Programmable Controller

IC690ACC901
GFK-0682E Mini Converter Kit
December 2003
The Mini Converter Kit consists of an RS-422 (SNP) The Converter Plug is required to convert the 9-pin
to RS-232 Mini Converter integrated into a 6 foot (2 serial port connector on the Mini Converter to the
meter) serial extension cable, and a 9-pin to 25-pin 25-pin serial port connector on an IC647 computer,
Converter Plug assembly. The 15-pin SNP port an IBM® PC-XT, or a PS/2® Personal Computer.
connector on the Mini Converter plugs directly into The IC640 industrial computer requires an additional
the serial port connector on the programmable adapter (not supplied – please contact your local
controller. The 9-pin RS-232 port connector on the PLC distributor) for use with the Mini Converter.
Mini Converter cable connects to an RS-232 Tables 1 and 2 list the Mini Converter pinouts. The
compatible device. direction of signal flow is with respect to the
Two LEDs on the Mini Converter indicate activity on Mini Converter.
the transmit and receive lines.

Figure 1. RS-422 (SNP) to RS-232 Mini Converter


Table 1. Mini Converter RS-422 Port Table 2. Mini Converter RS-232 Port
Pin Signal Name Direction Pin Signal Name Direction
1 SHLD – Shield n/a 2 SD - Send Data Output
5 +5 VDC – Power Input 3 RD - Receive Data Input
6 CTS(A') – Clear To Send Input 5 GND - Ground n/a
7 GND – Ground n/a 7 CTS - Clear To Send Input
8 RTS(B) – Request To Send Output 8 RTS - Request To Send Output
9 RT – Receive Termination Output
10 SD(A) – Send Data Output
Note: This datasheet applies to IC690ACC901
11 SD(B) – Send Data Output
versions C or later.
12 RD(A') – Receive Data Input
13 RD(B') – Receive Data Input
14 CTS(B') Clear To Send Input
15 RTS(A) – Request To Send Output
2 Mini Converter Kit
GFK-0682E

Pin Pin
System Configurations TXD 2 2 RXD
RXD 3 3 TXD
The Mini Converter can be used in a point-to-point CTS 7 7 RTS
configuration as described above, or in a multidrop RTS 8 8 CTS
configuration with the host device configured as the GND 5 5 GND
1 DCD
master and one or more programmable controllers 6 DSR
configured as slaves. 4 DTR

The multidrop configuration requires a straight- Mini Converter IBM PC-AT


through (1-to-1) cable from the Mini Converter’s RS-232 Port 9-Pin Connector
9-Pin Connector
RS-422 port to the first slave PLC’s SNP port. Other
slaves will require a daisy chain connection between Figure 2. Mini Converter to PC-AT
slaves. A maximum of eight devices can be
Pin Pin
connected in an RS-422 multidrop configuration.
TXD 2 3 RXD
All of the devices must have a common ground. If RXD 3 2 TXD
CTS 7 RTS
ground isolation is required, you can use the RTS 8
4
5 CTS
Isolated Repeater/Converter (IC655CCM590) in GND 5 7 GND
8 DCD
place of the Mini Converter. 6 DSR
20
When using the Mini Converter with a modem DTR

connection, it may be necessary to jumper RTS to Mini Converter IBM PC–XT, PS/2
RS-232 Port 25-Pin Connector
CTS (consult the user’s manual for your modem). 9-Pin Connector

Cable Diagrams (Point-To-Point) Figure 3. Mini Converter with Converter Plug to IC647
When connecting the Mini Converter to IBM PC and computer, PC-XT, PS/2
compatible computers with hardware handshaking, Pin Pin

the following cable connections should be used. TXD 2 3 RXD


RXD 3 2 TXD
CTS 7 4 RTS
RTS 8 5 CTS
GND 5 7 GND

Mini Converter IC640 Computer


RS-232 Port 9-Pin Connector
9-Pin Connector

Figure 4. Mini Converter to 9-Pin IC640 Computer or PC-XT


Computer (Additional Adapter Required)

Table 3. Mini Converter Specifications


Mechanical
RS-422 15-pin D shell male for direct mounting to serial port on the programmable controller
RS-232 9-pin D shell female for connection to RS-232 serial port of an IC647 industrial
computer or Personal Computer.
Electrical and General
Voltage Supply +5 VDC (supplied by PLC power supply)
Typical Current 100 mA
Operating Temperature 0° to 70°C (32° to 158°F)
Baud Rate 38.4K Baud maximum
Conformance EIA-422 (Balanced Line) or EIA-423 (Unbalanced Line)
Ground Isolation Not provided