36 Pneumatic - 1
36 Pneumatic - 1
36 Pneumatic - 1
SINGLE AISLE
TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME)
PNEUMATIC
This document must be used for training purposes only
PNEUMATIC
Pneumatic Level 2 (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Engine Bleed System Description (3) . . . . . . . . . . . . . . . . . . . . . . . . 16
Pneumatic System Warnings (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Pneumatic System Operation (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
APU Bleed Air SPLY/X-Bleed System D/O (3) . . . . . . . . . . . . . . . . 36
BMC Interfaces (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Pneumatic Leak Detection System D/O (3) . . . . . . . . . . . . . . . . . . . . 42
U3T06191 - U1QT0M0
value. The hot bleed air goes through an air-to-air heat exchanger
called the precooler. Fan discharge air modulated by the Fan Air Valve
(FAV), blows across the pre-cooler to maintain the temperature within
limits.
APU BLEED/EXTERNAL AIR
The left and right bleed systems are connected by a crossbleed duct.
A crossbleed valve enables their interconnection or isolation.
The APU can also be used for bleed air supply. This is usually done
on the ground for air conditioning and for engine start.
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 2
SINGLE AISLE TECHNICAL TRAINING MANUAL
stage 5 stage 9
U3T06191 - U1QT0M0 - UM36BA000000001
FAV : CONTROL TEMPERATURE PNEUMATIC MAX 200 C , START OPEN PADA TEMP200C
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 3
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 4
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36BA000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 5
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 6
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36BA000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 7
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 8
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36BA000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 9
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 10
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36BA000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 11
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 12
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36BA000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 13
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 14
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36BA000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEVEL 2 (2) May 10, 2006
36 - PNEUMATIC Page 15
SINGLE AISLE TECHNICAL TRAINING MANUAL
- the altitude is over 15,000 ft, the control solenoid is used when:
- the pack configuration is normal. - the ENGine BLEED P/B is selected "OFF",
- the ENGine FIRE P/B is RELEASED OUT,
IP CHECK VALVE The solenoid is automatically energized by the BMC in the following
cases:
The IP check valve protects the IP stage from reverse flow when the HP
- over-temperature downstream of the precooler - the heat exchanger
VLV is open.
outlet temperature sensor senses a temperature above 257°C (527°F),
PRV/CONTROL SOLENOID - overpressure downstream of the PRV when the pressure-regulated
transducer senses a pressure greater than 57 psi,
The PRV pneumatically regulates the bleed pressure around 44 psi. A - leak detection in pylon/wing/fuselage ducts and surrounding areas,
thermal fuse causes the valve to close in case of engine fire at 450°C - APU bleed valve not closed,
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) ENGINE BLEED SYSTEM DESCRIPTION (3) May 10, 2006
36 - PNEUMATIC Page 16
SINGLE AISLE TECHNICAL TRAINING MANUAL
- corresponding starter valve not closed. HEAT EXCHANGER OUTLET TEMPERATURE SENSOR
OPV The heat exchanger outlet temperature sensor, connected to both BMCs,
reads the regulated temperature downstream from the precooler. This
The Overpressure Valve (OPV), which is normally open, closes
temperature is shown on the ECAM and used to monitor the system.
pneumatically. The OPV starts to close at 75 psi. It is fully closed at 85
psi and opens again at around 35 psi.
NOTE: Note: for the enhanced system, the high outlet temperature
REGULATED PRESSURE threshold is decreased. If the precooler exchanger outlet
temperature reaches 240°C (464°F), the BMC generates a class
A transducer, connected to both BMCs, reads the regulated pressure 2 maintenance message - "AIR BLEED" - on the ECAM
downstream from the PRV. This pressure is indicated on the ECAM. STATUS page. An associated maintenance message
"Thermostat (THRMST), FAV or sense line" can be seen on
NOTE: Note: for the enhanced pneumatic system, the cooling efficiency the MCDU.
is increased due to a new heat exchanger.
TRANSFERRED PRESSURE
A transducer, connected to the related BMC, reads the transferred pressure
downstream from the High Pressure Valve (HPV). This pressure is used
to monitor the PRV and the HPV.
FAV/CONTROL THERMOSTAT
The Fan Air Valve (FAV) pneumatically regulates the fan airflow to the
precooler for bleed air temperature regulation at 200°C (392°F). The
U3T06191 - U1QT0M0 - UM36D1000000001
PRECOOLER
The precooler is an air-to-air heat exchanger.
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) ENGINE BLEED SYSTEM DESCRIPTION (3) May 10, 2006
36 - PNEUMATIC Page 17
SINGLE AISLE TECHNICAL TRAINING MANUAL
KONTROL PRV
UNTUK
CLOSE/OPEN
U3T06191 - U1QT0M0 - UM36D1000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) ENGINE BLEED SYSTEM DESCRIPTION (3) May 10, 2006
36 - PNEUMATIC Page 18
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) ENGINE BLEED SYSTEM DESCRIPTION (3) May 10, 2006
36 - PNEUMATIC Page 19
SINGLE AISLE TECHNICAL TRAINING MANUAL
X BLEED FAULT If an ENG 1 (2) BLEED FAULT occurs, the aural warning sounds, the
MASTER CAUT light comes on, the ENGine bleed valve closes and the
When the APU is running and the APU bleed is set to ON, if a X BLEED engine bleed fault light comes on. The failure is shown amber on the
FAULT occurs, the aural warning sounds, the MASTER CAUT light EWD associated to indications on the ECAM BLEED page. If bleed air
comes on. The failure is shown amber on the EWD associated to pressure located downstream from the engine bleed valve, or temperature
U3T06191 - U1QT0M0 - UM36W1000000001
indications on the ECAM BLEED page. The engines and the APU are located downstream from the pre-cooler is above the detection threshold,
running. The APU bleed is set to ON. If, after setting APU bleed air to above 4 bar (57 psi) or 257°C (495°F), the bleed valve is automatically
OFF, the X bleed valve position disagrees with the command logic, this closed.
warning is triggered. This warning also occurs, when the valve is stuck
to close and the APU bleed P/B is set to ON. The warning always occurs, NOTE: If the HP valve was open, the engine bleed valve closure causes
when there is a disagreement between the valve and the desired position. it to close.
If an ENG 1 (2) BLEED NOT CLoSeD occurs, the aural warning sounds,
the MASTER CAUT light comes on, the engine bleed fault light comes
on if the engine bleed valve is not closed automatically. The failure is
shown amber on the EWD associated to indications on the ECAM BLEED
page. The engine 1 bleed valve is not automatically closed, when the
APU bleed valve is open. The warning is the same if the engine bleed
BLEED APU PRIORITY.
valve is not automatically closed during engine start. APU BLEED ON VALVE PNEUMATIC ON ENGINE CLOSED
BLEED 1 (2) OFF
If a BLEED 1 (2) OFF occurs, the aural warning sounds, the MASTER
U3T06191 - U1QT0M0 - UM36W1000000001
CAUT light comes on, the ENG BLEED OFF light comes on if one
engine bleed is switched off. The failure is shown amber on the EWD
associated to indications on the ECAM BLEED page.
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM WARNINGS (3) May 10, 2006
36 - PNEUMATIC Page 21
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36W1000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM WARNINGS (3) May 10, 2006
36 - PNEUMATIC Page 22
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM WARNINGS (3) May 10, 2006
36 - PNEUMATIC Page 23
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 24
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D2000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 25
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 26
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D2000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 27
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 28
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D2000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 29
SINGLE AISLE TECHNICAL TRAINING MANUAL
NOTE: Note: if you set again the thrust levers in the idle position,
the HP VLV is open again.
U3T06191 - U1QT0M0 - UM36D2000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 30
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D2000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 31
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 32
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D2000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 33
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 34
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D2000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC SYSTEM OPERATION (3) May 10, 2006
36 - PNEUMATIC Page 35
SINGLE AISLE TECHNICAL TRAINING MANUAL
X-BLEED SYSTEM
The cross bleed (X-BLEED) valve permits the isolation or the
interconnection of the left and right bleed air systems. The OPEN manual
control is used for:
- cross supply of the packs,
U3T06191 - U1QT0M0 - UM36D3000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) APU BLEED AIR SPLY/X-BLEED SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 36
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D3000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) APU BLEED AIR SPLY/X-BLEED SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 37
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BMC INTERFACES (3) May 10, 2006
36 - PNEUMATIC Page 38
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36F1000000001
INPUTS
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BMC INTERFACES (3) May 10, 2006
36 - PNEUMATIC Page 39
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BMC INTERFACES (3) May 10, 2006
36 - PNEUMATIC Page 40
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36F1000000001
OUTPUTS
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BMC INTERFACES (3) May 10, 2006
36 - PNEUMATIC Page 41
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEAK DETECTION SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 42
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D4000000001
ROUTING
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEAK DETECTION SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 43
SINGLE AISLE TECHNICAL TRAINING MANUAL
NOTE: The wing loops A are connected to BMC 1 and wing loops B
to BMC 2. The crosstalk bus allows wing leak warnings to be
activated through an AND logic. The APU loop is connected
to BMC 1 only. The pylon loop is connected to the related
BMC.
U3T06191 - U1QT0M0 - UM36D4000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEAK DETECTION SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 44
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D4000000001
WARNING LOGIC
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEAK DETECTION SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 45
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEAK DETECTION SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 46
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D4000000001
FAULT LOGIC
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEAK DETECTION SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 47
SINGLE AISLE TECHNICAL TRAINING MANUAL
NOTE: APU and cross bleed (X-BLEED) valves do not close during
Main Engine Start (MES).
U3T06191 - U1QT0M0 - UM36D4000000001
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEAK DETECTION SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 48
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM36D4000000001
LEAK CONSEQUENCE
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) PNEUMATIC LEAK DETECTION SYSTEM D/O (3) May 10, 2006
36 - PNEUMATIC Page 49
AIRBUS S.A.S.
31707 BLAGNAC cedex, FRANCE
STM
REFERENCE U3T06191
MAY 2006
PRINTED IN FRANCE
AIRBUS S.A.S. 2006
ALL RIGHTS RESERVED