Astor 16121921335769
Astor 16121921335769
Astor 16121921335769
With an indoor area of 100 acres equipped with the state-of-the-art technology and
outdoor area of 31 acres in the 2nd Organized Industrial Zone in Ankara, our new
factory with its completed facilities got started in 2016 and it has been going on the
production and sales of Medium-Voltage Switchgears and Compact Transformer
Substations at full pelt. Our primary goal is to improve our product range, which we
started with the production of SF6 Gas Insulated Disconnector and Load Breakers,
Metal-Enclosed Modular Cells and Monobloc Concrete Kiosks, with other product
groups by the help of R&D studies and to offer them to our customers.
Our main goal is to provide our customers with the high-quality products by following
up the latest technological developments, to improve our production capacity, and to
maximize customer satisfaction with the quality of our after-sales service.
ASTOR, which has all the required quality certifications, has the awareness of the
fact that its products are used everywhere with the electricity and continues its
production with this understanding. Our technical and administrative staff which is
composed of specialists, who are open to development and who cares quality, makes
a very great effort to achieve the target of R&D focused growth.
Products:
Air Insulated Modular Cell
24-36kV 630-1250A SF6 Gas Insulated Disconnector/Load Breaker
24-36kV 630-1250A SF6 Gas Insulated Load Breaker with Side Mechanism
Concrete Transformer Substations
Sheet Metal-Enclosed Transformer Substations
astoras.com.tr
astoras.com.tr
AS36 SERIES
AIR INSULATED METAL
ENCLOSED MODULAR
SWITCHGEARS
GENERAL
ASTOR brand Air Insulated Metal-Enclosed Modular Cells are a set of switching and control devices which have
been designed in accordance with TS EN 62271-200 (IEC 62271-200) standard for use in medium voltage
distribution systems up to 36 kV. All type tests required by the standard have been completed in accredited
laboratories in Turkey and abroad.
Various types of switchgear designs are available with the functional features required for MV distribution systems.
STRUCTURAL ADVANTAGES
OBSERVATION WINDOWS
The ON and OFF positions of the disconnector and earthing disconnector in the accessible section of the
switchgear can be seen through the observation windows on the covers in this section.
LOCKING MECHANISMS
OPERATING
MECHANISM
SECTION
BREAKER’S
OPERATING
MECHANISM
SECTION
CABLE
CONNECTION
SECTION
AS36 Series
AIR INSULATED METAL ENCLOSED MODULAR SWITCHGEARS
The components in the cable connection section depending on the switchgear's functional characteristics,
• Breaker
• MV fuses
• Earthing disconnectors
• Measurement transformers
The components in the low voltage section depending on the switchgear's functional characteristics,
• Protection relays
• Measurement tools
• Counters
• Auxiliary relays, LV fuses, terminal arrays and other low voltage control devices and switchgears
The section includes the following hardware in accordance with the single line diagram on the control and
display panel on the front side of the operating mechanisms;
• Mimic diagram
• Position indicators of the disconnector, switch disconnector, and earthing disconnectors
• Control lever sockets to be controlled for disconnector, and the earthing disconnectors
• "Spring adjusted" and "Spring Free" symbols
• Switch disconnector on/off buttons
• Voltage indicator and phase sequence control jack
• Operating instructions
• Sign plate
MV FUSE SELECTION
CONSIDERATIONS IN THE FUSE SELECTION
• The rated voltage of the fuse must be equal to or greater than the rated voltage of the system.
• The proper fuse must be selected in accordance with the characteristics of the fuse manufacturer. The
fuses to be used in the ASTOR brand Transformer Protection Cells with Switch Disconnector and Fuses
must have strike pins (medium type) in accordance with TS EN 60282-1 standard.
RATED VOLTAGE OF THE TRANSFORMER (36 kV)
FUSE SELECTION GUIDE
EFO İNTERTEKNİK
RATED VOLTAGE OF THE
Uk % RATED CURRENT OF THE FUSE (A)
TRANSFORMER (kVA)
25 4.5 2 2
50 4.5 4 4
160 4.5 10 10
200 4.5 10 10
250 4.5 10 16
400 4.5 16 16
800 6 25 40
1000 6 25 40
1250 6 40 50
1600 6 50 63
MEASUREMENT TOOLS
The measuring instruments such as the ammeter, voltmeter, electricity meter,
and the energy analyzer are selected in line with the customer desire and the
requirements of the project.
MV FUSES
High cut-off capacity MV fuses are used based on the transformer power in ASTOR brand switchgears
REMOTE CONTROL
The operations on the switchgear can be made using the remote control, which is provided together with
the ASTOR brand switchgears, up to 5 meters.
BUSBARS
The busbars, which are used in connecting the switchgears, are produced from high-conductivity-capacity
aluminum or copper which is isolated by a shrinking tube.
TECHNICAL SPECIFICATIONS
RATED VOLTAGE (kV) 36
AT ISOLATING DISTANCE 80
PROTECTION CLASSIFICATION IP 3X
INSTALLATION
PLACING THE SWITCHGEAR
The AS36 series switchgears should be
placed on a cable duct in the building, taking
into account the following measurements.
WARNING!
• The distance between the back of the
switchgear and the wall must be at
least 100 mm.
INSULATION
OPERATION
OPERATION
OPERATION
OPERATION
UNLOADED
UNLOADED
OPERATIO
OPERATIO
FUNCTIONS
CIRCUIT
CIRCUIT
N UNDER
N UNDER
SHORT
SHORT
LOAD
LOAD
It has been designed to ensure
√ √ √ √
safe insulation of the circuit. It is
DISCONNECTOR - - -
usually associated with a ground
knife.
Operating Mechanism
The breaker’s operating mechanism provides an "On-Off-On" process cycle without any need for a separate
process. It operates with the energy stored in a spring mechanism, which can be set by hand or motor, and it is
suitable for controlling with a remote control system. The switching-off spring is automatically adjusted by the
electric motor and the switching-on spring is automatically adjusted when the breaker is switched off. If the off
spring is not fully adjusted, the locking system prevents the breaker’s operation.
On the operating mechanism, there is a mechanical indicator showing the on and off position of the breaker, and
a mechanical counter, counting the number of switching on operations.
AS36 Series
AIR INSULATED METAL ENCLOSED MODULAR SWITCHGEARS
TYPE ACBS36
TYPE ADS36S
CATEGORY E0, M1
TYPE ALBS36S
CATEGORY E3, M1
CATEGORY E2 E2
AS36 LC
INPUT OUTPUT
SWITCHGEAR WITH
SWITCH DISCONNECTOR
Un (kV) 36 kV
Width (mm) 750
Length (mm) 1400
Height (mm) 2250
AS36 VTC
VOLTAGE TRANSFORMER
SWITCHGEAR
Un (kV) 36 kV
Width (mm) 750
Length (mm) 1400
Height (mm) 2250
AS36 CBT
TRANSFORMER PROTECTION
SWITCHGEAR WITH BREAKER
Un (kV) 36 kV
Width (mm) 1000
Length (mm) 1400
Height (mm) 2250
AS36 Series
AIR INSULATED METAL ENCLOSED MODULAR SWITCHGEARS
AS36 LF
TRANSFORMER
PROTECTION
SWITCHGEAR WITH
SWITCH DISCONNECTOR
AND FUSE
Un (kV) 36 kV
Width (mm) 750
Length (mm) 1400
Height (mm) 2250
AS36 CBC
INPUT OUTPUT
SWITCHGEAR WITH
BREAKER
Un (kV) 36 kV
Width (mm) 1000
Length (mm) 1400
Height (mm) 2250
AS36 CBC-C2
COUPLING
SWITCHGEAR WITH
BREAKER (WITH
DOUBLE BREAKER)
Un (kV) 36 kV
Width (mm) 1500
Length (mm) 1400
Height (mm) 2250
AS36 LC-G
GAS INSULATED INPUT
OUTPUT SWITCHGEAR
Un (kV) 36 kV
Width (mm) 750
Length (mm) 1400
Height (mm) 2250
AS36 KB
CABLE
CONNECTION
SWITCHGEAR
Un (kV) 36 kV
Width (mm) 750
Length (mm) 1400
Height (mm) 2250
AS36 LCV
CURRENT VOLTAGE
MEASUREMENT
SWITCHGEAR WITH
SWITCH DISCONNECTOR
Un (kV) 36 kV
Width (mm) 1000
Length (mm) 1400
Height (mm) 2250
AS36 Series
AIR INSULATED METAL ENCLOSED MODULAR SWITCHGEARS
AS36 LC-Y
BUSBAR
DISCONNECTION
SWITCHGEAR WITH
SWITCH
Un (kV) 36 kV
Width (mm) 1000
Length (mm) 1400
Height (mm) 2250
AS36 CBC-OTOP
INPUT OUTPUT
SWITCHGEAR WITH
VOLTAGE TRANSFORMER
Un (kV) 36 kV
Width (mm) 1500
Length (mm) 1400
Height (mm) 2250
astoras.com.tr
ABK SERIES
CONCRETE
TRANSFORMER AND
DISTRIBUTION
SUBSTATIONS
GENERAL
ASTOR brand MV/LV Concrete Transformer and Distribution Substations have been designed with a concrete
enclosure, monobloc structure, and compact type to be used in system voltages up to 36 kV in accordance with
the TS EN 62271-202 (IEC 62271-202) standard and TEDAŞ MYD technical specifications. All type tests
required by the standard have been completed in accredited laboratories in Turkey and abroad.
Concrete Transformer and Distribution Substations consist of three parts; HV switching units, MV distribution
transformer, LV distribution panel. Each section has its own independent access doors and ventilation louvers.
Various door and ventilation louver configurations can be made depending on the requirement.
USE AREAS
• Transformer Substations
• Distribution Substations
• Industrial Substations
• Wind Power Plants (WPP), Solar Power Plants (SPP)
• Compensation Facilities
• Water Pump Stations
• Generator Cabinets
ADVANTAGES
• Suitable for displacement due to its monobloc structure
• Quick and easy installation
• Compatible with the environment in terms of view and structure
• Various color options
• Resistant to all weather conditions
• Long service life
DESIGN AND STRUCTURAL PROPERTIES
GENERAL
• The concrete enclosure of the compact substation is produced with a monobloc structure including the
tank/foundation section and the side walls except for the roof. The roof is produced separately.
• The compact substation’s roof and its enclosure with its side walls and tank/foundation section are
completely waterproof.
• Tank/foundation section is suitable for the smallest bending radius of 36 kV 10x240 mm2 cable.
TYPES
ABK-A : Compact Transformer Substations with Air Insulated Cells (1000 kVA)
ABK-B : Compact Transformer Substations with Air Insulated Cells (1600 kVA)
ABK-H : Compact Distribution Substations with Air Insulated Cells
ABK-C : Compact Transformer Substations with Air Insulated Cells without LV Panel (1000 kVA)
ABK-D : Compact Transformer Substations with Air Insulated Cells without LV Panel (1600 kVA)
ABK-T : LV Panel and Distribution Transformer Substations
ABK-R : Compact Transformer Substations with GIS
ABK Series
CONCRETE DISTRIBUTION AND TRANSFORMER SUBSTATIONS
STRUCTURAL PROPERTIES
Enclosure
• The roof of the compact substation is resistant to the load of 2500 N/m2.
• The enclosure is resistant to wind pressure of at least 34 m/s.
• The ventilation louvers and the doors are resistant to the mechanical shock (IK10) which corresponds to 20
Joules from inside and outside.
• Enclosure Classification: 10
• It has been proved that concrete transformer substations are safe against earthquake conditions.
Partitions
The HV Cell Section and Transformer Section, and the Transformer Section and LV Panel Section are
separated by concrete partitions.
TECHNICAL SPECIFICATIONS
ENCLOSURE CLASSIFICATION 10
KIOSK
A-DETAIL
C20 CONCRETE
C 20
CONCRETE
SIDE VIEW
A-DETAIL
A-
DETAIL
FRONT VIEW
LV SECTION
MV SECTION TR SECTION
h=2400
h=2400 h=2400
TRANSFORMER
TYPE (MV+TR+LV) POWER a b c D E f g
ABK-A 4350 1000 kVA 1750 1700 600 2500 4350 4130 2280
ABK-A 5450 1000 kVA 2850 1700 600 2500 5450 5230 2280
ABK-A 6000 1000 kVA 3400 1700 600 2500 6000 5780 2280
ABK-A 6490 1000 kVA 3890 1700 600 2500 6490 6270 2280
ABK-A 7500 1000 kVA 4900 1700 600 2500 7500 7280 2280
h=2400
MV SECTION
TR SECTION
TRANSFORMER
TYPE (MV+TR+LV) POWER a b c D E f g
ABK-B 5450 1600 kVA 2300 2250 600 2500 4350 5230 2280
ABK-B 6000 1600 kVA 2850 2250 600 2500 6000 5780 2280
ABK-B 6490 1600 kVA 3340 2250 600 2500 6490 6270 2280
ABK-B 7500 1600 kVA 4350 2250 600 2500 7500 7280 2280
• Lowercase letters show inner measurements and the uppercase letters outer measurements.
• All measurements are shown in mm.
ABK Series
CONCRETE DISTRIBUTION AND TRANSFORMER SUBSTATIONS
MV SECTION
TRANSFORMER
TYPE (MV) POWER a b c D E f g
ABC-C COMPACT TRANSFORMER SUBSTATIONS WITH AIR INSULATED SWITCHGEARS WITHOUT LV PANEL
(1000 kVA)
TR SECTION
MV SECTION
TRANSFORMER
TYPE (MV+TR) POWER a b c D E f g
ABK-C 5450 1000 kVA 3490 1700 - 2500 5450 5230 2280
ABK-C 6000 1000 kVA 4040 1700 - 2500 6000 5780 2280
ABK-C 6490 1000 kVA 4530 1700 - 2500 6490 6270 2280
ABK-C 7500 1000 kVA 5540 1700 - 2500 7500 7280 2280
• Lowercase letters show inner measurements and the uppercase letters outer measurements.
• All measurements are shown in mm.
ABK-D COMPACT TRANSFORMER SUBSTATIONS WITH AIR INSULATED SWITCHGEARS WITHOUT LV PANEL
(1600 kVA)
MV SECTION TR SECTION
h=2400 h=2400
TRANSFORMER
TYPE (MV+TR) POWER a b c D E f g
ABK-D 5450 1600 kVA 2940 2250 - 2500 5450 5230 2280
ABK-D 6000 1600 kVA 3490 2250 - 2500 6000 5780 2280
ABK-D 6490 1600 kVA 3980 2250 - 2500 6490 6270 2280
ABK-D 7500 1600 kVA 4990 2250 - 2500 7500 7280 2280
LV SECTION
TR SECTION
h=2400
h=2400
TR SECTION
h=2400 h=2400
TRANSFORMER
TYPE (TR+LV) POWER a b c D E f g
ABK-T 2550 1000 kVA - 1740 550 2500 2550 2330 2280
ABK-T 3200 1000/1600 kVA - 2340 600 2500 3200 2980 2280
• Lowercase letters show inner measurements and the uppercase letters outer measurements.
• All measurements are shown in mm.
ABK Series
CONCRETE DISTRIBUTION AND TRANSFORMER SUBSTATIONS
REDRESÖR
TRANSFORMER
h=2400
POWER
h=2400
LV PANEL
1000 KVA
h=2400
TRANSFORMER
TRANSFORMER
SECTION
SECTION
AG PANO
MV+LV SECTION
AG PANO
MV+LV SECTION
TRANSFORMER
TYPE (GIS) POWER a b c D E f g
ABK-R 3800 (D)* 1000 kVA 1200 1700 600 2500 3800 3580 2280
ABK-R 4350 (I)** 1000 kVA 2390 1700 - 2500 4350 4130 2280
ABK-R 5450 (I)** 1000 kVA 3490 1700 - 2500 5450 5230 2280
ABK-R 4350 (D)* 1000 kVA 1200 1700 600 2500 4350 4130 2280
ABK-R 4800 (I)** 1000 kVA 2290 1700 - 2500 4800 4580 2280
*(D) Externally operating GIS kiosk; **(I) Internally operating GIS kiosk.
• Lowercase letters show inner measurements and the uppercase letters outer measurements.
• All measurements are shown in mm.
SOLAR POWER PLANTS
ANKARA ACAZA SOLAR POWER PLANT (1 MW)
NEVŞEHİR SOLARAN SOLAR POWER PLANT (1 MW)
ŞANLIURFA VİRANŞEHİR SOLAR POWER PLANT (12 MW)
ŞANLIURFA HİLVAN SOLAR POWER PLANT (8 MW)
ŞANLIURFA YENTEK SOLAR POWER PLANT (9 MW)
KIZILELMA SOLAR POWER PLANT (3 MW)
ŞANLIURFA BÖLÜCEK SOLAR POWER PLANT (14 MW)
ŞANLIURFABOZOVA SOLAR POWER PLANT (17 MW)
KONYA KULU SOLAR POWER PLANT (1 MW)
KONYA OVASAN SOLAR POWER PLANT (1 MW)
KÜTAHYA GÜNSER AND SİMEN SOLAR POWER PLANT (2 MW)
KONYA SAYLAM SOLAR POWER PLANT (1 MW)
ÇANKIRI KURŞUNLU SOLAR POWER PLANT (3 MW)
KONYA CİHANBEYLİ SOLAR POWER PLANT (3 MW)
ÇANKIRI MİKADO SOLAR POWER PLANT (1 MW)
YOZGAT COŞKUNLAR KAROSER SOLAR POWER PLANT (1 MW)
MALATYA SOLAR POWER PLANT ( 3 MW)
ANKARA ELMADAĞ SOLAR POWER PLANT (15 MW)
ŞANLIURFA SOLAR POWER PLANT (14 MW)
HİPOT&ARMİN UNINCORPORATED ASSOCIATION ISPARTA GÖNEN SOLAR POWER PLANT (1 MW)
HİPOT&ARMİN UNINCORPORATED ASSOCIATION SİVAS/TOKAT/ANTALYA/BURDUR SOLAR POWER PLANT (60 MW)
DISTRIBUTION COMPANIES