AC/DC 120W Enclosed Switching Power Supply

LIF120-10BxxR2 Series

FEATURES
 Universal 85 - 264VAC or 120 - 370 VDC Input voltage
 Accepts AC or DC input (dual-use of same terminal)
 Operating ambient temperature range: -40℃ to +70℃
 High efficiency up to 94%, high reliability
 DC OK function
 Active PFC
 150% peak load output for 3 seconds
 DC ON output status indicator LED
 Output short circuit, over-current, over-voltage,
over-temperature protection
Report RoHS  Operating altitude up to 5000m
UL61010-1 EN62368-1  OVCⅡ
UL61010-2-201  Indoor use
LIF120-10BxxR2 series is Mornsun AC-DC converter series featuring a cost-effective, energy efficient explosion-proof solution for standard
DIN-rail mounting. The products offer a high level of stability and immunity to noise, compliant with international IEC62368 standards for EMC
and safety specifications meet IEC/EN/UL62368, UL61010. These light weight AC-DC converters also have an extremely compact design for
space saving and are ideal for applications such as industrial control equipment, machinery, and all kinds of applications in a harsh
environments.

Selection Guide
Output Nominal Output Voltage Output Voltage Efficiency at Max. Capacitive
Certification Part No.
Power (W) and Current (Vo/Io) Adjustable Range (V) 230VAC (%) Typ. Load (µF)
LIF120-10B12R2 12V/10A 11.8-14.0 93.5 80,000
UL/EN LIF120-10B24R2 120 24V/5A 23.5-28.0 94 50,000
LIF120-10B48R2 48V/2.5A 47.0-53.0 94 30,000

Input Specifications
Item Operating Conditions Min. Typ. Max. Unit
Rated input (Certified voltage) 100 -- 240
VAC
Input Voltage Range AC input 85 -- 264
DC input 120 -- 370 VDC
Rated AC input 50 -- 60
Input Frequency Hz
AC input 47 -- 63
Rated Input -- -- 1.5
Input Current 115VAC -- -- 1.5
230VAC -- -- 0.75 A
115VAC -- 15 --
Inrush Current Cold start
230VAC -- 30 --
Leakage Current 240VAC <1mA
115VAC -- 0.98 --
Power Factor --
230VAC -- 0.94 --
Start-up Delay Time 230VAC -- 300 1000 ms
Hot Plug Unavailable

Output Specifications
Item Operating Conditions Min. Typ. Max. Unit
Output Voltage Accuracy Full load range -- ±1 --
Line Regulation Rated load -- ±0.5 -- %
Load Regulation 0% - 100% load -- ±1 --

2021.09.16-A/3 Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC 120W Enclosed Switching Power Supply
LIF120-10BxxR2 Series

20MHz bandwidth 12V/24V -- -- 100


Ripple & Noise* mV
(peak-peak value) 48V -- -- 200
Stand-by Power Consumption -- 2 -- W
Hold-up Time -- 20 -- ms
DC OK Signal Resistive load 30VDC/1A Max.
Constant current hiccup mode (constant
Short Circuit Protection Recovery time < 10s after the short circuit disappear. current mode works 1s and stop 10s)
continuous, self-recovery
Normal temperature,
105% - 200% Io, self-recovery
Over-current Protection 230VAC, rated load high temperature
Low temperature ≥105% full load after derating, self-recovery
≤18V (Hiccup, self-recovery after the
12V
abnormality is removed)
≤35V (Hiccup, self-recovery after the
Over-voltage Protection 24V
abnormality is removed)
≤60V (Hiccup, self-recovery after the
48V
abnormality is removed)
230VAC, Over-temperature protection start -- 90 --
Over-temperature Protection ℃
70% load Over-temperature protection release 60 -- --
Note: *The “Tip and barrel method” is used for ripple and noise test, output parallel 47uF electrolytic capacitor and 0.1uF ceramic capacitor, please refer to
Enclosed Switching Power Supply Application Notes for specific information.

General Specifications
Item Operating Conditions Min. Typ. Max. Unit
Input - 1500 -- --
Isolation Test Input - output Electric strength test for 1min., leakage current <15mA 3000 -- -- VAC
Output - 500 -- --
Input - 50 -- --
Insulation
Input - output At 500VDC 50 -- -- MΩ
Resistance
Output - 50 -- --
Operating Temperature -40 -- +70

Storage Temperature -40 -- +85
Operating Humidity -- -- 95
Non-condensing %RH
Storage Humidity 20 -- 95
Switching Frequency -- 100 -- KHz

Operating -40℃ to -25℃ 3.34 -- --


temperature +55℃ to +70℃ 85VAC-164VAC 2.0 -- -- %/℃
Power Derating
derating +60℃ to +70℃ 165VAC-264VAC 3.0 -- --
Input voltage derating 85VAC-100VAC 0.67 -- -- %/VAC
UL61010-1, UL61010-2-201 safety approved &
EN62368-1 (Report)
Safety Standards
Design refer to IEC/EN/UL62368-1, UL61010-1,
UL61010-2-201
Safety Class CLASS I
MTBF MIL-HDBK-217F@25℃ > 300,000 h

General Specifications
Case Material Metal (AL5052, SPCC, SGCC) and Plastic (PA66)
Dimensions 110.00 x 32.00 x 124.00 mm
Weight 490g±10% (Typ.)
Cooling Method Free air convection

2021.09.16-A/3 Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC 120W Enclosed Switching Power Supply
LIF120-10BxxR2 Series

EMC Specifications
CE CISPR32/EN55032 CLASS B
EMI RE CISPR32/EN55032 CLASS B
Harmonic current IEC/EN61000-3-2 CLASS A and CLASS D
ESD IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV perf. Criteria A
RS IEC/EN 61000-4-3 10V/m perf. Criteria A
EFT IEC/EN 61000-4-4 ±4KV perf. Criteria A
EMS perf. Criteria A
Surge IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV
CS IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A
Voltage dips, short interruptions
IEC/EN61000-4-11 0%, 70% perf. Criteria B
and voltage variations immunity

Product Characteristic Curve

Note: 1. With an AC input voltage between 85 -100VAC and a DC input between 120-140VDC the output power must be derated as per the temperature
derating curves;
2. This product is suitable for applications using natural air cooling; for applications in closed environment please consult Mornsun FAE.

Installation Diagram

Note: Keep the following installation clearances: 20mm on top, 20mm on the bottom, 5mm on the left and right sides are recommended when the device is
loaded permanently with more than 50% of the rated power. Increase this clearance to 15mm in case the adjacent device is a heat source (e.g. another
power supply).

2021.09.16-A/3 Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC 120W Enclosed Switching Power Supply
LIF120-10BxxR2 Series

Dimensions and Recommended Layout

2021.09.16-A/3 Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC 120W Enclosed Switching Power Supply
LIF120-10BxxR2 Series

WARNING Risk of electrical shock, fire, personal injury or death:


AVERTISSEMENT AVERTISSEMENT Risque de choc électrique, d’incendie, de blessures corporelles ou de décès :
1. Do not use the power supply without proper grounding (Protective Earth). Use the terminal on the input block for earth connection and
not one of the screws on the housing;
N’utilisez pas l’alimentation électrique sans mise à la terre appropriée (Terre protectrice). Utilisez le terminal sur le bloc d’entrée pour la
connexion terrestre et non pas une des vis sur le boîtier;
2. Turn power off before working on the device, protect against inadvertent re-powering;
Éteignez l’alimentation avant de travailler sur l’appareil, protégez-vous contre la réénergisation accidentelle;
3. Make sure that the wiring is correct by following all local and national codes;
Assurez-vous que le câblage est correct en suivant tous les codes locaux et nationaux;
4. Do not modify or repair the unit;
Ne modifiez pas ou ne réparez pas l’appareil;
5. Do not open the unit as high voltages are present inside;
Ne modifiez pas ou ne réparez pas l’appareil;
6. Use caution to prevent any foreign objects from entering the housing;
Faire preuve de prudence pour empêcher les objets étrangers d’entrer dans le logement;
7. Do not use in wet locations or in areas where moisture or condensation can be expected;
Faire preuve de prudence pour empêcher les objets étrangers d’entrer dans le logement;
8. Do not touch during power-on, and immediately after power-off, hot surfaces may cause burns;
Ne touchez pas pendant l’alimentation et, immédiatement après l’alimentation, les surfaces chaudes peuvent causer des brûlures.
9. For ambient temperature ≤60℃, use ≥90℃ - copper wire only; for ambient temperature >60℃ to 85℃, use ≥105℃ - copper wire only;
use only wires with a minimum dielectric strength of 300V (input) and 60V (output);
Température ambiante ≤60℃, utiliser ≥90℃ - seulement fils de cuivre; Température ambiante >60℃ et 85℃, utiliser ≥105℃ - seulement
fils de cuivre; Uniquement pour I’ulilisation de fils de cuivre d’une résisitance d’isolation minimale de 300V (d’entrée) et 60V (de sortie).

Note:
1. For additional information on Product Packaging please refer to www.mornsun-power.com.Packaging bag number: 58220189;
2. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<90% RH with
nominal input voltage and rated output load;
3. The room temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m;
4. All index testing methods in this datasheet are based on our company corporate standards;
5. In order to improve the efficiency at high input voltage, there will be audible noise generated, but it does not affect product
performance and reliability;
6. We can provide product customization service, please contact our technicians directly for specific information;
7. Products are related to laws and regulations: see "Features" and "EMC";
8. The out case needs to be connected to the earth ( ) of system when the terminal equipment in operating, see "Dimensions and
Recommended Layout" ;
9. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by
qualified units;
10. The output voltage can be adjusted by the output adjustable resistance ADJ, turn it up clockwise;
11. The units are Open Type Power Supplies, which need to be mounted in a fire, mechanically and electrically safe enclosure;
12. If the equipment is used in a manner not specified by manufacture, the protection provided by the equipment may be impaired.

Mornsun Guangzhou Science & Technology Co., Ltd.


Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Huangpu District, Guangzhou, P. R. China
Tel: 86-20-38601850 Fax: 86-20-38601272 E-mail: info@mornsun.cn www.mornsun-power.com

2021.09.16-A/3 Page 5 of 5