K Factor K Mu/bd PT RQD: Dia@ Dia@

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

BENDING REINF.

CALCULATION ROOF SLAB COUPLER

Mu = 4100.0 KNm
Clear Cover to reinf. nc = 100 mm
Dia of stirrups/link Lbar = 10 mm
Grade of Concrete fck = 35 N/mm2
Grade of Main Reinf. fy = 500 N/mm2
Grade of shear reinf fy = 415 N/mm2
Width of secion b = 1000 mm
Dia of spacer bar s = 32 mm
Depth of section D = 1400 mm

Effective Depth of section d = D-nc-Lbar-dia/2

dia = Long. Bar Diameter in mm

assuming dia = 25 mm

d= = 1277.5 mm

Limiting Moment Mu, lim = 0.36*xumax/d*(1 - 0.42*xumax/d)*fck*b*d2

Mu, lim /fckbd2 = 0.133 (Ref:SP-16 Table-C)

Hence Mu,lim = 8682.27 KNm

As Mu is less tha Mu,lim , section shall be designed as singly reinf. Section(ref Appendix G, IS 456-2000)

Mu = 0.87*fy*Ast*d*(1 - Ast*fy/b*d*fck)

K Factor K=Mu/bd2 = 2.512

%b of area of steel req pt rqd = 50*fck*(1-SQRT(1-4.6*K/fck))/fy


= 0.636 %

As rqd = pt rqd x bx d/100


= 8119 mm2

As,min = 0.12x bxD/100


1680 mm2

Hence req As As rqd = 8119 mm2

Provide 32 dia@ 135 mm C/C


32 dia@ 135 mm C/C
As Prov = 11915 mm2 OK

COUPLER-ROOF SLAB/Bending Moment Design