Power Protection 70100 R06 11

Download as pdf or txt
Download as pdf or txt
You are on page 1of 56

AC Power

For Business-Critical Continuity™

Liebert ® Power Solutions


IT System Protection That Grows With Your Needs
A Comprehensive Power Solution—We’re The Only One Who Has It

The Widest Range Of Products Gives You An Infinite Range Of Solutions

It All Starts With Rack Systems ­­Critical Electrical Distribution


Liebert and Knurr brand computer rack systems offer all Emerson Network Power offers a range of power distribution
the advanced features and innovative flexibility required to systems designed to efficiently deliver conditioned power to
accommodate today’s dense and complex IT systems and your critical equipment. These products include high-reliability
network gear. distribution systems, starting with rack power distribution
systems, specially designed for computer and communications
Knurr racks simplify equipment installation, improve cable
applications, as well as transfer switches offering ultra-fast
management and increase visibility and control of equipment
transfer between two independent AC power sources to
inside the rack.
provide virtually uninterrupted power to sensitive electronic
Liebert enclosures integrate power and cooling to provide equipment.
a complete rack-based support system. Liebert pioneered
Power Quality Protection
this approach with the Little Glass House and today provides
For applications requiring protection from electrical line
enclosures, such as the Liebert MCR and Liebert XDF, which
disturbances without the need for back-up capability, Emerson
protect sensitive electronics in almost any environment.
manufactures a full line of power conditioning equipment. It
UPS Systems includes a wide variety of transient voltage surge suppression
Emerson Network Power offers Liebert brand UPS in all (TVSS) solutions ranging from high-quality surge suppressors
three major uninterruptible power supply (UPS) system for use with PCs, workstations and other peripherals to
configurations: facility-wide systems with sophisticated active tracking
capability.
Stand-by UPS—Passes utility power straight through to
the protected load with a 2-6 ms break in power when DC Power Systems For Communications Applications
transferring to battery back-up. From major switching centers to remote shelters, Emerson
DC power systems offer performance and features to match
Line-Interactive UPS—Provides power conditioning with
virtually every telecommunications equipment application.
a 2-6 ms break in power when transferring to battery
The line includes a variety of system capacities ranging from
back-up.
small systems at less than 3 kW up to large systems rated at
On-Line (Double Conversion) UPS—Delivers continuous, over 60 kW. The product offering also includes distribution
high-quality AC power to equipment with no break when bays, enclosures and network management products such as
transferring to battery. Protects equipment from virtually controllers, monitors and supervisory software to control and
all power disturbances due to blackouts, brownouts, sags, maintain energy equipment in a telecommunications network.
surges or noise interference.
Power System Monitoring
Emerson Network Power offers UPS systems in the industry’s Liebert brand power communications software and hardware
widest range of sizes including desktop, rack-mount and provides multiple levels of monitoring and control. Capabilities
enterprise systems for full facility power. range from automated shutdown software to facility-wide
centralized systems that provide a full range of monitoring,
control and analysis.

2
There Is A Liebert Power Solution

Desktops / Peripherals
To Meet Every Need

Emergency Shelters
Computer Rooms

Network Closets

Telecom / CATV
Labs & Testing

Point-Of-Sale
Data Centers

Production
CONTENTS

1 Racks, Integrated Cabinets, Modular Power Distribution


10 Knurr Rack Enclosure System
11 Liebert MCR Mini Computer Room Enclosure
12-13 Smart Solutions
14-15 Liebert MB Modular Busway

2 Rack PDU
16 Liebert MPX Adaptive Rack PDU
17 Liebert MPH Managed Rack PDU
18 Liebert MPX And Liebert MPH
19 Knurr DI-STRIP, Basic Rack PDU

3 Desktop UPS For One-On-One Applications


20 Liebert PSP Stand-by UPS: 350-650 VA
21 Liebert PSA Line-Interactice UPS 500 – 1500 VA

4 Rack-Mount UPS For Distributed Network Applications


22-23 Liebert PSI And PSI-XR Line-interactive UPS: 750-3000 VA
24 Liebert GXT3 On-line UPS: 500-3000 VA
25 Liebert GXT3 On-line UPS: 5 - 10 kVA

5 Enterprise UPS For Computer Room And Data Center Applications


26 Liebert Nfinity On-line UPS: 4-20 kVA
27 Liebert NX On-line UPS: 10-30 kVA
28-29 Liebert NX On-line UPS: 40-200 kVA
30-31 Liebert APM On-line UPS: 15-90 kVA
32-33 Liebert Npower On-line UPS: 30-130 kVA
34-35 Liebert NXL On-Line UPS: 250-750 kVA
36-37 Liebert Series 610 On-line UPS: 225-1000 kVA
38-39 Liebert Trinergy On-line UPS: 400kVA - 3.2MVA

6 Power Distribution Systems For Critical Protection Applications


40 Liebert FDC Power Distribution Cabinet
41 Liebert RDC Remote Distribution Cabinet (RDC)
42 Liebert FPC Power Conditioning & Distribution Cabinet
43 Liebert PPC Conditioning And Distribution Cabinet
44 Liebert STS2 Static Transfer Switch2 (STS2)
45 Liebert STS2/PDU Static Transfer Switch/Power Distribution Unit
46-47 Liebert Power Systems Test Center

7 Surge Protection And Power Conditioning Systems


48-49 High Exposure Systems, Low & Medium Exposure Systems,
Home & Office Protection, and Data/Signal Line Protection

8 DC Power Systems For Telecommunications Applications


50-51 Small Power, Medium Power, Large Power, Inverter Systems, Batteries & Accessories

9 Monitoring And Control


52-53 Liebert IntelliSlot, Liebert Nform & Liebert SiteScan Web
54-55 Liebert Services

3
Trouble Is Coming Down The Power Line And You Must Be Prepared

Every operation in your business depends upon the instant, You Face Many Challenges In The
around-the-clock availability of computers, servers and other Pursuit Of Productivity
electronic systems. If they aren’t working, neither is your company.
Is There Really A Problem?
Unfortunately, every piece of this equipment your company “My computer can ride right through a short blip
possesses is subject to the whims of the electricity that powers it. in the power—why do I need anything else?”

The first step in taking control of this situation is to understand the threats
to your system reliability—and exactly what you can do about them.
Different Needs Require Different Power
Protection Configurations
“Should I have a small UPS for each workstation
or have everything on one large system.
Which is best for my facility?”

A Lot Can Happen Between Your UPS


And The Equipment It Is Protecting
“We have dozens of pieces of networking equipment.
How can I make sure that each one is getting exactly
the power it needs?”

Every Wire Carries The Potential


For Trouble
“An electrical surge came in through an outside
phone line and knocked out our entire communications
system. Is this going to happen again?”

A Single Source Of Power Simply


May Not Be Enough
“Adding a second power feed would certainly enhance
our availability picture—but who can we talk to about
getting it done right?”

You Need Efficiency... Without


Compromising Availability
“Budgets are tight, so I have to consider equipment costs
at all lifecycle phases — first cost, operation, and service.
How do I maximize efficiency and ensure reliability?”
4
But There Are Real Solutions

You Need Protection From All Power Problems


An outage is just the problem you can see. There are many other more frequent power fluctuations—surges, spikes, sags—
that you don’t see. These are the conditions that cause the “unexplained” lock-ups and other potentially damaging results.
Protecting critical network and computing systems requires the expertise of someone who understands all the risks you
face from poor power quality.

Centralized Vs. Distributed UPS Protection


Liebert has the breadth of products that allows you to implement either a centralized or a one-on-one distributed
power protection strategy depending on your requirements. Whatever configuration you choose, you can count
on Liebert to make it the best it can be. Benefits, such as increased system security, more efficient maintenance and
improved reliability, may make a centralized strategy a better choice for larger operations.

Proper Power Depends On Proper Distribution


In network applications, there may be hundreds of different loads with various voltage requirements, a mix of AC and DC
power, plus any number of other electrical specifications. This calls for a distribution system that is designed to maintain the
highest levels of reliability and quality between the source of conditioned power and the protected equipment.

Power Conditioning And Surge Protection Throughout The Facility


Power conditioning and surge suppression systems are key to maintaining power quality in critical facilities. Raw utility
power is often far too “dirty” for sensitive systems, resulting in lost or garbled data, unexpected software glitches
or shutdowns, even hardware damage. The IEEE recommended practice is to install transient voltage surge suppression
(TVSS) protection on every electrical conductor that penetrates a facility shell, including power lines, telephone and
other communications links.

Maximum Reliability Demands Dual Power Sources


If your needs require the highest level of system availability, Liebert has the knowledge and products to implement a
dual-power strategy throughout your enterprise. UPS, transfer switching, power distribution and other equipment
are all brought together to create the ultimate in reliability.

Optimize Data Center Infrastructure With Efficient, High Availability Technologies


Emerson Network Power delivers Efficiency Without Compromise® — technologies and products that optimize data
center infrastructure to reduce design, management and energy costs while maintaining high availability and flexibility.
Our industry-leading technologies optimize efficiencies and reliability in identified areas of opportunity: Infrastructure
Management; Eco Availability; Flex Capacity; and High Density.
5
Where Do You Need Mission-Critical
Power Protection Technology?
Computer
Systems
Health Care
Retail
Distribution
Biotechnology
Industry Government Industrial

We have efficient, high availability Liebert has identified ten distinct zones or areas of application, found
power solutions for any of the within many business operations, which have a requirement for
mission-critical power technology. While these zones have similarities
applications that are part of your
in the importance of their essential functions, they also have
mission-critical business operations.
different needs for infrastructure protection—all of which can be met
by Liebert solutions.

Large Data Centers—High Production—Smart factories Emergency Shelters—Emergency


availability data and network backed by a complex electronic operations centers, 911 response
applications are the heart of your network, from computer-con- emergency dispatch, police and fire
enterprise with blade servers and trolled machinery and processes facilities, medical facilities, public
high-density racks that demand to electronic sensors, business works operations and more.
increased power protection. systems and utility equipment.
Desktop/Peripherals—Home and
Small To Mid-Size Data Centers— Laboratories and Testing— small office computers, modems,
Smaller sized network and Sensitive computers and network components and other
computer facilities, but equally equipment used for diagnosing electronic equipment that is vital
essential to your operations. patients, analyzing data, to business operations.
performing critical tests, and
Network Closets—Housing Point-of-Sale—Today’s cash
operating electronic tools and
routers, switches, modems, cabling registers and store-level computer
lab instruments.
devices and numerous other networks not only handle sales
communications components. Telecom/CATV—Anything from transactions, they also collect
indoor and outdoor spaces hosting and transmit vital customer and
Network Operations Centers—
cable, DSL and fiber optics to inventory data required to make
As networks expand and grow
remote cell sites and enclosures. informed supply chain decisions.
more complex, you need reliable
and timely access to
mission-critical infrastructure
monitoring information long before
problems arise.

6
Telecom Wireline/Wireless Sites
Liebert can provide a reliable flow
UPStation
GXT

AC
INPUT
BATTERY
UPS
ON
BYPASS

UPStation
GXT

AC
INPUT
BATTERY
UPS
ON
BYPASS

of both AC and DC power for


telephone switching systems and
other communications equipment.

UPStation
GXT

AC
INPUT
BATTERY
UPS
ONBYPASS

UPStation
GXT

AC
INPUT
BATTERY
UPS
ONBYPASS

Emergency Shelters
High-reliability Liebert UPS systems and DC
power equipment are critical to maintaining
operations in telecommunications shelters
and other unmanned structures. Network Operations
Centers
With many mission-critical
computing systems located
right in the office space,
there is a need for UPS
protection that can be
placed nearby. Liebert offers
a number of power systems
that are especially designed
for use in business and office
environments.

Network Closets
These densely-packed equipment UPStation

AC

UPStation

AC
GXT

INPUT

GXT

+
BATTERY

INPUT
UPS

BATTERY
ONBYPASS

bays, housing servers or other


UPS
ONBYPASS

essential communications devices


require UPS back-up plus distribution
to get uninterrupted, conditioned
power to each and every component
in the rack.
Small to mid-size
Data Center
UPStation

AC
GXT

INPUT
BATTERY
UPS
ON
BYPASS

Liebert offers the full range


UPStation

AC
GXT

INPUT
BATTERY
UPS
ON
BYPASS of UPS, distribution systems
and other power protection
equipment that can adapt
to data center growth
requirements.

Production
Liebert UPS, surge protection and power
distribution are all key to maintaining the
proper operation of process control and
Data Center UPStation

AC

UPStation

AC
GXT

INPUT

GXT

INPUT
BATTERY

BATTERY
UPS

UPS
ON

ON
BYPASS

BYPASS

other manufacturing systems that utilize


Liebert offers the full
UPStation
GXT

AC
INPUT
BATTERY
UPS
ON
BYPASS

microprocessor and computer control.


range of UPS, distribution
systems and other power
protection equipment
UPStation
GXT

AC
INPUT
BATTERY
UPS
ON
BYPASS

UPStation
GXT

AC
INPUT
BATTERY
UPS
ON
BYPASS

UPStation
GXT

AC
INPUT
BATTERY
UPS
ON
BYPASS

to meet the needs of the


UPStation
GXT

AC
INPUT
BATTERY
UPS
ON
BYPASS

largest data centers and


networking facilities.

Mechanical Rooms
Liebert power protection and conditioning
systems can greatly improve the operation
of electrical switchgear and motor control
centers vital to numerous functions
throughout an industrial facility.

7
Efficiency Without Compromise ®

Design, Operation, Management And Planning


Optimized For Efficiency And High Availability.

Expert Advice
INFRASTRUCTURE  ritical infrastructure expertise enables highly
C
MANAGEMENT efficient and effective designs.

Improving performance of  ssessments identify power and cooling


A
the IT infrastructure and improvements that provide immediate and
ongoing cost savings.
environment

Uninterruptible Power
Areas of Opportunity

Liebert NX and Liebert NXL deliver highly reliable


ECO AVAILABILITY on-line UPS protection while providing efficiencies
Balancing high levels of of up to 94% at part load and up to 97% at full load.
When operating on Eco-Mode, the always-on
availability and efficiency
inverter ensures high availability and seamlessly
assumes the load in case of a utility power
disturbance.

Variable Air Flow


L iebert CW with VSD reduces energy consumption
FLEX CAPACITY by 50% at 80% speed, saving up to$5,000/year/
Adapting to IT changes for unit and providing a <2 year payback.
continuous optimization L iebert CW with EC Fans reduces energy
and design flexibility consumption by up to 30% at full speed and
65% at 80% speed.

High Density Cooling


HIGH DENSITY L iebert XD can cool densities of >30 kW/Rack
and is up to 30% more efficient than traditional
Delivering architectures
cooling systems.
from 10-60 kW/Rack to
minimize space and cost L iebert XD uses pumped refrigerant and
dewpoint control to prevent condensation.

8
Design &
Deployment
Shorten Time
Minimize Space

Management
Operation
& Planning
Improve Performance Increase Availability
Increase Control Reduce Energy

Management Tools & Technologies Integration & Operation Services With more ways
 rack, row and room sensor networks provide
IT, Implementation and commissioning services
to optimize
management and control of temp, humidity, ensure rapid deployment. data center
pressure, power, water detection, capacity,
and battery health.
E nterprise remote monitoring enables proactive
management.
infrastructure to
 entralized real-time monitoring reduces
C Standards-based interface with Building Management
reduce design,
downtime and management. System bridges IT and facility management. management
and energy
costs while
Economization Critical Services
maintaining
F luid economizers enable “free cooling”
while controlling temperature, humidity, and
 reventive maintenance optimizes
P
the lifetime value of equipment.
high availability
preventing contamination.
F acility Power Audits maximize efficiency
and flexibility,
L iebert Glycool safely uses outside temperatures
to reduce cooling system compressor runtime,
and availability. Emerson Network
saving up to 25% of energy cost.

Battery monitoring and service maximizes
performance, life, and availability.
Power delivers...
Efficiency
Variable Capacity Intelligent Control
Without

Liebert DS is the only data center cooling L iebert iCOM with predictive control and
Compromise
system to use variable capacity Digital Scroll teamwork saves up to 7% energy consumption
compressors. over traditional controls.

 ariable capacity compressors reduce energy


V  anages “zones” including non-homogeneous
M
consumption by up to 30% on an air cooled heat loads, contained areas, and localized
system, saving up to $5,000/yr/unit. high density areas for optimized cooling
performance.

Intelligent Aisle Containment Power Architecture


 martAisle by Emerson Network Power
S 
Liebert and Knurr rack PDUs are available
eliminates temperature stratification and in configurations up to 60 amp, with
excess airflow at IT equipment source. an industry-leading standard operating
temperature of up to 131°F, for reliable
E asily retrofitted with existing cooling
support of high density racks.
infrastructure for up to 30% efficiency and
up to 25% capacity improvements.  tandard TP-1 transformers in PDUs provide
S
up to 98.7% efficiency.

9
Knurr Racks And Cabinets

The Right Place To Ready-To-Deploy Rack And


Enclosure Solutions.
Protect Network Knurr DCM racks provide the
Equipment convenience of robust 19” racks
with high-end features and
The Knurr DCM enclosure is a new standardized options to provide
fast customization for individual 83% Open Area Roof Pre-Drilled Spring Nut In
platform from Emerson Network For Improved For XDV T-Slot
site needs. The racks are designed Airflow, Highest In Accepts XDV Allows Component
Power that lets facility managers for optimized air flow and The Industry With No Need For Mounting
and IT professionals manage server, maximized useful mounting space. Drilling Anywhere In
Cabinet Frame
switch, and termination applications.
Tool-Less Shelf
Knurr DCM was designed as the Mounts In
base element for all of Emerson Square Holes
Network Power’s row and rack On 19” Rails In
solutions and is compatible with all Seconds
Liebert Power and Liebert Precision
Cooling products. The Knurr DCM
offers all the advanced features and
Tool-Less
innovative flexibility required to
Cable
accommodate today’s dense and Management
complex IT systems and network on Frame
gear. Insert And 1/4
Turn, Installs In
Knurr DCM simplifies equipment A Second
installation, improves cable
management, and increases Doors Open to
visibility and control of equipment 135˚
inside the rack. The rack easily Allows Easy
Access To
integrates power, cooling, and
Cabinet,
monitoring systems to provide a Without
complete support system. Removing The
Door
Knurr Racks Are Ideally Lightweight
Suited For: Aluminum
n Data centers. Frame
Makes The
n Network closets. Cabinet Easier
n Telecommunication equipment. For A Single
Person To Move

Low Profile
Casters
Allows 42U
Cabinet To
Roll Through
Standard
Doorway

10
Liebert MCR
Mini Computer Room Enclosure
Liebert IP Telephony
Availability System

Protecting The Edge


Of The Network

Racks, Integrated Cabinets


Liebert has brought together several of
our product solutions to create the IP
Telephony Availability System. Especially
designed to protect switches, routers and
Secure Door other critical components, this solution is
lockable door ideal for use in remote locations such as
provides an extra branch offices, retail stores and other edge
measure of security of the network applications. Housed in a
by limiting access Liebert Foundation™ wall mount enclosure
to critical or freestanding enclosure.
equipment The Liebert IP Telephony Availability System, version 1.0, has
met the Cisco Technology Developer Partner Program test
criteria for interoperability with Cisco CallManager Express
3.1, Cisco Unity Express, release 1.1.2, Cisco Unity 4.0 (3), and
Unity Bridge 3.0 (2).
BCM
(Back-up Cooling
Module) True On-Line Power Protection

Sealed Door
specially designed
rubber gasket
provides NEMA12
sealing protection
The Liebert GXT3, a true double conversion
Liebert GXT3 UPS, delivers the high level power quality
on-line UPS required to fully protect critical network
switching components from all power
problems. Available in sizes from 500 up
ECM to 3000 VA.
(Environmental
Control Module)
Continuous Power Availability

In most cases, your critical routers and


other network components cannot be
without power even for scheduled UPS
maintenance. To meet this need, the
Bundled UPS
Wall Mount Liebert MCR Liebert 2U Power Output Distribution (POD)
systems available
Systems 12 U Enclosure system ensures continuous uptime by
Hinge Body “swing For smaller spaces providing maintenance bypass capability
out” and 12” depth requiring the as well as power output distribution.
Low Profile available. complete power
and cooling
protection. Power System Monitoring,
Communications &
Remote Control
EX Cable Internal Power
Management Distribution
The Liebert Webcard,
Channel A wide range
housed within the UPS,
This versatile of installed power
will deliver SNMP and
option helps to strips is available to
web-management communications
enhance cabling better accommodate
capabilities to your power system, including
organization and power distribution
Dual-Split Rear the ability to remotely reboot the switch by
internal airflow. needs within the
Door available cycling the UPS power off and on.
enclosure.

11
Smart Solutions Deliver Efficiency, Capacity,
Availability, Control

To help you achieve efficiency in all aspects of your data


center, Emerson Network Power has developed the Smart Smart Solutions give you the efficiency, economy,
Solutions intelligent, integrated infrastructure for data interoperability and control to implement an
centers. The family uses a global design approach that can be
infrastructure strategy that outperforms any
localized for specific geographies.
you’ve ever seen.
Smart Solutions let you cost-effectively achieve and manage
your objectives for efficiency, capacity and availability. These Efficient
offerings provide fast and easy implementation, through Up to 28% in energy savings
interoperable systems: precision cooling, UPS, power Increase rack density up to 60%
distribution/conditioning, management software and racks.
Economical
No other solution offers the industry’s leading power, Reduce implementation costs compared to
precision cooling and data center infrastructure management conventional data center approaches
systems for such a wide array of applications and
environments.
Interoperable
Maximize use of existing infrastructure
Smart Solutions are fast and easy to implement, and are Depending on the solution, you can have a
supported by local data center design experts and service complete infrastructure in just weeks
professionals. Smart Solutions are typically more affordable
Controllable
than conventional data center designs – and they are more
energy efficient. Easily enforce add / change policies
Speed IT administration request response times
Each Smart Solution offering integrates industry best by up to 30%
practices in data center design and operations including:

Hot air and cold air separation

Cold air containment

High availability and high efficiency UPS

High-efficiency precision cooling

Space-savings, small-footprint

Modularity for flexibility and easier expansion

Integrated monitoring and control to optimize efficiency in


planning and management

Unique local service for design audits, configuration


support, installation support, maintenance and repair

Emerson Network Power brings together the industry’s finest


power, precision cooling, monitoring and management
brands and businesses, including Liebert, Knurr, ASCO,
Avocent, Chloride, Energy Systems and Surge Protection
solutions. The Smart Solutions offerings deliver Efficiency
Without Compromise™ within the data center.

12
SmartRow™ The SmartRow™ solution has a room
Intelligent, integrated neutral design that lets you avoid many
infrastructure of the significant costs that come with a
in a self-contained line-up conventional data center buildout.

Capacity: 20kW Favorable implementation costs


compared to using a conventional data
Racks: 3-6
center approach, due to savings from
Type: Self-contained integrated fire suppression and ability
to work in an existing non-raised floor
Floor: Primarily non-raised environment without dedicated room
cooling.
Key Applications: Small data
centers; remote sites; disaster Reduce energy consumption by up to
recovery 27% compared to a data center with
conventional design, perform less
maintenance and reduce the costs of

Smart Solutions
adding new equipment.

Order and install in just weeks.

SmartMod™ The SmartMod™ enclosure lets you save


Intelligent, integrated on upfront design and implementation
infrastructure in a rapid by delivering fully integrated power,
deployment enclosure. precision cooling, integrated fire
suppression and management systems in
Capacity: 30-400kW a modular, standalone design.

Racks: 6-28 Rapidly deploy a comprehensive data


center infrastructure solution.
Type: Self-contained
Implement a stand-alone solution
Floor: N/A
that won’t burden the existing
Key Applications: Supplemental infrastructure.
data center capacity; remote
Save on design, equipment purchase
data centers; disaster recovery
and installation.

Order and install in just months.

Reduce energy consumption by up to


28% compared to a data center with
conventional design.

SmartAisle™ The SmartAisle™ offering can increase


Intelligent, integrated your efficiency through row-based power
infrastructure using and precision cooling systems.
row-based building blocks.
Save up to 27% in energy costs
Capacity:Most cost effective
up to 400kW Keep infrastructure on pace with
equipment changes, with systems that
Racks: Most cost-effective operate together and can be quickly
up to 40 reconfigured

Type: Open or aisle Increase capacity without replacing old


containment available infrastructure.

Floor: Raised, non-raised

Key Applications: Small and


medium data centers; high-
density zones in all data centers;
new or retrofit

13
Liebert MB Modular Busway:
Flexible, Economical Power Delivery From PDU To Rack

Emerson Network Power brings you the most flexible, robust power
distribution system on the market today: Liebert MB Modular Busway.

Modeled on the Siemens XJ-L busway, Liebert MB provides flexible


modular power distribution in high tech environments. Power cables
are replaced. Installation is simplified. Each rack has a clearly identified
breaker. Air flows freely. Installation and ongoing costs are reduced.
And the solution is organized and easy to maintain.

Liebert MB is a convenient, economical way to provide power from a


room power distribution unit to the IT rack equipment. This compact,
modular system is an organized alternative to custom cabling, and is a
perfect solution for dynamic data centers that require frequent updates
and changes with little to no power disruptions.

System Compatibility
Liebert MB is compatible with the Knurr DCM rack and the entire family
of Liebert power products — rack and room PDUs, UPS systems and
surge protective devices — providing power distribution and protection.

Ideally Suited For:


Large or medium data centers.
Data centers with variable and dynamic loads.
 High power density applications.
Single or dual bus configurations.

Liebert MB Features:
Comprehensive offering of standard fittings.
Reconfigure to meet growing and changing IT demands.
Lightweight and flexible for easy installation, but rugged
enough for durability.
15-30% lower cost than typical cabling materials and
labor/installation costs.
UL 857 and CSA 22.2 agency ratings for safety.
100A, 225A and 400A availability.
Hot swappable, user replaceable bus plugs provide both
flexibility and maximum safety.
Bus plug capacities from 30A to 100A.
Pre-assembled bus plugs with whips or receptacles.
Multiple bus plug port spacing available. Liebert Power Monitoring Capabilities
Rack-mount, ceiling suspended or underfloor mounting options. The operation of Liebert MB can be monitored using:
Liebert SiteScan® Web Centralized Monitoring System.
Optional metering at bus plugs or tap box.
For more information, see pages 52 and 53.

14
Modular Power Distribution
Liebert NX Liebert Liebert Liebert MB
Battery Cabinet NX UPS Tap Box NX BDC Modular Busway Bus Plug

Knurr Rack Liebert MPX Rack PDU

15
Liebert MPX - Adaptive Rack PDU:
Respond To Change While
Watching Your Bottom Line

Confidently take on the uncertain future of connected power Scalable Design Allows
requirements with Liebert MPX, the most responsive and adaptive Onsite Configuration
To Fit Immediate IT
rack PDU available. With Liebert MPX adaptive technology, you
Equipment Needs.
can economically increase availability of critical systems by
The Liebert MPX Adaptive
leveraging hot-swappable modular power and managing power
Rack PDU features essential
all the way to the receptacle level. characteristics to support
fast-paced, growing data centers.
Liebert MPX Benefits:
Adaptive capacity, distribution, monitoring,
Hot Swappable Output Power
control and management of critical devices. Deploy easily to get IT equipment
Flexibility to respond to constant change. online quickly
Buy only what you need and build on your investment.
Secure communication.
Receptacles & Modules
May be remotely controlled and
Reconfigurable Power Capacity metered, providing operator
& Distribution flexibility and allowing increased
site security
Liebert MPX is the perfect choice to respond to the needs
of a growing data center. Relocate or add IT equipment to
support changing needs, by easily reconfiguring the power Rack PDU Card (Liebert RPC)
Mounts in the Power Entry
input and distribution. Module and provides
upgradable network
Liebert MPX Features: communications, sensor
Industry leading operating temperature—up to 55˚C /131˚F and local display interface

to support hot Internal rack environments. Input Power


Accurate power metering of +/-1% voltage & current May be reconfigured to
for assured oversight. support changing power
Energy and power metering down to the needs, single and three
phase input.
individual receptacle.
Can be positioned for top
Comprehensive alarming including notification of
or bottom rack entrance.
overloaded branch circuits.
Environmental sensing with threshold and alarm set-points.
Liebert Power Monitoring Capabilities
Notification on the loss or removal of individual rack
equipment loads. The operation of Liebert MPX
can be monitored using:
IP consolodation via Rack PDU Array™
Liebert RPC Rack PDU Card.
- Liebert Nform Monitoring System.
- L iebert SiteScan® Web Centralized
Monitoring System.
- Secure Web/SNMP Interfaces.
- Liebert RPC-BDM Local
Display Module.
For more information, see page 18.

16
Rack PDU Card
(Liebert RPC)
Provides upgradable
network communications,
Liebert MPH—Managed Rack PDU: sensor and local display
interface
Advanced Monitoring And Control Support

Liebert MPH is a flexible Rack PDU solution with remote Liebert MPH Features:

Rack PDU
monitoring and control capabilities as well as environmental Monitors electrical and
input options. It offers multiple power input selections environmental parameters with
and output configurations in both vertical zero-U and set threshold and alarm tools.

rackmount form factors. Up to four Liebert MPH PDUs may Industry leading operating
temperature—up to 55˚C/131˚F
be interconnected as a Rack PDU Array™, consolidating user
to support hot internal rack
IP connections and device monitoring. environments.
Controls and manages individual
Liebert MPH Monitoring
receptacles.
And Control Support
Predicts overcurrent conditions
Monitored electrical parameters include: voltage,
before they become critical.
current, total real power (watt), and energy
consumption (kW-hr). Capacity based current Remote monitoring at strip
and branch.
thresholds provide comprehensive alarm
notifications from the Rack PDU and branch. Card-based communications.
Local displays are easily located
to suit a crowded and changing
rack environment.
Supports mounting in 19” EIA,
42U rack environments—offered
in vertical, zero U and rackmount
form factors.

Allows you to predict failing


conditions before they occur and
proactively manage connected
equipment for maximum uptime.

Liebert Power Monitoring Capabilities

The operation of Liebert MPH


can be monitored using:
Branch Overload
Liebert RPC Rack PDU Card.
Protection
- Liebert Nform Monitoring System.
- Liebert SiteScan® Web Centralized
Monitoring System.
- Secure Web/SNMP Interfaces.
- Liebert RPC-BDM Local
Flexible Power Cord Mount
Display Module.
User adjustable for horizontal or vertical
For more information, see page 18.
orientations

17
Monitoring Anywhere You Need It
From the individual receptacle of
each discrete device to the complete
Liebert MPX and Liebert MPH: rack PDU, monitoring is available
Enhanced Performance And Management to meet user needs. Displays are
designed for easy user location to fit
Of Dynamic IT Spaces changing site needs.
Display and sensors are designed
for easy mounting on the rack.
IT Space Is A Dynamic Environment Emerson Network Power’s portfolio of
A single display can manage up
products from brands such as Liebert,
Today’s successful businesses depend on to four Liebert MPX or Liebert
Knurr, Alber, Aperture, and ASCO provide
adaptable technologies to help them respond MPH systems and associated
innovative, flexible solutions that ensure
quickly to market demands. Your data center monitoring accessories. Liebert
reliability and efficiency. With the help of
must be built on a support infrastructure MPX and Liebert MPH include
monitoring and management tools from
designed to match the power and cooling the following capabilities:
Emerson Network Power, the result is
needs of rapidly changing IT initiatives such
an infrastructure that will enable you to Web-based monitoring.
as virtualization and consolidation. Each
proactively manage your critical IT spaces. Liebert Nform IT based.
IT change, move or addition will affect the
The Rack PDU family of products is the centralized monitoring.
entire support infrastructure. You need Liebert SiteScan centralized
connectivity point of IT systems into
products and support that ensure your monitoring.
your power and cooling infrastructure
IT systems will operate reliably in these User located local display with
and the critical interface to an efficient
environments. the ability to view up to four
M
and effective infrastructure management
structure anagement PDU’s.
Infra ecosystem.
Liebert SN rack sensors.

Remote Monitoring Capacity planning


Alarm notification Asset management
Remote Control Expert services

Surge
Protection
Cooling

Power UPS Heat


Liebert MPX may be remotely
monitored and controlled via secure
PDU
web/SNMP interfaces or Liebert
Nform or Liebert SiteScan Web.
Pow e
er & C ctur
oo ling Infrastru

Liebert RPC
(Rack PDU Card)

Network

Rack PDU Array


(up to four systems)
Status Display (RPC-BDM)
is easily moved to the most
Environmental convenient spot for the individual
Sensors rack—even outside the rack. This
tethered display may be located for
RPC-BDM user convenience.
(Local Display Module)
Web Monitoring Liebert SiteScan
Liebert Nform
Web

18
Knurr DI-STRIP: Basic Rack PDU,
Standard And HighPower Systems

Knurr Basic Rack PDU is the right answer for data center users Knurr DI-STRIP Features:

Rack PDU
selecting robust, economical and flexible rack power solutions.  ultiple configurations and input power options
M
available including international compatibility.
Knurr DI-STRIP® meets a broad range of power distribution requirements for IT and
 he addition of the Basic Rack PDU Expansion
T
other applications. Designed especially to handle the growing number of electronic Unit allows for growth.
components that can be housed within network cabinets and server racks, the  0ft. (3m) power supply cable offers room
1
space saving product line is available with a range of accessories including circuit for movement.
breakers, overvoltage protection and more. Reliable and robust solution.
Worldwide approvals and certification.
F ull-length brass busbar on Standard models
enhances operational reliability.
 tandard system extruded casing and a HighPower
S
system heavy duty casing provide durability.
I ndustry leading operating temperature—up to
55˚C/131˚F to support hot internal rack environments.
 imple and quick installation on the rack’s extrusion
S
requires minimal space and reduces installation time.

Flexibility to meet
a broad range of
requirements

19
Liebert PSP Stand-by UPS:
350 - 650VA, 1-Phase

Protection For The PowerSure PSP from Liebert is a compact, full featured Liebert PSP Features:
UPS that delivers cost-effective power protection. Designed
Desktop And with simple controls for easy operation, the PowerSure PSP
Three battery-backed UPS outlets.

Small Network provides over four minutes of battery back-up at full load —
One surge protection-only outlet.

Applications more than enough time to save work in process and shut
Up to five minutes of battery
backup at full load.
Liebert desktop power solutions are down your system. User replaceable batteries.
designed for applications where one Perfect for desktop applications, the PowerSure PSP RJ-45 port for data line
or a few pieces of equipment require provides one-on-one power protection for PCs and surge protection.

surge suppression or basic power other sensitive electronic equipment. Two models Advance early warning of
available: 350 and 500VA at 120VAC and 500 and UPS shutdown.
protection with battery back-up.
650VA at 230 VAC. USB port, Liebert MultiLink
One-On-One Protection Software shutdown software
For maximum flexibility, a choice of communications
The Liebert family of products and USB cable.
options are available — USB, serial or contact closure. This
includes surge protection strips option solves the legacy systems dilemma of what to do Two-year replacement warranty.
and line-interactive UPS to give with equipment that does not have USB capabilities. A
you a real choice in desktop and MultiLink™ automated shutdown software CD, serial
network component protection. communications cable and USB cable are also included.
Liebert Products Offer
Stand-by UPS
One-On-One Power
Protection Solutions For:
TVSS & Load
Source EMI/RFI
Home And Small Office Filters
Desktop PCs. Battery Inverter
Network Workstations.

Network Routers, Bridges


And Hubs.

Point-of-Sale Terminals.
Other Sensitive Electronics.
Liebert Power Monitoring
Capabilities

The operation of the Liebert PSP


can be monitored using:

Liebert MultiLink® Automated


System Shutdown Software.

For more information,


see pages 52 and 53.

20
Liebert PSA Line-Interactive UPS:
500 – 1500 VA, 1-Phase

High-Performance Power Protection For PC’s And Office Equipment

Desktop UPS
Liebert PSA is an economical Other Standard Features Included
line-interactive UPS that offers On All Liebert PSA Models:
Three to six battery-backed UPS outlets,
full-featured power protection for
depending on model size.
small office computers and electronic
One to two surge-only outlets,
equipment. It is available in the differentiated by color.
following sizes: 500, 650, 1000 and Up to five minutes of battery backup time at full load.
1500 VA at 120 VAC or 230 VAC. User replaceable batteries.
 Advance early warning of UPS shutdown. 500/650 VA back view
Designed with simple controls RJ-45 port for data line surge protection.
for easy operation, the Liebert Two-year warranty.
PSA provides up to five minutes
of back-up time at full load –
more than enough time to save
work in process and shut down Line-Interactive UPS
your connected equipment.
TVSS & AVR &
USB shutdown software and Source EMI/RFI Transfer Load
Filter Switch
a USB cable are also included,
to allow remote alerts and
automated graceful shutdown of Battery Inverter
the connected systems. Liebert
PSA offers unique features and
extraordinary performance not
1000/1500 VA back view
normally found in similar products
in this price range.

Liebert Power Monitoring


Capabilities

The operation of the Liebert PSA


can be monitored using:

Liebert MultiLink® Automated


System Shutdown Software.

For more information,


see pages 52 and 53.

21
Liebert PSI And Liebert PSI-XR Line-Interactive UPS:
750-3000VA, 1-phase

Rack-Mounted
Power Solutions
For Growing IT
Networks
Rack-mounted servers are at the
heart of today’s network computing
systems. These critical components
need reliable, compact power
protection that will keep pace with
their growing needs.

Protection That Fits


In Anywhere
From line-interactive units to Proven high-level performance and reliability for server and network power protection.
true on-line models, Liebert
rack-mount UPS systems are
Designed for the IT environment, Other Standard Features Of Liebert PSI
Liebert PSI UPS and the Liebert And Liebert PSI-XR:
designed for reliability and
PSI-XR extended battery model Seven to eight battery-backed outlets.
space-saving flexibility. No one
are slim 2U sized rack/tower style, 0.9 Output Power Factor.
packs more power capacity and line-interactive UPS systems. Rotatable display panel.
features into a smaller package. They offer configurable input Automatic frequency sensing.
voltage windows allowing the Wider input voltage window.
Liebert Has Rack-Mount
customer to precisely match RJ-45 Data line surge protection.
UPS Solutions For:
their input voltage. A choice of Advance early warning of UPS system status.
PCs.
communications options includes Hot swappable batteries.
Network Workstations.
serial, contact closure and USB. Up to five minutes of battery backup time
Servers and Critical Nodes.
Available in 750, 1000, 1500, at full load when utility fails.
Network Routers, Bridges
2200, and 3000 VA in 120 and External battery cabinet available for
and Hubs.
230VAC models. Liebert PSI-XR models.
Large Network Peripherals.
Site wiring fault indicator.
Network Closets.
USB communications, serial and contact closure
VoIP.
Storage Systems. communication option.
Remote emergency power off.
Point-of-Sale Terminals.
Rack rail kit included.
Test Equipment.
Two-year warranty.
Other Sensitive Electronics.
Liebert PSI-W and Liebert PSI-XRW web-enabled models
ship with IS-WEBRT3 card installed, for fast deployment.

22
4
Optional Liebert MicroPOD 2U POD
output distribution and maintenance
bypass module ensures continuous
uptime, even during UPS maintenance.

Line-Interactive UPS With Power-Factor Correction Liebert PSI-XR UPS With Internal Battery

Rack-Mount UPS
Liebert Input Output
TVSS & AVR & DB-9 IntelliSlot Circuit Circuit
Source EMI/RFI Transfer Load Port Port Breakers Breakers Receptacles
Filter Switch

Bi-directional
Battery
Converter

Voltage EPO USB RJ-45 External Power


Configuration Port Data Line Battery Cord
DIP Switch Connectors Connector

Optional External Battery Cabinet


Add up to six cabinets for additional runtime

Liebert PSI UPS With Internal Battery


Liebert RJ-45 Output
DB-9 IntelliSlot Data Line Circuit
Port Port Connectors Breakers Receptacles

Voltage USB Input


Configuration Port Circuit
DIP Switch Breakers

Liebert Power Monitoring


Capabilities
The operation of Liebert PSI can
be monitored using:
Liebert MultiLink®Automated

System Shutdown Software.


Liebert Nform Monitoring System.
Optional Liebert
For more information, IntelliSlot Web Card
see pages 52 and 53. (PS ISWEBCARD)
provides SNMP and
web-based
management

23
5
Liebert GXT3 On-Line UPS:
500-3000VA, 1-phase

Compact UPS combines on-line reliability, configurability and internal batteries.

Liebert GXT3 leads the industry in combining small customize Liebert GXT3 performance to your
size, high capacity and multiple features. Designed specific requirements, providing a new level
to be either rack-mounted or installed in a tower of power protection control and adaptability.
configuration, the UPS is available in 500, 700, 1000,
1500, 2000 and 3000 VA ratings, in both 120 V and Other Features Of Liebert
230 V models. GXT3 2U Models:
A true on-line UPS, Liebert GXT3 includes features Microprocessor-based control and
such as power factor correction, internal batteries,
monitoring package.
frequency conversion, unlimited external battery
Input power factor correction.
connectability and internal bypass capability. And all
this is housed in a smaller 2U size cabinet that cuts PWM inverter.
space requirements in half while providing up to Integral dynamic bypass.
3 kVA of true on-line power – batteries included. The Integral sealed, non-spillable,
UPS can also be used with external batteries hot-swappable battery.
for extended run times. Automatic and manual battery test feature
A Windows™ configuration program, included with with push button and indicator.
each unit allows the user to program a variety of Input and output noise suppression.
operating parameters. This capability allows you to USB port.
Liebert IntelliSlot® communications port.
On-line UPS Two-year no-hassle replacement warranty.
Bypass

PFC / Rectifier Inverter


TVSS
Input & Load
Filters

DC - to - DC
Charger Converter

GXT3 Rear View

Battery

Liebert Power Monitoring Capabilities

The operation of the Liebert GXT3 can be monitored using:


Liebert MultiLink® Automated System Shutdown Software.
Liebert Nform Monitoring System.
Liebert SiteScan® Web Centralized Monitoring System.
Third-Party Monitoring Systems.

For more information, see pages 52 and 53. Optional Liebert MicroPOD 2U POD output distribution
and maintenance bypass module ensures continuous
uptime, even during UPS maintenance.
24
4
The internal battery packs are hot-swappable,
Liebert GXT3 On-line UPS: and user repleaceable. The unit also supports

5kVA-10kVA 1-phase up to four external battery cabinets for


extended run time.

High capacity, compact on-line UPS with flexible output voltage and power distribution.

Rack-Mount UPS
Emergency Power Off (EPO). Terminal
connections for a normally open or
normally closed emergency power off
switch.
Wider input voltage window minimizes
battery use — allows the UPS to support
the critical load without having to transfer
to battery, extending system availability
for when battery back-up is truly needed.
Liebert GXT3 UPS meets the need Other Product Features Of Internal automatic and manual bypass.
for higher power capacities in small
Liebert GXT3 5kVA-10kVA UPS Assures continuity of power to critical
spaces with these 5kVA-10kVA UPS
systems. These true on-line double Models Include: loads during system maintenance or in
conversion UPS systems feature User replaceable hot-swappable internal case of internal fault.
integrated maintenance bypass, as batteries. Provide four minutes of runtime Self-diagnostics. Automatically tests unit
well as optional extended battery at full load. electronics and batteries simplifying
runtime. Additional runtime with additional battery maintenance and troubleshooting.
Designed for use in either rack or cabinets. Liebert IntelliSlot Web Card provides SNMP
tower configurations, all units offer Built-in USB communications for use with and web-based monitoring and control of
the smallest available solutions for Liebert MultiLink™ Automated Shutdown UPS.
these power capacities — the 5 & Software. Allows you to monitor Standard two-year replacement warranty.
6kVA model at 120/208V output in 4U
communication between the UPS and a No-hassle warranty provides paid shipping
size, or the 8 & 10kVA unit 120/208V
output in a 6U package. A 6kVA 208V server, and ensures a graceful unattended both ways. Optional one-year and three
output 5U size model is also available. shutdown. year extensions available.
Built-in closure signals. Provides
To help meet the need for choosing a
notification to monitoring systems
single supplier for global applications,
220V, 230V and 240V 50/60 Hz of operating conditions including: on
models are offered with CE and C-tick battery, low battery, battery mode Liebert Power Monitoring Capabilities
markings. shutdown and any mode shutdown.
The operation of the UPS can be monitored using:

Dual Voltages For Multiple Liebert IntelliSlot Web Card.


Liebert
MultiLink® Automated System
Applications Shutdown Software.
Simultaneous output voltages Liebert Nform Monitoring System.
of 240/120, 208/120, 230/115, Liebert
SiteScan® Web Centralized Monitoring
220/110, or 200/100 VAC provide the System.
flexibility to adapt to multiple load Liebert
Universal Monitor And Remote Power
Monitor Panels.
requirements without the need to add
Third-Party Monitoring Systems.
additional transformers that take up
For more information, see pages 52 and 53.
extra space and add weight.

25
5
Liebert Nfinity® On-Line UPS:
4-20 kVA, 1-phase

Protecting The The Liebert Nfinity power system is a scalable 4


to 16 kVA or 12 to 20 kVA UPS designed with N+x
Enterprise: High parallel redundancy to provide a fault-tolerant
Availability UPS network of power protection.
Protection For
Mission-Critical The modular design of the Liebert Nfinity power
system was devised to provide easy scalability to
Applications users as their power demands grow. Configurations
can be cost-effectively upgraded without
The need to safeguard critical re-investing in a new system or installation.

operations from power problems A True On-Line System That Delivers Additional Features Of The
can be solved through the use of Continuous, Regenerated Sinewave Liebert Nfinity Power System:
Output Power Hot-swappable modules allow
large-scale UPS systems.
The Liebert Nfinity is a true on-line, the user to replace modules or upgrade
double-conversion UPS that provides 100% power the system without disturbing
A Powerful Defense conditioning, zero transfer time to battery, no connected equipment.
change in output voltage and better transient Continuous self-diagnostics
Against Uptime Threats
suppression than line-interactive units. detect and isolate faults to prevent
Liebert offers a full range of cascading system failures, as well as to
enterprise power protection Its unique frame design houses all of the modular
simplify maintenance and
system components, including 4 kVA power
solutions for any size facility from a troubleshooting.
modules, battery modules and system control
Patent pending intelligent
small computer room to the largest modules. By simply installing additional power
bypass technology provides seamless
data and communications centers. or battery modules, you can expand your current
transfers to and from
system, extend backup runtime or add redundancy.
the bypass source.
Liebert Enterprise UPS Intelligent power modules provide protection Wide input voltage window minimizes

Solutions Are Ideal For from all power aberrations, and a patent pending battery operation
electrical current-sharing technology provides to maximize battery life.
Large-Scale Data Centers.
equal distribution of power among all modules. Fully assembled and factory-tested,
Facility-Wide Networks.
The IntelliBattery™ modules utilize multiple simple to install and ready for use for a
Large-Scale Telecommunications
sensors to continuously monitor battery voltage, plug-and-play solution that is functional
Centers. current and temperature to determine and right out of the box.
Colocation Facilities. predict performance. Additional battery cabinets can
Internet Data Centers. The IntelliControl™ module works with the user be added for backup times up
Server Farms. interface to provide vital information about the to 72 hours.
Data Warehouses. condition of the power and battery modules. Two-year limited warranty for repair or
Network Management Centers. Liebert Power Monitoring Capabilities replacement with warranty extensions
also available.
Medical Imaging Equipment. ®
The operation of the Liebert Nfinity UPS can be
Test and Laboratory Facilities. monitored using:
Liebert IntelliSlot Web Card.
Industrial Process Control ®
Liebert
MultiLink Automated System Shutdown
Operations. Software.
Liebert
SiteScan® Web Centralized
Monitoring System.

26
4 For more information, see pages 52 and 53.
Slimline
Distribution
Cabinet Power
Module Battery
Cabinet

Liebert NX On-Line UPS:


10-30 kVA, 3-phase

Power designed to grow with your needs.

Enterprise UPS
The Liebert NX 10-30 kVA product family offers true
on-line, double conversion, three-phase UPS systems
that deliver complete, centralized power protection
for mission-critical systems. Available in 10, 15, 20 &
30 kVA capacities, these rugged units are designed to
meet the high availability power needs of a wide variety
of IT applications. Liebert NX 10-30 kVA UPS systems
combine advanced operating features, compact size and
Other Features Of Liebert NX 10-30 kVA UPS Models:
Increases growth flexibility by handling larger loads, and offers the
low cost of ownership in a range of sizes to suit room or
ability to parallel like-sized 20 and 30 kVA modules for increased
data center needs.
capacity and redundancy.
The “all-in-one” design of the Liebert NX 10-30 kVA Achieves higher availability by reducing the number of UPS units
UPS provides more protection security and efficiency required to power your room.
than using separate, smaller power units spread Reduces total cost of ownership through the use of longer life
throughout the facility. The Liebert NX delivers complete batteries and simplified preventive maintenance.
protection with a true on-line IGBT-based double Wider input voltage window and frequency tolerances contribute to
conversion design. The system’s advanced topology higher system availability by minimizing battery usage.
features a digital signal processor controlled IGBT Operates under a wide variety of conditions, handling 100% nonlinear
rectifier and IGBT inverter. loads with 3:1 crest factor, as well as 100% unbalanced loading.
IGBT-based power factor corrected rectifier enables the Liebert NX to
achieve its impressive THD and PF performance.
Advanced inverter control technology provides the highest output
power quality, ensuring very low output voltage THD and superior
waveform to protect connected loads.
Fully digital control technology provides a highly accurate, drift-proof
®
control compared to traditional analog electronics.

Liebert Power Monitoring Capabilities

The operation of the Liebert NX 10-30 kVA


UPS can be monitored using:
Liebert IntelliSlot Web Card.
Liebert
MultiLink® Automated
System Shutdown Software.
Liebert Nform ™ Monitoring System.
Liebert
SiteScan® Web Centralized
Monitoring System.
Third-Party Monitoring Systems.

For more information, see pages 52 and 53.

27
5
Liebert NX On-Line UPS:
40-200 kVA, 3-phase

Now There’s A Data Center UPS That Matches Your Growth Plans.
For high availability, high capacity applications, the Softscale™ technology provides flexibility to increase UPS capacity
transformerless Liebert NX 40-200kVA UPS systems offer true without changes in your infrastructure. From 40 up to 80kVA, 80
on-line, double conversion technology to protect and condition up to 120, and 160 to 200. You may also parallel UPS modules for
against the full range of power irregularities. Plus they do it with a capacity and redundancy.
level of flexibility not previously found in systems of this size.
The Liebert NX power core combined with the optional Liebert
A wider input voltage window and frequency tolerances help to NX BDC (Bypass Distribution Cabinet) lets you simplify power
minimize transfers to battery, reducing the number of charging distribution and voltage conversion. This combination provides
and discharging cycles. Availability is also enhanced with a triple packaged power distribution for today’s rack-based data centers
mode battery charger that enables fast battery recharge. Longer and IT facilities.
battery backup time may be achieved by paralleling additional
battery cabinets to the system.

Liebert Power Monitoring


Capabilities

The operation of the Liebert NX 40-200


kVA UPS can be monitored using:
Liebert IntelliSlot Web Card.
Liebert
MultiLink® Automated
System Shutdown Software.
Liebert
Nform ™ Monitoring
System.
Liebert
SiteScan® Web Centralized
Monitoring System.
Third-Party Monitoring Systems.

For more information, see pages 52


and 53.

Battery Cabinet Power Core Liebert NX BDC

Liebert NX UPS 160-200 kVA

28
Cutting-Edge Power Technology
Makes The Difference

Liebert NX UPS Systems Incorporate A Softscale™ technology, paralleling capabilities and Eco-mode™ all

Enterprise UPS
Number Of Other Exceptional Features: contribute to lower initial, incremental and operating costs.
High overload rating handles 125% for 10 minutes,
150% for one minute and a 1000% overload for 10 Liebert NX 40-200 kVA UPS Systems
milliseconds. Softscale Technology
Digital controls provide the fastest possible
Liebert NX 40-200 kVA UPS systems have Softscale technology
power management to enhance reliability, accuracy and
that provides flexibility to increase UPS capacity by 20 or 40kVA
efficiency.
Front access models available for installation along without changes in your infrastructure. Allows paralleling of
a wall. Front and rear access models available for unlike-sized models for capacity or redundancy. Designed for
installation in a row. optimized performance with the same high efficiency at 40%
Compact footprint requires less floor space, leaving you utilization as at 100% utilization.
with more room for other equipment.
Load Bus Synchronization standard. Paralleling Capabilities
Soft Switching technology increases efficiency Liebert NX 40-200 kVA systems allow you to parallel UPS
by up to 2% and saves energy. modules for capacity and redundancy, eliminating the
Integrated ground fault detection allows for effective batteries as a single point of failure because each UPS has its
transformer-less design while saving space and lowering own isolated battery. Liebert NX also features integrated dual
the unit weight. bus synchronization as a standard feature. This provides the
Parallel for redundancy or capacity. capability to synchronize the outputs of two independent UPS
Active input rectifier is generator modules when they are configured as a redundant system
and utility friendly.
feeding independent distribution paths.
Web card monitoring standard.
One year warranty. Eco-Mode High Efficiency Configuration
If selected, this operating mode switches the UPS to static
bypass during normal operation, increasing efficiency to up to
97% at full load. When power problems are detected the UPS
automatically switches back to double conversion mode.

Liebert NX BDC
The optional Liebert NX BDC provides flexibility in input and
output voltage for a variety of applications. This cabinet is
available in capacities to cover the Liebert NX UPS range of
40-200kVA. The monitoring panel matches the UPS unit. Power
and control cabling from this cabinet to the UPS is included,
enhancing ease of installation and availability. For ease of
installation and maintenance, the cabinet offers top or bottom
cable entry and models are available in front and rear access, or
front access only configurations.
Liebert NX Power Core
40-80 kVA

29
Liebert APM™ On-line UPS with FlexPower Technology:
15-90kVA, 3-phase

Liebert APM is a transformer-free, On-line double-conversion technology The cost-efficient Liebert APM provides
on-line UPS that allows quick and easy and internal redundancy combine to the reliability of an enterprise UPS, and
capacity increases with the addition of provide protection from the full range of the flexibility to adapt to increasing power
rack-mounted FlexPower™ core hardware power irregularities, offering the highest demands. This is a true, best-in-class solution
assemblies. The core assemblies allow availability. from the leader in power and cooling solutions
the UPS to expand for capacity or for computer rooms and data centers. Key
With efficiencies of up to 94% at typical
redundancy in 15kW increments within a features and benefits include:
load levels, Liebert APM offers one of the
single cabinet — 15kW to 45kW or 90kW. Up to 94% efficiency — High efficiency results
industry’s highest efficiency ratings. The
No additional floorspace is required. in lower energy consumption
UPS is even more efficient when sized in
FlexPower core assemblies may even be Front service access — for quick and easy
accordance with present system needs,
added without powering down connected installation
instead of purchasing a larger capacity
equipment. Transformer-free design — provides a
system to anticipate future requirements. smaller footprint and lower cost compared to
transformer-based systems
Matching bypass and distribution cabinet
— increase reliability and safety by switching
the protected load to bypass power for
maintenance and service
Matching battery cabinets — provides added
back-up capacity for extended runtimes
Distributed controls — each FlexPower core
assembly includes DSP controls, minimizing
possibility of single point of failure
Standalone static bypass module — features
independent controls in separate assembly to
provide higher reliability
Top or bottom cable entry — enables
installation on raised or non-raised floors
Large dot-matrix monitor with graphical
display — allows easy viewing and
comprehensive system information Includes
three Liebert
IntelliSlot ports for web-based
communications ability — Liebert IntelliSlot
card IS-485EXI allows communication with
Liebert SiteScan; Liebert IntelliSlot card
IS-WEBL allows communication with Liebert
Nform (90 day license included)
One-year warranty — provides full system
Liebert APM BDC, Liebert APM 90 kW FlexPower Core, coverage for one year
and Liebert APM External Battery Cabinet

30
Other Product Features Of

Enterprise UPS
Liebert APM UPS Include:
Internal bypass allows FlexPower assemblies to
be added or replaced without powering down
the connected equipment
45kW model includes internal batteries. More
runtime is available with optional external
battery cabinets
90kW units use optional external battery
cabinets for battery runtime
Conveniently positioned, easy-to-reach
power terminations simplify unit wiring and
installation
Enterprise-quality batteries in an external
battery cabinet provides backup time for 90kW
frame size, and additional runtime for 45kW
frame size
Withstand rating of 65kAIC ensures reliability
and safety under even the most extreme utility
conditions
Unity power factor design (kW=kVA) is
optimized for today’s high power factor loads

Liebert APM is ideally suited for:


Small to medium-size data centers
Server rooms Liebert Power Monitoring Capabilities

Production areas Liebert APM 90kW


The operation of the Liebert Series 610 UPS can be
FlexPower Core
monitored using:
Labs and testing facilities
Liebert IntelliSlot Web Card.
Telecommunications or process Liebert
MultiLink® Automated System Shutdown
control centers Software.
Liebert Nform Monitoring System.
Liebert SiteScan® Web Centralized Monitoring System.
Liebert Universal Monitor And Remote Power Monitor
Panels.
Third-Party Monitoring Systems.
For more information, see pages 52 and 53.

31
Liebert Npower™ On-Line UPS:
30-90 kVA, 3-phase

Liebert Npower is the next generation of large-scale UPS, utilizing Standard And Optional Features Of The
true double-conversion on-line technology to protect against the Liebert Npower UPS:
full spectrum of input and output power disturbances. Liebert 1+1 redundant configurations (for single-bus systems)
Npower’s all-digital ActiveStar™ controls are DSPbased and feature a that allow concurrent maintenance resulting in virtually
unique, patent-pending technology that allows it to make ultra-fast 100% availability of conditioned power
adjustments to changing loads, including subcycle pulse-width Load bus synchronization option for dual-bus systems
corrections to keep the output voltage waveform nearly flawless. The with two power feeds for added availability (for use with
Liebert Npower system is available in seven models ranging from 30 Liebert transfer switches or dual-input PDUs)
kVA up to 130 kVA.
Excellent efficiency powering non-linear, unbalanced and
The Liebert Npower is rugged enough to handle load branch faults, crest loads
input faults, 100% step loads, PDU startup inrush and motor-load Small footprint in a full-featured system
startup. Output voltage distortion (THD) typically measures less Exceptional overload and transient performance
than 2.5% — even under worst-case conditions. The combination of All DSP-controlled UPS
rugged inverter and continuous rated static switch gives the Liebert Easy-to-read screen and navigation menu on a large LCD
Npower exceptional overload capability. display
Superior battery algorithms used to minimize operation
of batteries and include self-test and temperature
compensated charging

Liebert Power Monitoring Capabilities

The operation of the Liebert NX 40-200 kVA UPS can be


monitored using:
Liebert MultiLink® Automated System Shutdown
Software.
Liebert Nform™ Monitoring System.
Liebert SiteScan® Web Centralized Monitoring System.
Liebert Universal Monitor And Remote Power Monitor
Panels.
Third-Party Monitoring Systems.
Albér Battery Monitoring.
For more information, see pages 52 and 53.

Liebert Npower UPS

32
Enterprise UPS
Great Value in a Mid-Range UPS High-Availability Configurations
The Liebert Npower gives you more UPS for about the same initial The Liebert Npower UPS can be used reliably as a single
cost as lesser products. Furthermore, the Npower will usually module and in various redundant configurations. The
cost significantly less over the lifetime of the product. The value Npower 1+1 Redundant option, described on pages 10-11
comes from several elements: exceptional protection, higher of this brochure, is a cost-effective parallel-redundant
efficiency, lower installation, maintenance and operating costs, system. Parallel redundancy improves maintainability and
smaller total system footprint and more standard features. fault tolerance, thereby enhancing system availability.

Higher Efficiency in Real-World Applications For the ultimate in high-availability systems, Npower can
be applied in various distributed-redundant (dual-bus)
Critical applications require a UPS to have an input filter (to
configurations, using our unique Load Bus Sync™ option.
reduce input current distortion) and an output isolation
Both Load Bus Sync and 1+1 Redundant configurations
transformer (to isolate your critical load), while powering
can be factory-installed or retrofitted to existing Npower
non-linear (high-crest-factor) loads at less than the rated capacity
installations.
of the UPS.

The fully equipped Liebert Npower has excellent efficiency


— typically between 92% and 93.5% — while powering
high-crest-factor loads between 50 and 100% of its rated
capacity. Furthermore, the input power factor is exceptionally
high, typically 0.95 to 0.96 for models with 480 VAC input.

In this power range (up to 130 kVA), the only way to exceed
93.5% efficiency is to leave out something important. Some
competitors omit the output isolation transformer; others put
your critical load at risk with their single-conversion UPS products.
Only you can decide if the claimed savings justify the risk.

33
Liebert NXL—Stack Up Performance
Liebert NXL is
100% Load
designed to
Low & High Line Conditions handle all severe
conditions
40˚C / 104˚F Temperature
simultaneously
50% Clogged Air Filter and still support
100% load with
Fan Failure
no need for
Liebert NXL On-Line UPS: High Altitude1500 Meters derating.

250-750 kVA, 3-phase

Liebert NXL UPS Provides Reliable Power Other Liebert NXL Features Include:
Protection And Advanced Technology Matching battery and maintenance bypass cabinets for easy
For High Power Applications. configuration.
The industry’s most reliable power protection and Top or bottom cable entry.
advanced technology has been combined into a new Internal cabinet cable wiring simplifies installation.
generation of three-phase UPS systems for high power Ship-ahead I/O section can be installed before UPS installation.
Liebert ActiveStar® Digital Signal Processor (DSP) controls—no
applications — the Liebert NXL from Emerson Network
potentiometers.
Power.
Redundant components—fans, power supplies, and
Available in 250, 300, 400, 500, 625 and 750 kVA communications cards.
single module models and multi-module systems, the Provides superior handling of present and future computer loads,
transformer-based Liebert NXL provides excellent dynamic up to 0.95 leading power factor without derating.
Color touch screen controls improve user interface and reduce risk
performance, with the ability to handle virtually any input
of human error.
condition while still providing computer grade output
Excellent dynamic performance and fault tolerance.
to critical loads.
Generator and utility friendly with low current distortion.
The leader in large UPS system installations, Emerson Front access for installation and service.
offers complete and unequalled support, including Compact cabinets require less floor space.
engineering consultation, the largest and most widespread Inter-cabinet cabling requires less hard wiring.
factory-trained service organization, and the industry’s Built-in battery cabinet breaker isolates string for ease of service.
Energy efficient operation, with up to 94% operating efficiency.
largest and most advanced production and witness test
First large UPS to be tested and UL Listed to UL1778 Fourth Edition,
facility.
which requires testing of every specification.

Liebert NXL UPS Battery Cabinet Power Core Maintenance Bypass Cabinet

34
AC Input
Liebert Power Monitoring Capabilities AC Input

Rectifier Rectifier Bypass


The operation of the Liebert NXL UPS can be monitored using: AC Input
Rectifier AC Input
Rectifier AC Input
Bypass
AC Input AC Input AC Input
Liebert MultiLink® Automated System Shutdown Software. Rectifier Rectifier
Liebert Nform™ Monitoring System. Rectifier Rectifier

Liebert SiteScan® Web Centralized Monitoring System. System


Static
Bypass Bypass
System
Liebert Universal Monitor and Remote Power Monitor Panels. StaticSwitch
Output
Bypass Breaker
Bypass
Switch
Output Third-Party Monitoring Systems. Breaker
er Battery Battery
Battery Battery
Four
 Liebert IntelliSlot ports. Ships with standard 485 Liebert Inverter Inverter
SiteScan Web interface. Inverter Inverter
Critical Bus
ACBus
Critical Output Albér BDSi Integrated Battery Monitoring System.
AC Output
For more information, see pages 52 and 53.
UPS Output AC Output
Breaker
UPS Output To Load
AC Output
Breaker To Load

Optimized Performance Liebert NXL Single Module System One-Line (250-750 kVA)

Enterprise UPS
Intelligent Eco-Mode™ — Liebert NXL offers up to 97%
full load efficiency during user-selectable Intelligent Bypass
AC Input
Bypass Static Switch
Eco-Mode™ operation. The always-on inverter ensures AC Input Static Switch
Rectifier Inverter
Rectifier Inverter
high availability and seamlessly assumes the load in case
Rectifier AC Output
of a utility power disturbance. AC Input
Rectifier to Load
AC Output
AC Input to Load
Intelligent Paralleling™ — Modules paralleled with
a system control cabinet (N+1 configuration) may be Battery
Battery
customer selected to use Intelligent Paralleling, which
increases efficiency by turning off redundant modules.
Off time is equally distributed between all modules. Liebert NXL 1+N Multi-Module System One-Line (250-750kVA)
Distributed Static Switch
Configuration Options AC Input
AC Input
Single-Module Configuration (250-750kVA models) Rectifier Bypass Rectifier Bypass
AC Input
Rectifier AC Input
Bypass AC Input
Rectifier AC Input
Bypass
Single-module systems provide a basic protection AC Input AC Input AC Input AC Input

configuration. Rectifier Rectifier


Rectifier Rectifier
The critical bus is powered by a single UPS system
System
with bypass capability. Static Static
Bypass
System
StaticSwitch StaticSwitch
Breaker
Bypass
Switch Switch
1+N Parallel Configuration (250-750kVA models) Battery Battery
Breaker

Battery Inverter Battery Inverter


Paralleling of single UPS units, offers easy scalability for Inverter Inverter

increased capacity or redundancy


Each unit has its own static switch for bypass
Provides redundant capacity without the need for a
system control cabinet UPS Output AC Output
Breaker
UPS Output To Load
AC Output
Breaker
N+1 Parallel Configuration (500-750kVA models) To Load

Paralleling of Multi Module units, without built-in static Liebert NXL N+1 Multi-Module System One-Line (500-750 kVA)
Centralized Static Switch
switch
AC Input
 equires System Control Cabinet with centralized
R
static switch Rectifier Rectifier Bypass
AC Input
System Control Cabinet can be easily integrated into AC Input AC Input

any switchgear solution Rectifier Rectifier

System rated static switch with bypass breaker offers


Static System
high
Bypassfault clearing capability, and high availability Switch Bypass
Output Breaker
Centralized monitoring allows good visibility and
Inverter Battery Battery
easy control of total system
Inverter Inverter
UCritical
p toBus six units may be used together for capacity/
redundancy
AC Output

UPS Output AC Output


Breaker To Load

35
Liebert Series 610 On-Line 610 UPS:
225-1000 kVA, 3-phase

Ultimate reliability for large-scale, Other Features Include:


mission critical applications. Higher DC bus utilization provides higher AC/AC and
DC/AC efficiency and allows a relatively smaller battery.
Offering the ultimate in power protection efficiency Continuous improvement dramatically improves
and reliability for larger facilities, Liebert Series 610 reliability by reducing the number of parts—and the
potential points of failure within the system.
UPS systems are available in a wide range of capacities
Lower operating costs and long life thanks to 93%
from 225 kVA to 1000 kVA. These systems are
operating efficiency and an industry leading power
designed to protect mission-critical operations from factor of greater than 0.92 for all models.
the full range of power quality problems and outages. The ability to handle unbalanced and 100%
non-linear loads.
Efficient IGBT (insulated gate bipolar transistor)
Lower heat output eliminates the need for complex
technology is combined with pulse width modulation/
air cooling arrangements.
stepwave topology to provide reliable operation Robust inverter manages overloads and faults without
and create a unit that packs more capacity into a the need for a static switch on the system output.
smaller footprint. Designed for intuitive, menu-driven operation, a large
backlit LCD operator interface displays system controls,
Thanks to all-digital controls and a unique inverter full-featured monitoring and alarm notifications.
topology, the Series 610 can be applied in several
single-bus configurations, including single module,
parallel redundant and isolated redundant systems.
For added reliability, multiple units can be utilized in
a dual-bus system with two power feeds to provide
redundancy during normal operation, as well as
continuous, shutdown-free operation when service
is required.

Liebert Power Monitoring Capabilities

The operation of the Liebert Series 610 UPS can be


monitored using:
Liebert MultiLink® Automated System Shutdown Software.
Liebert Nform™ Monitoring System.
Liebert SiteScan® Web Centralized Monitoring System.
Liebert Universal Monitor and Remote Power Monitor Panels.
Third-Party Monitoring Systems.

Liebert BDS-40 Battery Monitoring Alber

Technology By Liebert.

For more information, see pages 52 and 53.

36
Liebert NXL, Liebert Series 610
System Control Cabinet - SCC

When paralleling two or more units, a system control cabinet Each SCC includes:

Enterprise UPS
monitors the output of the UPS’s and assures that all of Microprocessor-based monitoring with backlit LCD
display, controls.
the outputs are synchronized. The System Control Cabinet
Momentary-duty static switch.
also contains a static bypass switch which assists in the Continuous duty static switch options
maintenance of the system. with custom switchgear.
Automatic system isolation and bypass breakers.
System Control Cabinets are integrated into
Automatic equalize charge timer.
the switchgear of your choice.
Interface for a remote power off.
Centralized monitoring controls allow Liebert SiteScan® Web interface.
for greater visibility into the system. Alarm status contacts.
Liebert SCC’s 610 contains a static bypass switch RS-232 port.
with manually operated disconnects and two Visual/audible alarms.
motor operated system circuit breakers.
Standard and custom power distribution switchgear
systems are available for use in Tier 1 through Tier 4 UPS
system configurations.

37
Liebert Trinergy, Multi-Modal On-line UPS:
200 kVA - 3.2 MVA, 3-phase

The Liebert Trinergy multi-modal on-line UPS from


Emerson Network Power is the only system of its
kind to offer three modes of operation, providing the
industry’s highest levels of efficiency and reliability.
It also offers the widest range of modular growth to
meet future requirements — start at 400kVA and grow
up to 3.2MVA.

Liebert Trinergy UPS has the highest level of flexibility,


energy efficiency and adaptability of any product in its
range. This transformer-free, modular, multi-modal
on-line UPS supports high power data center loads
with up to 99% energy efficiency depending on
incoming
power quality.

Liebert Trinergy Combines High


Efficiency With Lower CAPEX Higher Efficiency — Means Lower OPEX
Liebert Trinergy UPS design features greatly The unique architecture and technology of Liebert Trinergy UPS was developed
minimize the total cost of ownership in every stage to enhance efficiency. Able to recognize specific power quality conditions
of installation from preparation to startup. and respond appropriately to each disturbance, Liebert Trinergy UPS delivers
maximum energy savings while providing the best output power quality and
Installation Efficiency — The 415V structure and
conditioning to the load and the source. This provides significant operating
modular architecture of the Liebert Trinergy
savings with up to 99% efficiency and reduced requirements for power and air
UPS allow for cost-effective installation , and the
conditioning.
incremental addition of capacity as load increases,
permitting the user to conserve capital until The revolutionary architecture comes from incorporating the three industry
additional capacity is required thanks to lower standard functioning configurations for the first time in one high power UPS,
costs for installation and materials, reduced size of controlled by an energy optimizing algorithm:
electrical infrastructure and reduced cabling
Maximum Power Control (Double Conversion/VFI) — Provides the highest
Reduced Infrastructure Size And Operating Costs level of power conditioning and protects the load from all electrical network
— The extremely high efficiency achieved with disturbances.
Liebert Trinergy UPS reduces the energy dissipated Maximum Energy Saving (Standby/VFD) — Detects when conditioning is not
by the UPS (kW), thus minimizing the demand and required and allows the energy flow to pass through the bypass line.
consumption of the air conditioning system.
High Effciency and Power Conditioning (Line-Interactive/VI) — Compensates
Circular Redundancy — The Liebert Trinergy UPS the load THDi, PF and main sags and swells.
system’s circular redundancy feature adjusts The Liebert Trinergy UPS has the ability to choose the most efficient operating
available UPS capacity to meet immediate load mode based on different electrical conditions which ensures that the supply
and redundancy requirements by automatically to the load remains optimal at all times. This allows the UPS to achieve
switching excess module capacity to standby, thus extraordinary energy savings, first class performance and
greatly improving efficiency at partial load and maximum power protection.
reducing operating costs.

38
Three Dimensional Modularity User Interface

Enterprise UPS
With three dimensions of modularity — Vertical, Horizontal and Orthogonal
— Liebert Trinergy UPS allows businesses to expand their power protection
needs at the same pace as their evolving load requirements by simply
adding additional power modules. Modules can be added at anytime during
the lifecycle of the UPS, allowing it to reach up to 3.2MVAv .

Vertical modularity — The stacked core assemblies in each core module


may be individually extracted for service purposes while the UPS system
continues to protect your load.
Horizontal modularity — Trinergy can scale up to 400 kVA arrays by
adding complete 200 kVA power modules around the input/output
power section.
Local monitoring of the Liebert Trinergy UPS is
Orthogonal modularity — The ability to work with up to 8 complete provided by an on-unit LCD touch screen:
arrays in parallel — up to 3.2MVA.
High security access with separate password

Liebert Trinergy UPS


levels for users and service engineers.
User-friendly graphical interface.
Single-line mimic diagram for system status
Contemporary dashboard-style indicators for
major system values and conditions
Module level alerts for all major subsystems
including rectifier, inverter, batteries, static
switch and bypass
System voltages and power
Load vs. capacity indicator
System temperature gauge
Battery charge indicator

Liebert Power Monitoring Capabilities

The operation of the Liebert Trinergy UPS can be


monitored using:
Liebert MultiLink® Automated System Shutdown
Software.
Liebert Nform Monitoring System.
Liebert SiteScan® Web Centralized Monitoring System.
Liebert Universal Monitor And Remote Power Monitor
200 kW Power Core
Panels.
I/O Cabinet
Third-Party Monitoring Systems.
200 kW Power Core
Albér Battery Monitoring.
For more information, see pages 52 and 53.

39
Liebert FDC
Rack Power Distribution

Power When And Where Rack Sized Power


Distribution Cabinet
You Need It
Producing quality power is the first step—getting it to As your rack-based systems
grow in number, complexity
critical equipment in the most efficient manner while
and criticality—so must your
maintaining proper voltages and other key parameters is power distribution system. To
the important next step. meet this challenge Liebert has
created a product designed to
Making Sure The Power Is Always There optimize power distribution at
When You Need It the rack level with the “plug
Liebert’s range of power distribution equipment is and play” flexibility that today’s
specially designed for high-availability applications. IT managers demand from their
It includes both distribution and switching systems systems.
to provide reliable power to critical loads.
The Liebert FDC distribution
cabinet extends the
Liebert Power Distribution
functionality of the PDU by
Solutions Are Ideal For:
packaging 168 poles in a
Large-Scale Computer Centers.
stand-alone cabinet with a
Facility-Wide Networks.
rack foot print.
Large-Scale Telecommunications Centers
Colocation Facilities.
Internet Data Centers.
Server Farms.
Data Warehouses.
Network Management Centers.
Medical Imaging Equipment.
Test and Laboratory Facilities.
Industrial Process Control Operations.
The Standard Liebert FDC Unit Optional Features Include:
Includes: Top cable exit.
4 complete panelboards with main LDM monitoring with remote
breaker (total 168 poles). communications—Modbus output.
Front and rear access only. Isolated ground bus bars.
Bottom cable exit. EZ-view doors enable visual
22kAIC main panelboard breakers. inspection of the breakers
without unlocking the cabinet.
Square D or GE inline panelboards
in bolt-in or plug-in styles.
Current monitoring panel.
Tie-breakers to allow connection
of two panelboards to a common
panelboard main breaker (requires
side access).
Plug-in main panelboard breakers.

40
Liebert RDC Remote Distribution Cabinet

The Better Way To Wire High Density Facilities

Power Distribution Systems


The influx of client/server rack equipment is changing the content of data
centers. There are more devices than before—and they consume less power
than their predecessors. As a result, most power distribution units (PDUs)
run out of circuit breaker poles before they run out of rated capacity.

The Liebert Remote Distribution Cabinet (RDC) extends the functionality of


the PDU by packaging 168 poles (four complete 42-pole inline panelboards)
in a stand-alone cabinet.

Unlike standard Liebert Precision Power Centers (PPCs), the RDC has no
internal isolation transformer and requires 4-wire-plus-ground input from
a PPC or other transformer. By separating the PPC transformer from the
panelboard function, Liebert was able to create an extremely compact
package that fits the area of a standard 24” x 24” raised-floor tile.

The individual panelboards inside the Liebert Remote Distribution Cabinet


can receive power from different sources. This enables the RDC to provide
fault-tolerant, fully maintainable dual-bus power to nearby load equipment.
A dual-input RDC can be configured with two panelboards on each side
sharing common input terminals.

Other Features Of The Liebert RDC:


Unobstructed wiring access for easy of installation.
Complete isolation and maintainability.
Optional clear door insert panels enabling visual inspection
of the breakers without unlocking the cabinet.
Optional adjustable accent panels to make it easier to
compensate for breaker “creep”.
Single, dual or four-input configurations.
Optional current monitoring panel.
Optional input junction box and underfloor conduit box.
UL labeled.

Conduit-landing plate, Liebert Power Monitoring Capabilities


left, is positioned for
easy cable access. The operation of the Liebert FDC and Liebert RDC
can be monitored using:
Liebert SiteScan® Web Centralized Monitoring System.

For more information, see pages 52 and 53.

41
Liebert FPC Rack-sized Power Conditioning
and Distribution Cabinet

Optimized For Row-based Applications. Other Standard Features Of The Liebert FPC:
Computer-grade grounding.
The Liebert FPC power conditioning and distribution cabinet provides Fully compatible with the non-linear loads.
higher quality, more flexible power distribution for high-density
Main input breaker with shunt trip.
data centers. It is engineered to combine the convenience and cost
Double-shielded TP1 listed isolation transformer.*
savings of a pre-packaged, factory-tested unit with the flexibility of a
custom-tailored power system. This self-contained system provides One or more individually enclosed 42-pole output
power isolation, power distribution, computer-grade grounding and panelboards.
power monitoring. Built-in metering and alarm annunciation with
communication to Liebert centralized monitoring.
Ranging in capacity from 15kVA up to 300kVA, the Liebert FPC comes Compact single cabinet conserves valuable floor space.
in a 19” rack and 47” wide rack, the size of two 19” racks, and is Single input cable connection reduces installation time
designed to fit at the end of, or within, a row of racks, as well as in a and cost.
stand-alone configuration. Full front and rear access.
Can be easily relocated to protect your investment.
The packaged system approach of the Liebert FPC is convenient
UL and ULc Listed as a complete system.
and space-saving, reducing installation time and cost compared to a
conventional approach using multiple interconnected components. *Energy Policy Act of 2005 requires that all “distribution transformers”
and all “low-voltage dry-type distribution transformer” manufacturers
produce only TP-1 units as of January 1, 2007. TP-1 transformers have
a higher efficiency than standard isolation transformers, and are
optimized to have the highest efficiency at 35% load.

42
Liebert PPC Packaged Power Conditioning
and Distribution

Optimized For Room-Based Applications.

Power Distribution Systems


Liebert Precision Power Center
The Liebert Precision Power Center (PPC) power
conditioning and distribution cabinet is designed
to bring you a distribution system that offers the
benefits of a custom-tailored power system, with
the convenience and cost savings of a pre-packaged,
factory-tested unit. Housed in a single, self-contained
cabinet, it combines distribution, computer-grade
grounding, isolation, and power monitoring to provide
the protection your vital computer or communications
equipment demands. Available in 15-800 kVA capacity
systems for raised floor applications and 15-150 kVA
capacities in top-exit models for non-raised floors, the
Liebert PPC offers flexible expansion capabilities to fit
growing sites.

The packaged system concept of the Liebert PPC is


convenient and space-saving, reducing installation time
and cost compared to a conventional approach using
multiple interconnected components.

Other Standard Features Of The Liebert PPC:


Secure distribution and circuit identification.
Non-linear load compatibility.
Individual circuit breaker protection.
Built-in metering and alarm annunciation, with
communication to Liebert-centralized
monitoring systems.
Double-shielded TP-1 listed isolation transformer.* Liebert Power Monitoring Capabilities

Easy installation, with single input cable connection The operation of the Liebert Precision Power
and application matched connections to the load. Center and Liebert FPC can be monitored using:
Expandable with add-on panelboards Liebert Nform™ Monitoring System.
Liebert
SiteScan® Web Centralized
and flexible cabling.
Monitoring System.
Flexibility to protect your investment by allowing
Third-Party Monitoring Systems.
the unit to be easily relocated.
UL and CSA Listed as a complete system. For more information, see pages 52 and 53.

*Energy Policy Act of 2005 requires that all “distribution transformers”


and all “low-voltage dry-type distribution transformer” manufacturers
produce only TP-1 units as of January 1, 2007. TP-1 transformers have
a higher efficiency than standard isolation transformers, and are
optimized to have the highest efficiency at 35% load.

43
Easy-To-Use Color
Touch-Screen Interface
The controls of the Liebert STS2 are
intuitive and simple. The pop-up menus
are easy to understand and provide a
wealth of operational and diagnostic
information.

The color LCD monitor is divided into


three segments. In addition to a system
mimic diagram, there is a status/
alarm panel and a section dedicated
to operator instructions and menus.
You benefit from improved operator
effectiveness, reduced training time,
Liebert STS2 Static Transfer Switch and less chance of operator error.

The Key To High-Availability Power.

The Liebert STS2 Static Transfer Switch provides an


automatic, seamless transfer between the outputs of two
independent UPS systems and the input of a critical load in
a dual-bus power system. If the primary UPS should fail, the
switch will automatically transfer the loads to the surviving
UPS. For redundancy, the Liebert STS2 features three
separate, self-correcting logic modules. Each controller is
capable of working independently and each helps monitor
the other two. Available in capacities ranging from 100 up
to 1000 amps.

True Front-Access Design


All mechanical and electronic components of the
Liebert STS2 are accessible from the front of the unit. This
gives you several immediate benefits:
Greater freedom in system design. The Liebert STS2 can
be placed adjacent to or in back of other equipment. It
can also be placed against a wall or partition.
Simplified installation, with ample space for cable
connections through top and bottom access plates.
Less floor space required for maintenance access.
Simplified maintenance, with all key components
visible, serviceable and removable from the front of
the unit, without the need to shut down the connected
load.

Other Features Of The Liebert STS2: True Internal Redundancy


Internal CANBUS protocol provides high-bandwidth The Liebert STS2 has triple-redundant logic. Each DSP
communication between system components via controller is capable of working independently, and
twisted-pair cables. Options can be added as simple each helps monitor the other two. If one malfunctions,
network nodes. the other two lock it out. Each controller has power
Internal dual-bus control power. feeds from both power supplies.
Simplified installation and maintenance.
The two power supplies feature true dual-bus power
Full range of communications options to fit any
distribution. Both have dual inputs, one from each
monitoring strategy. AC input source. All power connections have diode
Three-pole switch configurations. protection, so that internal or external faults cannot
Optimized Transfer option uses the patented Liebert propagate. The result is a rugged, fault-resilient
static transfer control algorithm to eliminate downstream package that is optimized for real-world applications.
transformer inrush saturation. Meets CBEMA and ITIC
standard for critical loads.

44
Liebert STS2/PDU Static Transfer Switch/
Power Distribution Unit

Combines Power Distribution And Automatic Switching. Features Of The Liebert STS2/PDU Include:

Power Distribution Systems


True dual-bus power distribution switches
With a single, space-saving unit, the Liebert STS2 Static Transfer automatically or manually between two
Switch/Power Distribution Unit combines the switching capabilities AC power sources.
of the STS2 with the benefits of a proven power distribution unit. Computer-grade grounding automatically establishes
Liebert designed the STS2/PDU to bring you a distribution system a single point ground to meet major manufacturers’
that will close the power delivery loop in your critical facility. It recommendations and the requirements of the
offers the benefits of a custom-tailored power system, with the National Electric Code.
convenience and cost savings of a pre-packaged, factory-tested unit. Fully compatible with the non-linear loads
of modern computer systems and other
Housed in a single, self-contained cabinet, it combines distribution, electronic equipment.
computer-grade grounding, isolation, and power monitoring, as Built-in metering and alarm annunciation with
well as dual-source switching, to provide the protection your vital communication to Liebert SiteScan® Web centralized
computer or communications equipment demands. monitoring.
Compact single cabinet conserves valuable floorspace
Available in capacities from 250 to 800 amps, the Liebert STS2/
compared to non-packaged solutions.
PDU offers flexible expansion capabilities to fit growing sites. The
Single cabinet design reduces installation
packaged system approach of the Liebert STS2/PDU is convenient
time and cost.
and space-saving, reducing installation time and cost compared to a
The unit can be easily relocated to protect your
conventional approach using multiple interconnected components.
investment.
UL Listed as a Complete System to meet safety
requirements for fast, hassle-free inspection and
building code approvals.
A choice of distribution options to fit site
requirements.

Liebert Power Monitoring Capabilities

The operation of the Liebert STS2 and Liebert


STS2/PDU can be monitored using:

Liebert Nform™ Monitoring System.


Liebert
SiteScan® Web Centralized
Monitoring System.
Liebert Universal Monitor and Remote

Power Monitor Panels.


Third-Party Monitoring Systems.
For more information, see pages 52 and 53.

45
Liebert Power Systems Test Center

The Liebert Power Test Center for large Test Capacity and Performance of Liebert Power Solutions
UPS systems is a state-of-the-art test The Liebert Power Test Center for large UPS systems consists of multiple test
facility designed to provide customers with stations in each of seven test bays. Testing is customized based on the complexity,
pre-installation testing of the performance, size and number of UPS components in the configuration, but always includes
interoperability, and efficiency of Liebert analysis of every module as well as the entire system. Module and system tests
power modules and systems under a variety include:
of conditions. Located in Delaware, Ohio, the
Steady-state — 0% to 100% plus overload, unbalanced loading; non-linear loading
41,000 square-foot facility, including a 2,600
Dynamic — 0% to 100% step loads plus overload, unbalanced loading; non-linear
square-foot customer observation suite, is loading
the largest and most comprehensive in the Overload and faults — (>100%, 125%, 150%)
industry. Plus other customer-specified special test requirements.

Testing includes individual UPS modules as Testing on large Liebert UPS systems, may include UPS power modules, input and
well as the complete power system—including output switchgear, power distribution units, static transfer switches, and battery
large UPS units such as the Liebert NXL UPS cabinets.
and associated switchgear and ancillary
Test results certify the input and output, AC and DC characteristics of the system.
products—and is essential to the smooth,
Performance comparisons against specifications include, but are not limited to:
rapid installation and commissioning of large
power systems. Customers leave the Liebert Voltage and waveform
Voltage regulation
Power Test Center with documented test
Voltage and current harmonics
results and confidence that their complex
Frequency
power system will operate seamlessly and in
Current and waveform
accordance with business-critical availability
I/O power factor
requirements.
Efficiency based on kW in and out
System switching, control and monitoring functionality

46
Enterprise UPS
Factory Witness Testing: View the Entire Testing Process Benefits of Power System Testing:
Factory Witness testing for large UPS systems is usually conducted over a Provides complete pre-installation testing of large
period of multiple days. During testing, customers and consulting engineers UPS systems and associated support equipment.
Tests the performance, interoperability and
may oversee the entire process from the Power Test Center observation suite
efficiency of critical power systems.
that overlooks the test bays or in the specific test bay itself. Multiple LCD
Assures rapid installation and commissioning of
panels offer easy access to real-time test data, including waveforms, testing
large UPS power systems.
procedures and results. Once testing is completed, a report of the results is Confirms the functionality of all subsystems.
provided. Allows customers to document performance of
multi-module UPS systems prior to installation.
The Liebert Power Test Center features seven test bays, each containing
Optimizes the testing process with the use of the
multiple test stations, where module and complete system analysis is
latest agency standards.
conducted in full view of the customer.

Liebert Power Test Center Features:


Seven test bays, each containing multiple distinct test stations.
Power test viewing suite overlooking test bays and equipped with LCD panel
displays that offer easy access to relevant test data.
Results are provided at the conclusion of each test.
All I/O circuit breakers can be remotely controlled.
Voltage, current, frequency and watts monitored on all I/O circuit breakers.
Total power of >12 MW available via the facility utilities.
Higher capacities supported through a 1.75 MVA, 750 kVA, and 350 kVA
50/60 Hz engine generator as well as plug-ins for additional generators.

47
Power Quality Solutions High Quality Surge Protection

For applications requiring protection from electrical line problems without the These Products Include:
need for back-up capability, Liebert manufactures a full line of surge suppression
and power conditioning equipment.
High Exposure Systems
The Best Possible Power
Liebert’s wide range of Surge Protective Devices, (SPDs) have numerous Liebert SI Series (Interceptor II)—Built to
applications throughout a facility, including protection against transients provide the highest level of surge current
that are generated by other equipment within the building. Our power capacity, with the lowest clamping voltages.
Along with true NEMA 4 assembly suitable for
conditioning systems shield critical loads from external disturbances,
outdoor use.
particularly those coming through the utility power line.

Liebert Power Protection Solutions Are Ideal For: Liebert LM Series—Offers continuous
Computer Centers. Network Management Centers. protection from damaging transients and
electrical line noise. Surge suppression levels
Facility-Wide Networks. Medical Imaging Equipment. range from 120 kA to 500 kA per phase.
Telecommunications Centers. Test And Laboratory Facilities.
Colocation Facilities. Industrial Operations.
Internet Data Centers.
Liebert ACV Series (AccuVar)—A full line
of multi-phase, multi-mode distribution
panel-mounted surge suppression devices.

Liebert SH Series (Hybrid) - Liebert SH


Series (Hybrid) is the first hybrid product
in the industry to offer a true coordinated
multi-stage system of suppression.
Integrating the fast response time of the SAD
(Silicon Avalanche Diode) module with the
high-energy capability of the standard Liebert
Interceptor MOV (Metal Oxide Varistor)
modules. Surge current capacity ranges from
250 kA to 750 kA per phase.

Liebert ATF Series (Active Tracking Filter™)—


A customized, modular approach to surge
protection in a series filter device.

Liebert SS Series—Approved by Motorola


R56 Committee, Standards and Guidelines for
Communication Sites—Type 1 and 2 Devices.
Utilizes advanced SAD/MOV array technology
for industry leading transient suppression
voltages.

Liebert LPGE Series—An add-on device for


integration with panelboards at the jobsite for
enhanced surge suppression. Surge current
capacity levels range from 130 kA to 200 kA
per phase.

48
Emerson Network Power manufactures the industry’s Installing protection at the electrical service entrance,
widest range of Surge Protective Devices (SPDs). These distribution points, branch panelboards and on specific
SPDs are ideal for small facilities, large equipment sensitive loads or equipment throughout your facility
rooms or entire buildings, plus a wide range of power, is the best way to prevent damage and eliminate
control and data line applications. Each surge protection associated downtime to sensitive microprocessor-based
product features the rugged reliability that has been the electronics.
Liebert trademark for more than 40 years.

Surge Protection And Power Conditioning Systems


Home and Office Protection Data/Signal Line Protection

Islatrol™ SP-6TVN Series—The Islatrol Edco RM-CAT6 Series—Includes 16 and


SP-6TVN is a surge suppressor/filtering 48-channel high-speed data line protectors
device that features uniquely designed that utilize three-stage hybrid technology.
repositionable outlets and protects sensitive These units address high-energy voltage
home/office equipment including home transients that can damage expensive
theaters, satellite dishes, computers, network equipment. Ideal for network
printers and faxes. patch panels, switches and hubs, these
units mount easily in the same racks as the
equipment they are protecting.

Medium & Low Edco PC642 Series—The Edco PC642 Series


Exposure Systems surge suppressor is a two-pair (four-wire)
module implementing three-stage hybrid
PowerSure LPL & LPM Series—surge technology. This module addresses
suppression systems protect connected over-voltage transients with gas tubes and
equipment against electric power line silicon avalanche components.
disturbances and transients in medium and
low exposure locations. Displays LED status
indication. Provides remote indication Edco LCDP Series—The Edco LCDP Series
capabilities. is designed to conveniently protect 8 wire,
low voltage data circuits and employs two
RJ-45 jacks for easy installation.

Islatrol ™ RM Series—This line of AC surge


protectors is ideal for protecting the power Edco RJA-RJD Series—The Edco
feeding valuable rack equipment. This series RJA and Edco RJD Series are four pair
provides 40,000 Amps of surge protection telephone/data line protectors that
and up to 60 dB of high- frequency noise implement advanced two stage
filtering. hybrid design.

Edco CAT6-5 POE Series—The Edco


CAT6-POE Series is designed to work
on Category 5 Power-Over-Ethernet
transmission lines as well as CAT 6
applications.

Edco PHC Series—This surge suppressor


is designed to protect two pairs of wires
specifically for alarm and security systems
where operating currents can be as high
as 5 Amps. It utilizes three-stage hybrid
technology to address overvoltage
transients and sneak and fault current
for signaling circuits.

49
Powerful Solutions
For Critical Data And Telecom Applications
From major switching and data centers to remote shelters and computer
rooms, Emerson Network Power -48V DC power systems have the features and
proven performance to match your network application needs.

Visit: EmersonNetworkPower.com/DCPower

NetSure® ITM Features DC UPS


High system efficiency: Reduced 400/480V AC 3-Phase Input
end-to-end power conversion stages Integrates AC to DC power conversion,
combined with efficient power battery backup and branch
conversion units (PCUs) and an
distribution into a compact, highly
advanced energy optimization mode
enable significant energy savings even
reliable power protection system for
at low loads. data center applications.
Scalability and ease of deployment: NetSure® ITM
Minimize your initial investment and The NetSure® ITM lowers the cost of
avoid stranded power by adding data center design, operation and
expansion DC UPS modules without
management. This 48V direct current
interruption in the field as power needs
increase. solution is a row-based DC UPS that
delivers simple, scalable and highly
DC architecture simplicity: Fewer
efficient power protection in 70kW
components, conversion stages and
distribution breakers throughout modules. Up to four DC UPS modules
the power chain ensure high can be installed together for 280kW of
availability; elimination of complex total power.
synchronization circuits and the need to
de-rate capacity for phase balancing or The NetSure® ITM is deployed directly
harmonics makes it easy to engineer. on the server room floor, providing
Energy Optimization Mode
protected 48V power to nearby
Intelligent Power Matching equipment racks. This preserves the
Achieves near-peak UPS efficiency efficiency and reliability benefits of
down to 5% system load by optimizing DC power, minimizes the amount of NetSure® ITM 140kW, Two Module System
individual PCU performance, greatly copper required, and enables modular
reducing energy costs over time in
growth.
real world conditions

NetSure® rectifiers or power conversion units (PCUs) convert 3 phase 400/480V AC to


-48V DC and are the heart of the NetSure® ITM. Each DC UPS module includes twelve
independent 5.8kW PCUs. Each DC UPS module is factory integrated with distribution
and battery backup. 48V branch distribution via 22 circuit breakers (6 fuses optional);
5-10 minutes of battery backup is provided across three parallel 48V battery strings.

48V DC Rack Power Distribution


NetSure® RDB Series
Deploy DC power in your rack with zero U, rear mount power distribution units (PDUs)
to maximize rack space available for revenue generating equipment. Featuring plug-
and-play connectors for simple field operation, NetSure® RDB 48V Rack Distribution
Units are designed for ultimate ease of use.
With a maximum load capacity of 8.4 kW for each PDU and various output breaker sizes
available, the NetSure® RDB Series is provisioned to optimize the wire size required to
each device. This allows for easy pre-configuration and management as no special tools
are required to maintain or move IT equipment.

50
50
As the next step in the evolution of the
NetSure® DC Power platform, eSure™ high-efficiency rectifiers
from Emerson offer superior performance and uncompromised
reliability, delivering efficiency levels near 97%.
eSure™ technology delivers Efficiency Without Compromise™.


Large DC Power Systems Small DC Power Systems

DC Power Systems
208/480VAC 3-Phase Input 120 / 240VAC Single Phase Input
Power systems for data center and central office Highly reliable, uninterruptible and cost-effective power systems
applications, including wireline and wireless switching, for small data or telecom installations.
transmission, data routing and large telecom hotels.
NetSure® 502
The NetSure® 502 is a flexible system
capable of providing DC power through
the use of 2000W standard or high-
efficiency eSure™ rectifiers, an SCU+
controller, and a variety of outputdistribution options.

Mini DC Power Systems


120 VAC or 220/240VAC Single Feed Input
High-density mini-sized DC power solutions for outside plant
enclosure, central office or embedded applications.
NetSure® 211
This DC power solution offers 1RU and
NetSure® 801 NetSure® 802 2RU configurations, combining reliable
The NetSure® 801 high- Integrated -48VDC 3-phase NetSure® rectifiers with an advanced
density power system offers rectifiers, distribution, control Ethernet-accessible controller for mini power applications.
the increased flexibility of a and monitoring in a single
cabled plant in a centralized or frame. Expandable to 10,000 DC Power Distribution Equipment
distributed architecture. amps with additional frames.
Custom designed or standard enclosures available for all types
Medium DC Power Systems of data and telecom equipment.
240VAC Single Phase Input
Modular, flexible design for switching, wireless base stations, NetSure® 801 DB
transmission, LAN, WAN and other networking operations. Battery Distribution Fuse/
Circuit Breaker Bay featuring
high capacity, front access,
modularity, and simplified
installation to effectively
LORAIN® DB 48500 provide secondary load
This modular system distribution and protection
provides effective secondary for multiple -48 VDC feeds
load distribution for single or up to 600 amps.
multiple -48VDC feeds.
DC to AC Inverter Systems
120VAC and 230 VAC Single Phase Output
Ideal for a data center, wireless switching, or central office
environment where flexible expansion capabilities are required.
NetSure® 700 NetSure® 701 NetSure® 702
The NetSure® 700 Modular power Combines the
Enclosure Solutions
power system with system providing advantages of the Custom designed or standard enclosures available for all types of
2500 watt or 3000 up to 4,000 smaller 3200 watt data and telecom equipment.
watt rectifiers and amps of power at standard and high-
1500 watt converters -48VDC with 3200 efficiency eSure™ Batteries & Accessories
is a modular power watt standard or rectifiers from the Products frequently used together with DC power systems
system providing high-efficiency NetSure® 701 system
up to 4,000 amps of eSure™ rectifiers. with the controller including batteries, battery strands, battery trays, bus covers,
power at +24VDC and capability and plant assorted panels, circuit breakers and much more.
400 amps at -48VDC. architecture of the
NetSure® 801 system.

51
Power System Monitoring:
The Key To Continuous Operation

What You Don’t Know Can Hurt You. How Deep Does Your Monitoring
A small problem in a critical facility can quickly Need To Be?
escalate into a disaster—knowing what is happening Monitoring can range from a automated shutdown
with your power equipment, so you can keep that software that provides basic operating information
protective “envelope” at peak operating efficiency, from a single UPS unit, all the way to full-scale
is vital to system reliability. monitoring and control of a critical facility including
trending and data analysis.
Different People Need To Know
Different Things. Your requirements will vary according to the specificity
Liebert offers you more monitoring solutions than of the information you need. You may require no more
anyone else because getting the right information than a local readout of a unit’s operating status. Or you
about your power equipment to the right people, may need the ability to control its operation and
with the right level of urgency, is so important to receive alarms.
system availability.
These information requirements may also go beyond
We do this by allowing you to receive and use basic monitoring and control. You may need the ability
information from your Liebert power equipment’s to analyze performance data in order to pinpoint
microprocessor controls–no matter where it is located trouble spots so that the same problems don’t
or what communications protocol, operating platform happen again and again.
or building management system is being used.
In-band, out-of-band and web-based monitoring are
all available. From enterprise monitoring systems
to individual pieces of communications hardware,
you will know the exact problem so that you can
implement the right solution.

52
Maximizing Your Investment Through System Monitoring

Distributed Management with Centralized Management with Enterprise Management with

Monitoring And Control


Liebert IntelliSlot Interface Cards Liebert Nform®Software Liebert SiteScan® Web Software
For enhanced remote communications As business grows, your critical For customers who require extensive
and control of your Liebert units, equipment infrastructure will management of critical system
the Liebert IntelliSlot Web and 485 expand, thus the need for centralized equipment that may span multiple
Cards deliver the communication management of this equipment will be locations in an ever-moving global
capabilities you require. key to your business success. enterprise, Liebert SiteScan Web
will centrally manage your critical
Monitoring and control through your Connecting to equipment in the equipment and give you the power
existing Network with no additional distributed critical space is only part of to move beyond the event-responsive
software required. the monitoring challenge. service paradigm.
Each Liebert system equipped with a Liebert Nform leverages the Liebert SiteScan Web does it all:
Liebert IntelliSlot Web Card takes full network connectivity capabilities Real-Time Monitoring and Control.
advantage of your Ethernet network, of your Liebert equipment to provide
Event Management and Reporting.
allowing remote monitoring from your a centralized monitoring view of your
Data Analysis and Trending.
computer desktop, network operations distributed equipment.
center or wherever network access is Building Management Integration.
permitted, without the need for Utilizing the SNMP and Web
front-end software. technologies built into each of the Liebert SiteScan Web is a comprehensive
Liebert IntelliSlot communication cards, critical systems management solution
Monitoring integration with Liebert Nform will centrally manage dedicated to ensuring reliability through
your existing Building alarm notifications to provide you with graphics, event management and
Management System. an easy interface to access critical status data extrapolation. The standard Web
information. Liebert Nform puts critical interface allows users easy access from
A Liebert system equipped with a Liebert systems information at the fingertips of anywhere at anytime.
IntelliSlot™ 485 Card can be seamlessly support personnel—wherever they are— Single and multi-site applications.
integrated with your existing Building increasing responsiveness to Event management and unit control.
Management System. alarm-event conditions, thus allowing Trend and historical data captures
IT organizations to maximize their
and reporting.
system availability.
Full ASHRAE BACnet compatibility.
Java based.
Windows 2000, XP and 2003
compatible.

Liebert Nform
Liebert IntelliSlot Web

Liebert SiteScan Web

53
Liebert Services
Complete Start-Up And Preventive Maintenance Services

Peace of mind. It’s confidence you’ve done everything possible Confident Customers. Satisfied Customers.
to assure system uptime. It’s confidence the power systems You know them. They’re confident because they
know their systems will be available when they
you rely on are operating at peak performance. It’s confidence
need them. So, they’re satisfied customers—and,
you’ve selected the best partner available to bring you back they’re probably ours. 99% of our customers are
online in the event of unexpected downtime. satisfied with the service we provide. In fact, 96%
of them would recommend us to someone else
­­­­­­
Complete confidence. When it comes to selecting a (source: MRSI).
service organization to maintain your critical power
systems, you can only have complete confidence that Proprietary Tools Deliver Uptime
Emerson Network Power Liebert Services can deliver: Ensuring peak operating performance of your
equipment comes down to having knowledgeable
 Real uptime assurance. We have the proprietary Field Technicians in your facility with the most
tools, industry knowledge and robust service current tools available to do the job. Only Emerson
infrastructure to deliver real assurance that your Network Power Field Technicians have access to
systems will be available when you need them. the proprietary tools needed to ensure system
uptime—firmware upgrades, factory engineering
 Efficient downtime recovery. After all, if downtime
specifications, access to Liebert product and
strikes, you need a partner that can get you back
application engineers and R&D. No one else can
online quickly with intelligent answers, rapid service
bring this to your organization.
response and parts where and when you need them.

The Business Case For Regular Maintenance

60x Increase in MTBF Regular OEM preventive maintenance increases the mean
51x time between failures (MTBF).
50x
For instance, the mean time between failures for a system
Increase in 40x 37x that receives 1 annual PM is 10 times greater than a system
Mean Time that receives 0 PMs.
Between
30x
Failures1 By contrast, a system that receives 4 annual PMs, as
23x
opposed to 0 PMs, increases its duration between failures
20x
by 51 times.
10x
10x 1
Data is based on Mean Time Between Failure analysis for
1x three phase UPS systems (≥ 100kVA) with an Emerson
Network Power service agreement between 2002-2007.
0 1 2 3 4
Number of Annual Preventive Maintenance Visits

54
Servicing All Your Critical Power Equipment

Your investment in power equipment is worthless if you don’t maintain it.


Not even the best equipment can function properly unless it’s serviced with a
regular maintenance schedule.

Emerson Network Power services The Power Equipment


the complete spectrum of UPS, We Service Includes:
batteries and related power All UPS and Batteries.
Automatic Transfer Switch.
distribution equipment in your data
Static Transfer Switch.
center or in other critical facilities
System Control Cabinets.
where continuous availability of PDUs.
systems is essential. Bypass Cabinets.
Power Conditioning & Distribution.

Emerson Network Power’s Liebert Services Business


Your power equipment functions as a complete system. Shouldn’t your service provider?
Only Emerson Network Power has the expertise and experience to service your entire power
infrastructure and all its components—from utility to rack.

Automatic Static Remote


Transfer Transfer Distribution
Racks
Generator Switch TVSS SwitchGear UPS Batteries Switch Cabinet

Power Availability Power Protection Power Conversion/Distribution


Availability depends Raw utility power Converting and delivering power
on the continuity of may be unsuitable for throughout a large facility or a
power and the ability sensitive technology small space is an important step
of an uninterruptible systems. In these in protecting availability.
electrical supply to ride situations, surge
through outages of suppression and
any duration. power conditioning
can deliver the power
quality you need.

55
Ensuring The High Availability Of
Mission-Critical Data And Applications.

Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader Emerson Network Power
Liebert Corporation
in enabling Business- Critical Continuity™ from grid to chip for telecommunication World Headquarters
1050 Dearborn Drive
networks, data centers, health care and industrial facilities. Emerson Network Power P.O. Box 29186
provides innovative solutions and expertise in areas including AC and DC power and Columbus, Ohio 43229
United States Of America
precision cooling systems, embedded computing and power, integrated racks and 800 877 9222 Phone (U.S. & Canada Only)
614 888 0246 Phone (Outside U.S.)
enclosures, power switching and controls, monitoring, and connectivity. All solutions 614 841 6022 FAX

are supported globally by local Emerson Network Power service technicians. Liebert Emerson Network Power
AC power, precision cooling and monitoring products and services from Emerson European Headquarters
Via Leonardo Da Vinci 8
Network Power deliver Efficiency Without Compromise™ by helping customers Zona Industriale Tognana
35028 Piove Di Sacco (PD)
optimize their data center infrastructure to reduce costs and deliver high availability. Italy
39 049 9719 111 Phone
39 049 5841 257 FAX

Emerson Network Power Asia Pacific


29/F, The Orient Square Building
F. Ortigas Jr. Road, Ortigas Center
Pasig City 1605
Philippines
+63 2 687 6615
+63 2 730 9572 FAX

liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)

While every precaution has been taken to ensure accuracy and


completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.

© 2011 Liebert Corporation. All rights reserved throughout


the world. Specifications subject to change without notice.

All names referred to are trademarks or registered trademarks


of their respective owners.

® Liebert is a registered trademark of the Liebert Corporation.

SL-70100 (R06/11) Printed in USA

Emerson Network Power. EmersonNetworkPower.com


The global leader in enabling Business-Critical Continuity™.