LI30 20BxxPR2
LI30 20BxxPR2
LI30 20BxxPR2
LI30-20BxxPR2 Series
30W, AC/DC DIN-Rail Power Supply FEATURES
Universal 85-264VAC or 120-370VDC input voltage
Accepts AC or DC input (dual-use of same terminal)
Operating ambient temperature range -40℃ to +70℃
High I/O isolation test voltage up to 4000VAC
Industrial product technology design
Over-voltage class III (Designed to meet EN61558 safety
standards)
Low standby power consumption, high efficiency
Low ripple & noise
Output short circuit, over-current, over-voltage protection
Withstand 300VAC surge input for 5s
UL/EN/IEC62368 safety approved
CB RoHS DIN rail TS35X7.5/ TS35X15 mountable
LI30-20BxxPR2 is Mornsun’s AC-DC series featuring a cost-effective, energy efficient solution for standard DIN-rail mounting. The products
offer a high level of stability and immunity to noise, compliant with international IEC62368 standards for EMC and safety sepecifitions meet
IEC/EN61000-4, CISPR32, EN55032, UL62368, IEC62368 and EN62368. These light weight AC-DC converters also have an extremely compact
design for space saving and are ideal for applications such as industrial control equipment machinery and all kinds of applications in a
harsh environment.
Selection Guide
Output Power Nominal Output Voltage Output Voltage Adjustable Efficiency at Capacitive Load
Certification Part No.
(W) and Current (Vo/Io) Range(V)* 230VAC (%) Typ. (µF) Max.
LI30-20B05PR2 15 5V/3A 4.9-5.5 82 12000
LI30-20B12PR2 24 12V/2A 10.8-13.8 88 6000
UL/CE/CB LI30-20B15PR2 30 15V/2A 13.5-18.0 89 5000
LI30-20B24PR2 36 24V/1.5A 21.6-29.0 89 1400
LI30-20B48PR2 36 48V/0.75A 43.2-55.2 90 600
Note: * The actual adjustment range may extend outside the values stated, care should be exercised to ensure that the output voltage and power
levels remain within the published maximum values.
Input Specifications
Item Operating Conditions Min. Typ. Max. Unit
AC input 85 -- 264 VAC
Input Voltage Range
DC input 120 -- 370 VDC
Input Frequency 47 -- 63 Hz
115VAC -- -- 0.9
Input Current
230VAC -- -- 0.5
A
115VAC -- 25 --
Inrush Current
230VAC -- 45 --
Leakage Current 264VAC 0.25mA RMS max.
Hot Plug Unavailable
Output Specifications
Item Operating Conditions Min. Typ. Max. Unit
Output Voltage Accuracy 0% - 100% load -- ±2 --
Line Regulation Rated load -- ±0.5 -- %
Load Regulation 230VAC -- ±1.5 --
5V Output -- -- 80
12V Output -- -- 120
20MHz bandwidth
Output Ripple & Noise* 15V Output -- -- 120 mV
(peak-to-peak value)
24V Output -- -- 150
48V Output -- -- 240
2020.05.30-A/3 Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LI30-20BxxPR2 Series
Temperature Coefficient -- ±0.02 -- %/°C
5V/12V/15V/24V Output -- -- 0.3
Stand-by Power Consumption 230VAC input W
48V Output -- -- 0.4
Short Circuit Protection Hiccup, continuous, self-recovery
Over-current Protection ≥120 % Io, self-recovery
5V Output ≤7.5V (Output voltage clamp or hiccup)
12V Output ≤16V (Output voltage clamp or hiccup)
Over-voltage Protection 15V Output ≤20V (Output voltage clamp or hiccup)
24V Output ≤36V (Output voltage clamp or hiccup)
48V Output ≤60V (Output voltage clamp or hiccup)
Minimum Load 0 -- -- %
Start-up Time -- -- 3 s
115VAC -- 12 --
Hold-up Time ms
230VAC -- 60 --
Note: * The “parallel cable” method is used for ripple and noise test, please refer to AC-DC Converter Application Notes for specific information.
General Specifications
Item Operating Conditions Min. Typ. Max. Unit
Electric Strength Test for 1min.,
Isolation Test Input - Output 4000 -- -- VAC
(leakage current<5mA)
Operating Temperature -40 -- +70
℃
Storage Temperature -40 -- +85
Storage Humidity -- -- 95 %RH
Operating Altitude -- -- 2000 m
Switching Frequency -- 65 -- kHz
5V/48V Output 3.0 -- --
-40℃ to -30℃ 12V/15V Output 7.0 -- --
%/℃
Power Derating 24V Output 5.0 -- --
+50℃ to +70℃ 2.5 -- --
85VAC - 100VAC 1.0 -- -- %/VAC
Safety Standard UL62368/EN62368/IEC62368
Safety Certification UL62368/EN62368/IEC62368
Safety Class CLASS I I
MTBF MIL-HDBK-217F@25°C > 300,000 h
Mechanical Specifications
Case Material Plastic, heat-resistant (UL94V-0)
Package Dimensions 92.66 x 35.00 x 58.00 mm
Weight 115g (Typ.)
Cooling method Free air convection
2020.05.30-A/3 Page 2 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LI30-20BxxPR2 Series
Note: ① With an AC input between 85-100VAC and a DC input between 120-140VDC, the output power must be derated as per temperature derating curves;
② This product is suitable for applications using natural air cooling; for applications in closed environment please consult factory or one of our FAE.
2020.05.30-A/3 Page 3 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LI30-20BxxPR2 Series
Note:
1. For additional information on Product Packaging please refer to www.mornsun-power.com. Packaging bag number: 58220077;
2. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<75% with nominal
input voltage and rated output load;
3. All index testing methods in this datasheet are based on our company corporate standards;
4. We can provide product customization service, please contact our technicians directly for specific information;
5. Specifications are subject to change without prior notice.
6. Products are related to laws and regulations: see "Features" and "EMC";
7. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by
qualified units.
2020.05.30-A/3 Page 4 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation