Professional Documents
Culture Documents
Aspen Tech Compressor Modeling in Aspen
Aspen Tech Compressor Modeling in Aspen
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved.11-7738-0715
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Setting up a Steady-State Compressor Model in Aspen HYSYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Preparing a Dynamic Model from a Steady-State Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Adding and Plotting Compressor Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Modifying the Surge Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Dynamic Modeling of Compressor Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Conclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
Introduction
Compressors, generally used to increase the pressure of a gas, are an integral part of many production processes in the
oil and gas, energy, and chemicals industries. They are highly specific to each process for which they are designed. As a
result, they are mostly custom manufactured, expensive, and difficult to replace.
Compressors operate with very fast dynamics. Even a slight disturbance to a process’s steady-state could lead to a
compressor surge, which is the point at which a centrifugal compressor cannot add enough energy to overcome the
system’s backpressure. A compressor surge can lead to the unit malfunctioning, including rapid flow reversals and
changes in axial thrust, high vibration, and damage to rotor seals and bearings, which could necessitate equipment
replacement. Additionally, a surge is dangerous for individuals working near the compressor and can lead to a process
becoming hazardous, especially if process gas is released to the surrounding atmosphere.
To combat compressor surge, specialized control systems are designed and implemented into processes. Control
systems are enacted to maintain fluid flow to the compressor, which keeps the unit from surging.
Predicting which process conditions will cause the compressor unit to surge, and designing the subsequent control
scheme is a challenging, involved task. Aspen HYSYS Dynamics allows users to view the dynamic response of
compressors to changes in a steady-state simulation, as well as explore control strategies to best minimize the impact of
process disturbances to ensure smooth compressor operation.
Aspen HYSYS Dynamics provides performance charts to help the user visualize the process changes and compressor
performance. Tables can be inserted to the dynamic simulation to aid in the exact quantification of the changes in the
process.
In this Jump Start guide, analyzing the dynamic surge response of a compressor using Aspen HYSYS Dynamics will be
explored.
While this Jump Start guide will walk the reader through the process of using Aspen HYSYS dynamics to model
compressor performance, AspenTech recommends that a range of other resources be called upon in conjunction with
this document to give the user a comprehensive view of how to use Aspen HYSYS. These may include:
• AspenTech support website (support.aspentech.com) – this website has a wealth of information on the use of
AspenTech products and provides answers to frequently asked questions
• AspenTech courseware – available in on-line and in-person versions
• AspenTech business consultants
This document assumes that the user has Aspen HYSYS V8 or higher installed on his or her computer, and has
completed a functional process design.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
1
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
Before dynamic simulation can be initialized in Aspen HYSYS, a working steady-state simulation is required. Begin by
placing a compressor block onto an Aspen HYSYS flowsheet and attach an inlet, outlet, and energy stream. In order
to have a working steady-state simulation, the inlet stream into the compressor must be fully specified and either a
heat duty, the compressor’s pressure increase, or the compressor’s pressure ratio must be defined. To enter any of the
three compressor values, double click the compressor block on the flowsheet, go to the ‘’Parameters’’ section under
the compressor’s ‘’Design’’ tab, and then type a value in the appropriate box (Figure 1). In addition, choose whether the
compressor is centrifugal or reciprocating.
Having a converged, steady-state compressor model now enables continuation to dynamic simulation to view how the
compressor will respond under disturbance.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
2
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
For the remainder of this document, an example process containing a previously solved steady-state compressor will
be used. The file ‘’DYN COMPRESSOR MODEL SAMPLE.HSC’’ came attached to this guide and should be downloaded
and opened in Aspen HYSYS. The flowsheet for the process with dynamic control models from the example file is
shown in Figure 2. Compressor 23KA001 is connected to requisite process equipment—before reaching a Tee block to
model a recycle loop designed for surge protection for the compressor—whose flow is governed by VLV-100. The surge
protection loop is necessary to ensure that a continuous flow of fluid is provided to the compressor, should any process
perturbations disrupt normal steady-state operation. View any process specifics by opening a stream or process block
from the flowsheet.
The feed to the process in Figure 2 is contained inside a transfer function, TRF-1. In the model, a constant 1900 kmol/hr
of fluid is fed to the process when the transfer function is not activated. When activated, the feed is turned off, goes to 0
kmol/hr, and activates the surge protection loop.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
3
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
Figure 3. Setup Window for Addition of Compressor Curves, Including Completed Curves
Input compressor operating data, which is usually obtained from compressor manufacturers. Compressor curves plot the
head of the compressor unit versus a volumetric fluid flow at a constant compressor operating rate. The efficiency of the
compressor for a volumetric fluid flow can also be defined. Figure 4 displays an example of data for the compressor in the
simulation, operating at 4900 rpm.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
4
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
After all compressor curve data has been entered and an operating speed for the compressor has been designated,
return to the setup window for the compressor curves, and click ‘’Plot Curves…’’. A plot of the compressor curves for the
specified operating rates, as well as the current operating point for the steady-state compressor along the curves will be
displayed, shown in Figure 5. Additionally, a surge curve is displayed if the user enters the information. The surge curve
displays the boundaries past which the compressor would experience a surge in operation. Details on how to edit the
surge curve will be discussed in the following section.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
5
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
Note that this plot is a view of head versus flow at various compressor speeds. To view compressor efficiency versus flow,
choose the efficiency option under the ‘’Plot Type’’ grouping in the top right of the compressor plot window.
Clicking ‘’Surge Curve…’’ opens the following window in Figure 7. The compressor speed and/or the flow at which surge
occurs can be edited to either modify existing points or generate new points for the surge curve.
After ensuring that the compressor and surge curves are properly plotted, continue to the ‘’Inertia’’ section of the ‘’Rating’’
tab to update parameters pertaining to the inertia of the compressor impeller and shaft, Figure 8.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
6
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
Finally, continue to the Dynamics tab to edit the surge controller. Click ‘‘View Surge Controller…’’, shown below
in Figure 9.
This opens the surge controller window. Verify that the surge controller has the proper connections and objectives, and
then navigate to the ‘’Surge Control’’ option under the ‘’Parameters’’ tab. Here, the robustness of the surge controller can
be managed by varying the surge control parameters, as shown in Figure 10.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
7
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
Open the compressor curves plot, which should appear as it does in Figure 5. Then, double click the transfer function
block on the flowsheet and select the ‘’Face Plate…’’ option that appears in the subsequent window, displayed in Figure 11.
Note that the configuration and parameters for the transfer function used in the example simulation can also be seen in
this figure and can be used for reference for other simulations, if needed.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
8
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
The transfer function face plate will appear and display the current process value, as well as the current operating point,
shown in Figure 12.
Place both the transfer function face plate and the compressor curve plot on the simulation flowsheet for use in the
dynamic simulation.
Before running Aspen HYSYS Dynamics, note that the charts on the flowsheet for VLV-100, valve 23FE1015, the
compressor, and process stream 1 appear as follows:
VLV-100 23FE1015
Feed Pressure 1220 kPa Molar Flow 1900 kgmole/h
Product Pressure 200.2 kPa Pressure Drop 1.073 kPa
Molar Flow Feed Pressure
3.600e-012 kgmole/h 192.7 kPa
The flow through the surge control valve is essentially zero, indicating that there is no surge being experienced in the
compressor. This can be verified in the compressor curve plot. As a corollary, all 1900 kmol/hr of feed are flowing to the
compressor and exits through the splitter to stream 1. The compressor operates at the speed indicated on the compressor
curve plot.
To start the dynamic simulation of compressor behavior, click the ‘‘Dynamics’’ tab in the Aspen HYSYS ribbon, and then
click ‘’Run’’, shown in Figure 14 below.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
9
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
After clicking ‘’Run’’, the dynamic simulator begins collecting compressor flow, head, and efficiency performance data.
The transfer function block serves to provide the compressor a disturbance, which in turn, allows the user to see how the
compressor and its surge control loop will respond. To initiate the disturbance from the transfer function block, check the
‘’Active’’ box on the transfer function face plate, shown in Figure 15.
Figure 15. Transfer Function Face Plate with ‘’Active’’ Option Checked to Stop Feed to Process
For the simulation set up, clicking the ‘’Active’’ box completely stops the feed to the compressor. It can be observed
on the compressor curves plot that the compressor experiences surge when the feed is stopped, followed by the surge
protection control loop recycling fluid, which leaves the compressor back to the inlet in order to ensure continuous fluid
flow through the unit (Figure 16).
Figure 16. Compressor Curves Showing Surge Response and Control Response
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
10
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
When the surge control loop is activated, the compressor operates at a higher rpm, has a higher head, and passes a
higher flow. This is evident when comparing the tables at steady-state in Figure 13 to the updated tables after initiating
the feed disturbance, as shown below in Figure 17.
VLV-100 23FE1015
Feed Pressure 1220 kPa Molar Flow 2500 kgmole/h
Product Pressure 214.9 kPa Pressure Drop 1.207 kPa
Molar Flow Feed Pressure
2502 kgmole/h 206.4 kPa
Product ceases to leave the process in stream 1 after the surge control loop begins, while the flow through the surge
control valve, VLV-100, jumps from zero to 2500 kmol/hr. This then makes its way back to the compressor through
valve 25FE1015. An increase in compressor speed, capacity, and power can also be verified.
Unchecking the ‘’Active’’ box on the transfer function face plate restores the feed stream to the compressor to 1900
kmol/hr. Accordingly, compressor performance will return to the original, steady-state operating point. Figure 18 shows
the compressor curves plot after returning the feed stream.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
11
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
The compressor gradually returns to the steady-state performance it began with. The following results table shows the
key process variables for the compressor at the operating point shown in Figure 18.
VLV-100 23FE1015
Feed Pressure 1220 kPa Molar Flow 1900 kgmole/h
Product Pressure 200.4 kPa Pressure Drop 1.072 kPa
Molar Flow Feed Pressure
3.600e-012 kgmole/h 192.8 kPa
Letting the process run with the feed stream renewed, shows that 1900 kmol/hr of fluid leaves the process in stream
1, as previously observed in steady-state operation. The flow through the surge control valve returns to zero, while the
compressor’s speed, power, and capacity decrease to the steady-state values.
A view of the compressor’s efficiency curves throughout the dynamic disturbance modeling is shown in Figure 20.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
12
Jump Start: Compressor Modeling in Aspen HYSYS Dynamics
Conclusion
Controlling compressor surge is very significant for safe process operation and mitigating equipment malfunction and
subsequent replacement. Aspen HYSYS Dynamics helps engineers model the dynamic changes in performance expected
for a compressor experiencing a disturbance, as well as the response of a control loop connected to the compressor.
Using Aspen HYSYS Dynamics, many scenarios in which steady-state operation is interrupted can be considered and
designed for.
Both numerical and graphical dynamic models are generated in Aspen HYSYS Dynamics, which allows for in-depth
analysis to be performed on each completed simulation. In addition to stopping the feed to the compressor, as performed
in this guide, other compressor disturbances could be explored in Aspen HYSYS Dynamics. Control schemes and
parameters can also be modified, yielding more or less robust compressor control, depending on the user’s preference.
Aspen HYSYS Dynamics is a powerful tool that can be utilized to ensure safe and proper functioning of a process’s
compressors.
Additional Resources
Public Website:
http://www.aspentech.com/products/aspen-hysys.aspx
http://www.aspentech.com/products/aspen-hysys-dynamics.aspx
Online Training:
http://www.aspentech.com/products/aspen-online-training
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-7738-0715
13
About AspenTech
AspenTech is a leading supplier of software that optimizes process manufacturing—for energy,
chemicals, engineering and construction, and other industries that manufacture and produce products
from a chemical process. With integrated aspenONE® solutions, process manufacturers can implement
best practices for optimizing their engineering, manufacturing, and supply chain operations. As a result,
AspenTech customers are better able to increase capacity, improve margins, reduce costs, and become
more energy efficient. To see how the world’s leading process manufacturers rely on AspenTech to
achieve their operational excellence goals, visit www.aspentech.com.
Worldwide Headquarters
Aspen Technology, Inc.
20 Crosby Drive
Bedford, MA 01730
United States
phone: +1–781–221–6400
fax: +1–781–221–6410
info@aspentech.com
Regional Headquarters
Houston, TX | USA
phone: +1–281–584–1000
São Paulo | Brazil
phone: +55–11–3443–6261
Reading | United Kingdom
phone: +44–(0)–1189–226400
Singapore | Republic of Singapore
phone: +65–6395–3900
Manama | Bahrain
phone: +973–17–50–3000
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks For a complete list of offices, please visit
of Aspen Technology, Inc. All rights reserved. 11-7738-0715 www.aspentech.com/locations