Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

ZP LCD

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Changzhou Zhipu Electronics Co.

,Ltd

LCD Manual Control Panel Instructions


2013 Latest Version

:861-A
Item No:
:DC24V 36V(
Working Voltage: (Setting of the meter)

(According to customers’ requires to
48V(
customized))


Mode of connection:
(D+)
1. Red Line( ):Enter of the power’s plus
(GND :Power’s minus
2. Black Line(
(DS :Controller electric door lock
3. Blue Line(
(DD+ :Lighting control’s plus(If the controller’s software
4. Yellow Line(
and hardware support the lighting control’s line,this yellow line won’t
connect)
(DAT)
5. Green Line( ):Received the communication
(TX :Send the communication
6. White Line(
:PWM type of voltage assistance gear’s control、
7. Extended Function: 、
Independent of speed sensor

Function::
.Function of display
1.
Speed 、 Assistance
display、 、Battery
display、 、Problems
indicator、
prompt、、 Mileage 、 Accumulative mileage 、 Cruise constant speed 、
Braking indicator、、Headlight display
.Function of Control and Setting
2.
Power switch control、、Front light switch control、
、6Km/h inching
、 Real time cruise control、
control、 、Wheel diameter’s setting、
、5 mode
、Highest speed setting、
assistance’s setting、 、Automatic dormancy time
、 Backlight brightness setting、
setting、 、startup mode、、 drive mode is
、power sensitivity setting、
set、 、 dynamical disk type、
、 voltage grade
、 controller set current limiting values
setting、
.Communication Protocol:
3. :UART
All The Content On The Display Screen(Opened In One Second)

Introduce of Display Content

1. Headlight

2. Current Status Grade This function need


controller’s software support

3. Voltage Status Grade POWER


4. Display of Multifunction Area
、Once Mileage(TRIP)、
Total Mileage(ODO)、 、Digital
、Digital
Voltage(VOLT)、
Current(CURRENT) 、 Surplus Mileage(Need battery protective plate’s
、Runtime(TIME)
software support)(RM)、

5. Display of Speed Area


Average Speed、 、Max Speed 、AVG
Unit: MPH, KM/H
Speed has 4 ways to come true ,depending on the specific way ,
partial way could compose.
1. Hall signal attaching electric motor
2. Controller send Hall signal of motor to meter
3. slow speed Hall signal as the type run a circle.
4. Controller send signal of slow Hall signal as type run a circle to
meter.
: 1MS )
(single Hall cycle, Unit:
The meter could calculate true speed according to the data of wheel
diameter and the signal’s data (electric motor’s Hall need to set up the
magnet steel’s quantities)
6. Malfunction Status Display Area

Motor stoppage 、throttle stoppage 、controller stoppage 、

power brake handle 、Under Voltage Protector

.Assistance status display area


7.

Assistance status 、Cruise marks


(1-5 gear)、

8. Set
P01: :Backlight lamp brightness, level 1 is the most dark, level 3 is
the brightest;
P02: :Unit mileage, 0: KM;1: the MILE;
P03: :Level of voltage: 24 v, 36 v, 48 v, 36 v (by default);
P04: :Sleep time: 0, means don't sleep;Other Numbers means for
the sleep time,
range: 1-60;Units of minutes;
P05: :Assistance gears:0, 3Mode: :1lever 2V、、2lever 3V、 、3lever 4V;
1, 5Mode: :1lever 2V、 、2lever 2.5V、 、3lever
3V、、
4lever 3.5V、、5lever 4V;
P06: :Wheel diameter: unit, inch;Accuracy: 0.1;
P07: :Speed measuring magnetic steel number: range: 1-100;
P08: :Speed: the range 0 to 50 km/h;The default 50, 50 said not the
speed limit;
Note::when the speed is greater than the set speed, shut off the
PWM output;When speed down to less than the set speed,
automatically open the PWM output, driving speed to the
current + 1 km/h;
Numerical based on km as a benchmark here, after the unit set
from miles to miles, display the speed of numerical value is
automatically converted to the correct miles, but miles under
the interface of the menu in the values of speed limit set by the
data conversion, MPH speed limit values are not consistent
with the actual display,
P09::Zero start, non-zero start setting, 0:0 start;1: the non-zero
:Driving mode setting 0: power drive (decided how much
start; P10:
output power by power gear, at this time to turn the
invalid).
1: electric (by going to drive, steering gear
is invalid at this time).
2: power drive and electrical drive
coexist (electric zero start state is invalid).
:Power sensitivity setting range: 1-24;
P11:
:Assistance start the intensity setting range: 0-
P12:
5;
:Power magnetic steel plate type 5 Sherwin grain of magnetic
P13:
steel three types;
:Controller for the current limit value to set,12A(by default)
P14:
range: 1 - 20 A;

Ⅱ. Button Introduction:
Specific buttons position as bellow:

Button’s Design Introduction


Button operation includes short-time press, long-time press and
combination buttons long-time press.

Short-time press used in quickly/frequently operation, such as:

1. During riding, press shortly to change


assistance/speed gear.

2. During riding, press shortly to switch the multifunctional


area to display data.
Press single button for long time is mainly to switch the
mode/button status.
Press combination button (for long time) is mainly used for
parameter setting, which could reduce maloperation due to
complicated operation.
(No combination buttons with short-time press, as they are too difficult
to operate due to they are easy to be triggered by mistake).


Explain of Specific Operation:

Ⅰ.Shift to assistant/electric gear,


Suppose current condition is assistance mode,
1)shortly press , assistance + 1
2)shortly press ,assistance - 1

Ⅱ.shift speed display

Extended press to shift the way of speed display


Ⅲ.set/ release the condition of 6km/h cruise、
、real time cruise,on/off light

When the e-bike is stops,extended press ,you can get into the
6KM/h cruise mode. When the e-bike is running, extended press

,you can get into the real time cruise mode. If just now you are in
cruise mode, the mode will be released.

Shortly press to turn on/off light.


Ⅳ.Turn on/off LCD screen

If current display screen is working, extended press ,the screen


will be off, otherwise, the screen will be on.
Ⅴ.Shift to multifunctional display version,

Shortly press , you can shift the value on multifunctional display


version.
Ⅵ.parameter setting

Press + and hold, get into the version of parameter


setting, then you can set up parameters bellow,wheel diameter (unit:
inch), magnet steel number,LCD brightness, under-voltage point etc.(
See Settings: P01 - P14)

Under the set interface,you could shortly press or to


add or subtract the value, after modified the parameters ,it will be
shine,after you choose the assumed value,
1. Press shortly to save current value,parameters shine will be
stop .

2. Press + ,save setting, if didn’t press, it will be

automatically save and exit after 10 seconds to modify parameters

Note : according to upgrading of our products, there may be some


differences between product introduction and products you received.
The differences would not influent your daily usage.

ADD:No.188 Renmin west road,Niutang Town,Shijia


Village,Wujin District,Changzhou,Jiangsu,China
TEL:0519-86959801
FAX:0519-86959601
http:www.chinazipu.com
http://chinazipu.cn.alibaba.com/

You might also like