A318 - ATA 38 - WATER & WASTE - Diff To A320 - L3
A318 - ATA 38 - WATER & WASTE - Diff To A320 - L3
A318 - ATA 38 - WATER & WASTE - Diff To A320 - L3
A 318
ATA 38
Water & Waste
Diff. to A 320
ATA 104 L3
Lufthansa
Technical Training GmbH For Training Purposes Only
Book No: A318 38 Diff L3 Lufthansa Base Lufthansa 1995
For training purposes and internal use only.
Copyright by Lufthansa Technical Training GmbH.
All rights reserved. No parts of this training
manual may be sold or reproduced in any form
without permission of:
TOILET SYSTEM
TOILETSYSTEMDIFFERENCES BETWEEN THE A320 AND THE A318
On the A320, the Vacuum System Controller ( VSC ) controls and monitors the
vacuum system and sends information directly to the Forward Attendant Panel.
The VSC interfaces with other aircraft systems.
On the A318, the VSC function is integrated into the Cabinntercommunication
Data System ( CIDS ) director, the altitude data come from Cabin Pressure
Controller ( CPC ) via the System Data Acquisition Concentrator ( SDAC ).
Door switch information is send to the CIDS director via Decoder / Encoder
Unit ( DEU ) B.
US / F gs 11.07. 96 Page: 2
Lufthansa Technical Training
WATER & WASTE A318
WASTE DISPOSAL
38−31
DEU B DEU B
DEU B
2 LGCIU
FROM POTABLE
WATER SYSTEM
FROM / TO CIDS SDAC
FWD ATTENDANT PANEL DIRECTOR 1 RINSE
CFDIU VALVE
FLUSH VALVE
CABIN FLOOR
WATER SEPARATOR
VACUUM GENERATOR 37 MG
WATER SYSTEM
POTABLE WATER SYSTEM DIFFERENCES BETWEEN THE A319
AND THE A318
The main difference between the A319 and the A318 potable water systems is
in the quantity indication. The A319 potable water quantity transmitter goes
directly to the Forward Attendant Panel.
On the A318, the water quantity transmitter sends the information to a Decoder
Encoder Unit ( DEU ) B which in turn interfaces with the active Cabin
Intercommunication Data System ( CIDS ) director. Potable water quantity is
displayed on the new Flight Attendant Panel ( FAP ).
The service door OPEN information is still sent to the FAP, but through a DEU
B and the active CIDS director.
For Training Purposes Only
CABIN FLOOR
TO FWD LAVATORY
DIR2 PRESSURE FROM
AND GALLEY BLEED AIR SYST. TO AFT
LAVATORIES
TO FCU & C/R PANEL REGULATOR and GALLEY
DRAIN VALVE 4 MP M
QTY
GRD AIR PRESS. INDICATOR
DRAIN FULL
OVERFLOW INDICATOR
CABLE FILL / DRAIN VALVE POS.
CONTROL
CABLE CONTROL DRAIN POS. SWITCH 3MP
TOILET SYSTEM
CAUT
WATER / WASTE SELECTED
QUANTITY
WASTE QUANTITY WATER QUANTITY
FLUSH
CYCLE
100 100 50 %
AKTIVE
75 75
LAV A
Water
50 50
Heater
on De- +
press
25 25 Reset Pre
Warn. Select
0 0
CHECK LAVATORY:
LAV A
Prev
Page
For Training Purposes Only
Next
Page
TOILET SYSTEM
MCDU TOILET PAGES
Selecting TOILET line key on the SYSTEM REPORT/TEST page does not
give access to the TOILET SYSTEM page anymore.
< RETURN
CIDS1−TOILET SYS
LRU IDENTIFICATION
For Training Purposes Only
TABLE OF CONTENTS
ATA 38: WATER & WASTE . . . . . . . . . . . . . . . . . . . . 1
TOILET SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
WATER SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
TOILET SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
TOILET SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
TABLE OF FIGURES
Figure 1 Toilet System Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 2 Potable Water System Basic Schematic . . . . . . . . . . . . . . 5
Figure 3 Water / Waste Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 4 MCDU TOILET Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9