Industrial Pressure Transmitters Type S-10 - Vacuum To 60,000 PSI

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Industrial Pressure Transmitters

Type S-10 - Vacuum to 60,000 PSI

Tronic (Previous model numbers 891.13.500, 891.23.510)

• Standard ranges available from stock


• 4-20 mA 2-wire output signal, others available
• Highly resistant to pressure spikes and vibration
• Stainless steel case and wetted parts
• Can be assembled to chemical seals
WIKA S-10 pressure transmitters and transducers are precision engineered to fit most
industrial pressure measurement applications. Each unit undergoes extensive quality
control testing and calibration to achieve an accuracy < 0.25% full scale. The printed
circuit boards use state-of-the-art surface mount technology and are potted in silicone
gel for protection against mechanical shock, vibration, and moisture. Each unit is
temperature compensated to assure accuracy and long term stability when exposed
to severe ambient temperature variations.

The compact design provides a rugged transmitter suitable for many applications in
hydraulics and pneumatics, vacuum, test equipment, liquid level measurement, press
control, compressor control, pump protection and numerous other processing and
control operations.

STANDARD RANGES
RANGE MAXIMUM* B URST** RANGE MAXIMUM* B URST**
30"-0 HgVac 70 PSI 70 PSI 0-250 PSI(A) 1100 PSI 1100 PSI
30"-0-30 PSI 250 PSI 250 PSI 0-300 PSI 1100 PSI 1100 PSI
30"-0-60 PSI 500 PSI 500 PSI 0-400 PSI 1100 PSI 3600 PSI
30"-0-100 PSI 500 PSI 500 PSI 0-500 PSI(A) 1100 PSI 5800 PSI
30"-0-160 PSI 500 PSI 500 PSI 0-600 PSI 1100 PSI 5800 PSI
30"-0-200 PSI 1100 PSI 1100 PSI 0-750 PSI 1100 PSI 5800 PSI
0-50 INWC 30 PSI 30 PSI 0-1000 PSI 1750 PSI 8000 PSI
0-100 INWC 30 PSI 30 PSI 0-1500 PSI 2900 PSI 11,600 PSI
0-5 PSI 30 PSI 30 PSI 0-2000 PSI 4600 PSI 14,500 PSI
0-10 PSI 60 PSI 60 PSI 0-3000 PSI 4600 PSI 14,500 PSI
0-15 PSI(A) 70 PSI 70 PSI 0-5000 PSI 11,600 PSI 25,000 PSI
0-25 PSI(A) 145 PSI 145 PSI 0-8000 PSI 17,400 PSI 35,000 PSI
0-30 PSI 145 PSI 145 PSI 0-10,000 PSI 17,400 PSI 35,000 PSI
0-50 PSI(A) 250 PSI 250 PSI 0-15,000 PSI 21,750 PSI 43,500 PSI
0-60 PSI 250 PSI 250 PSI 0-25,000 PSI 29,400 PSI 58,800 PSI
0-100 PSI(A) 500 PSI 500 PSI 0-40,000 PSI 44,100 PSI 73,500 PSI
0-160 PSI 500 PSI 500 PSI 0-60,000 PSI 65,000 PSI 102,900 PSI
0-200 PSI 500 PSI 500 PSI

Notes:
* Maximum pressure, causing no permanent changes in specifications but may
lead to adjustable zero and span shifts.
** Burst pressure, leading to destruction of transmitter.
(A) Standard ranges available with absolute pressure reference.
APE 81.01

File Name: Wika Industrial Pressure Transmitter Type S-10 (5-00)


S p ec i f i c at i o n s Un its Ty p e S-10
Sensing principle piezoresistive up to 300 PSI, thin film > 400 PSI
Pressure ranges PSI standard ranges as listed {custom ranges available}
Pressure reference relative pressure {absolute reference to 500 PSIA}

P r es s u r e c o n n ec t i o n
for ranges < 15,000 PSI: 1/2" NPT male; (1/4"NPT male, G1/2B, G1/4B)
{SAE #4 (7/16-20 UNF) male O-ring boss for ranges > 400 PSI}
for ranges > 15,000 PSI: F-250-C autoclave (9/16-18 UNF)
{other pressure connections available}

Mat er ial:
-wetted parts 1.4571 and 1.4542 stainless steel (316 ss and PH17-4 ss)
{for other materials see WIKA chemical seals}
-case 1.4301 stainless steel (304 ss)
-internal transmitting liquid silicone oil for piezoresistive sensors to 300 PSI, {halocarbon oil for oxygen
service}, no liquid fill used for thin film sensors > 400 PSI

Su p p ly v o lt ag e UB DC Volts 10 - 30 (14 - 30 for 0 - 10 V output signal)

Ou t p u t an d lo ad lim it at io n s :
Output signal and maximum load 4-20 mA 2-wire system RA[Ohm] < (UB [V] -10V) / 0.02 A
{0-20 mA 3-wire system} RA[Ohm] < (UB [V] -10V) / 0.02 A
{0-5 V 3-wire system} RA> 5 kOhm (min)
{0-10 V 3-wire system} RA> 10 kOhm (min)
{other signal outputs available}

Response time (10...90%) milliseconds <1


zero and span adjustment % +10

Ac c u r ac y ( linearity, including hysteresis % o f sp a n <0.25% (B.F.S.L.) {0.125%} 1 (Calibrated in vertical mounting position
and repeatability ) with process connection down)

Repeatability % o f sp a n < 0.05


Hysteresis < 0.1

1 year stability % o f sp a n < 0.2 (under reference conditions)

Tem p er at u r e
Media -22oF to +212oF (-30oC to +100oC) { -40oF to +257oF (-40oC to +125oC)}
Ambient -4oF to +176oF (-20oC to +80oC)
Storage -40oF to +212oF (-40oC to +100oC)
Compensated range +32oF to +176oF (0oC to +80oC)

Temperature error (reference 70oF)


on zero point % o f sp a n < 0.2 per 18oF (10oC) change (< 0.4 per 18oF for ranges < 100 INWC)
o n sp a n < 0.2 per 18oF (10oC) change

Interference emission per EN 50 081-1 (March 1993) and EN50 081-2 (March
CE
CE conformity 94), Interference immunity per EN 50 082-2 (March 1995)

Shock resistance g 1000 per IEC 770 for mechanical shock


Vibration resistance g 50 per IEC 770 for vibration under resonance conditions

Electrical connection 4-pin L-plug per DIN 43 650 with solderless screw terminal and PG 13 fitting
{4- pin L-plug with 1/2" female conduit opening, 5 foot vented flying lead, 4 or 6
pin MIL plug} {custom plug and cable assemblies}

Weight lb approximately 0.4 (0.2 Kg)


Dimensions see drawing

Electrical protection protected against reverse polarity, short circuit, and overvoltage

Environmental protection IP 65 (NEMA 5) with 4 pin L-plug, MIL plugs


{IP 67 (NEMA 4) with 5 foot flying lead}
{IP 68 (NEMA 6) submersible with cable and special case}

Notes: Items in curved brackets { } are available as special order options


1
improved accuracy available with pressure ranges > 100 INWC
Dimensions Optional process connections
1/4 NPT male SAE #4 male O-ring boss
(for ranges from 400 to 15,000 PSI)

1.06” (27mm) 1.06” (27mm)

(9.14)
.36”
(13)
.51”
G1/4B BSP G1/2B BSP
A 1.06” (27mm)
1.06” (27mm)

1.06"

Key Description Dimension


Standard case 3.25" (82mm) metric connections
A Long case 4.33" (110mm) shown in mm

Case length supplied depends


upon special order options.
For non- clogging flush diaphragm
process connections see Type S-11
on data sheet APE 81.02

Electrical connections
Standard

Attachable LCD Vented cable with Snap CapTM with


Ty p e DIN 43 650 plug
Display free ends terminal block
MIL plug

P r o t ec t i o n IP 65 / NEMA 5 IP 65 / NEMA 5 IP 67 / NEMA 4 IP 67 / NEMA 4 IP 65 / NEMA 5

PG9 cable gland PG 11 cable 4 - pi n


(standard) Loop powered 5 foot - #9744479 gland, 4-20 mA PT02E-8-4P
D es c r i p t i o n Part # 1006711 programmable 10 foot - #9838915 Part # 2130017 Part # 8990935
an d p ar t 4-20 mA 20 foot - #4239904
n u m b er s 1/2" NPT female 3.5 digit 30 foot - #4239921 1/2 NPT female 6 - pi n
conduit opening Part # 4210069 50 foot - #4293348 conduit, 4-20 mA PT02E-10-6P
Part # 1632159 Part # 4260261 Part # 9744460
Wiring
2-wire system
DIN 43 650 plug MIL-plug PT 02 E-10-6P flying lead
UB+/S+ UB+/S+ brown UB+/S+ (1)

0V/S- 0V/S- green 0V/S- (2)

3-wire system
DIN 43 650 plug MIL-plug PT 02 E-10-6P flying lead
UB+ UB+ brown UB+ (1)

S+

white S+ (3)
S+

0V/S- green 0V/S- (2)


0V/S-

2 -w ire sy s tem 3-wire system

DIN Wire DIN Wire


Wire Co din g Plu g C olor Wire Coding Plug Color

S upp ly + U B+ / S + pi n 1 brown Supply + UB + pin 1 brown

S ig nal - 0V / S- pi n 2 g re en Supply -
0V / S- pin 2 green
Signal -

Signal + S+ pin 3 white

Zero Span
Calibration adjustment adjustment

Remove the electrical connector and retaining ring.


Carefully pull the connector plate from the transmit-
ter body. Attach a meter and power supply to the
electrical connector. For gauge ranges the zero
potentiometer can be adjusted to produce a null
output when no pressure is applied. Span adjust-
ment requires the use of a reference pressure
source. Compound and absolute ranges require a
vacuum and pressure source. When calibrated,
reassemble connector, taking care not to pinch the
wires between the case and connector plate.
Electrical
connector

THE MEASURE OF
Total Performance TM

Ordering Information:
State computer part number (if available) / type number / size
/ range / connection size and location / options required. WIKA Instrument Corporation
1000 Wiegand Boulevard
Specifications given in this price list represent the state of engineering at the time of printing.
Modifications may take place and the specified materials may change without prior notice Lawrenceville, Georgia 30043-5868
Tel: 770-513-8200 Fax: 770-338-5118
http://www.wika.com e-mail: info@wika.com