Features & Specifications: Click Here For Acrylic-Polycarbonate Compatibility Table For Suitable Uses
Features & Specifications: Click Here For Acrylic-Polycarbonate Compatibility Table For Suitable Uses
Features & Specifications: Click Here For Acrylic-Polycarbonate Compatibility Table For Suitable Uses
Number
Notes
LQM
D495,751 and 6,502,044. Other patents pending.
OPTICS — LEDs mounted on printed circuit boards. Low energy consumption – less than one watt. LED lamp
operates in normal (AC input) and emergency (DC input) modes.
The typical life of the exit LED lamp is 10 years.
ELECTRICAL — Dual voltage input capability (120/277V) and 120V through 277V for MVOLT with SD.
Low-voltage disconnect prevents excessively deep discharge that can permanently damage battery. Conveniently LED LAMPS
located test switch and LED provide visual and manual means of monitoring system.
Constant-current series charger minimizes energy consumption and provides low operating costs. Printed circuit
boards are 100% quality tested during manufacturing. Current-limiting charger circuitry protects printed circuit
boards from shorts. †
AC/LV reset (line latch) allows battery connection before AC power is applied and aids in preventing battery damage
from deep discharge. Specifications
Crystal oscillator timing system with watchdog protection for precision accuracy. Length: 11-3/4 (29.8)
Brownout protection is automatically switched to emergency mode when supply voltage drops below 80% of 7-5/8
Depth: 2 (5.1)
nominal. (19.3)
Height: 7-5/8 (19.3)
Battery: Sealed, maintenance-free nickel-cadmium battery delivers 90-minutes capacity to emergency lamps. Two-
state constant-current charge maximizes battery life and automatically recharges after battery discharge. Weight: 2.6 lbs (1.2 kgs)
11-3/4 2
Diagnostics: Single-point microcomputer control for all electronic features. All dimensions are inches (centimeters) (29.8) (5.1)
unless otherwise specified.
Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic status.
SELF-DIAGNOSTICS (SD and AELR option):
Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection.Self-
diagnostic testing for five minutes every 30 days and 90 minutes every six months. LISTINGS — UL damp location listed 50°-104°F (10°-40°C) standard. NOM Certified (see options). Meets UL924,
NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Meets all applicable FCC Title 47, Part
Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition. Continuously monitors 15, Subpart B requirements.
AC functionality.
WARRANTY — 5-year limited warranty. (Battery is prorated.) This is the only warranty provided and no
AELR option: STAR (Self-testing Automated Reporting) radio transmits monthly and annual test results and
other statements in this specification sheet create any warranty of any kind. All other express and implied
diagnostics information for automated reporting requirements.
warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/
For more information visit AcuityBrands.com/STAR
terms-and-conditions
INSTALLATION — Universal mounting canopy for top or end mount. Back mount standard for single face only. Easily
removed mounting knockouts. J-box pattern on back panel. Housing snaps to canopy with four positive-locking Note: Actual performance may differ as a result of end-user environment and application.
tabs. Cam-locking pin tightly secures housing to canopy. All values are design or typical values, measured under laboratory conditions at 25 °C.
Specifications subject to change without notice.
Ships standard with additional face plate.
† Exit Signs Certified in the CA Title 20 Appliance Efficiency Database.
LQM 1
S Stencil (blank) Black 3 Single face with R Red 120/277 Dual voltage (blank) AC only (blank) None
W White extra faceplate G Green MVOLT Multi volt 120-277, X2 Primary and secondary NOM NOM certified for Mexico 4
and color panel 50/60hz 2 AC inputs provided 3 SD Self-diagnostics 5
EL N Nickel cadmium battery AELR Automatic Emergency Lighting
Reporting 6
Notes
1 LQM available with Custom Signage. See spec sheet, Custom- 5 Only available with MVOLT and EL N operation. See Example for
Signage. ordering.
Accessories: Order as separate item. 2 Only available with EL N SD. See Example for ordering. 6 Only available with MVOLT EL N SD. AELR transmits monthly and
3 Not available with other options. Both circuits can be energized at annual test results and diagnostics information for automated
ELA WG1 Back-mount wireguard 7 ELA LQMUS12 12" stem kit 8 the same time. reporting requirements.
4 Available with stencil face and white housing only. Not available 7 See spec sheet ELA-WG.
with MVOLT EL N SD configuration. 8 See spec sheet ELA-Stemkits.
EMERGENCY LQM
LQM LED, Quantum®
SPECIFICATIONS MOUNTING
All dimensions are inches (centimeters) unless otherwise specified.
ELECTRICAL Shipping weight: 2.6 lbs. (1.2 kgs.)
Primary Circuit
Top Mounting
Typical Supply Input Max.
Type1 End Mounting
LED life2 voltage watts amps 4-1/2
(11.4)
120 .62 .05
Red LED AC Only 10 years
277 .69 .06
120 .62 .05
Green LED AC Only 10 years 8-3/8
277 .74 .06 5-5/8 7-5/8
(21.3)
120 .71 .05 (14.7) (19.3)
Red LED Emergency 10 years
277 .92 .06
120 .66 .05
Green LED Emergency 10 years
277 .70 .06 11-3/4 2
(29.8) (5.1)
BATTERY
Back Mounting
Nickel Cadmium
5-7/8
Notes
(14.9)
1 LED lamps operate in normal (AC input) and emergency (DC input) modes.
11-3/4
2 Based on continuous operation. The typical life of the exit LED lamp is 10 years.
(29.8)
3 At 77°F (25°C).
4 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced and tested
in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required
maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties.
5 Temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and
capacity.
LQM
EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 1-800-705-SERV (7378) techsupport-emergency@acuitybrands.com www.lithonia.com © 1993-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/28/22