manage up
products from brands such as Liebert,
Today’s successful businesses depend on to four Liebert MPX or Liebert
Knurr, Alber, Aperture, and ASCO provide
adaptable technologies to help them respond MPH systems and associated
innovative, flexible solutions that ensure
quickly to market demands. Your data center monitoring accessories. Liebert
reliability and efficiency. With the help of
must be built on a support infrastructure MPX and Liebert MPH include
monitoring and management tools from
designed to match the power and cooling the following capabilities:
Emerson Network Power, the result is
needs of rapidly changing IT initiatives such
an infrastructure that will enable you to Web-based monitoring.
as virtualization and consolidation. Each
proactively manage your critical IT spaces. Liebert Nform IT based.
IT change, move or addition will affect the
The Rack PDU family of products is the centralized monitoring.
entire support infrastructure. You need Liebert SiteScan centralized
connectivity point of IT systems into
products and support that ensure your monitoring.
your power and cooling infrastructure
IT systems will operate reliably in these User located local display with
and the critical interface to an efficient
environments. the ability to view up to four
M
and effective infrastructure management
structure anagement PDU’s.
Infra ecosystem.
Liebert SN rack sensors.
Surge
Protection
Cooling
Liebert RPC
(Rack PDU Card)
Network
18
Knurr DI-STRIP: Basic Rack PDU,
Standard And HighPower Systems
Knurr Basic Rack PDU is the right answer for data center users Knurr DI-STRIP Features:
Rack PDU
selecting robust, economical and flexible rack power solutions. ultiple configurations and input power options
M
available including international compatibility.
Knurr DI-STRIP® meets a broad range of power distribution requirements for IT and
he addition of the Basic Rack PDU Expansion
T
other applications. Designed especially to handle the growing number of electronic Unit allows for growth.
components that can be housed within network cabinets and server racks, the 0ft. (3m) power supply cable offers room
1
space saving product line is available with a range of accessories including circuit for movement.
breakers, overvoltage protection and more. Reliable and robust solution.
Worldwide approvals and certification.
F ull-length brass busbar on Standard models
enhances operational reliability.
tandard system extruded casing and a HighPower
S
system heavy duty casing provide durability.
I ndustry leading operating temperature—up to
55˚C/131˚F to support hot internal rack environments.
imple and quick installation on the rack’s extrusion
S
requires minimal space and reduces installation time.
Flexibility to meet
a broad range of
requirements
19
Liebert PSP Stand-by UPS:
350 - 650VA, 1-Phase
Protection For The PowerSure PSP from Liebert is a compact, full featured Liebert PSP Features:
UPS that delivers cost-effective power protection. Designed
Desktop And with simple controls for easy operation, the PowerSure PSP
Three battery-backed UPS outlets.
Small Network provides over four minutes of battery back-up at full load —
One surge protection-only outlet.
Applications more than enough time to save work in process and shut
Up to five minutes of battery
backup at full load.
Liebert desktop power solutions are down your system. User replaceable batteries.
designed for applications where one Perfect for desktop applications, the PowerSure PSP RJ-45 port for data line
or a few pieces of equipment require provides one-on-one power protection for PCs and surge protection.
surge suppression or basic power other sensitive electronic equipment. Two models Advance early warning of
available: 350 and 500VA at 120VAC and 500 and UPS shutdown.
protection with battery back-up.
650VA at 230 VAC. USB port, Liebert MultiLink
One-On-One Protection Software shutdown software
For maximum flexibility, a choice of communications
The Liebert family of products and USB cable.
options are available — USB, serial or contact closure. This
includes surge protection strips option solves the legacy systems dilemma of what to do Two-year replacement warranty.
and line-interactive UPS to give with equipment that does not have USB capabilities. A
you a real choice in desktop and MultiLink™ automated shutdown software CD, serial
network component protection. communications cable and USB cable are also included.
Liebert Products Offer
Stand-by UPS
One-On-One Power
Protection Solutions For:
TVSS & Load
Source EMI/RFI
Home And Small Office Filters
Desktop PCs. Battery Inverter
Network Workstations.
Point-of-Sale Terminals.
Other Sensitive Electronics.
Liebert Power Monitoring
Capabilities
20
Liebert PSA Line-Interactive UPS:
500 – 1500 VA, 1-Phase
Desktop UPS
Liebert PSA is an economical Other Standard Features Included
line-interactive UPS that offers On All Liebert PSA Models:
Three to six battery-backed UPS outlets,
full-featured power protection for
depending on model size.
small office computers and electronic
One to two surge-only outlets,
equipment. It is available in the differentiated by color.
following sizes: 500, 650, 1000 and Up to five minutes of battery backup time at full load.
1500 VA at 120 VAC or 230 VAC. User replaceable batteries.
Advance early warning of UPS shutdown. 500/650 VA back view
Designed with simple controls RJ-45 port for data line surge protection.
for easy operation, the Liebert Two-year warranty.
PSA provides up to five minutes
of back-up time at full load –
more than enough time to save
work in process and shut down Line-Interactive UPS
your connected equipment.
TVSS & AVR &
USB shutdown software and Source EMI/RFI Transfer Load
Filter Switch
a USB cable are also included,
to allow remote alerts and
automated graceful shutdown of Battery Inverter
the connected systems. Liebert
PSA offers unique features and
extraordinary performance not
1000/1500 VA back view
normally found in similar products
in this price range.
21
Liebert PSI And Liebert PSI-XR Line-Interactive UPS:
750-3000VA, 1-phase
Rack-Mounted
Power Solutions
For Growing IT
Networks
Rack-mounted servers are at the
heart of today’s network computing
systems. These critical components
need reliable, compact power
protection that will keep pace with
their growing needs.
22
4
Optional Liebert MicroPOD 2U POD
output distribution and maintenance
bypass module ensures continuous
uptime, even during UPS maintenance.
Line-Interactive UPS With Power-Factor Correction Liebert PSI-XR UPS With Internal Battery
Rack-Mount UPS
Liebert Input Output
TVSS & AVR & DB-9 IntelliSlot Circuit Circuit
Source EMI/RFI Transfer Load Port Port Breakers Breakers Receptacles
Filter Switch
Bi-directional
Battery
Converter
23
5
Liebert GXT3 On-Line UPS:
500-3000VA, 1-phase
Liebert GXT3 leads the industry in combining small customize Liebert GXT3 performance to your
size, high capacity and multiple features. Designed specific requirements, providing a new level
to be either rack-mounted or installed in a tower of power protection control and adaptability.
configuration, the UPS is available in 500, 700, 1000,
1500, 2000 and 3000 VA ratings, in both 120 V and Other Features Of Liebert
230 V models. GXT3 2U Models:
A true on-line UPS, Liebert GXT3 includes features Microprocessor-based control and
such as power factor correction, internal batteries,
monitoring package.
frequency conversion, unlimited external battery
Input power factor correction.
connectability and internal bypass capability. And all
this is housed in a smaller 2U size cabinet that cuts PWM inverter.
space requirements in half while providing up to Integral dynamic bypass.
3 kVA of true on-line power – batteries included. The Integral sealed, non-spillable,
UPS can also be used with external batteries hot-swappable battery.
for extended run times. Automatic and manual battery test feature
A Windows™ configuration program, included with with push button and indicator.
each unit allows the user to program a variety of Input and output noise suppression.
operating parameters. This capability allows you to USB port.
Liebert IntelliSlot® communications port.
On-line UPS Two-year no-hassle replacement warranty.
Bypass
DC - to - DC
Charger Converter
Battery
For more information, see pages 52 and 53. Optional Liebert MicroPOD 2U POD output distribution
and maintenance bypass module ensures continuous
uptime, even during UPS maintenance.
24
4
The internal battery packs are hot-swappable,
Liebert GXT3 On-line UPS: and user repleaceable. The unit also supports
High capacity, compact on-line UPS with flexible output voltage and power distribution.
Rack-Mount UPS
Emergency Power Off (EPO). Terminal
connections for a normally open or
normally closed emergency power off
switch.
Wider input voltage window minimizes
battery use — allows the UPS to support
the critical load without having to transfer
to battery, extending system availability
for when battery back-up is truly needed.
Liebert GXT3 UPS meets the need Other Product Features Of Internal automatic and manual bypass.
for higher power capacities in small
Liebert GXT3 5kVA-10kVA UPS Assures continuity of power to critical
spaces with these 5kVA-10kVA UPS
systems. These true on-line double Models Include: loads during system maintenance or in
conversion UPS systems feature User replaceable hot-swappable internal case of internal fault.
integrated maintenance bypass, as batteries. Provide four minutes of runtime Self-diagnostics. Automatically tests unit
well as optional extended battery at full load. electronics and batteries simplifying
runtime. Additional runtime with additional battery maintenance and troubleshooting.
Designed for use in either rack or cabinets. Liebert IntelliSlot Web Card provides SNMP
tower configurations, all units offer Built-in USB communications for use with and web-based monitoring and control of
the smallest available solutions for Liebert MultiLink™ Automated Shutdown UPS.
these power capacities — the 5 & Software. Allows you to monitor Standard two-year replacement warranty.
6kVA model at 120/208V output in 4U
communication between the UPS and a No-hassle warranty provides paid shipping
size, or the 8 & 10kVA unit 120/208V
output in a 6U package. A 6kVA 208V server, and ensures a graceful unattended both ways. Optional one-year and three
output 5U size model is also available. shutdown. year extensions available.
Built-in closure signals. Provides
To help meet the need for choosing a
notification to monitoring systems
single supplier for global applications,
220V, 230V and 240V 50/60 Hz of operating conditions including: on
models are offered with CE and C-tick battery, low battery, battery mode Liebert Power Monitoring Capabilities
markings. shutdown and any mode shutdown.
The operation of the UPS can be monitored using:
25
5
Liebert Nfinity® On-Line UPS:
4-20 kVA, 1-phase
operations from power problems A True On-Line System That Delivers Additional Features Of The
can be solved through the use of Continuous, Regenerated Sinewave Liebert Nfinity Power System:
Output Power Hot-swappable modules allow
large-scale UPS systems.
The Liebert Nfinity is a true on-line, the user to replace modules or upgrade
double-conversion UPS that provides 100% power the system without disturbing
A Powerful Defense conditioning, zero transfer time to battery, no connected equipment.
change in output voltage and better transient Continuous self-diagnostics
Against Uptime Threats
suppression than line-interactive units. detect and isolate faults to prevent
Liebert offers a full range of cascading system failures, as well as to
enterprise power protection Its unique frame design houses all of the modular
simplify maintenance and
system components, including 4 kVA power
solutions for any size facility from a troubleshooting.
modules, battery modules and system control
Patent pending intelligent
small computer room to the largest modules. By simply installing additional power
bypass technology provides seamless
data and communications centers. or battery modules, you can expand your current
transfers to and from
system, extend backup runtime or add redundancy.
the bypass source.
Liebert Enterprise UPS Intelligent power modules provide protection Wide input voltage window minimizes
Solutions Are Ideal For from all power aberrations, and a patent pending battery operation
electrical current-sharing technology provides to maximize battery life.
Large-Scale Data Centers.
equal distribution of power among all modules. Fully assembled and factory-tested,
Facility-Wide Networks.
The IntelliBattery™ modules utilize multiple simple to install and ready for use for a
Large-Scale Telecommunications
sensors to continuously monitor battery voltage, plug-and-play solution that is functional
Centers. current and temperature to determine and right out of the box.
Colocation Facilities. predict performance. Additional battery cabinets can
Internet Data Centers. The IntelliControl™ module works with the user be added for backup times up
Server Farms. interface to provide vital information about the to 72 hours.
Data Warehouses. condition of the power and battery modules. Two-year limited warranty for repair or
Network Management Centers. Liebert Power Monitoring Capabilities replacement with warranty extensions
also available.
Medical Imaging Equipment. ®
The operation of the Liebert Nfinity UPS can be
Test and Laboratory Facilities. monitored using:
Liebert IntelliSlot Web Card.
Industrial Process Control ®
Liebert
MultiLink Automated System Shutdown
Operations. Software.
Liebert
SiteScan® Web Centralized
Monitoring System.
26
4 For more information, see pages 52 and 53.
Slimline
Distribution
Cabinet Power
Module Battery
Cabinet
Enterprise UPS
The Liebert NX 10-30 kVA product family offers true
on-line, double conversion, three-phase UPS systems
that deliver complete, centralized power protection
for mission-critical systems. Available in 10, 15, 20 &
30 kVA capacities, these rugged units are designed to
meet the high availability power needs of a wide variety
of IT applications. Liebert NX 10-30 kVA UPS systems
combine advanced operating features, compact size and
Other Features Of Liebert NX 10-30 kVA UPS Models:
Increases growth flexibility by handling larger loads, and offers the
low cost of ownership in a range of sizes to suit room or
ability to parallel like-sized 20 and 30 kVA modules for increased
data center needs.
capacity and redundancy.
The “all-in-one” design of the Liebert NX 10-30 kVA Achieves higher availability by reducing the number of UPS units
UPS provides more protection security and efficiency required to power your room.
than using separate, smaller power units spread Reduces total cost of ownership through the use of longer life
throughout the facility. The Liebert NX delivers complete batteries and simplified preventive maintenance.
protection with a true on-line IGBT-based double Wider input voltage window and frequency tolerances contribute to
conversion design. The system’s advanced topology higher system availability by minimizing battery usage.
features a digital signal processor controlled IGBT Operates under a wide variety of conditions, handling 100% nonlinear
rectifier and IGBT inverter. loads with 3:1 crest factor, as well as 100% unbalanced loading.
IGBT-based power factor corrected rectifier enables the Liebert NX to
achieve its impressive THD and PF performance.
Advanced inverter control technology provides the highest output
power quality, ensuring very low output voltage THD and superior
waveform to protect connected loads.
Fully digital control technology provides a highly accurate, drift-proof
®
control compared to traditional analog electronics.
27
5
Liebert NX On-Line UPS:
40-200 kVA, 3-phase
Now There’s A Data Center UPS That Matches Your Growth Plans.
For high availability, high capacity applications, the Softscale™ technology provides flexibility to increase UPS capacity
transformerless Liebert NX 40-200kVA UPS systems offer true without changes in your infrastructure. From 40 up to 80kVA, 80
on-line, double conversion technology to protect and condition up to 120, and 160 to 200. You may also parallel UPS modules for
against the full range of power irregularities. Plus they do it with a capacity and redundancy.
level of flexibility not previously found in systems of this size.
The Liebert NX power core combined with the optional Liebert
A wider input voltage window and frequency tolerances help to NX BDC (Bypass Distribution Cabinet) lets you simplify power
minimize transfers to battery, reducing the number of charging distribution and voltage conversion. This combination provides
and discharging cycles. Availability is also enhanced with a triple packaged power distribution for today’s rack-based data centers
mode battery charger that enables fast battery recharge. Longer and IT facilities.
battery backup time may be achieved by paralleling additional
battery cabinets to the system.
28
Cutting-Edge Power Technology
Makes The Difference
Liebert NX UPS Systems Incorporate A Softscale™ technology, paralleling capabilities and Eco-mode™ all
Enterprise UPS
Number Of Other Exceptional Features: contribute to lower initial, incremental and operating costs.
High overload rating handles 125% for 10 minutes,
150% for one minute and a 1000% overload for 10 Liebert NX 40-200 kVA UPS Systems
milliseconds. Softscale Technology
Digital controls provide the fastest possible
Liebert NX 40-200 kVA UPS systems have Softscale technology
power management to enhance reliability, accuracy and
that provides flexibility to increase UPS capacity by 20 or 40kVA
efficiency.
Front access models available for installation along without changes in your infrastructure. Allows paralleling of
a wall. Front and rear access models available for unlike-sized models for capacity or redundancy. Designed for
installation in a row. optimized performance with the same high efficiency at 40%
Compact footprint requires less floor space, leaving you utilization as at 100% utilization.
with more room for other equipment.
Load Bus Synchronization standard. Paralleling Capabilities
Soft Switching technology increases efficiency Liebert NX 40-200 kVA systems allow you to parallel UPS
by up to 2% and saves energy. modules for capacity and redundancy, eliminating the
Integrated ground fault detection allows for effective batteries as a single point of failure because each UPS has its
transformer-less design while saving space and lowering own isolated battery. Liebert NX also features integrated dual
the unit weight. bus synchronization as a standard feature. This provides the
Parallel for redundancy or capacity. capability to synchronize the outputs of two independent UPS
Active input rectifier is generator modules when they are configured as a redundant system
and utility friendly.
feeding independent distribution paths.
Web card monitoring standard.
One year warranty. Eco-Mode High Efficiency Configuration
If selected, this operating mode switches the UPS to static
bypass during normal operation, increasing efficiency to up to
97% at full load. When power problems are detected the UPS
automatically switches back to double conversion mode.
Liebert NX BDC
The optional Liebert NX BDC provides flexibility in input and
output voltage for a variety of applications. This cabinet is
available in capacities to cover the Liebert NX UPS range of
40-200kVA. The monitoring panel matches the UPS unit. Power
and control cabling from this cabinet to the UPS is included,
enhancing ease of installation and availability. For ease of
installation and maintenance, the cabinet offers top or bottom
cable entry and models are available in front and rear access, or
front access only configurations.
Liebert NX Power Core
40-80 kVA
29
Liebert APM™ On-line UPS with FlexPower Technology:
15-90kVA, 3-phase
Liebert APM is a transformer-free, On-line double-conversion technology The cost-efficient Liebert APM provides
on-line UPS that allows quick and easy and internal redundancy combine to the reliability of an enterprise UPS, and
capacity increases with the addition of provide protection from the full range of the flexibility to adapt to increasing power
rack-mounted FlexPower™ core hardware power irregularities, offering the highest demands. This is a true, best-in-class solution
assemblies. The core assemblies allow availability. from the leader in power and cooling solutions
the UPS to expand for capacity or for computer rooms and data centers. Key
With efficiencies of up to 94% at typical
redundancy in 15kW increments within a features and benefits include:
load levels, Liebert APM offers one of the
single cabinet — 15kW to 45kW or 90kW. Up to 94% efficiency — High efficiency results
industry’s highest efficiency ratings. The
No additional floorspace is required. in lower energy consumption
UPS is even more efficient when sized in
FlexPower core assemblies may even be Front service access — for quick and easy
accordance with present system needs,
added without powering down connected installation
instead of purchasing a larger capacity
equipment. Transformer-free design — provides a
system to anticipate future requirements. smaller footprint and lower cost compared to
transformer-based systems
Matching bypass and distribution cabinet
— increase reliability and safety by switching
the protected load to bypass power for
maintenance and service
Matching battery cabinets — provides added
back-up capacity for extended runtimes
Distributed controls — each FlexPower core
assembly includes DSP controls, minimizing
possibility of single point of failure
Standalone static bypass module — features
independent controls in separate assembly to
provide higher reliability
Top or bottom cable entry — enables
installation on raised or non-raised floors
Large dot-matrix monitor with graphical
display — allows easy viewing and
comprehensive system information Includes
three Liebert
IntelliSlot ports for web-based
communications ability — Liebert IntelliSlot
card IS-485EXI allows communication with
Liebert SiteScan; Liebert IntelliSlot card
IS-WEBL allows communication with Liebert
Nform (90 day license included)
One-year warranty — provides full system
Liebert APM BDC, Liebert APM 90 kW FlexPower Core, coverage for one year
and Liebert APM External Battery Cabinet
30
Other Product Features Of
Enterprise UPS
Liebert APM UPS Include:
Internal bypass allows FlexPower assemblies to
be added or replaced without powering down
the connected equipment
45kW model includes internal batteries. More
runtime is available with optional external
battery cabinets
90kW units use optional external battery
cabinets for battery runtime
Conveniently positioned, easy-to-reach
power terminations simplify unit wiring and
installation
Enterprise-quality batteries in an external
battery cabinet provides backup time for 90kW
frame size, and additional runtime for 45kW
frame size
Withstand rating of 65kAIC ensures reliability
and safety under even the most extreme utility
conditions
Unity power factor design (kW=kVA) is
optimized for today’s high power factor loads
31
Liebert Npower™ On-Line UPS:
30-90 kVA, 3-phase
Liebert Npower is the next generation of large-scale UPS, utilizing Standard And Optional Features Of The
true double-conversion on-line technology to protect against the Liebert Npower UPS:
full spectrum of input and output power disturbances. Liebert 1+1 redundant configurations (for single-bus systems)
Npower’s all-digital ActiveStar™ controls are DSPbased and feature a that allow concurrent maintenance resulting in virtually
unique, patent-pending technology that allows it to make ultra-fast 100% availability of conditioned power
adjustments to changing loads, including subcycle pulse-width Load bus synchronization option for dual-bus systems
corrections to keep the output voltage waveform nearly flawless. The with two power feeds for added availability (for use with
Liebert Npower system is available in seven models ranging from 30 Liebert transfer switches or dual-input PDUs)
kVA up to 130 kVA.
Excellent efficiency powering non-linear, unbalanced and
The Liebert Npower is rugged enough to handle load branch faults, crest loads
input faults, 100% step loads, PDU startup inrush and motor-load Small footprint in a full-featured system
startup. Output voltage distortion (THD) typically measures less Exceptional overload and transient performance
than 2.5% — even under worst-case conditions. The combination of All DSP-controlled UPS
rugged inverter and continuous rated static switch gives the Liebert Easy-to-read screen and navigation menu on a large LCD
Npower exceptional overload capability. display
Superior battery algorithms used to minimize operation
of batteries and include self-test and temperature
compensated charging
32
Enterprise UPS
Great Value in a Mid-Range UPS High-Availability Configurations
The Liebert Npower gives you more UPS for about the same initial The Liebert Npower UPS can be used reliably as a single
cost as lesser products. Furthermore, the Npower will usually module and in various redundant configurations. The
cost significantly less over the lifetime of the product. The value Npower 1+1 Redundant option, described on pages 10-11
comes from several elements: exceptional protection, higher of this brochure, is a cost-effective parallel-redundant
efficiency, lower installation, maintenance and operating costs, system. Parallel redundancy improves maintainability and
smaller total system footprint and more standard features. fault tolerance, thereby enhancing system availability.
Higher Efficiency in Real-World Applications For the ultimate in high-availability systems, Npower can
be applied in various distributed-redundant (dual-bus)
Critical applications require a UPS to have an input filter (to
configurations, using our unique Load Bus Sync™ option.
reduce input current distortion) and an output isolation
Both Load Bus Sync and 1+1 Redundant configurations
transformer (to isolate your critical load), while powering
can be factory-installed or retrofitted to existing Npower
non-linear (high-crest-factor) loads at less than the rated capacity
installations.
of the UPS.
In this power range (up to 130 kVA), the only way to exceed
93.5% efficiency is to leave out something important. Some
competitors omit the output isolation transformer; others put
your critical load at risk with their single-conversion UPS products.
Only you can decide if the claimed savings justify the risk.
33
Liebert NXL—Stack Up Performance
Liebert NXL is
100% Load
designed to
Low & High Line Conditions handle all severe
conditions
40˚C / 104˚F Temperature
simultaneously
50% Clogged Air Filter and still support
100% load with
Fan Failure
no need for
Liebert NXL On-Line UPS: High Altitude1500 Meters derating.
Liebert NXL UPS Provides Reliable Power Other Liebert NXL Features Include:
Protection And Advanced Technology Matching battery and maintenance bypass cabinets for easy
For High Power Applications. configuration.
The industry’s most reliable power protection and Top or bottom cable entry.
advanced technology has been combined into a new Internal cabinet cable wiring simplifies installation.
generation of three-phase UPS systems for high power Ship-ahead I/O section can be installed before UPS installation.
Liebert ActiveStar® Digital Signal Processor (DSP) controls—no
applications — the Liebert NXL from Emerson Network
potentiometers.
Power.
Redundant components—fans, power supplies, and
Available in 250, 300, 400, 500, 625 and 750 kVA communications cards.
single module models and multi-module systems, the Provides superior handling of present and future computer loads,
transformer-based Liebert NXL provides excellent dynamic up to 0.95 leading power factor without derating.
Color touch screen controls improve user interface and reduce risk
performance, with the ability to handle virtually any input
of human error.
condition while still providing computer grade output
Excellent dynamic performance and fault tolerance.
to critical loads.
Generator and utility friendly with low current distortion.
The leader in large UPS system installations, Emerson Front access for installation and service.
offers complete and unequalled support, including Compact cabinets require less floor space.
engineering consultation, the largest and most widespread Inter-cabinet cabling requires less hard wiring.
factory-trained service organization, and the industry’s Built-in battery cabinet breaker isolates string for ease of service.
Energy efficient operation, with up to 94% operating efficiency.
largest and most advanced production and witness test
First large UPS to be tested and UL Listed to UL1778 Fourth Edition,
facility.
which requires testing of every specification.
Liebert NXL UPS Battery Cabinet Power Core Maintenance Bypass Cabinet
34
AC Input
Liebert Power Monitoring Capabilities AC Input
Optimized Performance Liebert NXL Single Module System One-Line (250-750 kVA)
Enterprise UPS
Intelligent Eco-Mode™ — Liebert NXL offers up to 97%
full load efficiency during user-selectable Intelligent Bypass
AC Input
Bypass Static Switch
Eco-Mode™ operation. The always-on inverter ensures AC Input Static Switch
Rectifier Inverter
Rectifier Inverter
high availability and seamlessly assumes the load in case
Rectifier AC Output
of a utility power disturbance. AC Input
Rectifier to Load
AC Output
AC Input to Load
Intelligent Paralleling™ — Modules paralleled with
a system control cabinet (N+1 configuration) may be Battery
Battery
customer selected to use Intelligent Paralleling, which
increases efficiency by turning off redundant modules.
Off time is equally distributed between all modules. Liebert NXL 1+N Multi-Module System One-Line (250-750kVA)
Distributed Static Switch
Configuration Options AC Input
AC Input
Single-Module Configuration (250-750kVA models) Rectifier Bypass Rectifier Bypass
AC Input
Rectifier AC Input
Bypass AC Input
Rectifier AC Input
Bypass
Single-module systems provide a basic protection AC Input AC Input AC Input AC Input
Paralleling of Multi Module units, without built-in static Liebert NXL N+1 Multi-Module System One-Line (500-750 kVA)
Centralized Static Switch
switch
AC Input
equires System Control Cabinet with centralized
R
static switch Rectifier Rectifier Bypass
AC Input
System Control Cabinet can be easily integrated into AC Input AC Input
35
Liebert Series 610 On-Line 610 UPS:
225-1000 kVA, 3-phase
Technology By Liebert.
36
Liebert NXL, Liebert Series 610
System Control Cabinet - SCC
When paralleling two or more units, a system control cabinet Each SCC includes:
Enterprise UPS
monitors the output of the UPS’s and assures that all of Microprocessor-based monitoring with backlit LCD
display, controls.
the outputs are synchronized. The System Control Cabinet
Momentary-duty static switch.
also contains a static bypass switch which assists in the Continuous duty static switch options
maintenance of the system. with custom switchgear.
Automatic system isolation and bypass breakers.
System Control Cabinets are integrated into
Automatic equalize charge timer.
the switchgear of your choice.
Interface for a remote power off.
Centralized monitoring controls allow Liebert SiteScan® Web interface.
for greater visibility into the system. Alarm status contacts.
Liebert SCC’s 610 contains a static bypass switch RS-232 port.
with manually operated disconnects and two Visual/audible alarms.
motor operated system circuit breakers.
Standard and custom power distribution switchgear
systems are available for use in Tier 1 through Tier 4 UPS
system configurations.
37
Liebert Trinergy, Multi-Modal On-line UPS:
200 kVA - 3.2 MVA, 3-phase
38
Three Dimensional Modularity User Interface
Enterprise UPS
With three dimensions of modularity — Vertical, Horizontal and Orthogonal
— Liebert Trinergy UPS allows businesses to expand their power protection
needs at the same pace as their evolving load requirements by simply
adding additional power modules. Modules can be added at anytime during
the lifecycle of the UPS, allowing it to reach up to 3.2MVAv .
39
Liebert FDC
Rack Power Distribution
40
Liebert RDC Remote Distribution Cabinet
Unlike standard Liebert Precision Power Centers (PPCs), the RDC has no
internal isolation transformer and requires 4-wire-plus-ground input from
a PPC or other transformer. By separating the PPC transformer from the
panelboard function, Liebert was able to create an extremely compact
package that fits the area of a standard 24” x 24” raised-floor tile.
41
Liebert FPC Rack-sized Power Conditioning
and Distribution Cabinet
Optimized For Row-based Applications. Other Standard Features Of The Liebert FPC:
Computer-grade grounding.
The Liebert FPC power conditioning and distribution cabinet provides Fully compatible with the non-linear loads.
higher quality, more flexible power distribution for high-density
Main input breaker with shunt trip.
data centers. It is engineered to combine the convenience and cost
Double-shielded TP1 listed isolation transformer.*
savings of a pre-packaged, factory-tested unit with the flexibility of a
custom-tailored power system. This self-contained system provides One or more individually enclosed 42-pole output
power isolation, power distribution, computer-grade grounding and panelboards.
power monitoring. Built-in metering and alarm annunciation with
communication to Liebert centralized monitoring.
Ranging in capacity from 15kVA up to 300kVA, the Liebert FPC comes Compact single cabinet conserves valuable floor space.
in a 19” rack and 47” wide rack, the size of two 19” racks, and is Single input cable connection reduces installation time
designed to fit at the end of, or within, a row of racks, as well as in a and cost.
stand-alone configuration. Full front and rear access.
Can be easily relocated to protect your investment.
The packaged system approach of the Liebert FPC is convenient
UL and ULc Listed as a complete system.
and space-saving, reducing installation time and cost compared to a
conventional approach using multiple interconnected components. *Energy Policy Act of 2005 requires that all “distribution transformers”
and all “low-voltage dry-type distribution transformer” manufacturers
produce only TP-1 units as of January 1, 2007. TP-1 transformers have
a higher efficiency than standard isolation transformers, and are
optimized to have the highest efficiency at 35% load.
42
Liebert PPC Packaged Power Conditioning
and Distribution
Easy installation, with single input cable connection The operation of the Liebert Precision Power
and application matched connections to the load. Center and Liebert FPC can be monitored using:
Expandable with add-on panelboards Liebert Nform™ Monitoring System.
Liebert
SiteScan® Web Centralized
and flexible cabling.
Monitoring System.
Flexibility to protect your investment by allowing
Third-Party Monitoring Systems.
the unit to be easily relocated.
UL and CSA Listed as a complete system. For more information, see pages 52 and 53.
43
Easy-To-Use Color
Touch-Screen Interface
The controls of the Liebert STS2 are
intuitive and simple. The pop-up menus
are easy to understand and provide a
wealth of operational and diagnostic
information.
44
Liebert STS2/PDU Static Transfer Switch/
Power Distribution Unit
Combines Power Distribution And Automatic Switching. Features Of The Liebert STS2/PDU Include:
45
Liebert Power Systems Test Center
The Liebert Power Test Center for large Test Capacity and Performance of Liebert Power Solutions
UPS systems is a state-of-the-art test The Liebert Power Test Center for large UPS systems consists of multiple test
facility designed to provide customers with stations in each of seven test bays. Testing is customized based on the complexity,
pre-installation testing of the performance, size and number of UPS components in the configuration, but always includes
interoperability, and efficiency of Liebert analysis of every module as well as the entire system. Module and system tests
power modules and systems under a variety include:
of conditions. Located in Delaware, Ohio, the
Steady-state — 0% to 100% plus overload, unbalanced loading; non-linear loading
41,000 square-foot facility, including a 2,600
Dynamic — 0% to 100% step loads plus overload, unbalanced loading; non-linear
square-foot customer observation suite, is loading
the largest and most comprehensive in the Overload and faults — (>100%, 125%, 150%)
industry. Plus other customer-specified special test requirements.
Testing includes individual UPS modules as Testing on large Liebert UPS systems, may include UPS power modules, input and
well as the complete power system—including output switchgear, power distribution units, static transfer switches, and battery
large UPS units such as the Liebert NXL UPS cabinets.
and associated switchgear and ancillary
Test results certify the input and output, AC and DC characteristics of the system.
products—and is essential to the smooth,
Performance comparisons against specifications include, but are not limited to:
rapid installation and commissioning of large
power systems. Customers leave the Liebert Voltage and waveform
Voltage regulation
Power Test Center with documented test
Voltage and current harmonics
results and confidence that their complex
Frequency
power system will operate seamlessly and in
Current and waveform
accordance with business-critical availability
I/O power factor
requirements.
Efficiency based on kW in and out
System switching, control and monitoring functionality
46
Enterprise UPS
Factory Witness Testing: View the Entire Testing Process Benefits of Power System Testing:
Factory Witness testing for large UPS systems is usually conducted over a Provides complete pre-installation testing of large
period of multiple days. During testing, customers and consulting engineers UPS systems and associated support equipment.
Tests the performance, interoperability and
may oversee the entire process from the Power Test Center observation suite
efficiency of critical power systems.
that overlooks the test bays or in the specific test bay itself. Multiple LCD
Assures rapid installation and commissioning of
panels offer easy access to real-time test data, including waveforms, testing
large UPS power systems.
procedures and results. Once testing is completed, a report of the results is Confirms the functionality of all subsystems.
provided. Allows customers to document performance of
multi-module UPS systems prior to installation.
The Liebert Power Test Center features seven test bays, each containing
Optimizes the testing process with the use of the
multiple test stations, where module and complete system analysis is
latest agency standards.
conducted in full view of the customer.
47
Power Quality Solutions High Quality Surge Protection
For applications requiring protection from electrical line problems without the These Products Include:
need for back-up capability, Liebert manufactures a full line of surge suppression
and power conditioning equipment.
High Exposure Systems
The Best Possible Power
Liebert’s wide range of Surge Protective Devices, (SPDs) have numerous Liebert SI Series (Interceptor II)—Built to
applications throughout a facility, including protection against transients provide the highest level of surge current
that are generated by other equipment within the building. Our power capacity, with the lowest clamping voltages.
Along with true NEMA 4 assembly suitable for
conditioning systems shield critical loads from external disturbances,
outdoor use.
particularly those coming through the utility power line.
Liebert Power Protection Solutions Are Ideal For: Liebert LM Series—Offers continuous
Computer Centers. Network Management Centers. protection from damaging transients and
electrical line noise. Surge suppression levels
Facility-Wide Networks. Medical Imaging Equipment. range from 120 kA to 500 kA per phase.
Telecommunications Centers. Test And Laboratory Facilities.
Colocation Facilities. Industrial Operations.
Internet Data Centers.
Liebert ACV Series (AccuVar)—A full line
of multi-phase, multi-mode distribution
panel-mounted surge suppression devices.
48
Emerson Network Power manufactures the industry’s Installing protection at the electrical service entrance,
widest range of Surge Protective Devices (SPDs). These distribution points, branch panelboards and on specific
SPDs are ideal for small facilities, large equipment sensitive loads or equipment throughout your facility
rooms or entire buildings, plus a wide range of power, is the best way to prevent damage and eliminate
control and data line applications. Each surge protection associated downtime to sensitive microprocessor-based
product features the rugged reliability that has been the electronics.
Liebert trademark for more than 40 years.
49
Powerful Solutions
For Critical Data And Telecom Applications
From major switching and data centers to remote shelters and computer
rooms, Emerson Network Power -48V DC power systems have the features and
proven performance to match your network application needs.
Visit: EmersonNetworkPower.com/DCPower
50
50
As the next step in the evolution of the
NetSure® DC Power platform, eSure™ high-efficiency rectifiers
from Emerson offer superior performance and uncompromised
reliability, delivering efficiency levels near 97%.
eSure™ technology delivers Efficiency Without Compromise™.
Large DC Power Systems Small DC Power Systems
DC Power Systems
208/480VAC 3-Phase Input 120 / 240VAC Single Phase Input
Power systems for data center and central office Highly reliable, uninterruptible and cost-effective power systems
applications, including wireline and wireless switching, for small data or telecom installations.
transmission, data routing and large telecom hotels.
NetSure® 502
The NetSure® 502 is a flexible system
capable of providing DC power through
the use of 2000W standard or high-
efficiency eSure™ rectifiers, an SCU+
controller, and a variety of outputdistribution options.
51
Power System Monitoring:
The Key To Continuous Operation
What You Don’t Know Can Hurt You. How Deep Does Your Monitoring
A small problem in a critical facility can quickly Need To Be?
escalate into a disaster—knowing what is happening Monitoring can range from a automated shutdown
with your power equipment, so you can keep that software that provides basic operating information
protective “envelope” at peak operating efficiency, from a single UPS unit, all the way to full-scale
is vital to system reliability. monitoring and control of a critical facility including
trending and data analysis.
Different People Need To Know
Different Things. Your requirements will vary according to the specificity
Liebert offers you more monitoring solutions than of the information you need. You may require no more
anyone else because getting the right information than a local readout of a unit’s operating status. Or you
about your power equipment to the right people, may need the ability to control its operation and
with the right level of urgency, is so important to receive alarms.
system availability.
These information requirements may also go beyond
We do this by allowing you to receive and use basic monitoring and control. You may need the ability
information from your Liebert power equipment’s to analyze performance data in order to pinpoint
microprocessor controls–no matter where it is located trouble spots so that the same problems don’t
or what communications protocol, operating platform happen again and again.
or building management system is being used.
In-band, out-of-band and web-based monitoring are
all available. From enterprise monitoring systems
to individual pieces of communications hardware,
you will know the exact problem so that you can
implement the right solution.
52
Maximizing Your Investment Through System Monitoring
Liebert Nform
Liebert IntelliSlot Web
53
Liebert Services
Complete Start-Up And Preventive Maintenance Services
Peace of mind. It’s confidence you’ve done everything possible Confident Customers. Satisfied Customers.
to assure system uptime. It’s confidence the power systems You know them. They’re confident because they
know their systems will be available when they
you rely on are operating at peak performance. It’s confidence
need them. So, they’re satisfied customers—and,
you’ve selected the best partner available to bring you back they’re probably ours. 99% of our customers are
online in the event of unexpected downtime. satisfied with the service we provide. In fact, 96%
of them would recommend us to someone else
Complete confidence. When it comes to selecting a (source: MRSI).
service organization to maintain your critical power
systems, you can only have complete confidence that Proprietary Tools Deliver Uptime
Emerson Network Power Liebert Services can deliver: Ensuring peak operating performance of your
equipment comes down to having knowledgeable
Real uptime assurance. We have the proprietary Field Technicians in your facility with the most
tools, industry knowledge and robust service current tools available to do the job. Only Emerson
infrastructure to deliver real assurance that your Network Power Field Technicians have access to
systems will be available when you need them. the proprietary tools needed to ensure system
uptime—firmware upgrades, factory engineering
Efficient downtime recovery. After all, if downtime
specifications, access to Liebert product and
strikes, you need a partner that can get you back
application engineers and R&D. No one else can
online quickly with intelligent answers, rapid service
bring this to your organization.
response and parts where and when you need them.
60x Increase in MTBF Regular OEM preventive maintenance increases the mean
51x time between failures (MTBF).
50x
For instance, the mean time between failures for a system
Increase in 40x 37x that receives 1 annual PM is 10 times greater than a system
Mean Time that receives 0 PMs.
Between
30x
Failures1 By contrast, a system that receives 4 annual PMs, as
23x
opposed to 0 PMs, increases its duration between failures
20x
by 51 times.
10x
10x 1
Data is based on Mean Time Between Failure analysis for
1x three phase UPS systems (≥ 100kVA) with an Emerson
Network Power service agreement between 2002-2007.
0 1 2 3 4
Number of Annual Preventive Maintenance Visits
54
Servicing All Your Critical Power Equipment
55
Ensuring The High Availability Of
Mission-Critical Data And Applications.
Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader Emerson Network Power
Liebert Corporation
in enabling Business- Critical Continuity™ from grid to chip for telecommunication World Headquarters
1050 Dearborn Drive
networks, data centers, health care and industrial facilities. Emerson Network Power P.O. Box 29186
provides innovative solutions and expertise in areas including AC and DC power and Columbus, Ohio 43229
United States Of America
precision cooling systems, embedded computing and power, integrated racks and 800 877 9222 Phone (U.S. & Canada Only)
614 888 0246 Phone (Outside U.S.)
enclosures, power switching and controls, monitoring, and connectivity. All solutions 614 841 6022 FAX
are supported globally by local Emerson Network Power service technicians. Liebert Emerson Network Power
AC power, precision cooling and monitoring products and services from Emerson European Headquarters
Via Leonardo Da Vinci 8
Network Power deliver Efficiency Without Compromise™ by helping customers Zona Industriale Tognana
35028 Piove Di Sacco (PD)
optimize their data center infrastructure to reduce costs and deliver high availability. Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.
©2011 Emerson Electric Co.