GC Varian 3800
GC Varian 3800
GC Varian 3800
Varian CP-3800 GC
Flexible platformsingle, dual, or three-channel configurations for maximum productivity. Easy upgradesquickly add additional capabilities as your requirements change. Simplified PC controlstreamline operation with intuitive, graphical interfaces for instrument control, data processing, and reporting. The Varian CP-3800 GC meets all your analytical requirements with practical solutions for simple and complex applications. In a standard configuration, the CP-3800 accommodates up to three injectors and three detectors, all operating simultaneously. In addition, the CP-3800 is easily configured to perform on-line analyses for monitoring critical gas and liquid process streams. The CP-3800s flexible platform lets you start with a basic configuration and add a wide variety of options in the field. Options include additional channels, gas and liquid sampling valves, and external sampling devices. Future upgrades guarantee that you can meet changing requirements at a moments notice. Unleash the full potential of the CP-3800 GC with the Galaxie Chromatography Data System. Galaxie dramatically improves daily workflow with intuitive, easy-to-use graphical interfaces for instrument control, data acquisition, processing, and standard and custom reporting. From a simple stand-alone GC system, to an automated Simulated Distillation package, the CP-3800 GC with Galaxie provides a powerful solution to all of your GC analytical needs. The CP-3800 GC from Varianunlimited possibilities!
AutoSamplers
CP-8400 handles up to 100 samples with liquid, ambient headspace, or optional SPME sampling modes CP-8410 with a fixed sample tray supports multiple vial sizes Combi PAL offers maximum flexibility for liquid, heated headspace, and SPME applications ArchonTM with Tekmar Velocity XPTTM for automated Purge and Trap sampling
Injectors
CP-1177 Split/Splitless Injector with optimized split vent design 1079 PTV (Programmable Temperature Vaporizing) injector for cold on-column, LVI (Large Volume Injection), and solid sample introduction with ChromatoProbe 1093 SPI (Septum-Equipped Programmable Injector) for high temperature capillary column applications 1041 On-Column/Packed Injector for 0.53 mm ID capillary and packed column applications 1061 Flash Injector for simplified direct injections Valve systems for gas and high pressure liquid samples Integrated SPT (Sample Preconcentration Trap) for concentrating gas samples
Column oven
Spacious oven accommodates three or more columns Varian Quick Connects provide easy column installation Rapid oven cool down increases sample throughput Cryogenic cooling extends application range
Detectors
Flame Ionization (FID) with a patented, ceramic flame tip for ultimate peak shape and sensitivity Thermal Conductivity (TCD) with automatic filament protection for lowest maintenance costs Electron Capture (ECD) for ultra-high sensitivity and selectivity of halogenated compounds Thermionic Specific (TSD) for selective detection of nitrogen/phosphorus compounds Pulsed Flame Photometric (PFPD) for selective detection of sulfur, phosphorus, nitrogen, and 25 additional elements
Navigate method parameters. Use section-specific soft keys to access and edit method parameters independent of PC workstation.
5
Actual size
Complete GC status in a single screen. View channelspecific information at the touch of a button.
Save time and reduce costs. The CP-8400 AutoSampler provides dual and duplicate injections with only a single tower.
CP-8410 CP-8400
Many samples or only a few. The CP-8400 AutoSampler and the CP-8410 AutoInjector deliver accurate, precise injections of small or large samples without sample carryover.
PAH_01A
PAH_02B
Double throughput without additional hardware costs! Dual sample injection mode for a 16-component Polynuclear Aromatic Hydrocarbon mixture injected into two injectors sequentially.
Eliminate solvents. Combi PALs advanced SPME mode with agitation and heating rapidly extracts semi-volatile samples without costly solvents.
7 Reduce carryover. Archons automated hot water rinse effectively flushes contaminants from prior samples for improved analytical results.
Exceptional Performance
Optimized injectors for every application
Varian has the injector to meet every application need. All Varian injectors for the CP-3800 are available with Electronic Flow Control (EFC) or manual pneumatics. Varians EFC optimizes GC injector performance by electronically controlling column pressure, flow, and split vent flow. Also, EFCs pressure pulse capability lets you increase injection volumes for greater sensitivity without injector overload. Also, EFC modules are designed for special inlet configurations such as purge and trap, headspace, and valved systems for maximum performance. In addition, EFC conserves costly carrier gas with convenient software control by reducing the split vent flow between injections. Simplify injector set-up, shorten method development time, and facilitate application troubleshooting with EFC from Varian.
Minimal solvent tailing. Dual split vent efficiently eliminates residual solvent for improved sensitivity.
Convenient injector interface. Intuitive screens provide quick and easy set-up for all injection parameters including pressure pulse.
Eliminate injection start errors. Varians AutoStart switch is automatically activated by the syringe to guarantee that every run starts immediately when the sample is injected.
Difficult Samples
Versatile inlet devices for the results you need
1079 PTV Injector
Injection volume: 240 L Detector: Varian TSD (NPD) Sample: 0.3 - 2.5 pg/L USEPA 507 Mix
1. 2. 3. 4. 5. 6. 7. 8. 9. Chlorpropham Prometon Simazine Atrazine Propazine Alachlor Ametryn Prometryn Terbutryn
Reduce sample prep time and costs. Large Volume Injections (LVI) improve laboratory productivity while maximizing sensitivity and minimizing solvent use.
Easy temperature programming. Intuitive interface makes the 1079 PTV easy to set up for cold on-column or large volume injections.
Ultimate sensitivitysetting the industry standard. Varians ECD provides ultra-high sensitivity for halogenated compounds, such as 7 fg/sec for Lindane.
Improved analyte response. The Varian FID, with its standard ceramic flame tip, delivers improved response for high molecular weight compounds.
Detector A
10
Instantly switch between injector/columns and detectors. The Quick-Switch Valve provides immediate access to multiple injectors/columns and detectors.
Detector B
Eliminate interferences. User programmable Gate Delay and Gate Width eliminate hydrocarbon background for greater selectivity and sensitivity.
Easy-to-operate, reliable sulfur detection. The PFPD provides a simpler, more cost-effective alternative to chemiluminescence for many trace sulfur analyses.
Sulfur Interference
11 Improve phosphorus detection 10-fold. Compared to the FPD, the pulsed operation of the PFPD selectively eliminates sulfur interferences during the analysis of phosphorus pesticides.
Custom GC Solutions
Simple solutions for complex separations
Varian has long been the leader in providing turn-key solutions for industrial, petrochemical, and environmental applications. The CP-3800s flexible platform easily supports a wide range of GC analyzers from a single Gas Sampling Valve with packed column for permanent gas analysis to an advanced four-valve, three-channel system with multiple columns for Refinery Gas Analysis. The Varian CP-3800 advantage: Eliminate application development time with standard and custom analyzers Column switching, series/bypass, backflush, and sample injection easily handled by single or multi-valve oven configurations Minimize baseline upsets with rapidly responding EFC optimized for valved configuration Improve sensitivity for trace gas analysis by concentrating samples with an integrated Sample Preconcentration Trap (SPT) Automatically switch between multiple sample streams with a stream-selector valve Varian manufactures, tests, installs, and supports these special configurations for the lifetime of your system. Our single vendor approach assures you the best possible return on your investment.
12 Always compact. Even with multi-valve, multi-column, and multi-detector configurations, the CP-3800 retains its compact footprint and ease-of-use.
Total control. Galaxie Workstation controls valve switching and provides easy valve identification.
Quick and easy access. Varians multi-valve oven with removable cover leaves actuators in place while providing complete access for valve troubleshooting and maintenance.
Enhanced sensitivity. Varians patented SPT concentrates trace analytes in air and gas samples for on-line processes and field samples brought to the laboratory.
Your choice of packing. With the Varian SPT, select from a variety of different packing materials for optimum selectivity and maximum sensitivity. Varian GC Application Note No. 65.
13
IEEE 488
St 800 St 800 St 800
RS232/RS422
Scalable stand-alone workstation to client/server solution. Galaxie offers a unique combination of scalable hardware and software to meet the widest range of requirements for instrument control and data management.
Superior Ease-of-Use
Increase productivity with simplified displays
Rapidly Build Rugged Methods
Instrument control and data handling methods are quickly generated with Galaxies intuitive graphical interface to deliver dependable results. For more reliable peak identification, Galaxie provides a choice of absolute retention times, relative retention times, or Kovats retention indices. To correctly select from several candidates in the same time window, an additional peak ID algorithm can be applied. Building peak integration methods for complex chromatograms is simplified with on-screen editing and display of more than 20 peak integration events. Peak identification and measurement are assured with Galaxie.
Easy method building. Interactive on-screen graphics and powerful algorithms deliver dependable peak identification and area measurements.
Simple Summaries
Galaxies Summary Report tool provides advanced data handling such as statistics and control charts for multiple chromatograms. By highlighting a series of chromatograms, tabular and graphical reports are easily generated. The Summary Report tool frequently allows users to bypass the complexity of working with databases. Galaxiefor simple, statistically sound management of data quality.
16
Easily track results and trends. Control charts monitor data quality by tracking sample trends or chromatographic variables.
SPEC Solid Phase Extraction Products. Monolithic disc technology delivers faster sampling processing and consistently high recoveries at low elution volumes.
Varian Gas Clean Filters. Extremely efficient filters remove moisture and oxygen to extend column life and improve system performance.
Varian FactorFour Capillary GC Columns. FactorFour columns deliver increased sensitivity and longer column life with a bleed specification up to four-fold lower than competitive products.
Shop Varian
Shop Varian Online. Thousands of products for GC, LC, MS, AA, ICP, UV/Vis, and sample preparation from Varian, ANSYS, and other leading manufacturers are available online at www.varianinc.com. 17
Varian, Inc. providing innovative tools for applications in: Pharmaceutical Genomics/Proteomics Bioscience Neuroscience Academic Research Drug Testing Petrochemical Environmental Food and Beverage Industrial R&D and Quality Control
Varian is committed to a process of continuous improvement which demands that we understand and then meet or exceed the needs and expectations of our customers both inside and outside the company in everything we do.
Varian Sales and Dealer Offices
WCI-0053.r1