Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 130

-: Design Of Two Way Slab :-

Given Data

Data Symbol Value Units


Length ly 4.4 m

Breadth lx 4 m

Width Of Column/Wall bw 0.23 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 150 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.10

Check Two way slab

Depth of Slab :- dAssumed 126 mm


0.126 m
Dassuming 150 mm

Effective Span of Slab :-


(i) Leff1 4.23 m

(ii) Leff2 (lx) 4.126 m

(iii) Leff2 (ly) 4.526 m

Leff 4.126 m

* Hence The Slab is Supported Two Sides. So, It's Correspond


to Case 4 :-
Load Calculation :- Dead load 3.75 KN/m

Floor finish 3.49 KN/m


Live load 1.5 KN/m

Miscellaneous
Load KN/m

Total load 8.74 KN/m

Load Factor 1.5


Factored Load 13.11 KN/m

Moment :-
For ly/lx 1.10

αx 0.053
Support (-ve)
αy 0.047

αx 0.040
Mid Span (+ve)
αy 0.035
For αx = 0.053
Mux 11.82869976108 KNm
11828699.76108 Nmm
For αy = 0.047
Muy 10.48960167492 KNm

10489601.67492 Nmm
For αx = 0.040
Mux 8.9273205744 KNm

8927320.5744 Nmm
For αy = 0.035
Muy 7.8114055026 KNm
7811405.5026 Nmm

So, We take Maximum Moment at


8.9273205744 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.050793657537153 m


50.7936575371532 mm

OR
dreq. 0.05169844135183 m
dreq. = SQRT(Mumax./Ru * b)
51.6984413518296 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 167.407481075566 mm2

Spacing Of Bar :-
SpacingReq. 300.258280779861 mm
~ 200 mm

Area Of Steel Min. :-


AstMin. 180 mm2

Spacing Of Bar :-
SpacingMin. 279.252680319093 mm

Area Of Steel Prov. :-


AstProv. 251.327412287183 mm2

*Hence, AstProv. > AstMin. *Hence, Use Ast Provided.

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt 0.13 %

Check For Deflection :-


Pt(Req.) 0.13 %
Pt(Prov.) 0.20 %
AstProv. 251.327412287183 mm2
AstReq. 167.407481075566 mm2

Fs 193.16702889711
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F 2.00

D = (leff./23*M.F)+Clear D 111 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. 50

(l/d)Prov. = lx / deff. (l/d)Prov. 32

SLAB DESIGN IS SAFE

Number Of Bar :- NOS. 22


DIMENSIONS OF SLAB :- L= 4.4 B= 4

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load
From table 26 (IS 456:2000)
From IS 456:2000 (Cl. 38.1)

22
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.15 25 1 3.75

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

7.2 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5
-: Design Of Two Way Slab :-
Given Data

Data Symbol Value Units


Length ly 4 m

Breadth lx 3.6 m

Width Of Column/Wall bw 0.23 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 150 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.11

Check Two way slab

Depth of Slab :- dAssumed 126 mm


0.126 m
Dassuming 150 mm

Effective Span of Slab :-


(i) Leff1 3.83 m

(ii) Leff2 (lx) 3.726 m

(iii) Leff2 (ly) 4.126 m

Leff 3.726 m

* Hence The Slab is Supported Two Sides. So, It's Correspond


to Case 4 :-
Load Calculation :- Dead load 3.75 KN/m

Floor finish 3.49 KN/m


Live load 1.5 KN/m

Miscellaneous
Load KN/m

Total load 8.74 KN/m

Load Factor 1.5


Factored Load 13.11 KN/m

Moment :-
For ly/lx 1.11

αx 0.054
Support (-ve)
αy 0.047

αx 0.041
Mid Span (+ve)
αy 0.035
For αx = 0.054
Mux 9.78793879536 KNm
9787938.79536 Nmm
For αy = 0.047
Muy 8.55433493892 KNm

8554334.93892 Nmm
For αx = 0.041
Mux 7.3814001246 KNm

7381400.1246 Nmm
For αy = 0.035
Muy 6.3702494226 KNm
6370249.4226 Nmm

So, We take Maximum Moment at


7.3814001246 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.046186844837133 m


46.186844837133 mm

OR
dreq. 0.04700956782433 m
dreq. = SQRT(Mumax./Ru * b)
47.0095678243296 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 137.751838630987 mm2

Spacing Of Bar :-
SpacingReq. 364.898813380554 mm
~ 200 mm

Area Of Steel Min. :-


AstMin. 180 mm2

Spacing Of Bar :-
SpacingMin. 279.252680319093 mm

Area Of Steel Prov. :-


AstProv. 251.327412287183 mm2

*Hence, AstProv. > AstMin. *Hence, Use Ast Provided.

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt(Req.) 0.11 %

Check For Deflection :-


Pt(Req.) 0.11 %
Pt(Prov.) 0.20 %
AstProv. 251.327412287183 mm2
AstReq. 137.751838630987 mm2

Fs 158.94817377636
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F 2.00

D = (leff./23*M.F)+Clear D 102 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. 50

(l/d)Prov. = lx / deff. (l/d)Prov. 29

SLAB DESIGN IS SAFE


DIMENSIONS OF SLAB :- L= 4 B= 3.6

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load
From table 26 (IS 456:2000)
From IS 456:2000 (Cl. 38.1)
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.15 25 1 3.75

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

7.2 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5
-: Design Of Two Way Slab :-
Given Data

Data Symbol Value Units


Length ly 4.2 m

Breadth lx 3.69 m

Width Of Column/Wall bw 0.23 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 150 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.14

Check Two way slab

Depth of Slab :- dAssumed 126 mm


0.126 m
Dassuming 150 mm

Effective Span of Slab :-


(i) Leff1 3.92 m

(ii) Leff2 (lx) 3.816 m

(iii) Leff2 (ly) 4.326 m

Leff 3.816 m

* Hence The Slab is Supported Two Sides. So, It's Correspond


to Case 4 :-
Load Calculation :- Dead load 3.75 KN/m

Floor finish 3.49 KN/m


Live load 1.5 KN/m

Miscellaneous
Load KN/m

Total load 8.74 KN/m

Load Factor 1.5


Factored Load 13.11 KN/m

Moment :-
For ly/lx 1.14

αx 0.056
Support (-ve)
αy 0.047

αx 0.042
Mid Span (+ve)
αy 0.035
For αx = 0.056
Mux 10.6286489709893 KNm
10628648.9709893 Nmm
For αy = 0.047
Muy 8.97257881152 KNm

8972578.81152 Nmm
For αx = 0.042
Mux 8.00097626247805 KNm

8000976.26247805 Nmm
For αy = 0.035
Muy 6.6817076256 KNm
6681707.6256 Nmm

So, We take Maximum Moment at


8.00097626248 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.048086194898912 m


48.0861948989121 mm

OR
dreq. 0.04894275087388 m
dreq. = SQRT(Mumax./Ru * b)
48.9427508738797 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 149.602071422021 mm2

Spacing Of Bar :-
SpacingReq. 335.99456197127 mm
~ 200 mm

Area Of Steel Min. :-


AstMin. 180 mm2

Spacing Of Bar :-
SpacingMin. 279.252680319093 mm

Area Of Steel Prov. :-


AstProv. 251.327412287183 mm2

*Hence, AstProv. > AstMin. *Hence, Use Ast Provided.

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt(Req.) 0.12 %

Check For Deflection :-


Pt(Req.) 0.12 %
Pt(Prov.) 0.20 %
AstProv. 251.327412287183 mm2
AstReq. 149.602071422021 mm2

Fs 172.621841436111
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F 2.00

D = (leff./23*M.F)+Clear D 104 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. 50

(l/d)Prov. = lx / deff. (l/d)Prov. 29

SLAB DESIGN IS SAFE


DIMENSIONS OF SLAB :- L= 4.2 B= 3.69

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load
From table 26 (IS 456:2000)
From IS 456:2000 (Cl. 38.1)
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.15 25 1 3.75

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

7.2 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5
-: Design Of Two Way Slab :-
Given Data

Data Symbol Value Units


Length ly 3.69 m

Breadth lx 1.99 m

Width Of Column/Wall bw 0.23 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 100 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.85

Check Two way slab

Depth of Slab :- dAssumed 76 mm


0.076 m
Dassuming 100 mm

Effective Span of Slab :-


(i) Leff1 2.22 m

(ii) Leff2 (lx) 2.066 m

(iii) Leff2 (ly) 3.766 m

Leff 2.066 m

* Hence The Slab is Supported Two Sides. So, It's Correspond


to Case 4 :-
Load Calculation :- Dead load 2.5 KN/m

Floor finish 3.49 KN/m


Live load 1.5 KN/m

Miscellaneous
Load KN/m

Total load 7.49 KN/m

Load Factor 1.5


Factored Load 11.235 KN/m

Moment :-
For ly/lx 1.85

αx 0.087
Support (-ve)
αy 0.047

αx 0.066
Mid Span (+ve)
αy 0.035
For αx = 0.087
Mux 4.16822755366342 KNm
4168227.55366342 Nmm
For αy = 0.047
Muy 2.25388404402 KNm

2253884.04402 Nmm
For αx = 0.066
Mux 3.14117165762864 KNm

3141171.65762864 Nmm
For αy = 0.035
Muy 1.6784242881 KNm
1678424.2881 Nmm

So, We take Maximum Moment at


3.14117165763 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.030129696464695 m


30.1296964646954 mm

OR
dreq. 0.030666394608207 m
dreq. = SQRT(Mumax./Ru * b)
30.6663946082073 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 97.5668502347427 mm2

Spacing Of Bar :-
SpacingReq. 515.190173060825 mm
~ 200 mm

Area Of Steel Min. :-


AstMin. 120 mm2

Spacing Of Bar :-
SpacingMin. 418.879020478639 mm

Area Of Steel Prov. :-


AstProv. 251.327412287183 mm2

*Hence, AstProv. > AstMin. *Hence, Use Ast Provided.

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt(Req.) 0.13 %

Check For Deflection :-


Pt(Req.) 0.13 %
Pt(Prov.) 0.33 %
AstProv. 251.327412287183 mm2
AstReq. 97.5668502347427 mm2

Fs 112.579787101553
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F Or (Kt) 2.00

D = (leff./23*M.F)+Clear D 67 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. 50

(l/d)Prov. = lx / deff. (l/d)Prov. 26

SLAB DESIGN IS SAFE


DIMENSIONS OF SLAB :- L= 3.69 B= 1.99

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load
From table 26 (IS 456:2000)
From IS 456:2000 (Cl. 38.1)
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.1 25 1 2.5

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

6.0 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5
-: Design Of Two Way Slab :-
Given Data

Data Symbol Value Units


Length ly 3.1 m

Breadth lx 2.5 m

Width Of Column/Wall bw 0.23 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 150 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.24

Check Two way slab

Depth of Slab :- dAssumed 126 mm


0.126 m
Dassuming 150 mm

Effective Span of Slab :-


(i) Leff1 2.73 m

(ii) Leff2 (lx) 2.626 m

(iii) Leff2 (ly) 3.226 m

Leff 2.626 m

* Hence The Slab is Supported Two Sides. So, It's Correspond


to Case 8 :-
Load Calculation :- Dead load 3.75 KN/m

Floor finish 3.49 KN/m


Live load 1.5 KN/m

Miscellaneous
Load KN/m

Total load 8.74 KN/m

Load Factor 1.5


Factored Load 13.11 KN/m

Moment :-
For ly/lx 1.24

αx 0.061
Support (-ve)
αy 0.057

αx 0.061
Mid Span (+ve)
αy 0.043
For αx = 0.053
Mux 5.550862969704 KNm
5550862.969704 Nmm
For αy = 0.047
Muy 5.15308125852 KNm

5153081.25852 Nmm
For αx = 0.040
Mux 5.550862969704 KNm

5550862.969704 Nmm
For αy = 0.035
Muy 3.88741217748 KNm
3887412.17748 Nmm

So, We take Maximum Moment at


5.5508629697 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.040052458079929 m


40.0524580799288 mm

OR
dreq. 0.040765909671443 m
dreq. = SQRT(Mumax./Ru * b)
40.7659096714433 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 103.009557205005 mm2

Spacing Of Bar :-
SpacingReq. 487.969114918149 mm
~ 200 mm

Area Of Steel Min. :-


AstMin. 180 mm2

Spacing Of Bar :-
SpacingMin. 279.252680319093 mm

Area Of Steel Prov. :-


AstProv. 251.327412287183 mm2

*Hence, AstProv. > AstMin. *Hence, Use Ast Provided.

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt 0.08 %

Check For Deflection :-


Pt(Req.) 0.08 %
Pt(Prov.) 0.20 %
AstProv. 251.327412287183 mm2
AstReq. 103.009557205005 mm2

Fs 118.859981557908
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F 2.00

D = (leff./23*M.F)+Clear D 78 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. 50

(l/d)Prov. = lx / deff. (l/d)Prov. 20

SLAB DESIGN IS SAFE


DIMENSIONS OF SLAB :- L= 3.1 B= 2.5

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load
From table 26 (IS 456:2000)
From IS 456:2000 (Cl. 38.1)

15.5
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.15 25 1 3.75

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

7.2 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5
-: Design Of Two Way Slab :-
Given Data

Data Symbol Value Units


Length ly 3 m

Breadth lx 2.1 m

Width Of Column/Wall bw 0.3 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 100 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.43

Check Two way slab

Depth of Slab :- dAssumed 76 mm


0.076 m
Dassuming 100 mm

Effective Span of Slab :-


(i) Leff1 2.4 m

(ii) Leff2 (lx) 2.176 m

(iii) Leff2 (ly) 3.076 m

Leff 2.176 m

* Hence The Slab is Supported All Four Sides. So, It's


Correspond to Case 1 :-
Load Calculation :- Dead load 2.5 KN/m

Floor finish 3.49 KN/m


Live load 0.75 KN/m

Miscellaneous
Load KN/m

Total load 6.74 KN/m

Load Factor 1.5


Factored Load 10.11 KN/m

Moment :-
For ly/lx 1.43

αx 0.052
Support (-ve)
αy 0.032

αx 0.040
Mid Span (+ve)
αy 0.024
For αx = 0.052
Mux 2.46875560813714 KNm
2468755.60813714 Nmm
For αy = 0.032
Muy 1.53185943552 KNm

1531859.43552 Nmm
For αx = 0.040
Mux 1.89430831981714 KNm

1894308.31981714 Nmm
For αy = 0.024
Muy 1.14889457664 KNm
1148894.57664 Nmm

So, We take Maximum Moment at


1.89430831982 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.023397758534252 m


23.3977585342518 mm

OR
dreq. 0.023814541145467 m
dreq. = SQRT(Mumax./Ru * b)
23.8145411454669 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 58.2197353590118 mm2

Spacing Of Bar :-
SpacingReq. 863.375316762859 mm
~ 200 mm

Area Of Steel Min. :-


AstMin. 120 mm2

Spacing Of Bar :-
SpacingMin. 418.879020478639 mm

Area Of Steel Prov. :-


AstProv. 251.327412287183 mm2

*Hence, AstProv. > AstMin. *Hence, Use Ast Provided.

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt(Req.) 0.08 %

Check For Deflection :-


Pt(Req.) 0.08 %
Pt(Prov.) 0.33 %
AstProv. 251.327412287183 mm2
AstReq. 58.2197353590118 mm2

Fs 67.1782003421933
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F Or (Kt) 2.00

D = (leff./23*M.F)+Clear D 70 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. 50

(l/d)Prov. = lx / deff. (l/d)Prov. 28

SLAB DESIGN IS SAFE


DIMENSIONS OF SLAB :- L= 3 B= 2.1

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load

84
From table 26 (IS 456:2000)
From IS 456:2000 (Cl. 38.1)
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000

Mu/bd^2 0.189431
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.1 25 1 2.5

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

6.0 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5
-: Design Of Two Way Slab :-
Given Data

Data Symbol Value Units


Length ly 2.4 m

Breadth lx 2.06 m

Width Of Column/Wall bw 0.23 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 150 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.17

Check Two way slab

Depth of Slab :- dAssumed 126 mm


0.126 m
Dassuming 150 mm

Effective Span of Slab :-


(i) Leff1 2.29 m

(ii) Leff2 (lx) 2.186 m

(iii) Leff2 (ly) 2.526 m

Leff 2.186 m

* Hence The Slab is Supported All Four Sides. So, It's


Correspond to Case 7 :-
Load Calculation :- Dead load 3.75 KN/m

Floor finish 3.49 KN/m


Live load 0.75 KN/m

Miscellaneous
Load KN/m

Total load 7.99 KN/m

Load Factor 1.5


Factored Load 11.985 KN/m

Moment :-
For ly/lx 1.17

αx 0.069
Support (-ve)
αy 0.043

αx 0.051
Mid Span (+ve)
αy 0.043
For αx = 0.067
Mux 3.92615409006466 KNm
3926154.09006466 Nmm
For αy = 0.043
Muy 2.46267334158 KNm

2462673.34158 Nmm
For αx = 0.050
Mux 2.93530200275476 KNm

2935302.00275476 Nmm
For αy = 0.043
Muy 2.46267334158 KNm
2462673.34158 Nmm

So, We take Maximum Moment at


2.93530200275 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.029125629242922 m


29.1256292429215 mm

OR
dreq. 0.029644442008314 m
dreq. = SQRT(Mumax./Ru * b)
29.6444420083142 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 54.0445304101671 mm2

Spacing Of Bar :-
SpacingReq. 930.075293021336 mm
~ 200 mm

Area Of Steel Min. :-


AstMin. 180 mm2

Spacing Of Bar :-
SpacingMin. 279.252680319093 mm

Area Of Steel Prov. :-


AstProv. 251.327412287183 mm2

*Hence, AstProv. > AstMin. *Hence, Use Ast Provided.

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt(Req.) 0.04 %

Check For Deflection :-


Pt(Req.) 0.04 %
Pt(Prov.) 0.20 %
AstProv. 251.327412287183 mm2
AstReq. 54.0445304101671 mm2

Fs 62.3605426734731
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F Or (Kt) -84.88

D = (leff./23*M.F)+Clear D 23 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. -2122

(l/d)Prov. = lx / deff. (l/d)Prov. 16

REVISE
DIMENSIONS OF SLAB :- L= 2.4 B= 2.06

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load
From table 26 (IS 456:2000)
From IS 456:2000 (Cl. 38.1)
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.15 25 1 3.75

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

7.2 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5
-: Design Of Two Way Slab :-
Given Data

Data Symbol Value Units


Length ly 2.3 m

Breadth lx 1.95 m

Width Of Column/Wall bw 0.23 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 150 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.18

Check Two way slab

Depth of Slab :- dAssumed 126 mm


0.126 m
Dassuming 150 mm

Effective Span of Slab :-


(i) Leff1 2.18 m

(ii) Leff2 (lx) 2.076 m

(iii) Leff2 (ly) 2.426 m

Leff 2.076 m

* Hence The Slab is Supported All Four Sides. So, It's


Correspond to Case 5 :-
Load Calculation :- Dead load 3.75 KN/m

Floor finish 3.49 KN/m


Live load 0.75 KN/m

Miscellaneous
Load KN/m

Total load 7.99 KN/m

Load Factor 1.5


Factored Load 11.985 KN/m

Moment :-
For ly/lx 1.18

αx 0.051
Support (-ve)
αy 0.035

αx 0.039
Mid Span (+ve)
αy 0.035
For αx = 0.051
Mux 2.65415234311385 KNm
2654152.34311385 Nmm
For αy = 0.035
Muy 1.8078432876 KNm

1807843.2876 Nmm
For αx = 0.039
Mux 2.03432035879385 KNm

2034320.35879385 Nmm
For αy = 0.035
Muy 1.8078432876 KNm
1807843.2876 Nmm

So, We take Maximum Moment at


2.03432035879 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.02424703247186 m


24.2470324718598 mm

OR
dreq. 0.024678943139416 m
dreq. = SQRT(Mumax./Ru * b)
24.6789431394155 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 37.3559216096186 mm2

Spacing Of Bar :-
SpacingReq. 1345.5827159808 mm
~ 1300 mm

Area Of Steel Min. :-


AstMin. 180 mm2

Spacing Of Bar :-
SpacingMin. 279.252680319093 mm

Area Of Steel Prov. :-


AstProv. 38.6657557364898 mm2

*Hence, AstProv. > AstMin. Revise

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt(Req.) 0.03 %

Check For Deflection :-


Pt(Req.) 0.03 %
Pt(Prov.) 0.03 %
AstProv. 38.6657557364898 mm2
AstReq. 37.3559216096186 mm2

Fs 280.176012609676
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F Or (Kt) 2.00

D = (leff./23*M.F)+Clear D 66 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. 50

(l/d)Prov. = lx / deff. (l/d)Prov. 15

SLAB DESIGN IS SAFE


DIMENSIONS OF SLAB :- L= 2.3 B= 1.95

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load
From table 26 (IS 456:2000)
From IS 456:2000 (Cl. 38.1)
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.15 25 1 3.75

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

7.2 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5
-: Design Of Two Way Slab :-
Given Data

Data Symbol Value Units


Length ly 3 m

Breadth lx 2.05 m

Width Of Column/Wall bw 0.23 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 150 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.46

Check Two way slab

Depth of Slab :- dAssumed 126 mm


0.126 m
Dassuming 150 mm

Effective Span of Slab :-


(i) Leff1 2.28 m

(ii) Leff2 (lx) 2.176 m

(iii) Leff2 (ly) 3.126 m

Leff 2.176 m

* Hence The Slab is Supported All Four Sides. So, It's


Correspond to Case 9 :-
Load Calculation :- Dead load 3.75 KN/m

Floor finish 3.49 KN/m


Live load 0.75 KN/m

Miscellaneous
Load KN/m

Total load 7.99 KN/m

Load Factor 1.5


Factored Load 11.985 KN/m

Moment :-
For ly/lx 1.46

αx 0.089
Support (-ve)
αy 0.056

αx 0.089
Mid Span (+ve)
αy 0.056
For αx = 0.067
Mux 5.03956026043317 KNm
5039560.26043317 Nmm
For αy = 0.043
Muy 3.17792649216 KNm

3177926.49216 Nmm
For αx = 0.050
Mux 5.03956026043317 KNm

5039560.26043317 Nmm
For αy = 0.043
Muy 3.17792649216 KNm
3177926.49216 Nmm

So, We take Maximum Moment at


5.03956026043 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.038163240366421 m


38.1632403664205 mm

OR
dreq. 0.038843039456964 m
dreq. = SQRT(Mumax./Ru * b)
38.8430394569641 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 93.3759521246017 mm2

Spacing Of Bar :-
SpacingReq. 538.312930832148 mm
~ 200 mm

Area Of Steel Min. :-


AstMin. 180 mm2

Spacing Of Bar :-
SpacingMin. 279.252680319093 mm

Area Of Steel Prov. :-


AstProv. 251.327412287183 mm2

*Hence, AstProv. > AstMin. *Hence, Use Ast Provided.

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt(Req.) 0.07 %

Check For Deflection :-


Pt(Req.) 0.07 %
Pt(Prov.) 0.20 %
AstProv. 251.327412287183 mm2
AstReq. 93.3759521246017 mm2

Fs 107.744021512433
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F Or (Kt) 2.00

D = (leff./23*M.F)+Clear D 69 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. 50

(l/d)Prov. = lx / deff. (l/d)Prov. 16

SLAB DESIGN IS SAFE


DIMENSIONS OF SLAB :- L= 3 B= 2.05

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load
From table 26 (IS 456:2000)
From IS 456:2000 (Cl. 38.1)
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.15 25 1 3.75

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

7.2 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5
-: Design Of Two Way Slab :-
Given Data

Data Symbol Value Units


Length ly 3.35 m

Breadth lx 3.35 m

Width Of Column/Wall bw 0.23 m

Floor finish Fl 3.49 KN/m^2

Compressive Strength of Fck 25 N/mm^2


concrete
Yield Strength of steel Fy 500 N/mm^2

Assume Dia of Bars d1 8 mm

Slab thickness t 150 mm

b 1000 mm

Clear Cover CC 20 mm

Factor of saftey 1.5

Design

Aspect Ratio :- 1.00

Check Two way slab

Depth of Slab :- dAssumed 126 mm


0.126 m
Dassuming 150 mm

Effective Span of Slab :-


(i) Leff1 3.58 m

(ii) Leff2 (lx) 3.476 m

(iii) Leff2 (ly) 3.476 m

Leff 3.476 m

* Hence The Slab is Supported All Four Sides. So, It's


Correspond to Case 9 :-
Load Calculation :- Dead load 3.75 KN/m

Floor finish 3.49 KN/m


Live load 0.75 KN/m

Miscellaneous
Load KN/m

Total load 7.99 KN/m

Load Factor 1.5


Factored Load 11.985 KN/m

Moment :-
For ly/lx 1.00

αx 0.056
Support (-ve)
αy 0.056

αx 0.056
Mid Span (+ve)
αy 0.056
For αx = 0.067
Mux 8.10934170816 KNm
8109341.70816 Nmm
For αy = 0.043
Muy 8.10934170816 KNm

8109341.70816 Nmm
For αx = 0.050
Mux 8.10934170816 KNm

8109341.70816 Nmm
For αy = 0.043
Muy 8.10934170816 KNm
8109341.70816 Nmm

So, We take Maximum Moment at


8.10934170816 KNm
Mid-Span is
Neutral Axis Depth :- Xumax/d 0.46

Check For Depth :- dreq. 0.048410740065178 m


48.4107400651781 mm

OR
dreq. 0.049273077140145 m
dreq. = SQRT(Mumax./Ru * b)
49.2730771401454 mm

Ru 3.340152
Ru = 0.36*fck*Xumax/d*(1-
0.42*Xumax/d)

*Hence, dreq. < dAssumed OK SAFE

SECTION IS UNDER REINFORCEMENT

Calculation of Steel :- * Using 8 mm φ Bar :-


Dia. Of Bar 8 mm

Area Of Steel Req. :-


AstReq. 151.679519537379 mm2

Spacing Of Bar :-
SpacingReq. 331.392679847258 mm
~ 200 mm

Area Of Steel Min. :-


AstMin. 180 mm2

Spacing Of Bar :-
SpacingMin. 279.252680319093 mm

Area Of Steel Prov. :-


AstProv. 251.327412287183 mm2

*Hence, AstProv. > AstMin. *Hence, Use Ast Provided.

Percentage Of Steel :-
Pt = 100*AstProv./bd
Pt(Req.) 0.12 %

Check For Deflection :-


Pt(Req.) 0.12 %
Pt(Prov.) 0.20 %
AstProv. 251.327412287183 mm2
AstReq. 151.679519537379 mm2

Fs 175.018953426288
Fs =
0.58*Fy*(Astreq./AstProv.)

Modification Factor M.F Or (Kt) 2.00

D = (leff./23*M.F)+Clear D 97 mm
Cover + 1/2 Dia. Of Bar

(l/d)Max. = Fck x M.F (Kt) (l/d)Max. 50

(l/d)Prov. = lx / deff. (l/d)Prov. 27

SLAB DESIGN IS SAFE


DIMENSIONS OF SLAB :- L= 3.35 B= 3.35

LENGTH
TYPE SLABS
m

DEAD LOAD Roof slab 1

Plastering etc. 1
FLOOR
FINISHING Brick Coba Tiles 1
LOAD water proofing
Miscellaneous
Load
3.73

From table 26 (IS 456:2000)


From IS 456:2000 (Cl. 38.1)
From IS 456:2000 (Cl. 23.2.1) AT
Figure 4.

From IS 456:2000
WIDTH HEIGHT DENSITY Nos. Load Total Live Load (87
m m KN/m3 KN/m2 KN/m2
Type
1 0.15 25 1 3.75

1 0.01 24 1 0.24 Accessible Roof

1 0.15 20 1 3 Inaccessible Roof

0.25 Stairs

7.2 Cantilever slab


Live Load (875-part-2)
Floor Load
Remarks
KN/m2
1.5

0.75 (See "Inclined slab Load" for calculation)

1.5

You might also like