GNFGB
GNFGB
GNFGB
FA10-220SXXE2 Series
Typical Features
◆ Wide input voltage range: 85~265VAC/120-380VDC
◆Meet IEC60950/UL60950/EN60950
◆PCB mounting
Application Field
FA10-220SXXE2 Series----- a compact size, high efficient, meet CE standard power converter offered by Aipu.
It features universal input voltage, DC and AC dual-use, low ripple, low temperature rise, low power consumption, high efficiency, high
reliability, safer isolation, good EMC performance, meet EN55032,IEC/EN61000 standard. It widely used in power, industrial,
instrument and smart home applications. For harsh EMC environment, the application circuit in the datasheet is strongly
recommended.
Guangzhou Aipu Electron Technology Co., Ltd Add: Building 4, HEDY Park, No.63, Punan Road, Huangpu Dist, Guangzhou, CN.
Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/
Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A/0 Date:2018-01-10 Page 1 of 6
AC/DC Converter
FA10-220SXXE2 Series
Note 1: Due to space limitations, above is only a part of our product list, please contact our sales team for more items.
Note 2:.”*” is model under developing.
Note 3: The typical output efficiency is based on that product is full loaded and burned-in after half an hour.
Note 4: The fluctuation range of full load efficiency(%,TYP) is ±2%, full load output efficiency= total output power/module’s input power.
Input Specification
115VAC / / 0.22
Input Current
220VAC / / 0.12
A
115VAC / / 10
Surge Current
220VAC / / 20
External fuse
- 1A-2A/250VAC slow-fusing
recommended value
Output Specification
Vo1 - - ±0.5 %
Line Regulation Nominal Load
Vo2 - - ±1.5 %
Single Output 0 - - %
Guangzhou Aipu Electron Technology Co., Ltd Add: Building 4, HEDY Park, No.63, Punan Road, Huangpu Dist, Guangzhou, CN.
Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/
Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A/0 Date:2018-01-10 Page 2 of 6
AC/DC Converter
FA10-220SXXE2 Series
Overshoot range(%):≤±10 %
Output Dynamic 25%~50%~25%
Characteristics 50%~75%~50%
Recovery time(mS):≤5.0 mS
Over Current Protection Full input voltage range ≥150% Io Self-recovery Hiccup
- - 50 100 mV
Ripple & Noise
Note: Ripple& Noise is tested by Twisted Pair Method, details please see Ripple& Noise Test at back.
General Specifications
Input-Output
Isolation Voltage Test 1min, leakage current 4000 - VAC
≤5mA
Vibration - 10-55Hz,10G,30Min,alongX,Y,Z
MTBF - MIL-HDBK-217F@25℃>300,000H
Material Characteristics
Case Material Black frame-retardant heat-resistant plastic (UL94 V-0)
Guangzhou Aipu Electron Technology Co., Ltd Add: Building 4, HEDY Park, No.63, Punan Road, Huangpu Dist, Guangzhou, CN.
Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/
Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A/0 Date:2018-01-10 Page 3 of 6
AC/DC Converter
FA10-220SXXE2 Series
EMC Characteristics
Packing Dimension
Pin Definition
Pin-out 1 2 3 4 8
Single(S) FG AC(N) AC(L) +Vo -Vo
Note: If the definition of pin is not in accordance with the model selection manual, please refer to the label on actual item.
Guangzhou Aipu Electron Technology Co., Ltd Add: Building 4, HEDY Park, No.63, Punan Road, Huangpu Dist, Guangzhou, CN.
Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/
Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A/0 Date:2018-01-10 Page 4 of 6
AC/DC Converter
FA10-220SXXE2 Series
Test Method:
(1) 12# twisted pair to connect, Oscilloscope bandwidth set
as 20MHz, 100M bandwidth probe, terminated with 0.1uF
polypropylene capacitor and 10uF high frequency low
resistance electrolytic capacitor in parallel, oscilloscope set
as Sample pattern.
(2) Input terminal connect to power supply, output terminal
connect to electronic load through jig plate, Use 30cm±2 cm
sampling line, Power line selected from corresponding
diameter wire with insulation according to the flow of output
current.
Input输入电压降额曲线图
Voltage Derating Curve Temperature
温度降额曲线图 Derating Curve
100
100
90 90
Output Power Percentage(%)
Output Power Percentage(%)
85
输出功率百分比 (%)
输出功率百分比(% )
80
75
70 70
60 60
Input voltage
Ambient Temperature 25℃ 输入电压
50 环境温度25℃ 50 100~240V A C
140~340V D C
40 40
30 30
20 20
10 10
0 0
85 100 220 240 265 -40 -30 -25 10 20 30 40 50 60 65 70 75
输入电压(V A C ) (℃)
环境温度temperature(℃
Input Voltage(VAC) Ambient )
Note
1: Input Voltage should be derated base on Input Voltage Derating Curve when it is 85~100VAC/240~265VAC/120~140VDC/
340~380VDC.
2: Our product is suitable to use under natural air cooling environment, if use it under closed condition, please contact with us.
Guangzhou Aipu Electron Technology Co., Ltd Add: Building 4, HEDY Park, No.63, Punan Road, Huangpu Dist, Guangzhou, CN.
Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/
Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A/0 Date:2018-01-10 Page 5 of 6
AC/DC Converter
FA10-220SXXE2 Series
Photo 1
Note 1:
1) FUSE, recommend to use 2A~250Vac, slow fusing, block form;
5) C1 choose high frequency low impedance electrolytic capacitor, the capacitance lower than capacitive load, withstand voltage
1) C2 choose 0.1uF ceramic chip capacitor, withstand voltage value is above 1.5 times more than output voltage;
7) TVS1 is TVS tube: 5V output recommended: SMBJ7.0A,9V output recommended: SMBJ12.0A, 12V output recommended:
SMBJ20A, 15V output recommended: SMBJ20.0A, 24V output recommended: SMBJ30.0A, 48V output recommended: SMBJ64A.
Note :
1.The product should be used under the specification range, otherwise it will cause permanent damage to it.
2.Product’s input terminal should connect to fuse;
3.If the product is not worked under the load range(below the minimum load or beyond the load range), we cannot ensure that the
performance of product is in accordance with all the indexes in this manual;
4.Unless otherwise specified, data in this datasheet are tested under conditions of Ta=25℃, humidity<75% when inputting nominal
voltage and outputting rated load(pure resistance load);
5.All index testing methods in this datasheet are based on our Company’s corporate standards
6.The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model
products will exceed the above-mentioned requirements, please directly contact our technician for specific information;
7.We can provide customized product service;
8.The product specification may be changed at any time without prior notice.
Guangzhou Aipu Electron Technology Co., Ltd Add: Building 4, HEDY Park, No.63, Punan Road, Huangpu Dist, Guangzhou, CN.
Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/
Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A/0 Date:2018-01-10 Page 6 of 6