Converter 120ac 4-20ma Yokogawa
Converter 120ac 4-20ma Yokogawa
Converter 120ac 4-20ma Yokogawa
www.yokogawa.com/us/mi
JUXTA AC CURRENT TRANSDUCERS
1) GENERAL
The 2469 and 2489 AC Average Current transducers produce an analog DC signal output corresponding to
the average value of the AC input. The true RMS versions always require external power and produce an
analog DC output corresponding to the true RMS value of the input signal.
2) SPECIFICATIONS
Model # 2469 2489
Input Current 0-1 Amp AC or 0-5 Amp AC
Input over range capability 200% of rated input continuous
1000% of rated input for 5 seconds
Input Burden <0.2VA per element
Rated outputs 0-1mADC into 10 kΩ max. load; 10VDC output compliance
4-20 mADC into 750Ω max. load; 15VDC output compliance
Accuracy 10-100% of rated input 0-1mADC=±0.5% of full scale 0-1mADC=±0.2% of full scale
4-20mADC=±0.5% of span 4-20mADC=±0.2% of span
External calibration adjustment Zero: ±1% minimum(AHD only) Zero: ±5% minimum(AHD only)
Span: ± 2% minimum Span: ± 10% minimum
Response time <400 milliseconds(0-99% of output)
Output ripple 0.3% of span peak-to-peak max. 0.5% of span peak-to-peak max.
Isolation 2500 VAC input to output, power and case
2000 VAC aux. power to output and case (AHD and TRMS)
500 VAC output to case
Surge Withstand Capability IEEE472/ANSI C37.90.1 - 1989, JIS C1111(5KV, 1.2 x 50 microseconds)
Insulation resistance >10 megohm / 500VDC input/output/power/case
Operating temperature -20°C to +60°C
Operating humidity 0 - 90% relative humidity (non-condensing)
Temperature effect ± 250 PPM / °C of span ± 140 PPM / °C of span
External magnetic field < 0.2% at 400 AT/m
Input frequency range 50 - 500 Hz < 0.2% effect on accuracy
Influence of frequency < 0.2%, 45-65 Hz, fundamental through 9th harmonic (TRMS models only)
Weight TRMS = 900g, 0-1mA = 358g, 4-20mA = 897g, 3 in 1 = 1100g
Shock < 0.2% after 50G, 3 Axis and 6 repetitions
Vibration < 0.2% after 16.7 Hz, 4 mmp-p 1 hour, 3 Axis
UL Recognition File # E60579
3) STANDARD MODELS
0-5 Amp AC, 60 HZ input 2469 (0.5% Accuracy) 2489 (0.2% Accuracy)
NOTE: See order format on next page for additional ratings, frequency calibrations, power-up and output options.
Auxiliary power supply options <5.0 VA burden.
2
JUXTA AC CURRENT TRANSDUCERS
(1) (2) (3) (4) (5)
4) ORDER FORMAT 2469 / 89 - - -
(3) Input
Model# (1) Transducer function (2) Input frequency (4) Output (5) Aux. power
2469 21 Average current 37 0-1 Amp AC 0 60 Hz AFA 0-1 mADC 0 Input
2489 23 3 in 1 Avg. current 38 0-5 Amp AC 1 50 Hz (21 & 23 only) powered
31 True RMS current 2 50/60 Hz
4 400 Hz AFA 0-1 mADC
5 Other (TRMS only) 1 85-135 VAC
AHD 4-20 mADC 2 170-264 VAC
(21 & 31 only)
LINE
L1 L2 LINE
DC L1 L2 LINE
OUTPUT DC
+ -
OUTPUT - L1L2 L3
+ - + AUX +
DC OUTPUT
POWER -
1 2 3 4
+
DC OUTPUT
- 1 2 3 4
1 2 3 4 1 2 3 4 5 6
+
- DC OUTPUT
1 2 3 4
LOAD LOAD LOAD
(mm)
6) MOUNTING AND OUTLINE DIMENSIONS: inches (95.72)
➤
➤
3.769
(77.15) ➤ (111.6)
➤
➤ ➤ ➤ (78)
4.394 ➤
3.037 3.071
➤ (38.1)
➤
1.5
➤
➤
➤
➤
➤
➤
+
+
+
+
+
+
+
+
+
+
+
+
➤
(51.11)
(38.1)
1.969
2.012
1.500
(95.72)
(50)
(38.1)
3.769
3.071
(78)
1.5
➤
(120.65)
+
+
+
(111.6)
+
+
+
➤
4.750
(133)
5.236
4.394
➤
➤
➤
(88.9) +
+
+
+
+
+
+
➤
➤
3.500 ➤ (120.65)
➤
4.750
➤ (10.1)
➤
3.976
➤
➤
(133)
➤
➤
➤
5.236
➤
➤
(14.7)
.579
➤
➤
➤
(14.7)
(14.7)
.579
.579
➤
➤
➤
(104.03)
(89.33)
3.517
4.096
(105.1)
(105.1)
(119.8)
(119.8)
4.717
4.138
4.717
4.138
➤
➤
➤
246921 246923
SELF POWERED 246921 3 IN 1 CURRENT
248921 248923
248921 AUXILIARY POWERED
246931
248931 3
JUXTA AC V O LTA G E TRANSDUCERS
1) GENERAL
The 2469 and 2489 AC Average Voltage transducers produce an analog DC signal output corresponding to
the average value of the AC input. The true RMS versions always require external power and produce an
analog DC output corresponding to the true RMS value of the input signal.
2) SPECIFICATIONS
Model # 2469 2489
Input Voltage 0-150 VAC or 0-300 VAC
Input over range capability 120% of rated input continuous
Input Burden (Averaging models) 150 VAC: <1.8VA / element; 300 VAC: <3.6VA / element
Input Burden (true RMS models) 150 VAC: <0.8VA; 300 VAC: <1.6VA
Rated outputs 0-1mADC into 10 kΩmax. load; 10VDC output compliance
4-20 mADC into 750Ω max. load; 15VDC output compliance
Accuracy 10-100% of rated input 0-1mADC=±0.5% of full scale 0-1mADC=±0.2% of full scale
4-20mADC=±0.5% of span 4-20mADC=±0.2% of span
External calibration adjustment Zero: ±1% minimum(AHD only) Zero: ±5% minimum(AHD only)
Span: ±2% minimum Span: ±10% minimum
Response time <400 milliseconds(0-99% of output)
Output ripple 0.3% of span peak-to-peak max. 0.5% of span peak-to-peak max.
Isolation 2500 VAC input to output, power and case
2000 VAC aux. power to output and case(AHD + TRMS)
500 VAC output to case
Surge Withstand Capability IEEE472/ANSI C37.90.1 - 1989, JIS C1111(5KV 1.2 x 50 microseconds)
Insulation resistance >10 megohm / 500VDC input/output/power/case
Operating temperature -20°C to +60°C
Operating humidity 0 - 90% relative humidity (non-condensing)
Temperature drift ± 250 PPM / °C of span ± 140 PPM / °C of span
External magnetic field < 0.2% at 400 AT/m
Input frequency range 50 - 500 Hz < 0.2% effect on accuracy
Influence of frequency < 0.2%, 45-65 Hz, fundamental through 9th harmonic (TRMS models only)
Weight TRMS = 900g, 0-1mA = 358g, 4-20mA = 897g, 3 in 1 = 1100g
Shock < 0.2% after 50G, 3 Axis and 6 repetitions
Vibration < 0.2% after 16.7 Hz, 4 mmp-p 1 hour, 3Axis
UL Recognition File # E60579
3) STANDARD MODELS
0-150 VAC, 60 HZ input 2469 (0.5% Accuracy) 2489 (0.2% Accuracy)
NOTE: See order format on next page for additional ratings, frequency calibrations, power-up and output options.
Auxiliary power supply options <5.0 VA burden.
4
J U X TA A C V O LTA G E TRANSDUCERS
(1) (2) (3) (4) (5)
4) ORDER FORMAT 2469 / 89 - - -
(3) Input
Model# (1) Transducer function (2) Input frequency (4) Output (5) Aux. power*
2469 22 Average Voltage 33 0-150 VAC 0 60 Hz AFA 0-1 mADC 0 Input
2489 24 3 in 1 Avg. Voltage 36 0-300 VAC 1 50 Hz (22 & 24 only) powered
32 True RMS Voltage 2 50/60 Hz
4 400 Hz AFA 0-1 mADC
5 Other (TRMS only) 1 85-135 VAC
AHD 4-20 mADC 2 170-264 VAC
(22 & 32 only)
*Contact Factory
For Other Power
5) CONNECTION DIAGRAMS FOR PT INPUT Supply Options
LINE
DC L1 L2 LINE
DC L1 L2 LINE
OUTPUT
OUTPUT - L1L2 L3
-
+
- + + AUX (OPTIONAL)
POWER
+
DC OUTPUT
-
1 2 3 4
+
DC OUTPUT
-
1 2 3 4 1 2 3 4
1 2 3 4 5 6 +
- DC OUTPUT
1 2 3 4
LOAD
LOAD LOAD
(mm)
6) MOUNTING AND OUTLINE DIMENSIONS: inches
➤ (95.72)
3.769
➤
(77.15) ➤ (111.6)
➤
➤ ➤ ➤ (78)
4.394 ➤
3.037 3.071
➤ (38.1)
➤
1.5
➤
➤
➤
➤
➤
➤
+
+
+
+
+
+
+
+
+
+
+
+
➤
(51.11)
(38.1)
1.969
2.012
1.500
(95.72)
(50)
(38.1)
3.769
3.071
(78)
1.5
➤
(120.65)
+
+
+
(111.6)
+
+
+
➤
4.750
(133)
5.236
4.394
➤
➤
➤
(88.9) +
+
+
+
+
+
+
➤
➤
3.500 ➤ (120.65)
➤
4.750
➤ (10.1)
➤
3.976
➤
➤
(133)
➤
➤
➤
5.236
➤
➤
(14.7)
.579
➤
➤
➤
(14.7)
(14.7)
.579
.579
➤
➤
➤
(104.03)
(89.33)
3.517
4.096
(105.1)
(105.1)
(119.8)
(119.8)
4.717
4.138
4.717
4.138
➤
➤
➤