Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

EDMI Mk 10

Electricity Meter
Atlas Series Class 1 and Class 2
The Mk10A is a member of our Atlas series.
User Guide to LCD
Apolyphase meter with CT connected or
Whole Current measurement options, it
Screen Displays
includes power quality indication, advanced
commissioning functionality and a large
memory storage

Energy Assets
Tel: 01506 405 405
bringing meters to life... energyassets.co.uk
Downloaded from www.Manualslib.com manuals search engine
EDMI Mk 7C Electricity Meter

1.0 INTRODUCTION 2.0 ACCESS TO DISPLAY SCREENS


The EDMI Mk10 meter is a new development of ‘Smart’ metering Access to all the features of the meter
used to measure Electricity consumption. It is a unique product only requires the pushing of a single
which enables energy usage to be continually measured and ‘display’ button on the meter. The
stored and then data is transmitted to the Supply Company when meter has two main displays called
needed for billing. The meter has a large number of features, readily ‘Set A’ and ‘Set B’. To move from ‘Set
available, to provide Users with detailed information about their A’ to ‘Set B’ you simply press and hold
electricity supply including Tariff (Standard Settlement the ‘display’ button for approximately 2
seconds.
Configuration - SSC), Power Factor, Maximum Demand and Total
Billing Consumption together with individual Rate consumption for Details of all the individual LCD
consumers on multi rate tariffs. screens within each ‘Set’ are shown on
the following pages.
In addition, there is an option to obtain analysed billing data
information via a web link. Users can then see a detailed breakdown To cycle within the ‘Set’ you simply
of their energy usage and time of use to enable any unplanned press the display button and the
wastage to be eliminated and help manage more efficient usage, as display will advance one step.
part of an energy management process.
Continual individual presses of the
button will eventually cycle the display
back to your starting point.

3.0 THE SCREEN WITH ALL SEGMENTS ILLUMINATED

1 INDICATES POWER FLOW 1 2 3 4 5 6 7


+ P = Import Kw
- P = Export Kw
+ Q = Import kVar (Lag)
- Q = Export kVar (Lead)
2 REGISTERS DISPLAYS
S et A (Main)
R1 R2 R3 R4 R5 R6 Spare Spare Spare? MP AL1A L2
S et B (Test)
3 PHASES PRESENT ON METER Spare
Wh Pulse Varh Pulse Spare
4 LOW BATTERY
8 9 10 11 12
5 LOCAL COMMS IN USE
( Flag Probe)
FLAG LETTERS ALARM NAME
6 REMOTE COMMS IN USE
E ANALOG REFERENCE FAILURE
( eg Modem) S ASYMMETRIC POWER
V VOLTAGE TOLERANCE ERROR
7 UNITS BEING MEASURED
F VT FAILURE
8 RATE REGISTERS IN USE R INCORRECT PHASE RESOLUTION
C CLOCK FAILURE
9 INCORRECT PHASE ROTATION M REVERSE POWER
L CALIBRATION DATA LOST
10 M ODEM POWERED H MODEM FAILURE
11 ACTIVE ALARMS X RAM FAILURE OR LCD FAILURE
Y PROGRAM FLASH FAILURE
( will clear as fault corrected eg Phase Fail) Z DATA FLASH FAILURE
N PULSING OUTPUT OVERFLOW
12 L ATCHED ALARMS D BATTERY FAILURE
( only cleared with fault manufacturer U TAMPER
software)

Energy Assets
Tel: 01506 405 405
bringing meters to life... energyassets.co.uk
Downloaded from www.Manualslib.com manuals search engine
EDMI Mk 7C Electricity Meter

3.1 SET A - METER READING INFORMATION

Please note that the display will normally cycle around each item in turn automatically
every 10 seconds (for reading purposes)

Current Time (GMT)

Current Date
(26th May 2009 Shown)

Rate 1 R1
(Meter Reading) R2
Please note that for multi-tariff meters the meter register will be the only one displayed

Total kWh
(Meter Reading)
S

Please note that for multi-tariff meters the meter register will be the only one displayed

kVArh Lag
(Sine Meter Reading)
KV

Please note that for Users on non MD Tariffs some of the display registers shown
are not applicable to your tariff and will therefore not be displayed

kVAh KZ
(Apparent Energy Meter Reading)

Maximum Demand in kW
(Highest Demand since last reset)
MD

Maximum Demand in kVA


(Highest Demand since last reset)
MZ

Previous MD in kW

Energy Assets
Tel: 01506 405 405
bringing meters to life... energyassets.co.uk
Downloaded from www.Manualslib.com manuals search engine
EDMI Mk 7C Electricity Meter

3.1 SET A - METER READING INFORMATION

Please note that the display will normally cycle around each item in turn automatically
every 10 seconds

Previous MD in kVA

Billing Reset
(Count of Resets)

Billing Reset
(Date)

Please note that for multi-tariff meters the meter register will be the only one displayed

Billing Reset
(Time)

Tariff & Meter Serial Number


(eg SCC 0244 & E07BG04061)

Indicates the start of the Meter Serial


Number which scrolls across the LCD

MPAN
(eg 1600000000283)

Indicates the start of the MPAN


which scrolls across the LCD

Test Display
(All segments illuminated)

This is the last display in ÔSETAÕ before reverting

Energy Assets
Tel: 01506 405 405
bringing meters to life... energyassets.co.uk
Downloaded from www.Manualslib.com manuals search engine
EDMI Mk 7C Electricity Meter

3.2 SET B - TEST / SUPPLEMENTARY INFORMATION

Signal Strength

Alarm Status Flags

Indicates the start of the Alarm Codes


which scroll across the LCD

FLAG LETTERS ALARM NAME

E ANALOG REFERENCE FAILURE


V VOLTAGE TOLERANCE ERROR
C CLOCK FAILURE
M REVERSE POWER
L CALIBRATION DATA LOST
H MODEM FAILURE
X RAM FAILURE OR LCD FAILURE
Y PROGRAM FLASH FAILURE
Z DATA FLASH FAILURE
N PULSING OUTPUT OVERFLOW
D BATTERY FAILURE
U TAMPER

Current
(Phase Current RMS)

Voltage
(Phase Voltage RMS)

Energy Assets
Tel: 01506 405 405
bringing meters to life... energyassets.co.uk
Downloaded from www.Manualslib.com manuals search engine
EDMI Mk 7C Electricity Meter

3.2 SET B - TEST/SUPPLEMENTARY INFORMATION

Power Factor (PF)


(-ve for Lag +ve for Lead)

Total Active Power kW


(+P for Import -P for Export)

Total Reactive Power kVAr


(+Q for Import -Q for Export)

Total Apparent Power kVA


(+P for Import -P for Export)

Manufactures Serial Number

This is the last display in ÔSET BÕ


. The meter should
automatically to ÔSETAÕ after approximately 45 seconds
if no further keys are pressed. Alternatively you can
force it back to ÔSETAÕby pressing the ÔSELECTÕ bu tton
for 2 seconds

Energy Assets
Tel: 01506 405 405
bringing meters to life... energyassets.co.uk
Downloaded from www.Manualslib.com manuals search engine

You might also like