750 kVA to 2500 kVA

25000 kVA when paralleled

#203, 1AA Cross, 2nd Main, East of NGEF, Kasturi Nagar, Bangalore - 560 043.

MOHALI Office No. 2, 3rd Floor, SCF-29, Above Capital Finance Bank, Phase-V, SAS Nagar, District-Mohali

Authorised Dealer for :


"GENSET MODEL (4 stroke water cooled)
SP 750 EP SP 810 SP 910 SP 1010 SP 1125/SP 1250 (S)*
(1500RPM (50Hz) 3 Ph., 415V, 0.8 PF)"
1125kVA / 900kWe
Supernova Diesel Electric Gensets are powered by Perkins Diesel Engine ranging from 400kVA to 2500kVA. Each Rated kVA / Rated kW 750kVA / 600kWe 810kVA / 648kWe 910kVA / 728kWe 1010kVA / 808kWe 1250kVA / 1000kWe
Supernova Diesel Electric Genset is manufactured under stringent quality assurance process and undergoes in-house Engine Model 4006D-E23TAG2 4008D-E30TAG1 4008D E30TAG2 4008 30TAG2 4008 30TAG3
testing. Engine performance corresponds to ISO 3046, BS 5514 and DIN6271. The technical data applies to an engine Engine Bhp 895 965 1071 1206 1336 / 1481
operating on a fuel with a calorific value of 42.7 MJ/Kg(10200 Kcal/Kg) and a density of 0.86 Kg/Liter and as per BS 6 VERTICAL IN-LINE 8 VERTICAL IN-LINE
No. of Cylinder & Arrangement
2869 Part 2 1998 Class A2 or ASTM D975D2. AC Generator performance corresponds to IEC-34, IS-4722
Governor ELECTRONIC
The unmatched fuel efficiency and ease of maintenance are the key factors which makes them preferred choice of Fuel System DIRECT INJECTION SYSTEM WITH UNIT INJECTORS
customers.
Bore X Stroke (mm x mm) 160 x 190

Compression Ratio 12.8:1 13:1

Market leading power density Starting System 24V DC ELECTRIC


No deration in power output up to 50 Deg. C. Lead Acid TYPE Battery 2 Nos. 180 AH
In-line cylinder configuration engine up to 1125kVA (Prime) Fuel day Tank Capacity (Ltrs) 990
Vee cylinder configuration engine up to 2250kVA (Prime)
Coolant Capacity incl.Radiator (Ltrs) 120 143
Excellent Power to weight ratio
High block load capability due to split exhaust system. Lube.Oil Capacity incl.Oil Filters (Ltrs) 113.4 153
Average loading of Engine is 80% as against industries standard up to 70-75%. Lube.Oil Specification API CI4 15W/40
Commonality of component over the entire series of Engine. Bare D.G. Set Dimen. (LxWxH) in mm NA 4700 x 2100 x 2560
Unit injection system with electronic governor to optimized fuel consumption.
Dry Weight (Approx.) DG Set Only (in kgs) NA 8500
Low Operating and maintenance cost
Service interval 500 hrs. / 1 Year Overall D.G. Set Dimen. (LxWxH) in mm 7000 x 2150 x 2518 7200 x 2600 x 2950

Coolant change interval 3 Years / 6000hrs. Total Wgt. incl. (Appr.) Acou. Encl. (in kgs) 10500 12500
Designed to provide excellent service access for Easy of Maintenance.
"GENSET MODEL (4 stroke water cooled)
Compact size for easier transportation and installation. SP 1250 SP 1500 SP 1700 SP 1850 SP 2000 SP 2250 SP 2500 (S)*
(1500RPM (50Hz) 3 Ph., 415V, 0.8 PF)"

Rated kVA / Rated kW 1250kVA / 1500kVA / 1700kVA / 1850kVA / 2000kVA / 2250kVA / 2500kVA /
1000kWe 1200kWe 1360kWe 1480kWe 1600kWe 1800kWe 2000kWe
Diesel Engine / AC Generator / base frame /
Engine Model 4012-46TAG0A 4012-46TAG2A 4012-46TAG3A 4016-61TRG1 4016-61TRG2 4016-61TRG3 4016-61TRG3
Standard Control Panel / Radiator / Silencer /
Engine Bhp 1497 1785 2006 2208 2377 2647 2925
Battery & Battery Cables / AVMs / First Fill of
Lub. Oil / First Fill of Coolant / D.G, Set Controller / No. of Cylinder & Arrangement 12VEE 16VEE

Fuel tank / Wiring Hardness / Sensors. Governor ELECTRONIC

Fuel System DIRECT INJECTION SYSTEM WITH UNIT INJECTORS

Bore X Stroke (mm x mm) 160 x 190

Compression Ratio 13.6:1 13:1

RATING GUIDELINES Starting System 24V DC ELECTRIC

PRIME POWER rating corresponds to ISO standard power for Lead Acid TYPE Battery 4 Nos. 180 AH
continuous operation. It is applicable for supplying electrical Fuel day Tank Capacity (Ltrs) 990
power at variable load for an unlimited number of hours 210 550
Coolant Capacity incl.Radiator (Ltrs)
instead of commercially purchased power. This is as per ISO
Lube.Oil Capacity incl.Oil Filters (Ltrs) 177 213
8528.
STAND BY POWER rating corresponds to ISO fuel stop power. It Lube.Oil Specification API CI4 15W/40
is applicable for supplying standby electrical power at variable Bare D.G. Set Dimen. (LxWxH) in mm 5400 x 2200 x 2650 5800 x 3000 x 3400
load in area with well-established electrical networks, in the Dry Weight (Approx.) DG Set Only (in kgs) 11700 12000 12400 16500 17500 17900 18900
event of power failure. No overload capacity is available with
Overall D.G. Set Dimen. (LxWxH) in mm 9112 x 2600 x 3760 10363x3300x3200 10363x3300x3945 10363 x 3300 x 4340
this rating.
POWER STANDARDS Total Wgt. incl. (Appr.) Acou. Encl. (in kgs) 19000 19300 24200 26400 27460 29630 30000

Engine Performance corresponds to ISO 3046, BS 5514, SAE


JI349 and DIN 6271. The technical data applies to an engine Service Support:
operating on a fuel with a calorific value of 42.7 MJ/Kg (10200 PAN India spares availability through strategically located stock points across the country. Services offered
Kcal/Kg.) and a density of 0.84 Kg/liter (7.01 Ib/US gal). Engine through a strong network of seven area offices and resident engineers located at Tier II and Tier III cities and
speed governing is in accordance with ISO 3046, Class A1 and through service dealers.
ISO 8528 Class G2.
NOTE: CONTINUOUS DEVELOPMENTS IN THE PRODUCT ENTITLES US TO CHANGE TECHNICAL SPECIFICATIONS, DIMENSIONS, SCOPE OF WORK ETC.
*Technical Detail are subject to change if recommended by principal manufacturer. *DG SET ARE STAND BY RATED. STAND BY MODEL ARE ALSO AVAILABLE IN OTHER RATINGS. PLEASE CONTACT US FOR MORE DETAILS.