Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

CHB V1.14 Operation Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ООО «СЕРВИСКИП» (3) Input Methods 1: thermocouple input 2: RTD input

607228 Нижегородская обл. г.Арзамас ул. Калинина (4) Output Methods 1: break output
д 50 Email: info@serviskip.ru Refrigeration
(5) 0: no refrigeration 1: stepping refrigeration 2:proportional refrigeration
Тел 89875552802 Web: serviskip.ru Methods
0:no alarm 1:upper limit alarm
(6) Alarm Methods
2:lower limit downward alarm 3:lower limit upward alarm
CHB Series Temperature Controller (7) Input Type 1: K 2: E 3: Pt100 4: Cu50 6: J
Operation Manual 1: relay contact switch output;
(8) Output Type 2: logic level output (used to control SSR);
Thank you for using Winpark products. Please read this manual carefully before operating the
3: single-phase SCR zero-crossing trigger output (used to control thyristor);
controller and always keep it around you to make it available easily anytime. 0: no refrigeration output; 1: relay contact switch output; 2: logic level
(9) Refrigeration Type output (used to control SSR); 3: single-phase SCR zero-crossing trigger output
CHB Serial PID Intelligent Temperature Controller adopts computer chip as the main (used to control thyristor)
control unit as well as many advanced techniques such as multiple digital filter circuit, PID auto- 0: no alarm output; 1: relay contact switch output;
tuning etc. It has advantages of high measurement accuracy, correct and stable temperature (10) Alarm Type 2: logic level output (used to control SSR);
3:single-phase SCR zero-crossing trigger output (used to control thyristor)
control, strong anti-interference and simple operation, and is widely used in chemical, ceramic, light,
Temperature 1: 0-100°C 2: 0-150°C 3: 0-400°C 4: 0-600°C
metallurgical, petrochemical and plastic industries. It is also an upgraded product of ordinary (11)
Range 5: 0-800°C 6: 0-999°C
analogue meters.
(12) Power supply Null: 180-240V -EP: 85 -260V
 General Electrical Data
180-240V AC 50/60HZ
Rated voltage Power Consumption ≤5W
85-265V AC 50/60HZ  External dimension and hole size
Temperature0 C
Accuracy class 1 class Working environment ~50 C,
RH: 35%~85%
Display
1 C Connection methods Terminal
accuracy

In accordance with standard of “Q/320401HBD001-2000XMT series PID intelligent temperature


controller”
 Panel explanation ①set key (SET)
②shift key (R/S)
③minus key(Ⅴ)
④plus key(Λ)
⑤measuring value(PV)  Wiring connection
⑥setting value(SV)
⑦output1 indicator (OUT1 green)
⑧output2 indicator (OUT2 green)
⑨alarm indicator (ALM ,red)
⑩auto-tuning indicator(AT,red)

 Product Model:
CHB □-□ □ □-□□□ □□ □ □ □
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12)
S/N Name Description
401: 48mm×48mm×85mm 402: 48mm×96mm×82mm Figure1 Figure2 Figure3 (CHB401 ONLY)
External
(1) 901: 96mm×48mm×82mm 702: 72mm×72mm×82mm
dimension
902: 96mm×96mm×82mm 168: 160mm×80mm×70mm
(2) Control Methods 0: PID control 1: stepping control
2

1
Notes: Block overshooting or undershooting caused by
Proportional proportional function. When SP=0, this function
1. The voltage range for switch power supply is 85 -260V 0-200°C 025
Band Separation is not available. And SP would be set to O
2. In figure 1 and 3, OUT1 is main output. If it is AC 30A/220V, there is only one pair of normally automatically after auto tuning.
open contacts; OUT2 is usually for alarm or refrigeration Set refrigeration proportion, PIV=0 means 000
3. Figure 2 is for phase-shift controller, OUT1 and OUT2 are both for output. Refrigerating
0-100 stepping refrigerating or alarm control. It is
4. Other special connection instructions please refer to the figures on the controllers. Proportion
ineffective for current or voltage output
5. Relay contacts output, AC 3A/220V (resistive load)
1. Set upper limit deviation alarm data.
6. Logic level output (to control SSR) DC0-12V, maximum output current 60mA
2.When PIv≠0, AHv means start value of
6. Two-way SCR zero-crossing trigger to control thyristor
Upper limit refrigerating
0-100°C 010
 Output connection Alarm Data 3. When the controller is in lower limit
downward alarm function, AHv value is lower
limit alarm value
Set circulation time of controller output (heating Relay:20
(Heating End) end). It is smoothing factor for current or Voltage:3
1-100
Output Cycle voltage output. The larger the factor, the SCR: 3
smoother the output
Temperature To modify temperature difference. The default
Modifying 0-200℃ value is 100(correspond to environment 100
parameter temperature). For 1 unit it is 1 degree.
Temperature (20-99)*1 temperature measuring range ( Special
Note: 1. Twisted-pair wire should be used to connect meter and SCR to reduce interference to SCR. instrument has no such function) 40
Range 0°C
2. In SCR output, the power supply of heater and meter should be the same. For example, when use 3
phase power supply, if the meter uses U Phase~zero line(AC220V), the heater should use the same To make PID data to suit customer’s system by
Auto-tuning 1, 2, 3 auto-calculation 000

When LKv= 000, all internal data are locked;


 Operation instruction Data Lock 0, 1 when LKv = 001, internal data can be modified. 000
Operation Procedures When Entering into Each State
1. In PID data setting mode, press SET key each time; data in following table shall be displayed in
Switch on power supply sequence. However, based on the ordered specifications, some data may not appear and the
initial value could be different.

Display code of sensor type, 2. if need stepping control, please set the following parameters: Pv=0 dv= down return
display code of temperature difference SPv=0(if don’t need return difference, set dv=0)

 Auto-tuning function
Press SET for 5 sec. and return, data is stored
PV/SV display mode  How to start and stop auto-tuning
Press SET and return, data is stored
1. When start auto-tuning, the heating system should be in working status and the measured
Press SE T
temperature should be lower than setting value.
Setting mode of data SV 2. Press SET key for 5 seconds to enter parameter setting mode. Click SET key until “LCK” appears,
Press SET for 5 sec, set LCK=1. Click SET key until “AT” appears and input auto-tuning type (1, 2, 3 optional,
usually choose 1). Press SET key for about 5 seconds, AT indicator light flashes. Auto-tuning is
Setting mode of data PID running.
3. press shift key“<” or minus key“Ⅴ”for 5 about seconds to enter auto-tuning status directly
 Parameter explanation When auto-tuning is accomplished, AT indicator light turns off. The controller has calculated out
a group of parameters fit to the system and would run
Initial under the new PID parameters.(New PID parameters
Sign Name Setting Description
Value could be found in the controller system.)
(Heating end)
1-100%* Set the heating proportional band, when Pv=0 Remark: auto-tuning functions (AT) are sorted into 1, 2,
Proportional 050
0.1% the controller is under stepping heating control 3 types
Band
1). AT=1 means No.1: general type, fast temperature
1-200*10 Remove static error, Iv=0 means PD heating
Integral Time 042 rise and excellent stability.
sec control
2). AT=2 means No.2: overshoot suppression type,
Block overshoot through output of forecast thus suitable for the quick system which can’t achieve short
0-200
Differential Time to rise up stability of controller. Dv=0 means PI 080 heating cycle.
sec.
heating control 3). AT=3 means No.3: lag/delay system type, especially
Block overshooting or undershooting caused by suitable for those systems which are hard to bring down the temperature after overshooting
Overshoot Block 0-200°C 010
integral function

4
3

You might also like