rr310103 Structural Engineering Design and Drawing I (RCC)
rr310103 Structural Engineering Design and Drawing I (RCC)
rr310103 Structural Engineering Design and Drawing I (RCC)
1
III B.Tech I Semester Regular Examinations, November 2006
STRUCTURAL ENGINEERING DESIGN AND DRAWING-I(RCC)
(Civil Engineering)
Time: 3 hours Max Marks: 80
Answer any ONE Question from PART-A
and any THREE Questions from PART-B
Note:Assume suitable data whenever necessary
Use of IS codes & Structural Tables is permitted
⋆⋆⋆⋆⋆
PART-A(Marks:32)
1. Design the Flexural Reinforcement for the Rectangular concrete Beam of size 250
mm ×400mm simply supported an two marmarry walls 230mm thick and 6m apart.
The Beam has to carry in addition to its own weight, a distributed live load of
10kN/m, dead load of 5 kN/m and a concentrated dead load of 30kN placed at
the mid span point. Assume that the Beam in subjected to moderate exposure
conditions and grade of steel Fe 415 used.
Draw suitable scale longitudinal section and cross section of the Beam
2. Design an Isolated footing for a column 300mm x 500 mm reinforced with 6-25mm
dia bars with Fe 415 steel and M25 concrete subjected to a factored axial load of
1000 kN and a factored uniaxial moment of 120 kNM (with respect to the major
axis) at the column base. Assume that the moment is reversible. The safe bearing
capacity may be taken as 200kN/mm2 at a depth of 1.25m. Assume M20 concrete
and Fe 415 steel for the footing.
Draw to scale
PART-B (Marks:16x3=48)
4. (a) Define the term ‘partial safety factors’ as used in limit state design. Identify
the various factors and state the values recommended in IS 456.
(b) Compare ‘working stress method’ and ‘limit state’ design of R.C.C. structures.
Explain the answer with suitable examples.
1 of 2
Code No: RR310103 Set No. 1
6. (a) What is the minimum percentage of steel allowed in a R C column? Explain
why it is necessary to specify the minimum percentage
(b) A R.C. column rectangular in section 230mm wide and 300mm deep is re-
inforced with 4 bars of 20mm one at each corner with an effective cover of
50mm. It is subjected to an ultimate axial load of 340 KN, ultimate bending
Moment of M ux =30KN-M about X axis is bisecting the depth and ultimate
moment of M uy =18KN-M about Y axis bisecting the width. Use M20 grade
concrete and Fe 415 grade steel. Check the safety of the column.
7. Explain the I.S code provisions for limit state design for serviceability for deflection
of slabs. By assuming suitable data illustrate the same with a numerical example.
⋆⋆⋆⋆⋆
2 of 2
Code No: RR310103 Set No. 2
III B.Tech I Semester Regular Examinations, November 2006
STRUCTURAL ENGINEERING DESIGN AND DRAWING-I(RCC)
(Civil Engineering)
Time: 3 hours Max Marks: 80
Answer any ONE Question from PART-A
and any THREE Questions from PART-B
Note:Assume suitable data whenever necessary
Use of IS codes & Structural Tables is permitted
⋆⋆⋆⋆⋆
PART-A(Marks:32)
1. Design the Flexural Reinforcement for the Rectangular concrete Beam of size 250
mm ×400mm simply supported an two marmarry walls 230mm thick and 6m apart.
The Beam has to carry in addition to its own weight, a distributed live load of
10kN/m, dead load of 5 kN/m and a concentrated dead load of 30kN placed at
the mid span point. Assume that the Beam in subjected to moderate exposure
conditions and grade of steel Fe 415 used.
Draw suitable scale longitudinal section and cross section of the Beam
2. Design a plain concrete footing for a column 300mm × 30mm carrying an axial
load of 330 kN. Assume an allowable soil bearing pressure of 360 kN/m2 at a depth
of 1.0m below ground. AssumeM20 concrete and Fe 415 steel.
Draw to scale showing
PART-B (Marks:16x3=48)
3. Discuss the merits and demerits of the Traditional methods of design ( Working
stress method and ultimate load method).
5. When do steel reinforcements require splicing ? What is the length of bars that are
usually available in the market ? Enumerate the methods used for splicing.
6. Design an axially loaded tied column 400mm x 400mm pinned at both ends with
an unsupported length of 3m for carrying a factored load of 2300KN use M20 grade
concrete and Fe 415 steel.
1 of 2
Code No: RR310103 Set No. 2
7. Design a continuous floor slab for an office building 12m long and 4m wide supported
on floor beams spaced at 3m c/c. The live load on slab is 2.5kN/m2 . Concrete of
grade M 20 and are used.
⋆⋆⋆⋆⋆
2 of 2
Code No: RR310103 Set No. 3
III B.Tech I Semester Regular Examinations, November 2006
STRUCTURAL ENGINEERING DESIGN AND DRAWING-I(RCC)
(Civil Engineering)
Time: 3 hours Max Marks: 80
Answer any ONE Question from PART-A
and any THREE Questions from PART-B
Note:Assume suitable data whenever necessary
Use of IS codes & Structural Tables is permitted
⋆⋆⋆⋆⋆
PART-A(Marks:32)
2. Design a isolated footing for a rectangular column 300 x 450mm carrying an axial
load of 1000 kN. The net bearing capacity of the soil is 120kN/m2 . Use M20 grade
concrete and Fe 415 grade steel.
Draw to scale the reinforcement details.
PART-B (Marks:16x3=48)
3. (a) Is the limit state method in any way a better method of design of concrete
structures than the working stress design? Give reasons for your answer.
(b) Enumerate the five limit states commonly used in limit state design and state
briefly how they are provided for in design.
4. What is meant by limit state? Discuss the different limit states to be considered
in reinforced concrete design.
5. Determine the shear stress in a 250 X 500 mm rectangular section if the shear force
is 20 kN and torsional moment is 10 kN.m at service loads. Asume M 20 mix and
0.75% tension reinforcement at an effective coverof 50 mm.
6. (a) How does bracing effect the behavior of slender columns? Explain how bracing
can be provided for columns in Multistoried buildings.
1 of 2
Code No: RR310103 Set No. 3
(b) A column 350 x 350mm has an unsupported length of 8m and equivalent
length of 5m both the axes. It is loaded with characteristic loads P=500KN,
Mxx (top)=40KN-m Mxx (bottom)=-25KN-M. Assuming the column is bent
in double curvature design the longitudinal steel. Use M30 & Fe415.
7. Design a one way simply supported slab of span 4.5m to cary a live load of 4kN/m2
floor finish of 1kN/m2 and partitions 1kN/m2 . Use M 20 grade concrete and Fe
415 grade TOR steel.
⋆⋆⋆⋆⋆
2 of 2
Code No: RR310103 Set No. 4
III B.Tech I Semester Regular Examinations, November 2006
STRUCTURAL ENGINEERING DESIGN AND DRAWING-I(RCC)
(Civil Engineering)
Time: 3 hours Max Marks: 80
Answer any ONE Question from PART-A
and any THREE Questions from PART-B
Note:Assume suitable data whenever necessary
Use of IS codes & Structural Tables is permitted
⋆⋆⋆⋆⋆
PART-A(Marks:32)
2. Design an isolated circular footing for a square column of 500mm diameter is trans-
mitting a load of 900 kN to a soil having an allowable bearing capacity of 90kN/m2 .
Use M20 concrete and Fe 415 grade steel. Draw to scale showing reinforcement de-
tails
PART-B (Marks:16x3=48)
4. (a) Why does the code impose minimum and maximum limits with regard to
i. spacing
ii. Percentage area of flexural reinforcement.
(b) What the advantages and disadvantages of providing large clear cover to re-
inforcement in flexural members.
5. (a) Calculate the stresses produced in a rectangular beam 350 X 800mm due to
torsion of 30KNm. What is the nature of these stresses and what type of
reinforcements should be provided to resist these stresses?
(b) Sketch the pattern of cracking in a beam under torsional moment.
1 of 2
Code No: RR310103 Set No. 4
6. Design an axially loaded tied column 400mm x 400mm pinned at both ends with
an unsupported length of 3m for carrying a factored load of 2300KN use M20 grade
concrete and Fe 415 steel.
7. Design the end span of a one way continuous slab for the following data: span =5m,
live load = 3kN/m2 partitions = 1kN/m2 floor finish 0.75kN/m2 . Concrete; M 20
grade and steel: Fe - 415 grade.
⋆⋆⋆⋆⋆
2 of 2