PEM-02 ELECTROMAGNETIC RELAY

INSTRUCTION MANUAL

Zakład Mechaniki i Elektroniki


ZAMEL sp.j.
J.W. Dzida, K. Łodzińska

ul. Zielona 27, 43-200 Pszczyna, Poland


Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: marketing@zamel.pl

DESCRIPTION TECHNICAL DATA

Electromagnetic relays may be used in PEM-02


various applications where load current /012 /024 /048 /110 /230
increase is needed. The relays assure Input (supply) terminals: A1, A2
voltaic insulation between a control unit Input rated voltage: 12 V AC/DC 24 V AC/DC 48 V AC/DC 110 V AC/DC 230 V AC
and a load circuit. The relays are fitted Input voltage tolerance: -15 ÷ +10 %
with NO / NC dead contacts. It is possible Nominal frequency: 50 / 60 Hz
to connect voltage of 0 ÷ 250 V AC to the Rated current: 34 mA AC 15,2 mA AC 8 mA AC 4,5 mA AC 21,5 mA AC
contacts. Output switch on indicator: LED red
Output (load) terminals: 11, 12, 14 and 21, 22, 24
Control element: 2 x NO/NC - 8 A / 250 V AC
Numer of terminal clamps: 8
FEATURES Section of connecting cables: 0,2 ÷ 2,5 mm2
Ambitne temperature range: -20 ÷ +45 oC
Operating position: free
● Load current increase,
Mounting: TH 35 rail (PN-EN 60715)
● Capability of changing motor
Protection degree: IP20
rotation directrion by means of two
dependent and separated contacts, Protective class: II

● Applicable together with control sys- Overvoltage category: II


tems powered with typical voltages: Pollution degree: 2
12, 24, 48, 110 V AC/DC, 230 V AC, Dimensions: monomodular (17,5 mm) 90x17,5x66 mm
● Maximum load current 2 x 8 A, Weight: 0,07 kg
● Relay state indicator. Reference standards: PN-EN 60669-1 PN-EN 60669-2-1 PN-EN 61000-4-2,3,4,5,6,11
PN-EN 61095:2004

The device is designed APPERANCE


for one-phase installation
and must be installed in
accordance with stan-
Input (supply) terminal (A1) Input (supply) terminal (A2)
dards valid in a particu-
CAUTION lar country. The device
should be connected
according to the details included in this
operating manual. Installation, connec-
tion and control should be carried out
by a qualified electrician staff, who act in
accordance with the service manual and
the device functions. Disassembling of Supply voltage indicator
the device is equal with a loss of guaran-
tee and can cause electric shock. Before
installation make sure the connection ca-
bles are not under voltage. The cruciform
head screwdriver 3,5 mm should be used
to instal the device. Improper transport,
storage, and use of the device influence
its wrong functioning. It is not advisable
to instal the device in the following ca-
ses: if any device part is missing or the
device is damaged or deformed. In case
of improper functioning of the device
Output relay
contact the producer.
terminals (22, 21, 24)
The symbol stands for selective Output relay
collection of electrical and
electronic devices. Placing used terminals (12, 11, 14)
devices with other waste is not
allowed

VER. 001_13.01.2010
MOUNTING, FUNCTIONING CONNECTING TIME COURSE

1. Disconnect the electric network by


means of appropriate cut-off, curren-
tlimiting circuit-breaker or separator.
t
2. Check if there is no any voltage
between power leads by means of t
an appropriate gauge.
3. Mount the device on TH 35 rail. t
4. Connect the system leads according
to the electrical diagram.
5. Connect power supply circuit.
After power supply has been connected INNER DIAGRAM
to A1, A2 terminals, the device, via the con-
trol circuit, makes the relay output contacts
11–14 and 21–24 closed. When power A1 A2
supply has been OFF, the relay will be OFF 14
and the output contacts 11–12 and 21–22 12
will be closed.
11
24
RELAY CAPACITY 22
21

DIMENSIONS EXAMPLE OF INSTALLATION

The motor control system


with rotation direction
changing.
The DC motor is supplied by
means of two PEM-02 relays.
The first one controls power
supply and the second controls
voltage polarity changing. Two
bistable control modules MOM-
02 control the PEM-02 relays.
Pressing first MOM-02 module
button causes e.g. clockwise
motor rotation and switch-ON
PRODUCT FAMILY interlock of the second MOM-
02 module. In order to change
The PEM-01 electromagnetic relay is a motor rotation direction it is
necessary to release the button
member of the PEM-xx family.
of the first module. The motor
will stop. Then it is necessary
to press the second module
Input voltage: button which will cause switch-
12V, 24V, 48V, 110V, 230V ing the motor in anticlockwise
direction. An additonal PEM-01
Device version: relay is needed to supply the
01 – input contacts 1 x 16 A relay cntrolling the motor power
02 – input contacts 2 x 8 A
supply correctly when the sec-
ond MOM-02 module is ON.
Device type

GUARANTEE CARD
There is 24 months guarantee on the product
1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other devices
needed for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer.
3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J.
4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation.
5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or
otherwise are not affected by this warranty.
Salesman stamp and signature, date of sale

VER. 001_13.01.2010