Tutorial 3
Tutorial 3
Tutorial 3
1.
Figure 1
From Figure 1(assumed positive sequence), determine
a) Io
b) VBN
c) VCN
c) Is the circuit a balanced or unbalanced three-phase system
[Io=0A, VBN=227116.48V, VCN=222.36-115.79V]
2.
Figure 2
1
3.
.
Figure 3
From Figure 3 If Van = 2400 (assumed positive sequence), determine
a) Determine all phase currents.
b) Determine all line currents.
c) Draw their phasor diagram.
[Ian=16-36.87A, IaA=16-36.87A]
5.
Figure 4
From Figure 4, if the impedance Z in the balanced three-phase circuit is
600 + j450 (assumed positive sequence), determine
a) IAB,IBC and ICA.
b) IaA,IbB,IcC.
c) Draw the currents relationship at the load.
[IAB=92-36.87A, IaA=159.35-66.87A]
2
6. A balanced -connected load has an impedance of 360 + j105 /. The load is fed through a
line having an impedance of 0.1 + j1.0 /. The phase voltage at the terminals of the load is
33kV. The phase sequence is positive. Use VAB as the reference. Calculate
a) The phase currents
b) The line currents
c) The line voltages at the sending end
d) Draw the phasor diagram for currents relationship.
[IAB=88-16.26A, IaA=152.42-46.26A, Eab=33.1k0.43V]
7. A balanced three phase Y-connected generator with positive sequence has an impedance of 0.2 +
j0.5 / and an internal voltage of 120 V/. The generator feeds a balanced three-phase Y-
connected load hvaing an impedance of 39 + j29 /. The impedance of the line connecting the
generator to the load is 0.8 + j1.5 /. The a-phase internal voltage of the generator is specified
as the reference phasor. Calculate
8. A balanced three-phase load requires 480kW at a lagging power factor of 0.8. The load is fed
from a line a having an impedance of 0.005 + j0.025/. The line voltage at the terminals of the
load is 600V .