Toaz - Info Timber Design PR
Toaz - Info Timber Design PR
Toaz - Info Timber Design PR
Use Apitong
50% stress grade
E =4.57 GPa
Fb = 10.3 MPa
FV = 1.08 MPa
γ = 5.59 KN/ m3
Dead Loads
Wood shingles = 0.14 KPa
Wood furring = 0.12 KPa
Weight of roofing = (0.14+0.12)(0.58) = 0.1508 KN /m
Weight of purlins = 5.59(0.05)(0.1) = 0.03 KN /m
Weight of single-ply sheet = (0.03)(0.58) = 0.0174 KN /m
Live Loads slope ¿ 33 ° = 1.0 KPa
Roof live load (NSCP) = 0.58 KN / m
Wind Load
V = 200 (NSCP)
P = 0.0000473 V 2 = 1.892 KPa
2 (1.892 ) sin ( 14.93 )
P n= =0.914 KPa
1+ sin ( 14.93 )2
W n = 0.914(0.6) = 0.548 KN /m
5 w L4 5(1.3)(1000)4
∆= = =1.82 mm<4.16 mm
384 EI 3
∴ ok !
384 ( 4570 ) (
37 ( 87 )
12 )
Checking for bending
Fb = 10.3 MPa
2
w L2 1.3( 1000)
M n= = =162500
8 8
6 Mn 6(162500)
f bn= 2
= =3.48 MPa
bd 37( 87)2
2
w L2 0.20(1000)
M t= = =25000
8 8
6 Mt 6(25000)
f bt = 2
= =1.26 MPa
bd 87 (32)2
wL 1.3 (1000)
V n= = =650
2 2
3(650)
f vn= =0.30 MPa
2(37)(87)
wL 0.20(1000)
V t= = =100
2 2
3Vt 3(100)
f vt = = =0.05 MPa
2 bd 2 ( 37 ) (87)
V max = 5.866KN
M max = 4.916 KN m
∆ actual = 14. 102mm
f 6 M max 6(4.657)(1000)2
b= = =5.83 MPa <24.5 MPa ∴ok !
bd2 137(187)2
Loadings:
Total = 0.32 KN / m
Fn = 24.5 MPa W = 0.32 KN/m
0.32( 9)2
E = 9.78 GPa M max= =3.24 KN m
8
Fv = 2.49 MPa
γ = 7.46 KN/ m
3
4
5 (0.32)(9000)
¿ =28.96 mm<37.5 mm ∴ ok !
Actual Deflection 3
384 ( 9.78 x 103 ) (
87 ( 237 )
12 )
f 3V 3(1.44)
v actual= = =0.105 MPa<2.49 MPa∴ ok !
2 bd 2(0.1)(0.25)
f 6 (3.24)
b actual= 2
=3.978 MPa<24.5 MPa∴ ok !
(0.087)(0.237)
∴Use Yakal 80 stress grade 150 mm x 200 mm
DESIGN OF TRUSS
Yakal 80% stress grade
Fb ∧Ft =24.5 MPa
E = 9.78 GPa
F v =2.49 MPa
Dead Load
Weight of purlins = 0.028 KN/m
Weight of roofing = 0.1596 KN/m
Single-ply sheet = (0.03)(1.0) = 0.03 KN/m
Live Load
Roof live load = 1(1) = 1 KN/m
W T =W D +W L =0.2536+1=1.2356
Wind Load
V = 200 kph (NSCP, Zone 2)
P= 0.0000473 V 2 = 1.892
2 ( 1.892 ) sin (14.93 )
Pn = =0.77
1+ sin ( 14.93 )
W n = 0.77(1.0) = 0.77
TABULATION OF TRUSS STRESSES
TOP CHORD = 100mm x 200mm
BOTTOM CHORD = 100mm x 200mm
KING POST = 100mm x 200mm
WEB MEMBERS =100mm x 100mm
TRUSS FORCE DIRECTION F/AREA Fc all REMARKS
MEMBER (KN) (MPa) (Mpa)
AB 3.350 T 0.1675 24.5 OK!
AC 18.32 C 0.916 15.8 OK!
BC (web) 0.173 C 0.0173 15.8 OK!
BD 3.350 T 0.1675 24.5 OK!
CD (web) 3.922 C 0.3922 15.8 OK!
CE 6.599 C 0.32995 15.8 OK!
DE (web) 2.144 T 0.2144 24.5 OK!
DF 1.55 T 0.0775 24.5 OK!
EF (web) 5.044 C 0.5044 15.8 OK!
EG 14 542 C 0.7271 15.8 OK!
FG (web) 3.173 T 0.3173 24.5 OK!
FH 0.515 C 0.02575 15.8 OK!
GH (web) 6.186 C 0.6186 15.8 OK!
GI 12.342 C 0.6171 15.8 OK!
HI (web) 4.058 T 0.4058 24.5 OK!
HJ 2.739 C 0.13695 15.8 OK!
IJ (web) 5.643 C 0.5643 15.8 OK!
IK 10.512 C 0.5256 15.8 OK!
JK 8.288 T 0.414 24.5 OK!
KL 10.550 C 0.5275 15.8 OK!
JL (web) 3.397 C 0.3397 15.8 OK!
JM 3.443 C 0.17215 15.8 OK!
LM (web) 2.723 T 0.2723 24.5 OK!
LN 7.460 C 0.373 15.8 OK!
MN (web) 4.280 C 0.4280 15.8 OK!
MO 1.907 C 0.09535 15.8 OK!
NO (web) 2.010 T 0.2010 24.5 OK!
NP 13.313 C 0.66565 15.8 OK!
OP (web) 2.903 C 0.2903 15.8 OK!
OQ 0.718 C 0.0359 15.8 OK!
PQ (web) 0.585 T 0.0585 24.5 OK!
PR 14.478 C 0.7239 15.8 OK!
QR (web) 0.724 C 0.0724 15.8 OK!
QS 0.389 C 0.01945 15.8 OK!
RS (web) 0.129 T 0.0129 24.5 OK!
ST 0.389 C 0.01945 15.8 OK!
RT 14.969 C 0.74845 15.8 OK!
DESIGN OF BEAM
R1 =1.44KN
R= 9.372KN
T= 11.938
Trial Section 250x300mm
E= 9.78
γ = 7.4556
6 M max 6(34.021)
f b= 2
= 2
=10.46 MPa<24.5 MPa ∴ok !
bd (0.237)(0.287)
3V max 3 (22.892)
f b= = =0.51 MPa<2.49 MPa∴ ok !
2 bd 2(0.237)(0.287)
E= 7.70 MPa
Fb= 19.3MPa
Dead loads:
Hardwood= 0.19kPa
100mm x 50mm, 0.3 O. C = 0.3 KPa
Wood stud, 50mm x 100mm (unplastered) = 0.19 KPa
Plywood, 25mm = 0.24 KPa
Windows, glass = 0.38 KPa
Subflooring, 19mm = 0.14 KPa
Live Loads:
Residential = 1.9 KPa
Total Load = DL + LL = 1.44 + 1.9 = 3.34 KPa
3.34 KN
w total= ( 0.3 m) =1.002 kN
m2
M =1.127 kNm
V =1.503 kN
6 M 6( 1127000)
f b= = =4.14 MPa
b d2 87 (137)2
3V 3 (1503)
f v= = =0.189 MPa
2bd 2(87)(137)
0.189 MPa<1.96 MPa∴ safe
137
¿
¿
(87)(¿ 3¿¿ 12)=7.36 mm
384(7700)¿
4
5 w l 4 5(1.002)(3000)
∆= =
384 EI ¿
DESIGN OF COLUMNS
USE YAKAL 63% STRESS GRADE
E= 7.70 MPa
Fc = 12 MPa
ASSUME 100mm x 150mm
l e 3150
= =22.99
d 137
k =0.671
√ E
Fc
=0.671
√7700
12
=17
l
∴ e >k
d
0.30 E 0.30(7700)
F'c = = =4.37 MPa
le 2 (22.99)2
( )
d
L= 100mm
b= 4-16mm ∅
P= 14.2 KN
Q= 9.84 KN
For compression
Bolt all = 4(14.2)
= 56.8KN ¿ 18.32 KN
∴ Safe!
L= 100mm
b= 4-16mm ∅
P= 14.2 KN
Q= 9.84 KN
For Tension
Bolt all = 4(14.2)= 56.8KN ¿ 3.350KN
A
16
Wood all = (
200−4 16+
16)( 100 )=¿
323.4KN ¿ 3.350KN
(¿¿ net )=24.5 ¿
Ft ¿
∴ Safe!
Detail B
L = 100mm
b = 2 – 16mm dia.
P = 14.2 KN
Q = 9.84 KN
For Tension
Detail C
L = 100mm
b = 3 – 16mm dia.
P = 14.2 KN
Q = 9.84 KN
For Compression