Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Kitchen

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 39

CENTRAL KITCHEN AT HARINGATTA, WEST BENGAL

BILL OF QUANTITIES FOR EXTERNAL AND INTERNAL PHE SYSTEM

COST SUMMARY
Sl Nr DESCRIPTION Total
EXTERNAL PHE SYSTEM
A EXTERNAL SEWAGE SYSTEM -
B EXTERNAL WATER SUPPLY SYSTEM -
C PUMP ROOM -

ADITHI CONSULTANTS 1
INSTAKART SERVICES PVT. LTD
CENTRAL KITCHEN AT HARINGATTA, WEST BENGAL
BILL OF QUANTITIES FOR EXTERNAL PHE WORKS

General Notes:
1)The scope Includes:
a) Rates shall be on FOR Site basis, including packing & forwarding, loading, frieght, transit insurance (covering unloadin
b) Scope of Installation, Testing and Commissioning shall also include Unloading, Storage & Handling, Watch and Ward a
along with necessary documentations

2)In case of any conflict between Technical Specifications and BOQ, the later shall prevail over the other.
3)As far as possible vendor should plan for bulk procurement of the materials so as to place order directly to primary ma
4)BOQ shall be followed for method of measurement. In case BOQ is silent, technical specification will be referred.
5)Unless otherwise specified, measurement shall be only for actual laid/installed quantity as per the approved drawing.
Wastages/breakages
6)Performance curve (if any)
of all shall
the not be
pumps considered
shall be sharedfor measurement
alongwith and consequent payment.
the bid.

SL. NO. DESCRIPTION UOM Quantity


A. EXTERNAL SEWAGE SYSTEM

Excavation in all types of soil for laying pipes up to 300


mm dia. including forming bottom surface to required
level, filling available earth around the pipe in layers
150mm thick and back filling, watering and making
compaction and disposing off the surplus soil away from
the site as directed by the site engineer complete. Rate
to also include cost of dewatering, if required.
1 Mode of Measurement- Measurement and payment
shall be done considering width of pipe/pipes, depth as
per drawing/authorized and acutal laid quantity. No
allowance shall be made for working space and side
slope stabilization.

a) Soft soil & ordinary soil- Upto 1.5 mtr Depth Cum 450
b) Soft soil & ordinary soil- from1.5 mtr to 3 mtr Depth Cum 100
Supplying, fixing and testing unplasticized PVC SWR
pipes confirming to IS 13592 and fittings shall be as per
IS 14735, type B with rubber ring / Solvent (confirming
to IS 5382) joint inclusive of all necessary specials like
bends, tees, offsets, door bends, junctions, cowls, etc.,
laid below ground / fixed on walls, and in pipe shafts
etc., complete. The rate shall include necessary GI
supports, GI grip bolts, angle brackets, hangers,
supports as with suitable GI U-clamps, bolts, nuts and
washers etc., The clamps shall be painted with two
coats of enamel (approved) paint over a coat of primer
2 etc., complete. with testing of joints complete. As per
direction of Engineer in Charge.
Mode of measurement-Pipe length shall be measured
along the centre line of the pipe including all fittings
(Tees, bends etc).. Payment shall be made only for
actual laid / installed quantities.

Shaft Piping
a) 75 mm dia RM 10
b) 110 mm dia RM 30
c) 160 mm dia RM 20

Underground Piping
a) 160mm dia RM 10
b) 200mm dia RM 15
c) 250mm dia RM 20
d) 300mm dia RM 20

Supplying and laying of follwoing Dia HDPE Pipes for


depth upto 1.2 mtr. Rate to include excavation,
backfilling, labour, material, tools & tackles, P&M,
consumables, including making brick chambers/pull pits
of required size at every 30 mtrs etc a to complete the
work. Mode of Measurement- Only actual Installed
2.0 quantity shall be measured and paid for. Wastage, etc
shall not be measured and paid.(Confirming to IS 4984
1995)

250 mm dia( PE 80, PN 10)- Base Rate for Supply & Mtrs
a Installation work shall be Rs 2,500 per RM. 45
200 mm dia( PE 80, PN 10)-Base Rate for Supply & Mtrs
b Installation work shall be Rs 2,200 per RM 235
150 mm dia( PE 80, PN 10)-Base Rate for Supply & Mtrs
c Installation work shall be Rs 1,800 per RM 985
Supplying, installing, fixing, jointing, testing and
commissioning of approved make Unplastized Polyvinyl
Chloride pipes (uPVC) schedule 40 conforming to ASTM
D 1785. Fittings in schedule 40 up to 50 dia, fitting in
schedule 80 more the 65dia confirming to ASTM D 1785.
The fittings and specials such as tees, elbows, couplers,
reducers etc. with uPVC brass threaded combination /
transition specials such as male adapters brass threaded
(MABT), female adapters brass threaded (FABT), Brass
Tee, Brass elbow etc., where connection with metal is to
be made including necessary drilling holes, chasing walls
and making the same good in cement mortar 1:1 and
restore the same in original condition neatly as directed
by the Engineer in-charge. Joints to be made with UPVC
solvent adhesive up to 2" dia as per ASTM D-2564 and
for system above 2" dia primer as per ASTM F 656, and
3 solvent adhesive conforming to ASTM D 2564. The
solvent used shall be of approved make, preferably from
the pipe manufacturer. Rate shall include necessary MS
supports, clamps, hanging rods, Grip bolts t etc.,
complete in all respect. The rate shall include the cost of
galvanized U clamps, bolts & nuts,etc,complete Note:
For Sewage water Pumping.
Mode of measurement-Pipe length shall be measured
along the centre line of the pipe including all fittings
(Tees, bends etc).. Payment shall be made only for
actual laid / installed quantities.

a) 100mm dia RM
b) 65mm dia RM

Supply of materials and construction of inspection


chamber as per IS 1742 with 230 mm best quality
approved Fly-ash cement brick in CM 1:2 over a bed of
150mm thick PCC 1:4:8, The internal & External walls to
be plastered with min 15mm thick within CM 1:3 with
water proofing compound and finished with a coat of
neat cement. The benching and channeling in PCC 1:2:4
and plastered with cement mortar of 1:2, supplying and
fixing PVC rungs as per drawing for 'maintenance and
4 Supplying and fixing of heavy duty DI frame and cover of
weight not less than 110 Kgs of required size 600 x 600.
The quoted rate shall also include necessary excavation
and back filling, 100 mm thick RCC M25 grade pre cast
cover slab with Reinforcement as per drawing etc.,
complete.

a) 300mm x 300mm  up to 600mm deep Nos. 16


b) 600mm x 600mm  up to 1000mm deep Nos. 69
c) 900mm x 600mm x 1500mm deep Nos. 10

Supply of materials and construction of Circular


manhole as per IS 1742 with best quality, approved Fly-
ash cement brick in CM 1:2, over a bed of 300mm thick
PCC 1:4:8, both internal and external walls to be
plastered with min 15mm thick within CM 1:4 with
water proofing compound and finished with a coat of
neat cement. The benching and channeling in PCC 1:2:4
and plastered with a coat of neat cement, supplying and
fixing PVC rungs as per drawing for 'maintenance. The
5 manhole shall be provided with heavy duty DI frame and
cover of weight not less than 110 Kgs. circular 600mm
dia. clear opening etc., complete. The quoted rate shall
also include necessary excavation and back filling etc.,
complete.

a) 1200mm dia upto 1.5m Depth Nos. -


b) 1200mm dia upto 3.0m Depth Nos. 2

Constructing 2400mm x 1000mm x 1200mm Grease Nos.


chamber in brick masonary in cement mortar 1:4
including internal and external plastering in cement
6.0 mortar 1:2 along with M.S. Basket, covered with 3 nos. 3
FRP grating of 20 Tone Load Bearing Capacity, etc. all
complete as per detailed drawing.

Constructing 2400mm x 1000mm x 1200mm filtration Nos.


chamber in brick masonary in cement mortar 1:4
including internal and external plastering in cement
7.0 mortar 1:2 filled with filter media aggregates covered 2
with FRP grating of 20 Tone Load Bearing Capacity, etc.
all complete.
Laying, jointing and testing socketed and spigotted RCC
pipes (NP3 class) conforming to IS : 458 collars jointed
with stiff mixture of cement mortar in the proportion of
1:1 (1 cement : 1 fine sand) laid to correct levels below
ground in trenches up to average 2.50m depth including
excavation in all kinds of soil, dewatering, refilling,
watering, ramming and removing the surplus excavated
material and making good the same complete as
required. Cost shall be inclusive of providing protection
8 to pipe all round / haunches as per specification.
Mode of measurement- Only actual laid quantity as per
approved drawing shall be considered for measurement
and payment purpose

a) 300mm dia RM 75

Providing and laying RCC hume pipe (NP-2) with collars


,jointing in CM 1:2 with spun yarn etc. complete.Rate
inclusive of necessary excavation aligning, curing,
9.0 refilling, consolidating etc.complete as directed.

a 150mm Dia RM 50
b 200mm Dia RM 45
c 250mm Dia RM 40
d 300mm Dia RM 35
e 450mm Dia RM 35

Cum
Drainage pipe encasement Application: Drainage pipes,
Types of Encasement : PCC, Ratio of Encasement :
10 1:2:4 ,Thickness of the Encasement : 100mm around the 120
pipe, Installation: As per the specification. 50 to160mm
dia

Providing and fixing online filtration PVC filter -


11
Rainyflow
110mm dia. Nos. 1

Providing and fixing RWH pipe (110 dia.) to existing Nos.


12 Bore-well for recharge purpose, including NRV, Ball 1
Valve & bypass line connecting to SWD. All complete.

Providing and fixing THERMODRAIN FRP gratings in


13 short lengths of 600mm. (For Ground Level)
395mm wide x 990 mm long (20 Tone load bearing Nos.
capacity) 16
RM
Providing and fixing angle nozing for storm water
channels fabricated out of M.S. Angle 32 x 32 x 5mm
14 30
grouted in P.C.C. 1:2:4, including all complete.
(Basement Level)

A - Total Carried Over to Summary

B EXTERNAL WATER SUPPLY SYSTEM

Supplying, installing, fixing, jointing, testing and


commissioning of approved make Chlorinated Polyvinyl
Chloride pipes (CPVC) of Schedule 80 with schedule 80
fittings as per ASTM F 439. The fittings and specials such
as tees, elbows, couplers, reducers etc. with CPVC brass
threaded combination / transition specials such as male
adapters brass threaded (MABT), female adapter brass
threaded (FABT), Brass Tee, Brass elbow etc., where
connection with metal is to be made, including
necessary drilling holes, chasing walls and making the
same good in cement mortar 1:1 and restore the same
in original condition neatly as directed by the Engineer
in-charge. Joints to be made with two-step solvent
adhesive to be used. Primer conforming to ASTM F 656,
and solvent adhesive conforming to ASTM F 493. The
solvent used shall be of approved make as
1 recommended by the pipe manufacturer. Rate shall
include necessary MS supports, clamps, hanging rods,
Grip bolts etc., complete in all respect. The rate shall
include the cost of galvanized U clamps, bolts &
nuts,supports etc., (For domestic water supply).
Mode of measurement-Pipe length shall be measured
along the centre line of the pipe including all fittings
(Tees, bends etc).. Payment shall be made only for
actual laid / installed quantities.

Internal
a) 20mm dia - SDR 11 RM 10
b) 25 mm dia - SDR 11 RM 10
c) 40 mm dia - SDR 11 RM 10
d) 50mm dia - SDR 11 RM 10

External
a) 25 mm dia - SDR 11 RM 40
b) 40 mm dia - SDR 11 RM 40
c) 50mm dia - SDR 11 RM 30
d) 65mm dia - SCH 80 RM 20
e) 80 mm dia - SCH 80 RM 10
f) 100 mm dia - SCH 80 RM 10
g) 150mm dia -- SCH 80 RM 10

Providing and fixing cast iron lever operated slim seal


type PN 16 butterfly valves of CI body conforming to IS
2 778 with nitrile rubber seal, including bolt nuts, and
Neoprene rubber gaskets etc., Complete

Internal
a) 50mm dia Nos. 5
b) 40mm dia Nos. 4

External
a) 150mm dia Nos. 10
b) 80mm dia Nos. 10
c) 65mm dia Nos. 8
d) 50mm dia Nos. 4
e) 40mm dia Nos. 3

Supplying, installing, testing and commissioning


3 approved make GM ball valves PN 25 conforming to IS
778 : 1984 with unions etc., complete.
Internal
a) 20mm dia Nos. 5
b) 25mm dia Nos. 5
c) 32mm dia Nos. 5

External
a) 25mm dia Nos. 4

Providing and fixing brass screwed/flanged type


4.0 mosquito proof grating for under ground suction tank,
over flow and vent of the following diameters.
50mm dia. Nos. 20

Providing and fixing G.M. heavy non-return valve screwed


5.0 type.(16 Kgs/cm2)
a 50mm dia.. Nos. 2
b 40mm dia.. Nos. 4

Providing and fixing FRP water tank covers with lock


6.0 and patti arrangement frame including fixing the same
complete as per detailed drawings
600mm dia. (5 Tone load bearing cap. For Over Head Nos.
Tank) 8
Providing and fixing heavy duty Bib tap for landscaping.
7.0
15mm dia. Nos. 20

Providing and fixing automatic flow control system for


8.0 U.G.Tank, all complete
50 dia Nos. 4
40 dia Nos. 4

Supplying & fixing brass auto air vent for water supply
9 risers, suitable for pressure not less than 15 Kg/Sq.cm.

25 mm dia Nos. 16

Supplying, installing, testing and commissioning


approved make conventional Water Meter (Bulk Type)
conforming to IS 2373 and with necessary unions for
fixing on the inlet main as shown on the drawing, etc.,
'complete with necessary gate valve,NRV, strainers, by-
10 pass line with gate valves union etc., complete. (3 gate
valves, 1 strainer & 1 check valve)

a) 100 mm dia No. 1


b) 80mm dia No. 1
c) 65mm dia No. 1
d) 50mm dia No. 1

Supplying, installing and commissioning approved make


CI 'Y' type strainer with flanged end with necessary nuts
11 and bolts, neoprene rubber gaskets, flanges, etc..,
complete.

a) 150 mm dia No. 3


b) 80mm dia. Nos. 4
c) 65mm dia. Nos. 4
d) 50mm dia.. Nos. 4
e) 40mm dia.. Nos. 4
Supplying, installing, fixing, jointing, testing and
commissioning of approved make Unplastized Polyvinyl
Chloride pipes (uPVC) schedule 80 conforming to ASTM
D 2467. Fittings in schedule 80 confirming to ASTM D
2467. The fittings and specials such as tees, elbows,
couplers, reducers etc. with uPVC brass threaded
combination / transition specials such as male adapters
brass threaded (MABT), female adapters brass threaded
(FABT), Brass Tee, Brass elbow etc., where connection
with metal is to be made including necessary drilling
holes, chasing walls and making the same good in
cement mortar 1:1 and restore the same in original
condition neatly as directed by the Engineer in-charge.
Joints to be made with UPVC solvent adhesive up to 2"
dia as per ASTM D-2564 and for system above 2" dia
primer as per ASTM F 656, and solvent adhesive
12 conforming to ASTM D 2564. The solvent used shall be
of approved make, preferably from the pipe
manufacturer. Rate shall include necessary MS supports,
clamps, hanging rods, Grip bolts t etc., complete in all
respect. The rate shall include the cost of galvanized U
clamps, bolts & nuts,supports etc.,.
Mode of measurement-Pipe length shall be measured
along the centre line of the pipe including all fittings
(Tees, bends etc).. Payment shall be made only for
actual laid / installed quantities.

a) 25 mm dia RM
b) 40 mm dia RM 250
c) 50 mm dia RM 200
d) 65 mm dia RM
e) 80 mm dia RM 490
f) 100 mm dia RM 15

Providing and fixing heavy class ('C' class) G.I. pipes


with threaded joints including cutting the pipes to
correct length, fixing with clamps to G.I. brackets/
hangers with anchor fasteners. testing, painting the
exposed pipes with 2 coats of enamel paint over a coat
of primer, chasing in walls/floors making good the
13.0 same all complete as per specifications and directions
of the Engineer-in-charge (Including fittings &
Excavation) for the following diameters.

a 50mm dia. (for Municipal Inlet) RM 30


b 100mm dia. (for Municipal Inlet) RM 1,724
Laying, jointing and testing socketed and spigotted RCC
pipes (NP3 class) conforming to IS : 458 collars jointed
with stiff mixture of cement mortar in the proportion of
1:1 (1 cement : 1 fine sand) laid to correct levels below
ground in trenches up to 2.50m depth including
excavation in all kinds of soil, dewatering, refilling,
watering, ramming and removing the surplus excavated
material and making good the same complete as
required. Cost shall be inclusive of providing protection
14 to pipe all round / haunches as per specification.
Mode of measurement- Only actual laid quantity as per
approved drawings shall be considered for
measurement and payment purpose.

a) 300mm dia RM 948

Supply of materials & constructing 230mm thick Fly-ash


brick masonry chamber (for valves, Meters etc.) in CM
1:4 over a bed of 150mm thick PCC 1:4:8, The internal &
External walls to be plastered with min 15mm thick
within CM 1:3 and finished with a coat of neat cement.
The benching and channeling in PCC 1:2:4 and plastered
with cement mortar of 1:2, supplying and fixing PVC
rungs as per drawing for 'maintenance with heavy duty
DI manhole cover and frame. Including excavation,
15 dewatering, 100 mm htick RCC M25 grade cover slab
with Reinforcement as per drawing, refilling, watering,
ramming and removing the surplus excavated material
complete as required. (All sizes are clear internal sizes).

450mm X 450mm up to 600mm depth (450 x 450mm Nos.


a) Cover with Frame) 2
600mm X 600mm up to 1000mm depth (600 x 600mm Nos.
b) cover with frame) 1
1200mm X 450mm up to 600mm depth (2 Nos of 600 x Nos.
c) 450mm cover with frame) 1

Supplying, installing and testing of 150 mm dia (GI B


Class) tanker browser connection system near tank
location. This includes 150 dia standpost, non return
valve, Strainer, Butterfly Valve & instantaneous brass
coupler, etc., complete, the cost should include the
16 online booster pump of capacity 3LPS @ 20m 1
head(1Working + 1Standby), cabling, stater Panel
(indoor type) with push buttons, Complete

LOT
Supplying, installing, testing and commissioning LS
approved make water level controllers for the RAW and
treated water tanks. Cost is including 1.5 sqmm X 3
17 core unarmoured Copper PVC FRLS cable in 20mm dia 1
PVC conduits (1 set =1 no. high level, 1 No middle level
& 1 no. of low level cable )

B - Total Carried Over to Summary

C PUMP ROOM

Supply, installation, testing & commissioning of the


following

Type: Non-clog, semi open type Submersible storm


water pump to handle muddy water with cutter
arrangement to handle particle size of 40 mm

No. Outlets: Single Outlet

Casing: Epoxy coated Cast Iron casing


Impellers:

Material of construction: stainless steel Impellers.

Shaft: High tensile 410 AISI Stainless Steel shaft

Type Bearing: Deep groove ball bearings. Bearing to


be enclosed with high temp. grease containing special
anti-corrosive addivite.

Pump RPM : 2900 RPM

Motor RPM : 2900 RPM

Type of Motor :3 Phase Induction Motor.

Motor Insulation: Class "B" (to suit


ambient Temp. (0 to 35 Deg.C)

No. of Poles: 2 Nos

Supply Voltage : 415 + 10%


Cycles/Sec. : 50 Hz + 5%

Accessories :

Foundation bolts, vibration isolators, base plate,


stuffing Box.

Cabling & inter connecting piping of 75mm dia.,


isolation valve, NRV and cabling upto control panel
located with 10 M Radius.

Mounting frame
Pump Duty Condition

250 LPM at 15 Mt head. (for Plant Room) Approximate Set


H.P. = 2 (1 Working +1 Standby) 2

CONTROL PANEL
Note:

Tenderer shall provide any all suitable cables as


required for respective Panels to Pump for complete
working of the System at no additional cost.

Fabricating, Supplying and installing in position sheet


steel wall/clad floor mountingcubical pattern front
opening type control panel.

Control panel shall be fabricated from 14 gauge


M.S. sheet. After fabrication all M.S. parts shall be
thoroughly degreased and cleaned for rust and scales,
shall then be passed through seven tank process pre-
treatment. A coat of Zinc Chromate primer & two
coats of synthetic enamel paint of light grey shade
shall be applied over the treated surface. BMS
connectivity provision should be provided in the panel 5
nos I/O points

All the pumps can be selected for Auto/manual position


through its individual selector switches. In manual
position the pump shall run continuously till switched
off & stop. In automatic position the pump
shall Start/Stop on level controller. Water level
controller should be included in the above rate.
Pump rm Sump Pump (2 Nos.) 2 H.P. No 2

OHT FEED PUMPS

Type: Vertical Inline type direct coupled diffuser type


centrifugal pump.
No. Outlets: Single Outlet
Casing: Material of Construction, CI
Impellers: Material of construction: SS
Shaft: High tensile 410 AISI Stainless Steel shaft

Type of Bearing: Tungsten carbide bearing on shaft &


ceramic bearing in diffuser
Pump RPM : 2900 RPM
Motor RPM : 2900 RPM
Type of Motor : 3 Phase Squirrel cage Induction
TEFC Motor .
Motor Insulation: High grade PVC suit ambient
Temperature.(0 to 35 Deg.C)
No. of Poles: 2 Nos.
Supply Voltage : 415 + 10%
Cycles/Sec. : 50 Hz + 5%
Accessories: Foundation bolts, vibration isolators,
base plate, 65mm dia. piping with 65mm dia. non
return valve, 65mm dia.butterfly valve up to tank top
slab with a common header of 65mm dia. with flanged
outlet for connection by client

Pressure gauges, switches


Mounting Frame

Flushing Pumps

Pumps 85 LPM @ 30 Mt. head, 2.0 H.P. x 1 + 1 Nos. 2

Raw Water Feed Pumps

Pumps 750 500 LPM @ 10 Mt. head, 5.0 H.P. x 1 + 1 Nos. 2

RO Water Transfer Feed Pumps

Pumps 500 LPM @ 30 Mt. head, 6.0 H.P. x 1 + 1 Nos. 2

CONTROL PANEL
MCC Motor control centres shall be of tailor-made
design, wall/ floor-mounted type manufactured in
factory/shop. Enclosure shall be fixed type (modular
draw-out design), dust-tight and vermin-proof
having IP54 degree of protection. Main bus for
phase and neutral shall be of uniform size
insulated electrolytic copper. Separate insulated
copper earth bus within the board shall be
provided with a link between neutral and earth bus.

Board shall be provided with tow distinct and


separate earth terminals on opposite side to connect
external earth conductor. All accessible live
terminals/ portion of components shall be provided
with shrouds.

Board shall be of sheet steel enclosed free-standing


self-supporting indoor type having front and rear
doors. Minimum 2.5mm thick cold rolled (CR) sheet
steel shall be used for load bearing members and
1.6mm thick CR sheet shall be used for doors and
covers.

Board shall be provided with 75mm high base


channel, with holes drilled for grouting to foundation.
Maximum height of panel, including the height of
base channel shall be 2450mm. Minimum and
maximum operating heights shall be 300mm and
1800mm respectively. Each feeder compartment
shall have a separate hinged door with rolled
edges with concealed hinges and thumb grip type
screws without any sharp corners to doors.
suitably sized thick non-deteriorating, continuous,
neoprene sponge rubber gaskets shall be
provided all round the perimeter of adjacent
cubicles, between cubicles and baseframe. Cutouts
on front door for mounting lamps, meters,
control switches, handle, etc with inscription plate
for component shall be provided. Undrilled gland
plate of 3mm thick shall be provided on rear TOP of
board cable termination chamber shall be at the rear of
the board
Incoming and outgoing connections from
switching devices shall be brought to the cable
chamber in a staggered manner for cable
terminations. These connections shall be supported
on DMC/ epoxy insulators such that external cables
are not required to be connected directly to the
terminals of switching devices. Detachable barriers of
perforated metal sheet or minimum 4mm thick
non-hygroscopic hylam sheet shall be provided to
prevent accidental contact with any live parts.

Board shall be spray painted after rust removal,


cleaning, rinsing, pickling in acid and phosphatising
treatment on sheet steel with two coats of zinc-rich
primer and two coats of epoxy paint of approved
shade.

Non rusting metallic or PVC engraved label with


proper designation shall be fixed on the front cover
of each compartment, in addition to the name-
plate for entire MCC. The weight and overall
diemensions (LxDxH) MUST be furnished along with
the offer with the details of shipping sections, if
any. Scope of these TWO MCCS shall comply with all
above requirements.

The Contractor shall provide additional spare Contact


in his Panel/Starter for Alarm indicating & connection
for Building Automation System.

The Contact shall be Voltage free as required.

Tenderer shall provide any all suitable cables as required


for respective panels to pump for complete working of
the System at no additional cost. Cables shall be
copper conductor minimum size 3Cx2.5 sq.mm PVCA
1.1 KV grade

Fabricating, Supplying and installing in position sheet


steel wall/clad floor mounting pattern front opening
type control panel.
All the pumps can be selected for off/ manual
position through its manual position its individual
selector switches. In manual position the pump shall
run continuously till switched off. In automatic
position the pump shall start and stop on the level
controllers.

Probe level controllers shall be provided including


necessary cabling from tanks to pumps wherever
necessary.

Vendor shall submit shop drawings for electrical


panel and wiring diagram for approval.

Panel shall be fabricated as per the Drawings furnished


by the Consultants and from their approved Vendor

CONTROL PANEL FOR OVER HEAD FEED PUMPS

Flushing Pumps 1 + 1 x (2.0 H.P. each) No. 1

Raw Water Feed Pumps 1 + 1 x (5.0 H.P. each) No. 1

RO Water Feed Pumps 1 + 1 x (6.0 H.P. each) No. 1

Supply, installation, testing and commissioning of Water No.


Treatment Plant with R.O. - 500 lpm capacity (8 hrs
working). Design to submitted by Vendor based on the
water test report provided by client. Design to be 1
approved by consultant.

Supply, installation, testing and commissioning of Twin Set


Booster pump with 50 ltr tank - 5000 lph @ 20mtr head
capacity each, with control panel. Design to submitted
by Vendor based on the water test report provided by 2
client. Design to be approved by consultant.(1+1)

C - Total Carried Over to Summary


T BENGAL
WORKS

sit insurance (covering unloading as well) etc


e & Handling, Watch and Ward and handing over

il over the other.


ace order directly to primary manufacturers.
ecification will be referred.
ty as per the approved drawing.
payment.

Rate Amount

-
-
-
-

-
-
-
-
-
-
-
-
-
-
-
-

-
-

-
-
-
-

-
-
-
-
-

-
-
-
-

-
-

-
-

-
-
-

-
-
-
-
-
-
-

-
-

-
-
-

-
-

-
-

-
-
-
-
-
-

-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

-
-
-
-
-
-
-
-
-
-
-
-

-
-
-
-
-
-
-
-
-

-
-
-

-
-
-
-

-
-

-
-
-

-
-
-
-

-
-
-

-
-
-
-
-
-

-
-
-
-
-
-
-

-
-
-
-
-
-
-
-

-
-
-
-
-

-
-
-

- water meter

-
-
-
-

-
-
-
-
-
-

-
-

-
-
-
-
-
-
-
-
-

-
-

-
-
-
-
-
-
-
-

-
-
-
-
-
-
-
-
-
-

-
-

-
-
-
-
-
-

-
-
-
-
-

-
-

-
-

-
-
-
-
-
-
-
-

-
-
-
-

-
-
-

-
-
-
-

-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

-
-

-
-

-
-

-
-

-
-

-
-

-
-
-
-

-
-

-
-

-
-

-
-

-
-
-
-
-
-
-
-
-
-

-
-

-
-
PROJECT : Warehousing at Haringhata, West Bengal
SUBJECT: BILL OF QUANTITIES FOR PHE SYSTEM - INTERNAL

A GENERAL NOTES:
I THIS BOQ IS AN INDICATIVE DOCUMENT AND IS TO BE USED AS A TENDERING AID ONLY. THE BOQ DOES NOT CONSTITUTE A
WARRANTY OR REPRESENTATION OF ANY KIND.
II
ALL THE BELOW MENTIONED ITEMS SHALL BE COMPLETED AS REQUIRED BY THE CLIENT / PROJECT -IN- CHARGE & AS PER THE
TECHNICAL SPECIFICATION

B PREAMBLES

All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under “Basis of
Design” in the specifications. Type of equipment, material specification, methods of installation and testing and
type of control shall be in accordance with the specifications, approved shop drawings and the relevant Indian
1 Standards, however capacity of each component and their quantities shall be such as to fulfill the above
mentioned requirement.

The unit rate for all equipment or materials shall include cost in INDIAN RUPEES (INR) for equipment and materials
including taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store
2 at site, storage, installation, testing, balancing, commissioning and other works required.

3 The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise,
include cost of:
All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labor and incidentals
required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion
a) of work called for in the item and as per Specifications and Drawings.

b) Wastage on materials and labor.

Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in
c) position, protecting, disposal of debris and all other labor necessary in and for the full and entire execution and or
the job in accordance with the contract documents, good practice and recognized principles.

d) Liabilities, obligations and risks arising out of Conditions of Contract.

All requirements of Specifications, whether such requirements are mentioned in the item or not. The Specifications
and Drawings where available, are to be read as complimentary to and part of the Bill of Quantities and any work
e) called for in one shall be taken as required for all.

In the event of conflict between Bill of Quantities and other documents including the Specifications, BOQ shall
f) prevail. The interpretation of the Consultant /Project in charge shall be final and binding.

The Contractor shall procure and bring Materials/Equipment to the site only on the basis of drawings approved
4 for construction and shop drawings and not on the basis of Bill of Quantities which are approximate only.

The contractor shall include for making all the opening in slabs, beams, walls etc. as required for his work.
However, the contractor can coordinate with civil work to provide necessary sleeves. All openings shall be closed
5 using water proofing compound, fire sealants or as specified by Project in charge.

The work shall be carried out in conformity with the plumbing drawings and within the requirements of
6 Architectural, HVAC, electrical, structural and other specialized services drawings.

The contractor shall cooperate with all trades and agencies working on the site. He shall make provision for
7 hangers, sleeves, structural openings and other requirements well in advance to prevent hold up of progress of the
construction schedule. All supports to the civil structure shall be provided with anchor fastners.

On award of the work the contractor shall be issued soft copies of consultant’s drawings which shall be the basis
8 of contractor’s shop drawings.

Shop drawings are detailed working drawings coordinated with other trading work, site conditions and
9 incorporate equipment manufacturer’s details and dimensions to ensure that the same can be installed in the
space provided.

All shop drawings should detail pipe routing and levels, showing location of other services at crossings etc., cable
10 runs, route cable trays and all allied works and must be fully coordinated with other services, before execution of
the works.

11 All shop drawings will be made on AutoCAD and color / black & white prints has to be produced for site work.

All rates quoted are inclusive of cutting holes and chases in walls and floors and making good the same with
cement mortar / concrete / water proofing of appropriate mix and strength as directed by the Project incharge.
Contractor shall provide holes, sleeves, recesses in the concrete and masonry work as the work proceeds. All hot
12 and cold water supply pipes crossing masonry walls of typical toilets shall be provided with MS pipe sleeves. The
annular space between the pipe and sleeve shall be filled up with glass wool in between and fire proof sealant on
either end after testing.

The contractor shall , from time to time, clear away all debris and excess materials accumulated at the site failing
13 which the same shall be done by Project incharge at contractor’s risk and cost and cost of clean up shall be
deducted from the contractors pro-rata bill.

After the fixtures, equipment and appliances have been installed and commissioned, contractor shall cleanup the
same and remove all plaster, paints, stains, stickers and other foreign matter or discoloration leaving the same in
14 a ready to use condition.

On completion of all works, contractor shall demolish all stores, remove all surplus materials and leave the site in
a broom clean condition, failing which the same shall be done by the Project incharge at the Contractor's risk and
15 cost. Cost of the cleanup shall be deducted from the contractor’s bills on pro-rata basis in proportion to his
contact value.

ADITHI CONSULTANTS 34
16 Rate to include for testing of all pipes, temporary platforms, erecting & removal of scaffolding.

17 All shaft cut out closing should be considered in civil scope


Base rate given is only for the given Model/fixture. Accessories,
18 consumables, unloading, fixing, installation, commissioning, wastage etc
are part of conversion cost. Also, base Rate is FOR Haringhata site

INSTAKART SERVICES PVT. LTD


CENTRAL KITCHEN AT HARINGATTA, WEST BENGAL
BILL OF QUANTITIES FOR INTERNAL PHE WORKS

SL. NO. DESCRIPTION UNIT QUANTITY RATE (INR) AMOUNT (INR)


D SANITARY FIXTURES AND CP FITTINGS
Supplying, fixing, testing and commissioning, of wall mountedtype
European Water Closet with `P' trap with concealed flushing cistern with
chrome flush plate, dual flush (close coupled, 3 / 6 lts capacity as per IGBC
requirement, with all internal parts of the cistern for efficient functioning)
with matching Heavy duty closing seat cover of approved make, with
1.0 Nos 8.00 -
Galvanised iron chair bracket, fixing of 110mm dia straight type straight
syphon UPVC WC pan connector with neoprene rubber ring, necessary
accessories including cutting & making good the walls, floors, slab
wherever required.(Model : 20098)-
Base Rate for EWC- Rs 7,000 (Model: 20098)
-
Supplying, fixing, testing and commissioning, white colour IWC of depth
350 mm (Orissa Pan) with 'P' or 'S' trap, with cistern (flow rate of 3 / 6 lts
capacity as per IGBC requirement all internal parts of the cistern, 450mm
2.0 Nos - -
long CP inlet connection pipe, 15mm CP angle valve, CP wall flanges,SS
bolts and nuts of approved make etc., complete.(Model : 20070)-
Base Rate for IWC- 2,500 (Model- 20070)
-
Supplying, fixing, testing and commissioning, of 15mm CP ablution tap
( health faucet) of approved make with necessary CP flexible hose 1.0 m
3.0 Nos 8.00 -
long nozzle pipe , CP wall flange Angle valve complete.(Model : F160001)
Base Rate for Health Faucet- Rs 800 (Model : F160001)

-
Supplying, fixing, testing and commissioning, of white colour glazed large
flat back urinals with auto closing concealed flush valve (pressmatic) ,
40mm dia CP waste coupling with dome type grating, 40mm dia CP bottle
trap with extension pipe, urinal spreader, 20mm dia C.P. , SS bolts and
4.0 Nos 6.00 -
nuts to fix the urinal with hangers and brackets complete with wall
flanges.(Model : 96007 & PRS 073)
Base Rate for Urinal- Rs 7,000 (Model : 96007)

-
Supplying, fixing and commissioning of Compressed laminate urinal
partition with 12mm thick high pressure compressed laminate panel as
5.0 per IS:2046 and EN438 all-round polished of size 450x900x12mm thick, Nos 4.00 -
using 2 nos SS clamps embedded in 150 x 150 PCC pocket etc. complete as
directed by Client/Project inchage.
-
Supplying, fixing, testing and commissioning of white glazed Circular /
rectangular wash basin under counter type, pillar cock auto closing
system (pressmatic), with waste coupling,32mm dia CP 'P' trap with
extension, 1no.15mm CP angle valve 1no with 450mm long CP connection
6.0 pipe 1nos and CP wall flanges,etc.,complete. all of approved make Nos 10.00 -
etc.,with all required consumables complete. ( Model : 10080/ 10065 &
PSR-031)
Base Rate for Wash Basin- Rs 4,000 (Model : 10080/10065)

-
Supplying, fixing, testing and commissioning of single lever concealed
divertor unit with over head shower. CP elbow coupling pipe, spout and
overhead shower comprising of CP shower arm, pressure adjustable
7.0 Nos 6.00 -
shower rose with CP wall flanges etc., with all required consumables
complete. (Make : DRC-37229, SPJ-35429pm, & OHS-1709)
Base rate of DRC-37229 Rs 2,000, SPJ- 35429- Rs 2,000)
-
Supplying, fixing, testing and commissioning of storage type water heater
of approved shade with copper container, glasswool insulation,stove
enamelled M.S jacket, thermostatically controlled inner heater with pilot
8.0 neon lamps, angle valve on inlet connection, 15mm dia C.P flexible Nos 6.00 -
connection pipe in inlet & outlet suitable for working pressure of 3
kg/sqcm complete as required (25 lts).
Base Rate of 25 ltr- Water heater- Rs 12,000
-
Supplying, fixing, testing and commissioning of stainless steel towel ring
9.0 with nickel chrome finish, complete. (Model - F880007CP) Nos 10.00 -
Base Rate of Towel Ring- F880007CP- Rs 600
-
Supplying, fixing, testing and commissioning of stainless steel tissue

10.0 dispenser with nickel chrome finish, complete (Model No- F880003CP) Nos -
Base Rate of Tissue Dispenser- F880003CP- Rs 1,000

ADITHI CONSULTANTS 35
SL. NO. DESCRIPTION UNIT QUANTITY RATE (INR) AMOUNT (INR)
Supplying, fixing, testing and commisioning of 15 mm dia C.P. brass tap
11.0 with C.P. wall flange of approved quality and making good as required Nos 4.00 -
including, IWC & Janitor room etc
-
Supplying, fixing, testing and commissioning of counter mounted type
soap dispencer with nickel chrome finish, complete (Model No-
12.0 Nos 10.00 -
F840006CP)
Base Rate of soap Dispenser- F840006CP- Rs 1,000
-
Supplying, fixing, testing and commissioning of Auaguard unit with all
13.0 Nos 2.00 -
inlet/outlet with connections all complete. (for Kitchen)
-
Supplying, fixing, testing and commissioning of 20mm dia. x 600mm long
14.0 C.P. stainless steel towel rods fixed to wooden plugs with CP Nos 6.00 -
screws,brackets,all complete.(in Shower)
-
Supplying, fixing, testing and commissioning of off white vitreous china

15.0 recessed type soap dish including making the necessary cut-outs for Nos 6.00 -

recessing, grouting the soap dish complete as directed (in Shower)


-
Supplying, fixing, testing and commissioning of C.P. open type toilet paper
16.0 holder recessed type 200 x 150mm, including fixing the same with C.P. Nos 8.00 -
screws complete. (near WC)
-
Supplying, fixing, testing and commissioning of robe hooks (double)
17.0 Nos 8.00 -
including fixing the same with CP screws complete. (near WC)
-
Total D - Carried to Summary -
-
E INTERNAL SEWAGE SYSTEM - SOIL & WASTE -
Supplying, fixing and testing PVC pressure pipes class 3, 6Kg/sqcm
confirming to IS4985 for waste water connection from AC indoor units,
wash basin,kitchen sinks to floor traps with solvent cement joints,
including all the necessary fittings such as elbow, tee, Y bend, shoes, and
1.0 -
bushes etc complete.,laid concealed in wall etc, the work shall include wall
chase and making good the same in cement mortar and restore the same
original condition neatly as directed by the Engineer in-charge
etc.,complete with necessary signages.
1.1 Internal toilets -
32 mm dia RM 250.00 -
a) 40 mm dia RM 100.00 -
b) 50 mm dia RM 10.00 -
-
Providing, fixing, jointing and testing uPVC low noise silent SWR pipes and
pushfit fittings (above 75 mm dia and less than 200mm dia) conforming to
EN 12056:2000, IS 13592:2013 (for pipes) and IS 14735:1999 (for fittings)
with sound insulation as per EN 14366), including all necessary GI fittings
and specials such as bends, tees, unions, reducers, flanges & plugs etc.
Fixing at wall / ceiling level, hangers etc. as per specification. In gradients
2.0 -
and alignments as approved complete, fixed to walls or ceiling or run on
floor or in trenches supported by clamps at required slopes as directed
after testing hydraulically and making good walls / surfaces, etc. Cost
shall be inclusive of clean out plugs. Rubber lined galvanised steel clamps
and brackets. The diameter of pipe shall be of the following nominal bores
(NB):
2.1 Internal toilets -
a) 75 mm dia RM 60.00 -
b) 110 mm dia RM 1,116.00 -
160 mm dia RM 760.00 -
-
2.2 Shaft Piping - Vertical Header -
a) 75 mm dia RM 75.00 -
b) 110 mm dia RM 160.00 -
160 mm dia RM 15.00 -
-
Supplying, fixing and testing of Air Admittance Valves & fittings for vertical
3.0 stack of pipe including cuting pipes to required length, and fixing in chases -
or surface mounted with clamps
a) Air Admittance Valve (Maxi Vent) Nos. -
-
Providing and fixing C.P. Brass heavy quality gratings (3mm thick/SS)
for floor drains including making necessary recessment grouting with
neat cement all complete to the satisfaction and direction of the of the -
Engineer-in-charge.

150mm round/square Nos. 240.00 -


-
Providing and fixing UPVC. heavy approved Nahani Traps with
minimum 50mm seal including fixing the same with the solvent cement
joints complete to the satisfaction and direction of the Engineer-in- -
charge.

150mm round/square Nos 18.00 -


-
Providing and fixing vent cowls including fixing the same with ring
fittings joint complete as per specifications and directions of the -
Engineer-in-charge.
110mm dia Nos 2.00 -
80mm dia Nos 2.00 -
-

ADITHI CONSULTANTS 36
SL. NO. DESCRIPTION UNIT QUANTITY RATE (INR) AMOUNT (INR)
Providing and fixing SS heavy quality gutter gratings (3mm thick/SS)
100mm deep with SS Trough for floor drains including making necessary
recessment grouting with neat cement all complete to the satisfaction -
and direction of the of the Engineer-in-charge.

1200mm long x 275mm wide Nos 140.00 -


-
Providing and fixing C.P. Brass heavy quality gratings (3mm thick/SS)
for floor drains including making necessary recessment grouting with
neat cement all complete to the satisfaction and direction of the of the -
Engineer-in-charge.

300mm round/square (for terrace RWP) Nos. 16.00 -


-
Supplying, fixing and testing PVC deep seal self cleaning "P" trap with SS
4.0 frame and cover 110 mm dia outlet with cockroach trap fixed on a bed of -
cement concrete with (Heavy duty type) etc., complete.

a) 110mm dia Nos. 222.00 -


-
Supplying, fixing and testing clean out plugs, supports as with suitable GI
U-clamps, bolts, nuts and washers etc., The clamps shall be painted with
5.0 two coats of enamel (approved) paint over a coat of primer etc., complete. -

a) 110 mm dia Nos. 60.00 -


-
Total E - Carried to Summary -

F INTERNAL WATER SUPPLY SYSTEM - DOMESTIC, FLUSHING & HOT


WATER -
-
Supplying, installing, fixing, jointing, testing and commissioning of
approved make. Chlorinated Polyvinyl Chloride pipes (CPVC) SDR.11 pipes
confirming to ASTM standards with necessary fittings for internal toilet
water supply upto 50 dia , and above 50mm dia pipe schedule 80 with
fitting shall be schedule 80 ASTM IPS. The fittings and specials such as
tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded
combination / transition specials such as male adapters brass threaded
female adapters, brass FPT Tee, Brass FPT elbow etc., where connection
with metal is to be made including necessary drilling holes, chasing walls
and making the same good in cement mortar 1:1 restore the same original
condition neately as directed by the Engineer in-charge. Joints to be made
with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above
50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724.The
1.0 rate shall include necessary GI supports, GI grip bolts, angle brackets, -
hangers, supports as with suitable GI U-clamps, bolts, nuts and washers
etc all as per E-I-C's requirement.The clamps shall be painted with two
coats of enamel (approved) paint over a coat of primer etc., complete.
All nuts, bolts, washers, unions shall be hot dip galvanised.
(Domestic water supply system)

a) 20 mm dia RM 870.00 -
b) 25 mm dia RM 240.00 -
c) 32 mm dia RM 120.00 -
d) 40 mm dia RM 40.00 -
e) 50 mm dia RM -
-
Supplying, Installing, Testing & Commissioning at site in position PERT
pipes (PN 20) confirming to ISO:22391-2:2009 of approved make for Hot
water supply pipes @ 70 degrees, jointing by electro fusion welding or
with push fit fittings (PN 20) (elbows, unions, tees, reducers, couplings,
nipples etc.) complete with clamping in position with G.I. "U" bolts (8 mm
2.00 thick) on G.I. slotted rails (1.6 mm thick), Rail legs (2.5 mm thick) with -
rubber lining of approved make, as per drawings to the satisfaction of the
Project Manager.

65mm dia. (HWS Terrace loop) RM 400.00 -


50mm dia. (HWR / HWRRTerrace loop) RM 800.00 -
40mm dia. RM 20.00 -
32mm dia. RM 100.00 -
25mm dia RM 230.00 -
20mm dia. RM 800.00 -
-
Providing insulation to pipes by wrapping with K-flex insulation of 6mm
with tapeing all complete. -
20mm - 40mm dia. RM 1,150.00 -
50mm - 100mm dia. RM 1,200.00 -
-

ADITHI CONSULTANTS 37
SL. NO. DESCRIPTION UNIT QUANTITY RATE (INR) AMOUNT (INR)
Supplying, installing, fixing, jointing, testing and commissioning of
approved make. Unplasticized Polyvinyl Chloride pipes (uPVC) Sch 40 pipes
confirming to ASTM standards with necessary fittings for internal toilet
water supply upto 50 dia, and above 50mm dia pipe schedule 80 with
fitting shall be schedule 80 ASTM IPS. The fittings and specials such as
tees, elbows, couplers, bends, enlargers etc.,with PVC brass threaded
combination / transition specials such as male adapters brass threaded
female adapters, brass FPT Tee, Brass FPT elbow etc., where connection
with metal is to be made including necessary drilling holes, chasing walls
and making the same good in cement mortar 1:1 restore the same original
condition neately as directed by the Engineer in-charge. Joints to be made
with PVC solvent cement up to 50mm dia as per ASTM D-2846 and above
50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 . The
3.0 rate shall include necessary GI supports, GI grip bolts, angle brackets, -
hangers, supports as with suitable GI U-clamps, bolts, nuts and washers
etc., .The clamps shall be painted with two coats of enamel (approved)
paint over a coat of primer etc., complete.
All nuts, bolts, washers, unions shall be hot dip galvanised.
(Flushing water supply system)

a) 20 mm dia RM -
b) 25 mm dia RM -
c) 32 mm dia RM -
b) 40 mm dia RM -
b) 50 mm dia RM -
-
Supplying & fixing Auto Air vent with in-built brass ball valve for water
4.0 supply risers, suitable for pressure not less than 15 Kg/Sq.cm. -
a) Air release valve size- 20mm Nos. -
-
Providing, fixing, jointing and testing, PN10 forged brass ball valves F/F
screwed end with SS lever operated of approved make, including flanges /
unions, nuts, bolts, washers, etc. complete, as approved by the Architect
5.0 -
and Engineer-in-charge for water supply lines of the following nominal
bore (NB) size:
All nuts, bolts, washers, unions shall be hot dip galvanised.
a) 20 mm dia Nos. 75.00 -
b) 25 mm dia Nos. 30.00 -
c) 32 mm dia Nos. 20.00 -
c) 40 mm dia Nos. 20.00 -
c) 50 mm dia Nos. 10.00 -
-
Total F - Carried to Summary -

ADITHI CONSULTANTS 38
LIST OF RECOMMENDED MAKES

SL NO DESCRIPTION MAKE
1 SANITARY WARE HINDWARE or equivalent
2 CP FITTING JAQUAR /CERA/KOHLER
3 CPVC PIPES & FITTINGS ASHIRVAD / ASTRAL / SUPREME
4 NU DRAIN PIPES (RING) ASHIRVAD / ASTRAL / SUPREME
5 DWC PIPE ASHIRVAD / ASTRAL / SUPREME
6 GI PIPES - C CLASS JINDAL HISSAR/TATA
7 VALVES AND STRAINERS NVR / CRI / RB / ITAP
8 AIR RELEASE VALVES WATTS / CRI / HAWA / ITAP
PIPE PROTECTION TAPE (PVC)
9 UNDERGROUND PYPCOAT / TWL / RUSTECH

10 PIPE PROTECTION TAPE (CONCEALED) TAPEX or equivalent


11 TOILET CUBICLE STELATEX or equivalent.
12 COMPRESSED LAMINATE MERINOX or equivalent.

You might also like