Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
307 views53 pages

2.0 Protection

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 53

2.

0 PROTECTION
EPOCH Protection System

Nepean Power is a proven leader in the supply and manufacture of quality engineered solutions, products and technologies.
Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The Epoch Protection System is the new generation in protection devices, designed to provide complete protection to the
AS/NZS 2081 :2011 standard and is certified Intrinsically safe under lEe 60079.11 ‘Ex ia’ for electrical equipment in mining
and industrial environments. Using advanced microprocessor controlled technology and state of the art hardware design,
the Epoch Protection System achieves high accuracy, long lasting reliability, and exceeds the requirements of Australian
Standards.
Flexibility in Design
EPOCH’s functions provide operational flexibility by:
EPOCH provides for a competitive market:
• Fault co-ordination to IEC
• Lower Life Cycle Costs
• Up to ‘16 outlets’ per system
• Fast Instantaneous Protection
• Single or Multiple displays
• High Noise Immunity
• Segregation of voltages. (ELV Modules)
• Date and Time Stamped
• EPOCH is supplied and comes with SKM Power
• Easily Replaces Existing Technologies
tools for windows (PTW) library blocks ready for
• Certified to the Latest Standards
integration into your site power system model
• System voltages ‘415V to 3.3kV’ are standard
components Spare Parts List
EPOCH’s compliant protection functions include: Part Description

• Earth leakage • Under voltage EP011 EPOCH Memory Module - EMM

• Earth continuity • Over Voltage EP012 EPOCH Control Module - ECM


EP013 EPOCH Power Interface Mod 1K EPIM1K
• Earth fault lockout • Under Current
EP014 EPOCH Power Interface Mod 3K3 EPIM3K3
• Loss of vacuum • Fan interlocking
EP015 EPOCH Display Module - PD1
• Frozen contact • Power Monitoring
EP016 EPOCH Remote Module - PR1
• Motor thermal • Type 2
modelling Co-ordination EP017 EPOCH Remote Module - PR1-ERM (dummy plug)
EP041 EPOCH ECM Pilot Barrier
• Short circuit • Phase Imbalance
EP051 EPOCH EDM IS Communication Barrier for PD1
• Overload • Phase Loss
EP081 EPOCH IS Power Supply for PD1

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-1
EPOCH Protection System
EPOCH MEMORY - EMM - EP011
Contains the database of protection function settings for all outlets and various loads. This
information is transmitted to all outlets and connected to the EMM via a high speed group
communication interface. Through this interface the run time data from each machine is
available to the EMM in real time. The depth of memory available to the EMM gives it the
advantage of being a gateway for external devices such as a PLC to access this data from
each outlet and the configuration settings each outlet is adhering to. The memory interface
takes on the important role of conducting synchronisation tasks between multiple outlets, for
example, controlling outlets which are interlocked by a fan.
EPOCH CONTROL - ECM - EP012
The Control Interface is the central unit of the Epoch Protection System and is the integral
component that brings together the full protection functionality of each outlet. It performs the
AS/NZS 2081:2011 Earth Continuity protection function on the outlet as well as receive and
process signals from the Power Interface. The pilot conductor is connected through an EP041
barrier into the hazardous zone. It drives the HMI Display (EDM) and also controls the Main
Circuit Breaker. External buttons for Start, Stop, and Reset are connected through the Control
Interface.
EPOCH INTERFACE - EPIM - EP013 + EP014
The Power Interface is the heart of the Epoch Protection System and its purpose is to collect
and process voltage and current signals in order to perform the protection functions for the
system.
It controls the main-contactor for each outlet and the design makes it quick and easy to install.
The Power Interface enclosure has been designed to provide protection from electrical noise
and as such ensures reliable operation in harsh target environments, such as high voltage
switching cabinets. There are two intrinsically safe devices certified to ‘Ex ia’ installed in a
Power Interface unit, the Real Time Clock (RTC) Flag Relay and the EFLO Barrier. When the
EPIM unit is powered, the RTC Flag Relay and EFLO Barrier are not suitable for installation in
a hazardous area and it is recommended that an ‘Ex d’ enclosure be used. When the EPIM is
not powered, the RTC Flag Relay and EFLO Barrier are suitable to be installed or present in a
hazardous area.
EPOCH DISPLAY - PD1 - EP015
The Display Interface is an ‘Ex ia’ panel mounted WVGA 480x272 pixel 24-bit full colour
LCD with a membrane keypad which integrates system functionality. This display, together
with the keypad has the advantage of reducing the wiring overhead for each outlet by
integrating test and runtime functionality. The interface is robust, easy to use and enables
the user to view system status, modify protection functions and debug trip issues using the
comprehensive event log database.The PD1 is powered by the EP081 IS power supply
and communicates with the ECM through the EP051 intrinsically safe communications
barrier.
EPOCH REMOTE MODULE - PR1 - EP016
The Remote Modules provide additional monitoring and protection for the connected
machinery. The PR1 relays information from the machinery back to the ECM using the pilot
wire. This information is then communicated via Extended Internet Protocol (EIP) to the EMM.
Monitoring of the machine includes equipment identification, earth continuity, remote start and
stop functionality as well as temperature protection. This ensures quick disconnection and
reconnection of a variety of plant as each machine has a unique identifier which is recognised
by the EPOCH protection system. The protection settings for the machine can be pre-stored on
the PR1 and this is automatically detected by the EPOCH system once the PR1 is connected
to an outlet. This allows for site wide management of the equipment and its protection settings
via the EMM and an Ethernet network connection. Equipment settings can be adjusted and
saved “in situ” by personnel authorised to access the locked reset facility.
PR1 - ERM - EP017
The PR1 can also be provided in a “dummy plug” arrangement.

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
Holistic Current
Shield Relay
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The HCS – Holistic Current shield relay has been designed and approved for use on earth fault limited systems providing earth leakage
protection (earth fault protection), as per AS/NZS 2081:2011. The relay is also suitable for other applications where equipment or system
earth leakage protection is required.

The relay provides protection from 0 – 6000Hz making it suitable for zero speed VVVF drive applications.

The HCS is a microprocessor-based AC/DC Sensitive Earth-Leakage Relay that offers complete coverage for all frequencies from 0-6,000
Hz. Two CT’s are required for the entire frequency range, or one CT can be used for only low-or high-frequency detection. An RTD/PTC
sensor input allows over-temperature protection. The HCS offers metering capabilities, password-protected alarm and trip settings and
optional network communications. It is used to add low-level ground-fault protection to variable-speed drives, and to DC currents.

Description
The HCS relay provides a definite time operating characteristic with adjustable trip sensitivity and time delay. The relay latches when tripped
and provides normally open and change-over relay contacts. The relay supports an external reset switch, and a 4-20mA interface allows
external monitoring. The user has the ability to individually adjust trip levels for both 20-90Hz frequencies and 190 to 6000 frequencies,
allowing visible monitoring and protection.

The HCS Earth Leakage Relay is housed in a robust industrial case and can be either ‘DIN Rail’ or ‘Panel’ mounted through a 69 x 39mm
cut out. When panel mounted, the front of the HCS relay is designed to provide IP56 ingress protection.

Features Ordering Information


• AS/NZS 2081:2011 (Section 6) compliant Part Number Description
• Wide operating bandwidth from DC 0Hz to 6000Hz X0463 HCS-A Harmonic Current Shield (Series A)
• Diagnostic digital display X0464 HCS Toroid 35mm Window - c/w Current Control
• 16 to 30 Vdc (+20,-25%), Nominal 24 Vdc X0465 HCS Toroid 80mm Window - c/w Current Control
• Wide current trip range (30 – 5000mA) X0466 HCS Toroid 140mm Window - c/w Current Control
• Fail safe operation X0472 HCS Din Rail mounting base
• Continual monitoring of the toroid
• Adjustable trip level and time delay settings

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-1
Holistic Current Shield Relay
Wiring Diagram

SUPPLY HCS
EARTH LEAKAGE

20 R1 21

22

19 R2 18

17
C1
16 R3 15

14

CT1 6
CT1

0-90Hz 7 RTD
9
8
10
CT2 3
11
CT2

20-6000Hz 4
5 PTC
9
RTD/PTC

10
REMOTE
RESET 11

1
SUPPLY 2
DC SUPPLY
+ -
ANALOG
OUTPUT

12

13
PGA-250
25
16-30VDC
26

24

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
Holistic Current Shield Relay
X0463 Drawing

X0464 Drawing

Mounting Hole Size

X0465 Drawing

Mounting Hole Size

X0466 Drawing

Mounting Hole Size

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
Machine Watch
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The MachineWatch (X0270 MW) is a complete Motor control safety system in one Inputs & Out
box. As a replacement for the FanWatch, the MachineWatch has improved reliability • 22 sensor inputs
and flexibility. • 5 Control relay outputs
NEPEAN Power’s MachineWatch is suitable for Coal Mines Auxiliary Fans and
other motor applications that require constant monitoring of vital functions.

The MachineWatch is capable of monitoring more than motor vibration, temperature,


airflow, gas content, voltage and current. Simply plug and play with any other
4-20mA compatible sensor and you can monitor whatever you like.

The MachineWatch can safely shutdown the motor in unsafe conditions such as
Overload, Undercurrent, Phase rotation/loss, and any other sensor you care to
connect.
Up to 100 trip events are stored in history within the unit and retained when power
is removed. The internal record keeps track of start/stop times as well as the service
run time.

Both live and history information is available through either ModbusTCP or


EthernetIP connections.

The X0287 PS is an improved design 24V power supply that allows the MW to
engage an Anti-Windmill Contactor up to 12 seconds after power is removed. The
PS also provides a secondary output to power 4-20mA sensors.

Ordering Information
Part Number Description
X0270 MachineWatch Protection Relay
X0270E MachineWatch Relay w/ ETH/IP
X0270M MachineWatch Relay w/ Modbus
X0287 MachineWatch/Fanwatch PSU Dual Put (24V & 32/22V) with AC Loss Detection
X0316 MachineWatch Power Supply
X0324 Personality Key to suit MachineWatch
X0342 MachineWatch Plug Set - 7 Plugs

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-1
Annex-1 Sample Diagram

80128-UM.X0270 Machine Watch User Manual Department: ET Page 22 of 24


Reviewed: August 2018 Rev: 1B
15-500A Overload Relay
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

Our solid state overload relay monitors the protected circuit and provides trips to ensure safe operation. Monitoring
checks for overload current, short circuit, under-current, and motor temperature (thermistor). It also detects faults with
the current transformers used.

Features Power
• Overload trip settings 15A-500A DC Supply
Dc input supply voltage: 16 to 34V DC
• Istantaneous Short Circuit (x1) to (x10) of the
Cold start Inrush @ 24V DC: 3A peak (4 sec)
Overload Setting Warm start Inrush @ 24V DC: 4A peak (3 sec)
• Selectable Undercurrent Detection Operating Current @ 24V DC: typically 100mA,
• Four Relay Outputs 200mA with optional ethernet
• Thermistor input Recommended power supply is 24V DC 50VA
• 2x CT inputs with open circuit and short circuit
detection AC Supply
• 3 second operation after power loss AC input supply voltage: 12 to 25V AC
• 4-20mALoad Current Monitoring Loop Recommended transformer is 18V AC 30VA
• Remote Ethernet monitoring/ control (optional) via
EthernetlPor ModbusTCP
Ordering Information
• Instantaneous over-current detection will latch
Part Number Description
within 40mS
X0306 Overload Relay
• Detects over-current situation as per Standard
X0306E Overload Relay with Ethernet IP
Inverse Curve
Communications
• Detects lowor high thermistor resistance
X0306M Overload Relay Modbus TCP
Communications
XCT10001 1000:1 Current Transformer
X0107 24Vdc 50VA DIN Rail Power

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-1
15-500A Overload Relay
Inputs Overview Diagrams
Current Transformers x 2
• Ratio 1000:1, 500A continuous rating, 15kA fault level
• Measurement tolerance within 5% of SC setting
• CA- and CB- are internally commoned

Thermistor
• 1500V Isolation
• 50 - 3000 ohms
• Trip tolerance 10%

Reset Buttons and Undercurrent Enable


• 1500V Isolation

Outputs
Relays
• Failsafe overload trip relay RA rated at 250Vac/6A,
24Vdc/ 5A
• Failsafe short circuit trip relay RB rated at 250Vac/ 6A,
24Vdc/ 5A
• Two non-failsafe indication relays with user program-
mable functions (RC and RD), rated at 30Vdc/ 2A,
250Vac/ 0.25A

Current Monitoring Loop


• 4-20mA (equivalent to 0-500A) load current monitoring
loop
• Accuracy 5% of SC setting

Trips and Indicators Indicator Relays RC & DC


Relay RA Each relay has a programmable function from ten
• Overload trip as per standard inverse curve Adjustable combinations of instantaneous trip, overload trip,
from 15A to 500A in 5A increments thermistor trip, CT fail and undercurrent.
• Thermistor trips below 50 ohms and above 3000 ohms Undercurrent indication is available on selected
• Current transformer self test is performed at power on relays following a continuous 5 second period of
or after reset. Checks inductance >300mH +/-20% current less than the under-current trip threshold.
The detection must be enabled by an open circuit
Relay RB to the EN pin. Thresholds are selectable from
Instantaneous trip within 50ms ot RMS current increasing 20%, 30% or 40% of the overload trip setting.
above instantaneous trip level. the instantaneous trip level
is adjustable from 1 to 10 times the overload level in steps
of 1.

Physical
Din rail mounted, 4mm cage screwed terminals, IP20
Dimensions: 90 x 75 x 106 mm

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
Electronic Over Current Relay

AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The EOCR DS1 range are designed for suitability of general motor overload protection. With it’s compact design and
separate adjustable starting and operating trip delay timers it is ready for the task at hand. This product includes DIN rail
mounting and Fail-safe operation for efficient and effective use. This product also offers a microprocessor control unit as
well as straight through cabling.

For more information please contact:


Innovation . Dedication . Specialisation P: +61 2 4088 2790
www.nepeanpower.com
E: power@nepean.com
2-1
Electronic Overcurrent Relay
Characteristics Curve

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
HLO- Holistic Earth
Fault Lockout
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The Nepean HLO Holistic Earth Fault Lock out relay has been designed to detect Earth Faults on conductors in an
outgoing circuit of an electrical system and to prevent the closure of the electrical supply to the de-energised circuit

Operational
When incoming mains power is switched onto the system the HLO scans the outgoing cable and will lockout if an earth
fault is present of 10K ohms or less. Detection of a fault will prevent the circuit switching device from being closed.
The unit is failsafe in operation and will drop out on detection of a fault and remain open until the fault is cleared.
The power supply to this unit is designed to maintain the function in its healthy mode for 2 seconds under no volt conditions
thus preventing premature drop out under system fault conditions.
Features Specifications
• Fail safe operation Supply 24-48V AC/DC 50/60Hz 5VA
• Relay scans the outgoing cable and will
lockout if an earth fault is present Meterial Housing high impact poly carbonate
• Outgoing circuit is monitored until the Voltage Tolerances -30% ~ 20%
contactor or circuit switching device is -100% for 2+ seconds
closed Fail Safe ˃10k Ohms
• Drop out on fault detection. Remaining
Relay Contacts 2 pole changeover 5A-250v
open until fault is cleared
• LED indication of power on Base Mounting DIN rail
• LED indication of system healthy status
• Usage in conjunction with an 1100v
to 24v intrinsically safe barrier HSB to
isolate high voltage from the detector
circuit
Ordering Information
Part Number Description
X0510 HLO Lock Out Relay 24V DC
X0512 1000V Safety Barrier

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-1
Holistic Earth Fault Lockout
Performance Dimensions

95mm 55mm

110mm
110mm
Connection Diagram

Unit can be mounted on Din Rail

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
Holistic Neutral Earth
Protection System
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

Features:
The Holistic Neutral Earth Protection system (HNER) has been designed to ensure safety and compliance. This relay system continuously monitors
the resistive value of the earth fault limiting Resistor (NER), and the neutral current value. As the relay is fully programmable via the door mounted
HMI each relay can monitor a Neutral resistor value of up to 650 ohms making this single relay usable at all system voltages up to 4000V AC Phase
to Phase. Higher voltages are possible using an alternate barrier.

The system continuous monitors the Neutral resistor value and the Earth leakage current to ensure maximum reliability of equipment and safety of
your personnel.

Each relay has dual power supply functionality allowing them to be supplied from either 110-240V AC/DC or 24-48V AC/DC at 50/60Hz. Thus,
reducing site spares.

The NER integrity is confirmed via two (2) independent trip contacts (9-14) these change over contacts will activate if there is a change in the resistive
value of the NER or an increase in the Neutral voltage. The earth leakage current in the neutral is continuously monitored via an independent toroid,
in the event excessive leakage current is detected 2 additional change over relays (41-46) will operate.

Remote diagnostics and monitoring are provided via the Modbus and analog connections. The Modbus offers real time protection settings, measured
values and relay status while the 4-20mA or 2-10V analog allows measured earth leakage levels. The serial communications has two selectable
protocols available - Modbus ASCII and Modbus RTU.

The NER barrier provides isolation from potentially high Neutral voltages that are experienced during an Earth Fault. The Barrier should be mounted
adjacent to the NER being monitored, leaving the HNER relay with a maximum of control voltage.

The system can be configured to be either failsafe/non-failsafe as well as either latching/non-latching depending on the application. (Changes may
affect compliance with AS2081) Advantages:
• Proven Design
The following functions are available:
•NER Integrity - adjustable resistance range • Locally Stocked
•Earth Leakage - with harmonic selection (5-100Hz)
•Overvoltage - adjustable up to 4000V • AS2081/AS4871 Compliant
• Mutli NER Resistance - Less spares
Adjustable trip times
•50 to 500ms for Earth Leakage and Overvoltage, • Multi Aux Voltage - Less spares
•2 to 10 Sec for NER Integrity
• Price Competitive
The HNER relay, Display and Barrier are housed in high impact PVC housings. • Suitable for VVVF Applications
The relay and barrier are DIN rail mounted while the display enclosure is panel mounted for easy access and operation.
For more information please contact:
Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-1
Holistic Neutral Earth Protection System
Connection Diagram

Specifications Compliance
Power Input 110-240VAC or DC AS/NZS 2081:2011
24-48VAC or DC • Electrical Equiptment for Mines
Voltage Tolerance -25% to +20% • Electrical Protection Devices
NER Resistance Values NER 10 to 600 ohms
-50% to +100%
NER Trip Value Adjustment
(as per AS/NZS 2081:2011)
Dimensions (H x W x D):
HNER 96 x 178 x 110
Display 97 x 97 x 55
Ordering Information
Barrier 97 x 37 x 110
Part Number Description
Trip Tolerance -10% to +10%
X0500 Holistic Neutral Earth Relay
Trip Delay Timer 50 to 500ms EL & OV
2 to 10 seconds for NER integrity
X0501 HNER Display Unit
Excess Voltage Trip 5 - 50% Phase Voltage X0502 HNER Toroid
Climate 0 - 60° C X0503 HNER Barrier

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
HFC – Holistic
Frozen Contactor
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The HFC - Holistic Frozen Contactor has been designed to detect a voltage leak across the contacts of any type of electrical
switching device for the protection of personnel from electrical shock or the risk of electrical sparking.

Operational
The HFC is designed to detect a leakage of voltage across a
switching device of 24 volts or more when the switching device is supposedly in the open or tripped position.
A barrier is used in conjunction with this relay. The barrier is a three phase unit used to isolate high voltages from the detection
equipment. As the barrier is a three phase unit leakage on any or all of the phases being monitored will be detected and cause
a trip. The detection circuit is non fail safe and energises on detection of leakage. The unit is internally powered from the power
supply card.

Features Specifications
• Internal Power Supply Supply 24-48V AC/DC 50/60Hz 5VA (opera-
• Timer delay function adjustable to 4 - 20
tional for 25sec on removal of module
and 10 - 60 (depending on model) seconds
for situations where the system is directly supply)
switching motors Meterial Housing high impact poly carbonate
• Detection circuit is non-fail safe and energises Voltage Tolerances -30% ~ 20%
on detection of leakage
-100% for 2+ seconds
• Factory set to detect a leakage of 24 volts or
more Leakage Factory set to detect 24V or more
• LED indication of power on Relay Rating Coil to contract 2.5kV
• LED warning when the Frozen Contactor/Loss Electrical life greater than 2 x 105 op-
of Vacuum Fault rises eration at maximum load
• Usage in conjunction with a Holistic Safety
Barrier suitable for systems up to 1100v. Relay Contacts 2 pole changeover 5A-250v
Base Mounting DIN rail
Ordering Information
Part Number Description
X0511 Holistic Frozen Contactor Relay
X0512 Safety Barrier

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-1
Holistic Frozen Contactor
Performance Dimensions

95mm 55mm

110mm
110mm
Connection Diagram

Unit can be mounted on Din Rail

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
HEL - Holistic Earth
Leakage Relays
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The NEPEAN HEL-P & HEL-D earth leakage relays have been designed and approved for use on earth and
non- earth fault limited systems, permitting the use in coal mining applications and providing earth leakage/
fault protection as per AS/NZS 2081:2011. Additionally suitable for other applications where equipment or
system earth leakage protection is required.

The HEL relays utilise a microprocessor design, providing a definite time operating characteristic with ad-
justable trip sensitivity and time delay. The relay latches when tripped and provides normally open and
change-over relay contacts. The relay supports an external reset switch.

The HEL Relays are housed in either a Panel mount (-P) or Din Rail (-D) version.
An attachment to prevent unauthorised adjustment of the trip settings is available separately.

An outstanding characteristic of the relays is the permanent control of the Toroidal monitoring circuit.
Its interruption brings along the immediate trip of the protection. The instrument, fitted with filters at the input
circuits, is practically immune to external disturbances, so as the pulse currents with dc components, com-
plying with the requirements of VDE 0664 and project IEC 23

Features
• AS/NZS 2081:2011 (Section 6) compliant Part No. Description
• Fail safe operation
• Aux Voltage range of 24 - 240V AC/DC X0520* HEL-P - Earth Leakage Relay Panel Mount
• Continual monitoring of the toroid X0525* LEL-D - Earth Leakage Relay Din Mount
• Adjustable trip level 20mA – 25Amp X0521* 35mm Earth Leakage CT
• Adjustable trip delay 25mS – 5 Seconds X0522* 80mm Earth Leakage CT
• AC or DC supply operation. X0523* 120mm Earth Leakage CT
• Functions normally for two (2) seconds during X0524* 155mm Earth Leakage CT
extreme power dip or power loss

For more information please contact:


Innovation . Dedication . Specialisation P: +61 2 4088 2790
www.nepeanpower.com
E: power@nepean.com
2-1
Holistic Earth Leakage Relays
Specifications
Models and Values HEL-D HEL-P
Auxiliary Voltage supply 24 - 240V AC/DC
Frequency 50 / 60 Hz
Maximum consumption 3 VA
Current tripping adjustment range 0.025÷0.25A K=0.1 - 0.25÷2.5A K=1 - 2.5÷25A K=10 25÷250A*
Tripping time adjustment range t 0.02÷0.5 sec. K=1 - 0.2÷5 sec. K=10
Output: 1 changeover contact 5A 250V
Working Temperature -10 + 60°C
Storing Temperature -20 + 80°C
Relative humidity ˂90%
Insulation Test 2.5 Kv 60 seg.
CEI 41-1/IEC 255/VDE 0664/IEC 755/CEI 64.8/ EN 61008-1 (1999-11)/
Standards EN 62020 (1999-09) / EN 61543 (1999-09) /EN61326-1(1998-04) / EN
61326/A1 (1999-05)-IEC 60947-2 ANNEX M /ASNZS 2081
Wiring method Screw terminals for cross section wires 2.5 mm²
Mounting according DIN 50022 Snap on DIN rail 35mm
Protection degree according DIN 40050 IP 20

1 Current tripping setting potentiometer

2 Tripping time setting potentiometer


Micro switches for programming:
a. In position 1 automatic reset, in position
0 manual reset
b. Selection of the multiplying constant
Tripping time, in position 1 K= 10; in
3 postion 0 K= 1
c, d. Selection of the multiplying constant of
tripping current:
With c, d in position 0 K=0.1
With c in position 1, d in position 0 K= 1
With c, d in position 1 K= 10
4 Push button for test

5 Push button for manual reset


Signalling green LED for Aux, supply pres-
6
ence
7 Signalling red LED for relay tripped

8 Health Status

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com 2-1
www.nepeanpower.com
Holistic Earth Leakage Relays
Performance Connection Diagram

Dimensions HEL-P
91mm

91mm

Dimensions HEL-D
110 55
96

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
Holistic Earth Leakage Relays
Dimensions
X0521
85
2-M3.5

35

107

5
83

64

99 30

30
X0522 4-M3.5

54

80
145.5

43
73

5 5
144.4

93 54

X0523 30
4-M3.5

95

120

43
193

5 5
99

109

105.5 54

30.5
X0524
4-M3.5

129
46.5

155
233
117

5 233 5

162
233 54.5

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com 2-1
www.nepeanpower.com
HEC - Holistic Earth
Continuity Relay
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The HEC is an electrical protection relay designed for operation in underground coal mining applications. It
provides earth continuity protection functions that ensure the electrical distribution system in the mine oper-
ates safely. It continually monitors the earth continuity of a mining trailing or reeling cable.
Features Specifications
• AS/NZS 2081: 2011 Compliant Ambient Tempera- -20°C ~ 65°C
• SIL2 Capable ture
• 24V - 48V AC/DC Voltage 24-48V AC/DC
• 5 x diagnostic LEDs Current 230mA - 120mA
1. Power On Certificate No IECEx TSA XX.XXXX
2. Healthy I/O Parameters Um = 132Vrms
3. SC Trip Im = 5.25A for 1s
4. OC Trip Uo = 28V
5. Start Timed out Io = 184mA
• Trip time settings – 50ms, 100ms, Po = 1.28W
200ms, 300ms, 400ms, 500ms Co = 2.0uF
• Trip resistance settings - 10Ω, Lo = 10.0mH
15Ω, 20Ω, 25Ω, 35Ω, 45Ω Relay Contacts 2 x NO / 1 x NC / 2 x COM
• Selectable remote start 1A @ 110Va.c. - 1A @ 30Vd.c
Limits
• Selectable trip latching (Resistive)
• Diode termination Weight 503gms
IP Rating IP20

Ordering Information
Part Number Description
Earth Continuity Protection
X0505
24-48V AC/DC

For more information please contact:


Innovation . Dedication . Specialisation P: +61 2 4088 2790
www.nepeanpower.com
E: power@nepean.com
2-1
Holistic Earth Continuity Relay
Performance Dimensions

95mm 55mm

Connection Diagram

110mm
110mm

Unit can be mounted on Din Rail

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-1
www.nepeanpower.com
Belt Slip & Speed Monitor
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

MEASURES 3 X PROXIMITY SWITCHES


The NEPEAN Power Belt Slip and Speed Monitor is designed to fulfill the needs of speed and slip measurement for
conveyor systems. The Belt Slip Relay is compliant with AS/NZS 4024.3611:2015 which corresponds to “Safety of
Machinery. Conveyors-Belt conveyors for bulk material handling. Clause 2.8.2.2”.
Slip Monitoring
• Measures slip between a belt speed (input S1) and two
other driven rollers (inputs S2 & S3). Or the slip of one
roller from its normal run speed
• Provides the maximum slip measurement (0-50%) on a
4-20mA output
• Provides a proximity sensor fault indication by closing the
PROX fault relay output
• A fail-safe relay can provide a trip signal when slippage
limits are exceeded

Speed Monitoring
• Measures and displays speed of up to three rollers (via
proximity inputs)
• Provides the speed measurement (0-150% of normal run
speed) on 4-20mA outputs (for remote monitoring)
• Provides a system healthy indication by closing the
80%-Relay after both start signal and 80% speed is
detected
• Both under-speed and over-speed conditions can cause
the fail-safe signal to trip
Ordering Information
Part Number Description
X0289FS Belt Speed / FailsafeW/ Int Input Resistors For 2 Wire Pros Sens.

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-2
Belt Slip and Speed Monitor

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-2
www.nepeanpower.com
Phase Loss & Rotation
Relay
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and technologies.
Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The unit has been designed for use with power systems and rotating machines
where the possibility of incorrect phase rotation exists. Phase rotation and phase
loss are constantly monitored and reported by LEDs on the front panel and relay
contact outputs.

The unit is powered from 24VDC (X0431), and will directly sense voltages of
415V to 1100VAC phase to phase. There are separate relays with change over
contacts for each phase direction, one of which will change state on the correct
phase sequence being detected. Both phase rotation and loss are detected in
less than a second.

The unit is housed in a convenient din rail mounted enclosure. Control power and
relay terminations are via a plug in connector with screw terminals and the phase
sensing is 600mm flying leads.
600mm 1000V flying leads
Dimensions: 45mm x 75mm x 105mm (W x H x D)

Ordering Information
Part Description
X0269 Phase Loss and Rotation Relay

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-3
PLAR and Power
Supply
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

X0269: Phase Loss and Rotation Relay (PLAR) X0431 85-264VAC to 24V Power Supply
The unit has been designed for use with power systems • Universal AC input/full range
and rotating machines where the possibility of incorrect • Protections: Short circuit/overload/over voltage
phase rotation exists. Phase rotation and phase loss are • Cooling by free air convection
constantly monitored and reported by LEDs on the front • Can be installed on DIN rail
panel and relay contact outputs. The unit is powered from • TS-35/7.5 or 15 NEC class 2/LPS compliant
24VDC (X0431), and will directly sense voltages of 415V to • LED indicator for power on
1100VAC phase to phase. There are separate relays with • No load power consumption <0.75W
change over contacts for each phase direction, one of which • 100% full load burn-in test
will change state on the correct phase sequence being • 3 years warranty
detected. Both phase rotation and loss are detected in less • Dimensions: 22.5mm x 90mm x 1000mm
than a second. The unit is housed in a convenient din rail (W x H x D)
mounted enclosure. Control power and relay terminations
are via a plug in connector with screw terminals and the Ordering Information
phase sensing is 600mm flying leads. Part Description
Dimensions: X0269 Phase Loss and Rotation Relay
45mm x 75mm x 105mm (W x H x D)
X0431 85-264VAC TO 24V Power Supply

600mm 1000V flying leads

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-3
690V Square Pipe Fuses
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

NEPEAN Power’s range of 690V Square Pipe Fuses offer superior protection against overload and short-circuit in electric
lines (type gG) and protection of semiconductor parts and equipments against short-circuit (type aR). These fuses have
a rated voltage up to 690V, a rated breaking capacity up to 120kA and a working frequency of 50Hz AC. These fuses are
suitable for a variety of different industry requirements with a range to suit rated currents between 63A and 160A. Our
fuses are manucatured in compliance with GB13539 and IEC269.

Features
• Variable cross-section fuse element made from pure copper or silver sealed in cartridge made from high-duty ceramic
material
• Fuse tube filled with chemically treated high-purity quartz sand as arc extinguishing medium
• Dot-welding of fuse element ends to the terminals ensures reliable electric connection and forms insert knife type
contacts
• Indicator or striker may be attached to the fuse link to show cutout of fuse or to give various signals and to cut the
circuit automatically

RNH Series - Size 00, Type gG (Normal)


Rated Rated Dimensions (mm)
Part Number Weight (g)
Current Voltage A B C D H
RNH-63 63A 690V 78 50.5 15 30 60 201
RNH-80 80A 690V 78 50.5 15 30 60 201
RNH-100 100A 690V 78 50.5 15 30 60 201
RNH-125 125A 690V 78 50.5 15 30 60 201
RNH-160 160A 690V 78 50.5 15 30 60 201

RS31 Series - Size 00, Type aR (Fast)


Rated Rated Dimensions (mm)
Part Number Weight (g)
Current Voltage A B C D H
RS31-60A 63A 690V 78 50.5 15 30 60 201
RS31-80A 80A 690V 78 50.5 15 30 60 201
RS31-100A 100A 690V 78 50.5 15 30 60 201
RS31-125A 125A 690V 78 50.5 15 30 60 201
RS31-160A 160A 690V 78 50.5 15 30 60 201

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-4
690V Square Pipe Fuses
Characteristics Curve

Type gG Type aR

Time-Current Range

Time-Current Range

Time-Current Range

Breaking-Current Characteristics

Breaking-Current Characteristics

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-4
www.nepeanpower.com
3 Phase Fuse Carrier

Dimensions

Ordering Information
Part Number Description
3 Phase Fuse Carrier
DS-3-690
Disconnect Switch 690V

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-4
www.nepeanpower.com
3 Phase Fuse Carrier
Disconnect Switch
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The NEPEAN Power fuse disconnecting switches are used with high short-circuit current and motor circuit as power,
disconnecting or emergency switches for AC protection. Our switches have rated insulation voltage up to AC 50Hz 800V,
working voltage up to 690V and working current up to 630A. This switch complies with GB14048.3 and IEC/EN60947-3.

These switches feature a design with half sealed structures made up of two parts: the seal and the cover (melt-loading
device). Our design is manufactured with a focus on reliable operation, convenient fuse installation and removal and a
small requirement for manual operation power.

Technical Specifications Ordering Information


Rated Insulation Voltage 800V Part Number Description
Rated Operational Voltage 690V 3 Phase Fuse Carrier
DS-3-690
Rated Operation Current 160A Disconnect Switch 690V
Conventional Free Air Thermal
160A
Current with Fuse-Links
NH Fuse-Link Size 00
Weight 700g

Dimensions

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-4
415V Fuses
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The RG0 range of fuses from NEPEAN Power offers protection against overload and short-circuit in electric lines (type
gG), also available for protection of semiconductor parts and equipment against short-circuit (type aR) and protection
of motors (type aM). Rated voltage of 415V. Rated current up to 32A. Working frequency 50Hz AC. Rated breaking
capacity up to 80KA. Compliant with GB13539 and IEC269.
Features
• Variable cross-section fuse element made from pure copper or silver sealed in cartridge made from high-duty
ceramic or epoxy glass
• Fuse tube filled with chemically treated high-purity quartz sand as arc-extinguishing medium
• Dot-welding of fuse element ends to the terminals ensures reliable electric connection and forms insert knife type
contacts
• Striker may be attached to the fuse link to provide immediate activation of microswitch to give various signals or cut
the circuit automatically

Ordering Information
Rated Rated Current Overall Dimensions Weight
Part No. Voltage Specifications
(g)
(V) (A)
A C ΦD E F
RG0 415V 2A 415V 2A 32 59 13.5 11 0.8 15.2
RG0 415V 4A 415V 4A 32 59 13.5 11 0.8 15.2
RG0 415V 6A 415V 6A 32 59 13.5 11 0.8 15.2
RG0 415V 10A 415V 10 A 32 59 13.5 11 0.8 15.2
RG0 415V 16A 415V 16 A 32 59 13.5 11 0.8 15.2
RG0 415V 20A 415V 20 A 32 59 13.5 11 0.8 15.2
RG0 415V 25A 415V 25 A 32 59 13.5 11 0.8 15.2
RG0 415V 32A 415V 32 A 32 59 13.5 11 0.8 15.2

Maximum Voltage Rating 500V

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-4
415V Fuses
Characteristic Curve

Fuse Carrier
Part No 0442
Rated Voltage 690V
Rated Current 32A
Matched with Fuse
RG0 415V 1-32A
Body Measurement
Overall Dimension See figure

Note: H - both sides of the connection, WH - bottom


of wiring, P - feet wiring, BHA - one leg wiring

Fuse Carrier - Rated up to 690V

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-4
www.nepeanpower.com
415V Square Pipe Fuses
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

NEPEAN Power’s range of 415V Square Pipe Fuses offer superior protection against overload and short-circuit in electric
lines (type gG) and protection of semiconductor parts and equipments against short-circuit (type aR). These fuses have
a rated voltage up to 415V, a rated breaking capacity up to 120kA and a working frequency of 50Hz AC. These fuses are
suitable for a variety of different industry requirements with a range to suit rated currents. Our fuses are manufactured in
compliance with GB13539 and IEC269.
Features
• Variable cross-section fuse element made from pure copper or silver sealed
in cartridge made from high-duty ceramic material
• Fuse tube filled with chemically treated high-purity quartz sand as arc
extinguishing medium
• Dot-welding of fuse element ends to the terminals ensures reliable electric
connection and forms insert knife type contacts
• Indicator or striker may be attached to the fuse link to show cutout of fuse
or to give various signals and to cut the circuit automatically
RS32 Series - Type gG (Normal)
Rated Rated Dimensions (mm) Weight
Part Number
Current Voltage A B C D H (g)
RS32 250A gG 250A 415V 135 68 20 46 58 447

RS32 Series - Type aR (Fast)


Rated Rated Dimensions (mm) Weight
Part Number
Current Voltage A B C D H (g)
RS32 250A aR 250A 415V 135 68 20 46 58 447

RS39 Series - Type aR (Fast)


Rated Rated Dimensions (mm) Weight
Part Number
Current Voltage A B C D E F H G (g)
RS39 900A aR 900A 415V 200 90 50 97 150 16.5 113 8 2470

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-4
415V Square Pipe Fuses
Characteristics Curve

Time-Current Range

Time-Current Range

Breaking-Current Characteristics

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-4
www.nepeanpower.com
1000V Fault
Limiting Fuses
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The RS range of fuses from NEPEAN Power offers protection against overload and short-circuit in electric lines (type gG),
also available for protection of semiconductor parts and equipment against short-circuit (type aR). Rated voltage up to
1000V and current up to 1600A. The breaking capacity of the fuses is up to 100kA. They are compliant with the IEC269-1/
IEC269-4 and GB13539.1/GS13539.4.

Features
• Variable cross-section fuse element made from pure silver sheets which are sealed in the melting tube made of
high-density porcelain.
• Fuse tube filled with chemically treated high-purity quartz as arc-extinguishing medium.
• The two ends of the melting body are connected to the (knife) contactor by dot welding.
• Both knife contactors and board contacts available.
• Striker/indicator may be installed to the fuse link. When the fuse link breaks, signals are sent out
in the case of an indicator, or the switch is pushed to cut the circuit in the case of a striker.

Voltage Amps Dimensions Weight


Striker
Part Number
(V) (A) A B C D E F H ϕd (kg)
RS89B-1000A 1000 1000 70 107 150 105 50 16 120 14x23 2800
RS89B-1100A 1000 1100 70 107 150 105 50 16 120 14x23 2800
RS89B-1250A 1000 1250 70 107 150 105 50 16 120 14x23 2800
RS89B-1400A 1000 1400 70 107 150 105 50 16 120 14x23 2800
RS89B-1600A 1000 1600 70 107 150 105 50 16 120 14x23 2800

Fuse Blown Limit Switch


Our fuse blown limit switch is a type-k
indicator used for remote electrical indication
of fuse operation. This indicator is situated on
the fuse body using snap-on mounting.

Part Number Description


Fuse Blown Limit Switch to suit
170H0069
RS89B fuse

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-4
1000V Fault Limiting Fuses
Characteristics Curve

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-4
www.nepeanpower.com
1000V Fault
Limiting Fuses
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and technologies.
Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The RS range from NEPEAN Power offer high speed fuses in a square body with flush end contact. Rated at voltages up
to 1000V. This series of fuses are mainly used in circuits of AC 50Hz, and rated current up to 2200Amp.
(Higher Amperages available on request). Ideal for the protection of semiconductor components and short circuit energy
limitation.

Features
• Constructed via variable cross-section fuse elements made of pure silver sheets sealed in the melting tube made from
epoxy glass fibre which is heat resistant.
• Fuse tube is filled with chemically-treated high-purity quarts as arc-extinguishing medium.
• The two ends of the melting body are connected to the (knife) contacts by dot welding.

Ordering Information
Max Dimensions
Amps Weight
Part Number Voltage
(A) A C D H md (kg)
(V)
RS-690-2000 1000 2000 81 91 120 165 16 2216

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-4
1000V Fault Limiting Fuses
Characteristics Curve

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-4
www.nepeanpower.com
1000V Fuses
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The RG5 range of fuses from NEPEAN Power offers protection against overload and short-circuit in electric lines (type
gG), also available for protection of semiconductor parts and equipment against short-circuit (type aR) and protection
of motors (type aM). Rated voltage up to 1200V. Rated current up to 75A. Working frequency 50Hz AC. Rated breaking
capacity up to 80kA. Compliant with GB13539 and IEC269.

Features
• Variable cross-section fuse element made from pure copper or silver sealed in cartridge made from high-duty ceramic
or epoxy glass
• Fuse tube filled with chemically treated high-purity quartz sand as arc-extinguishing medium
• Dot-welding of fuse element ends to the terminals ensures reliable electric connection and forms insert knife type
contacts
• Striker may be attached to the fuse link to provide immediate activation of microswitch to give various signals or cut
the circuit automatically
Characteristics Ordering Information
The time current characteristics shown Rated Rated Dimensions/Size (mm) Weight
on rear page relate to mean pre-arcing Part No Voltage Current
(g)
(V) (A) A B C ɸD E F H ɸd
times and are accurate to within a
RG5-1A 1200V 1A 110 124 140 22 13 1.3 28 6.5 91
manufacturing tolerance of ± 10%
RG5-2A 1200V 2A 110 124 140 22 13 1.3 28 6.5 91
related to current.
RG5-4A 1200V 4A 110 124 140 22 13 1.3 28 6.5 91
AC Short-Circuit Performance RG5-6A 1200V 6A 110 124 140 22 13 1.3 28 6.5 91
The range has been tested to BS2692 RG5-10A 1200V 10A 110 124 140 22 13 1.3 28 6.5 91
as follows: RG5-16A 1200V 16A 110 124 140 22 13 1.3 28 6.5 91
• TAC & TSC - 63kA 1200V RG5-20A 1200V 20A 110 124 140 22 13 1.3 28 6.5 91
RG5-25A 1200V 25A 110 124 140 22 13 1.3 28 6.5 91
RG5-32A 1200V 32A 110 124 140 22 13 1.3 28 6.5 91
RG5-35A 1200V 35A 110 124 140 22 13 1.3 28 6.5 91
RG5-40A 1200V 40A 110 124 140 22 13 1.3 28 6.5 91
RG5-50A 1200V 50A 110 124 140 22 13 1.3 28 6.5 91
RG5-63A 1200V 63A 110 124 140 22 13 1.3 28 6.5 91
RG5-1-75A 1200V 75A 110 124 140 25.5 13 1.3 28 6.5 98

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-4
1000V Fuses
Characteristics Curve

1200V Fuse Carrier

Part No. 0459

Rated Voltage 1200V

Rated Current 63A

Matches with
fuse body RG5 1-63A
measurement
0459
1200V Fuse Carrier

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-4
www.nepeanpower.com
HV
Current Limiting Fuse
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and technologies.
Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The XRNT can be utilised in indoor systems of 50Hz and has a rated voltage of 12.0kV. Used together with other switch facilities such as
loading switches and vacuum contractors, it protects electric transformers and other electric facilities against over loading or circuit breaks.
It is also a necessary accessory for high-voltage switch boxes, circular circuit cabinets and high/low voltage toploading transformer substa-
tions.

Features Technical Specifications


XRNT HV Fuse-links have parallel connected pure silver fuse- Rated Rated
Breaking
elements. The design and method of production of the elements Part Number Voltage Current
Current (KA)
ensures narrow tolerances of time-current characteristics. The fuse (kV) (A)
elements are wound on a ceramic support and are attached to the XRNT1-12/3.15-50 12 3.15 50
silver plated connection caps by means of spot-welding. XRNT1-12/6.3-50 12 6.3 50
XRNT1-12/10-50 12 10 50
The connection caps are fitted inside the silver plated copper end XRNT1-12/16-50 12 16 50
caps by spot welding. The copper end caps themselves are press- XRNT1-12/20-50 12 20 50
fitted onto the porcelain tube which is glazed inside and outside. XRNT1-12/25-50 12 25 50
The end caps are furthermore mechanically fixed to the porcelain XRNT1-12/31.5-50 12 31.5 50
tube and additionally sealed by a durable elastic sealing medium. XRNT1-12/40-50 12 40 50
XRNT1-12/50-50 12 50 50
This sealing method has been proven over many decades of posi-
XRNT1-12/63-50 12 63 50
tive field experience and ensures tightness against ingress of hu- XRNT1-12/71-50 12 71 50
midity. XRNT1-12/80-50 12 80 50
XRNT1-12/100-50 12 100 50
XRNT1-12/125-50 12 125 50
XRNT1-12/160-50 12 160 50
XRNT1-12/200-50 12 200 50
XRNT1-12/315-50 12 315 50

Part Number Description


XRNT1-12CLAMP Fuse Clamp to Suit XRNT1-12 Fuses
- Need two per fuse.

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-4
HV Current Limiting Fuse
Dimensions

XRNT1-12kV
Note: ɸ A: ɸ 51mm(6.3 - 40A) ɸ 76mm(50 - 125A) ɸ 88(160 - 200A)

Time Current Characteristics

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-4
www.nepeanpower.com
HV Current Limiting Fuse
Cut-Off Current Diagram

Characteristics

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-4
www.nepeanpower.com
Fault Driven Power Supply
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and technologies.
Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The output of the Fault Driven Power Supply is 48Vdc and The Fault Driven power supply is also current limited to
used to trip circuit breakers and/or power other protective protect against overloading. Over loading may easily occur
devices. Primary input power to the Fault Driven Power if a shunt trip coil is left in circuit on power up, which may
Supply is 110Vac with a secondary power input of 3 circuits be the case in the event of an emergency stop button being
from current transformers on the mains input to the equipment operated and not released.
being protected.

The unit provides a regulated 48V supply capable of supplying If operating in Current Limit, a red LED on the front panel
a continuous 500mA with a short term pulse capability of 10A. will be on. If the current limit condition continues the unit will
This allows the Fault Driven Supply to be used to power both switch off to protect the power supply from overheating and
protection relays and also heavily rated shunt trip circuits on causing permanent internal damage. This second condition
main circuit breakers. is indicated on the front panel with an Over Temperature
LED.
Three additional outputs are provided which may be used
for monitoring or included as additional protection in control Ordering Information
circuits. These contacts are; Part Description
X0106 Fault Driven Supply 5A CT48 volt DC output
1) Mains Healthy, which closes when there is 110VAC present.
X0161 Fault Driven Supply 1A CT48 volt DC output

2) 48V Healthy which is operated when there is greater than


45V on the output terminals.

3) Shunt Trip voltage output, which may be used as a pseudo


no-volt circuit, this output turns on when the bus volts drops
from a healthy state (of greater than 45V) to 36V. This directly
connects the DC bus to the shunt trip terminal and is intended
to directly operate the shunt trip of a breaker. This would only
be used if it is intended that the main breaker is to be opened
upon loss of input supply.

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-5
Fault Driven Power Supply

Case Dimensions Mounting Cut Out

Rear Terminal Layout

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-5
www.nepeanpower.com
Air Circuit
Breakers

AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

General
YCW1 series Intelligent Air Circuit Breakers (ACB) are used for the distribution networks on AC 50Hz, 415V and 690V
circuits with rated current between 630A and 6300A. Mainly used for distribution systems the ACB offers protection including
short circuit, overload undervoltage, etc. The ACB has an intelligent protection system with modbus communications
including Current, Power, PF, Reactive Power monitoring, etc. The unit can be supplied as a fixed or withdrawable unit.

The products conform with IEC60947-1,IEC60947-2 standards.


Overall and Mounting dimensions

Installation and figure dimension of fixed type circuit breaker (Inm = 2000A 3P 4P)

Ordering Information
Part Number Description
YCW1-20-3P-16F YCW1-2000/3P 1600A Fixed CB
UV-110VAC, ST-110V AC, CC-110V AC, MT-110VAC Aux-110V AC, Modbus
YCW1-20-3P-16D YCW1-2000/3P 1600A Withdrawable
UV-110VAC, ST-110V AC, CC-110V AC, MT-110VAC
Aux-110V AC, Modbus
YCW1-32-3P-32F YCW1-3200/3P 3200A Fixed CB
UV-110VAC, ST-110V AC, CC-110V AC, MT-110VAC
Aux-110V AC, Modbus
YCW1-32-3P-32D YCW1-3200/3P 3200A Withdrawable
UV-110VAC, ST-110V AC, CC-110V AC, MT-110VAC
Aux-110V AC, Modbus

For more information please contact:


Innovation . Dedication . Specialisation
www.nepeanpower.com
P: +61 2 4088 2790
E: power@nepean.com
2-6
Air Circuit Breaker
Data
Type YCW1-2000 YCW-3200 YCW1-6300

Pole 3P, 4P 3P, 4P 3P, 4P

Using category B B B

Rated current In 630,800, 1000, 2000,2500,3000 4000,5000,6300


A 1250, 1600, 2000
Rated frequency Hz 50 50 50

Rated operation voltage Ue V 400, 660 400, 660 400, 660

Rated insulation voltage Ui V 800 800 800

Arcing distance mm 0 0 0

Rated impulse 8000 8000 8000


withstanding voltage Uimp V

Rated operation short 400V kA 40 50 100


circuit breaking capacity
Ics
600V kA 40 50 65
(O-t-CO)
Rated limiting short circuit 400V kA 65 80 120
breaking capacity Icu
(o-t-CO) 600V kA 50 65 75
Rated short time
withstanding current Icw 400V kA 45 65 100
(O-t-CO, AVS)
Operation life Per hour times 20 20 20
Electrical times 1000 500 500
Mechanical times 10000 10000 10000
Full breaking time ms 20~30 20~30 20~30

Full closing time ms 55~70 55~70 55~70

Power consumption 3P W 360 1200 2000

4P W 450 1750 2300


Resistance of each pole Fixed type µΩ 11 9 -
Draw out type µΩ 20 14 10
Dimensions (LxWxH) 3P fixed type mm 362 x 323 x 402 422 x 323 x 402 -
3P draw out type mm 375 x 461 x 452 435 x 471 x 452 -
4P fixed type mm 457 x 323 x 402 537 x 323 x 402 -
4P draw out type mm 470 x 461 x 452 550 x 471 x 452 -
Approximate weight 3P fixed type kg 41 55 -
3P draw out type kg 71 95 245
4P fixed type kg 51.5 65 -
4P draw out type kg 86 115 260

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com
2-6
www.nepeanpower.com
A-LC2A Water Leakage
Monitoring & Alarm Unit

AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

A - LC2A leak detection controller is a liquid leak detection device with simple operation and high-cost performance.
It can select different sensing sensitivities allowing it to be used in different detection environments and grade
requirements. The relay contact signal output can be integrated with various monitoring systems to realize remote
monitoring.
Features & Benefits
• Easy operation: The controller adopts standard
• Stable and reliable: Using industrial-grade electronic
industrial modules and DIN rail installation; on-site
components, not only ensures high sensitivity during
wiring can be easily completed through the wiring
detection, but also reduces false alarms caused by
terminals. When leakage occurs, the relay will act,
various external factors. It adopts a electromagnetic
and the leakage indicator will be on. After the risk is
compatibility design, with anti-surge, anti-static, anti-
eliminated, the controller will automatically return to the
EFT and other protection functions.
normal state without manual on-site operation
• Adjustable sensitivity: Choice of sensitivity - Low to
• One key silence function: There is a buzzer off button
High on the controller panel.
on the controller panel, and the internal buzzer can be
• Local sound and light alarm: When the liquid leakage turned off by this button.
is detected, the LED leakage indicator on the panel will
• 12-24VDC Power supply rated
always be on to give an alarm, and the internal buzzer
will sound an alarm.
Wiring

The water leak detection system is composed of controller, sensing cable and mounting accessories.

Sensor compatibility A - LC2A leakage sensing cables


General Features Maximum length 500 meters
Accuracy 100%
Storage temperature -40°C ~ 60°C (0°F~140°F)
Environmental rating Operating temperature -20°C ~ 50°C (32°F ~ 122°F)
Humidity 5~95% (non-condensing)
Power 12/24VDC, 3W
Relay contact Function NO/NC change-over relay output

For more information please contact:


Innovation . Dedication . Specialisation P: +61 2 4088 2790
www.nepeanpower.com
E: power@nepean.com
2-7
A-LC2A Water Leakage Monitoring & Alarm Unit

VCC: Power positive GND: Power negative

Sens: Sensitive adjustable knob


Run: Normal operation indicator
ALM: Leakage alarm indicator light
light
CLR: Buzzer mute switch

NC: Normally closed


COM: Common port
L1/L2: Water leak detectoon cable
NO: Normally open

Notes

• This product is an electronic device, please follow precautions to avoid damage to electronic components
• Do not modify or disassemble
• Do not touch with wet hands when power connected
• Before installing the device, check the rated voltage and power supply voltage
• When using the relay output, confirm the rated load of the device connected
• Avoid using organic solution during regular inspection and maintenance and use dry cotton yarn to wipe
• Avoid contact with metal filings, grease, pipe paint and other contaminants

Product Item Number Description

A-LC2A 1 x Non-location water leak controller (relay output)

A-LC1B-4 10 x Metres of Non-location water leak cable A-Lc1B4 (Only cable, no connectors)

A-LLW96 10 x Cable clip, cable can be fixed to the ground or wall

WLS - C0 - 24VDC 1 x Bundle, included as above

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com 2-7
www.nepeanpower.com
AM3SE Medium Voltage Overload
AVAILABLE FROM
NEPEAN ELECTRONICS

NEPEAN Power is a proven leader in the supply and manufacture of quality engineered solutions, products and
technologies. Established in 1994, through the commitment of our dedicated team we have become a supplier of choice.

The NEPEAN AM3SE relays have been designed with the intent to control, protect and monitor industrial
installations, public distribution networks and substations. Furthermore, they can be applied to be used as
part of a protection scheme for transformers and generator transformers. Additionally, they provide back-up
protection for HV and EHV transmission systems.
Features & Benefits Case Dimension
• Complete set of protection, related to application
• 5 Current input, 3 Voltage input, 11DI, 5DO
• Auxiliary power supply that adaptable to; AC220V,
DC220V, DC110V, AC110V; DC48V, DC24V
• 1 RS485 serial communication, IEC60870-5-103 and
Modbus -RTU
• 1 GPS for GPS timing
• Exceeding 200 sequence of event records, 400
system logs and 10 seconds tripping context records
• Powerful graphic programmable Logic
- 2 Characteristic
• Rich protection functions
- Feeder protection
- Transformer protection
- Voltage protection
• Measurements
- RMS voltage and current values
- Frequency
- Power factor
- RMs active power
• Control Functions
- Remote and local control
- Programmable switchgear interlocking

For more information please contact:


Innovation . Dedication . Specialisation P: +61 2 4088 2790
www.nepeanpower.com
E: power@nepean.com
2-8
AM3SE Medium Voltage Overload
Specifications

Rated input AC/DC220V, AC/DC110V, DC48V, DC24V


Power supply Range Rared Voltage ᵡ (1±20%)
Consumption ˂ 10W (DC)
Rated input AC 100V/100/√³V
Range 1 ~ 120V
Rated Voltage
Accuracy ±0.5%
Consumption ˂0.5A (single phase)
Rated input AC 5A/1A
Range 0.04In ~ 15In
Rated Current
Accuracy ±0.5%
Consumption ˂0.5A (single phase)
Rated frequency 50Hz or 60Hz
Frequency Range 45~55Hz or 60Hz
Accuracy ±0.1Hz
Rated Voltage AC/DC220V, AC/DC110V, DC48V, DC24V
DI Range Rared Voltage ᵡ (1±20%)
Consumption ˂1W (DC220v) (single channel)
Mechanical life ˃1000
Switching capacity ˃1000W, L/R = 40ms
DO
On current continuous ˃5A, short time (200ms) ˃30A
Interrupting capacity ˃30W, L/R = 40ms
Temperature -10° ~ +55°C
Environment Humidity 5% ~ 95% (No condensation and freeze inside)
Altitude ˂4000m
Wiring Diagram Ording Information and Variations

AM3SE-1A -1
1 1Amp CT
2 5Amp CT

-1A 220V AC
-1D 220V DC
-2A 110V AC
-2D 110V DC
-3A 48V AC
-3D 48V DC
AM3SE-3D -1 ~Held in stock

For more information please contact:


P: +61 2 4088 2790
E: power@nepean.com 2-8
www.nepeanpower.com

You might also like