GST Fire Alarm System Version 202208

Download as pdf or txt
Download as pdf or txt
You are on page 1of 42

Fire Detection

& Alarm System


One-stop Fire Solutions
Parent Company Carrier

GST’s parent company, Carrier, is an outstanding global Our Fire & Security business encompasses a wide range of
provider of healthy, safe sustainable and intelligent residential, commercial and industrial systems, including
building and cold chain solutions with a world-class, fire and carbon monoxide detection, alarm signaling,
diverse workforce, headquartered in Florida, USA. With incident management, evacuation, monitoring fire, gas and
more than a century of expertise, we drive innovation while water mist suppression, fire and gas safety solutions and
putting our customers first, helping protect our planet, industrial equipment controls. Our security business offers
and inspiring and empowering our people. Through our access control and event monitoring, electronic locks,
performance-driven culture, we are driving shareowner hospitality solutions, mobile apps and credentialing, real
value by growing sales and investing strategically to estate access solutions, remote access management, video
strengthen our position in the markets we serve. management and video analytics.

Gulf Security Technology Co., Ltd. (GST)

Gulf Security Technology Co., Ltd, GST, is a key player in the Asia fire and security industry and a trusted provider of
comprehensive fire system solutions around the world. It is a subsidiary of Carrier (Carrier Global Corporation), an outstanding
global provider of healthy, safe sustainableand intelligent building and cold chain solutions with a world-class, diverse workforce.

GST provides a wide range of fire products and customized fire


system solutions tailored to the needs of different industries. With
a sales infrastructure that covers many countries and regions, and
includes a China-wide network of more than 150 sales offices and
several logistics centers, GST has become an important part of
Carrier’s global business.

To satisfy the needs of its global customer base, GST has established
extensive R&D facilities in Beijing and Qinhuangdao in northern China.
It constantly strives to develop innovative new technologies and
products. GST’s factory in Qinhuangdao is a large manufacturing base
producing intelligent electronic products that incorporate innovative
technology. To ensure superior product quality, it has advanced
manufacturing and inspection equipment and strong capabilities in
quality control and process management.

GST has earned a range of national and international certificates of


conformity to standards such as China’s CCC, the international UL,
the global LPCB, Europe’s CE, etc.

2 Fire Detection & Alarm System 1


Contents

P05 UL Listed Addressable Products

P15 UL Listed Conventional Products

P21 EN54 Addressable Products

P38 EN54 Conventional Products

P46 Explosion Proof Products

P52 Specified Detectors

P56 Gas Release Control Products

P59 Tools and Accessories

P63 Software

P65 System Diagram

P70 Emergency Voice Evacuation

2 Fire Detection & Alarm System 3


UL Listed Addressable Products

Leading innovative technology


Safeguarding lives and properties

4 Fire Detection & Alarm System 5


UL Listed Fire Alarm Control Panels

GST-IFP4M (Grey/Red)
GST-IFP4M-S (Small/Grey)
GST-IFP4M-S-R (Small/Red)
LC-401
Single Loop Card

LC-402
P-9966A Dual Loop Card
CAN Class A Network Card

P-9983
Fibre Network Card
P-9956-ModBus
ModBus Card for 3rd party interfacing

Intelligent Fire Alarm Control Panel

Complies with UL864 10th Edition standards. All circuit boards are installed in a metal cabinet optional in red or grey
color, providing a complete fire control system for most applications. Modularized structure allows the panel to meet
different requirements by adjusting the configuration. Very easy for installation, operation and maintenance. P-9981
Zone Display Panel (Bicolor)

Features
P-9982
Zone Display and Control Panel (Bicolor) P-9981F
• 7-inch touch screen Zone Display Panel (Fixed)
• Wide range power supply 100-240V 50/60Hz
• Support 1-6 loops in Class A style (additional battery box is required for 5 or 6 loops application)
• 242 addressable devices per loop mixing various types of devices, max. 1452 addresses
• History records of 100,000 events
• 2 Power Limited Class B Notification Appliance Circuits (NAC), total load max.2.5A/24VDC. The 2nd NAC can be set as AUX.
• “Walk test”, silent or audible
P-9982F MP-401
• Positive Alarm Sequence (PAS) per point
Zone Display and Control Panel (Fixed) Redundancy CPU Card
• Report device type mismatch and duplicated address
• CAN/Fiber Networking, Panel grouping
• Redundancy CPU
• Option connecting with BMS via optional Modbus Card or built-in BACnet (License for order optionally)
• Multi languages: Standard English language and other regional languages
• Cabinet color options: Grey, Red
• Cabinet size option: PR-400B
Regular( GST-IFP4M): 815mm*490mm*144mm; with Zone Display Panel option Thermal Printer (RS232)
Small(GST-IFP4M-S): 560mm*490mm*144mm; without Zone Display Panel option

UL is a registered trademark owned by UL LLC.

6 Fire Detection & Alarm System 7


UL Listed Fire Alarm Annunciator

GST-MNA2C(CAN)
GST-M200
GST-MNA2F(Fibre)

Intelligent Fire Alarm Control Panel

Adopts GST digital loop protocol for an intelligent fire alarm


system. 1/2 loops, wall- mounted, suitable for small to Network Annunciator
medium-sized projects.

Complies with UL864 10th Edition standards. All


circuit boards are installed in a metal cabinet,
optional in red or grey color, providing a complete fire
control system for most applications. Modularized
structure allows the panel possible to meet different
requirements by adjusting the configuration. Very
Features easy for installation, operation and maintenance.

• Single loop of 240 address


• Optional L200 to expand the 2nd loop/extra 242 addresses
• 100VAC to 230VAC, 50/60Hz
• 2 Style Y Notification Appliance Circuits (NAC)
• 3 fixed relay outputs for fire/fault/supervisory
• Optional USB printer interface Features
• Optional graphic monitor station connection
• Walk Test function
• Positive Alarm Sequence (PAS) per point
• Advanced user friendly programming software including ‘Fuzzy Logic’
• Programmable by keypad or by PC through P-9930 communication card • Receive message and send command (Reset, Silence, ACK, etc.) through network
• LCD display unit of 800 x 480, 7.0” color TFT LCD
• Capacitive touch screen
• History file 100,000 events capacity
• Password and key-protected non-volatile memory
• User programmable password

LC200 P-9930 P-M9930Modbus • Field-programmable or by pc with GST-IFPx-Def Defining Tool

Loop Card RS232 Communication Card RS232 ModBus Communication Card • Network interface:
GST-MNA2C: CAN, Class A
GST-MNA2F: Fiber-Optic, Class A
• Cabinet color options: Grey, Red

8 Fire Detection & Alarm System 9


UL Listed Intelligent Detectors

DI-M910X Series Detectors DI-M9103

Adopt the latest digital loop protocol compatible with GST UL listed intelligent Intelligent Rate-of-Rise and Fixed-Temperature Heat Detector
fire alarm control panels. With digital communication protocol, the detectors
can quickly raise an alarm signal with full features within seconds, suitable for • Electronic addressed, easy to rewrite on site
hotels, restaurants, office buildings, schools, banks, warehouses, libraries, • Semiconductor heat sensor analyzing temperature status
computer rooms, switch rooms, etc. • FT or FT/RoR heat detection mode programmable
• High sensitivity temperature sensor, fast response
• Highly reliable sensor, long life, high reliability
• Reed switch test
• Auto-diagnostic capability
• Fire LED allows 360° viewing
• Option to switch off polling LED avoiding light interference
• Built in alarm output circuit, each detector can connect to a remote indicator
DI-M9101 C-9314P and BP-9314

Intelligent Combination Heat Photoelectric Smoke Detector

• Electronic addressed, easy to rewrite on site


• Drift compensation, strong environmental adaptability, anti-pollution ability
DB-M01
• Fixed-temperature fire alarm via semi-conductor heat sensor that analyzes
Common Detector Base
temperature status
Waterproof design
• Fire LED allows 360° viewing
• Option to switch off polling LED avoiding light interference
• 2-level programmable sensitivities
• Reed switch test
• Auto-diagnostic for sensor fault and optical chamber dusty
• Removable innovative sensing chamber, easy for maintenance
• Built in alarm output circuit, each detector can connect to a remote indicator
C-9314P and BP-9314

DI-M9102 C-9314P
Remote Indicator
Intelligent Photoelectric Smoke Detector
BP-9314
• Electronic addressed, easy to rewrite on site Back Plate
• Drift compensation, strong environmental adaptability, anti-pollution ability
• Fire LED allows 360° viewing
• Option to switch off polling LED avoiding light interference
• Reed switch test
• Auto-diagnostic for sensor fault and optical chamber dusty
• Removable innovative sensing chamber, easy for maintenance
• Built in alarm output circuit, each detector can connect to a remote indicator
C-9314P and BP-9314

10 Fire Detection & Alarm System 11


UL Listed Intelligent Modules

DI-M9300 DI-M9319

Digital Single Input Module Digital Zone Monitor Module


DI-M9300 is used to connect the equipment which provides normally open or DI-M9319 is designed to connect conventional detectors into an addressable system.
normally closed dry contact output signals, such as Flow Switch, Zonal Valve, When any device reports fire signal, the module will transmit the signal to the fire
Fire Pump, etc. Once the module detects the action of the equipment, a signal alarm control panel which generates a fire alarm and displays the address of the
will be sent to the fire alarm control panel. module

• Miniaturized design, suitable for centralized installation • Miniaturized design, suitable for centralized installation
• Din-Rail mount or Surface mount • Din-Rail mount or surface mount
• Monitor normally open or normally closed dry contact input signal • Input port cable monitoring with 4.7K EOLR
• Input port monitored with 4.7K EOLR • Maximum 30 conventional detectors or manual call points can be connected to
• Electronic addressed, easy to rewrite on site each module
• Provides a FORM-C dry contact output with the capacity of 2A @ 30VDC
• Loop powered, low power consumption
• Normally-open or Normally-closed output automatically follows Input port to
change state
• Two indicators for fire and fault
• Electronic addressed, easy to rewrite on site
• Powered by loop and external 24V, Monitoring power supply

DI-M9301

Digital Single Input and Output Module


DC-M9503
DI-M9301 is used to connect equipment which needs to be the controlled by fire
Loop Isolator Module
alarm control panel, such as elevator, fire door, etc. It also can receive the action
DC-M9503 is Din-Rail module type isolator to be installed and terminated individually,
signal from the controlled equipment and send it to the fire alarm control panel.
protecting the loop by isolating the trouble part.

• Miniaturized design, suitable for centralized installation


• LED status indicator
• Din- Rail mount or surface mount
• Support Class A and Class B loop connection
• Normally open dry contact output with cable monitoring function
• Maximum 128 isolators can be connected to each loop
• Monitor normally open or normally closed contact input signal
• Maximum 50 devices between two isolators
• Input port monitored with 4.7K EOLR
• Automatically restore once the fault has been cleared
• Input port co-operates with output or works individually
• Loop powered, lower power consumption
• Electronic addressed, easy to rewrite on site
• Occupy one or two loop addresses
• Loop powered, low power consumption
GST-MBX22
GST-MBX29
DI-M9305 Module Box
Optional accessories for both UL and LPCB D series Din-Rail modules for centralized
Digital Single Riser Output Module
installation, include mounting strip and cable trunking.
DI-M9305 is designed to connect conventional VADs or notification devices and switch
GST-MBX22: 6 ~ 10 pieces modules GST-MBX29: 12 ~ 20 pieces modules
on/off the supply to end devices.

• Miniaturized design, suitable for centralized installation


• Din-Rail mount or surface mount
• Relay capacity 2A@30VDC or maximum 60W 70V/100V audio speakers
D-93TC1(1U)
• Supervised input and output port cable D-93TC2(2U)
• Double-contact relay switching 2 lines together
• Electronic addressed, easy to rewrite on site Din-rail Module Transparent Cover
• Powered by loop and external power input D-93TC1: Suitable for DC-9503E, DI-9300E, DC-M9503 and DI-M9300
• Low power consumption D-93TC2: Suitable for DI-9301E, DI-9305E, DI-9319E, DI-M9301, DI-M9305 and
DI-M9319

12 Fire Detection & Alarm System 13


UL Listed Intelligent Call Point and Sounder Base

UL Listed
UL Listed Products
Conventional Products

DI-M9204

Digital Manual Call Point


DI-M9204 adopts the latest digital loop protocol, semi-flush mount type. A
back box is supplied for surface mounting.

• Re-settable (non-breaking glass) via special key


• Dual activation indication
• Electronically addressed
• Friendly installation and test
• Wiring before termination

DI-M9402

Intelligent Sounder Base
DI-M9402 are compatible with GST-IFPXM series fire alarm control
panels, to provide panel level synchronized audio output after activated.

• Electronically addressed
• Plugged together with DI-M910x series detectors
• Sound Pressure Level≥85dB
• Sound Frequency 3100Hz
• Loop powered, low power consumption

14 Fire Detection & Alarm System 15


UL Listed Conventional Detectors

DC-M910X Series Detectors


DC-M9103
2 wire type with low power consumption, alarm equivalent resistance
680Ω, suitable to build a fire alarm system together with UL listed Conventional Rate of Rise and Fixed Temperature Heat Detector
conventional panels or addressable interface modules for hotel,
restaurant, office building, school, bank, warehouse, library, computer • Semiconductor heat sensor
room, switch room etc. • Dual Rate-of-Rise and Fixed-Temperature
• Rate-of-Rise detection can be disabled by programmer
• Strong environmental adaptability due to drift compensation
• Auto-diagnostic
• Reed switch test
• Fire LED allows 360° viewing
• Possible to switch off polling LED, avoid light interference
• Built in alarm output circuit, each detector can connect to a remote
indicator C-9314P and BP-9314

DB-M01
DC-M9101 Common Detector Base
Waterproof Design
Conventional Combination Heat Photoelectric Smoke Detector

• Smoke and heat sensor are integrated in mechanism and


circuitry structure
• 2 smoke sensitivity levels can be set
• Heat detection is based on FT

DC-M9102
C-9314P
Conventional Photoelectric Smoke Detector Remote Indicator

• Light scattering technology with high performance chamber BP-9314


• Suitable for detecting slow burning or smoldering fires Back Plate

16 Fire Detection & Alarm System 17


UL Listed Conventional Sounder Strobe

DC-M9413R(Red) DC-M9415R(Red)
DC-M9413W(White) DC-M9415W (White)

Wall Mount Strobe


Wall Mount Sounder Strobe

• Configure dB output, sounder signal, and strobe signal output as per environment • Field-configurable switch for desired candela output.
• 15 to 110 candela output, selectable user-friendly switch on the side of the device • Field-configurable jumper for the strobe signal output.
• The candela output switch remains clearly visible after final installation, staying • Synchronized operation requires connection to a NAC output, set to
locked in place to prevent unauthorized tampering. Synch Mode or to a DC-M9410 Signal Synchronization Module
• Synchronized operation requires connection to a NAC output, set to Synch Mode or • Comply with UL1638, UL1971
to a DC-M9410 Signal Synchronization Module
• Comply with UL464, UL1638, UL1971

DC-M9416R(Red)
DC-M9416W(White)

Ceiling Mount Sounder Strobe

• Field-configurable for desired dB output, temporal or steady sound


DC-M9414R(Red)
output and strobe signal output
DC-M9414W(White) • Field-configurable switch for desired candela output
• Synchronized operation requires to connect it to a NAC output set of
Wall Mount Sounder
• Synch Mode, or to a DC-M9410 Signal Synchronization Module
• Comply with UL464, UL1638, UL1971
• Configure dB output as per environment.
• Temporal or steady sounder output selectable
• Synchronized operation requires connection to a NAC output, set to Synch
Mode or to a DC-M9410 Signal Synchronization Module
• Comply with UL 464

DC-M9410

Signal Synchronization Module

18 Fire Detection & Alarm System 19


UL Listed Conventional Call Point & Sounder Base
System Diagram

DC-M9204
EN54 Addressable Products
Innovation Manual Call Point

DC-M9204 can be used with a compatible conventional fire alarm control panel or
addressable modules to send out alarm signal by pressing the glass if there is a fire.

• Re-settable (non-breaking glass) via special key


• Dual activation indication
• Friendly installation and test
• Semi-flush mount, with a back box for surface mount

DC-M9402

Conventional Sounder Base

DC-M9402 is compatible with GST-IFPXM series fire alarm control panels,


driven by panel NAC output or DI-M9305 single riser module output
providing synchronized audio output after activated.

• Both DC-M910x and DI-M910x compatible


• Sound Pressure Level≥85dB
• Sound Frequency 3100Hz

20 Fire Detection & Alarm System 21


EN54 Fire Alarm Control Panels

GST-IFP8
Intelligent Fire Alarm Control Panel

GST-IFP8 is a modularized, multi-loops fire alarm control


panel. It is capable to expand to 8 loops, network up to 100 LCIFP8
panels via class A and 240 panels via class B, perfect for small, Dual-Loop Card For additional loops
medium and large projects.

P-9935 P-9904
RS232 card for PC connection USB Printer Interface
• 15*40 LCD display
• Max. 999 zones, up to 140 with own alarm, fault/disable LEDs
• Non-Volatile Memory
• 3 alarm outputs, sounder/F.P.E/Alarm Routing
• Built-in sounder output 1A/24V
• Detector dirty report
• PAS and acknowledge function
• Multiple interface options: RS232, RS485, TCP/IP, CAN
P-9965A
• Built in printer P-9935ModBus CAN Class A Network Card

• Non-volatile memory ensures data is not lost even if power supply is accidentally removed ModBus Card for 3rd party interfacing

Models

P-9965
P-9935TCPIP CAN Class B Network Card
TCP/IP Network Card

• GST-IFP8 • English
• GST-IFP8-PT • Portuguese
• GST-IFP8-HU • Hungarian
• GST-IFP8-FR • French
• GST-IFP8-IT • Italian
• GST-IFP8-SP • Spanish P-9945RP
• GST-IFP8-TK • Turkish RS485 Repeater Card

LPCB is a registered trademark owned by BRE Global Limited

22 Fire Detection & Alarm System 23


EN54 Fire Alarm Control Panels

GST200N
Intelligent Fire Alarm Control Panel

GST200N Series includes GST200N-1for 1 loop and


GST200N-2 for 2 loops, capable to network up to 100 LC200
panels via class A and 240 panels via class B. It is Loop Card For additional 2nd loop
designed for small buildings like office, restaurant,
store, shop, etc., provide simple installation,
operation, and easy maintenance.

• 8 lines LCD display


P-9905 P-9901A
• Wide range power supply unit: 100-240VAC 50/60Hz Panel Printer
USB Printer Interface
• Non-Volatile Memory
• 30 zones with own alarm, fault/disable LEDs
• Manual buttons for each zone, to activate/silence sounder strobes
• Built-in sounder output, F.P.E output, alarm output
• Configurable N/O, N/C or 0.5A/24V
• Detector dirty report


PAS and acknowledge function
Walk test
P-9930TCPIP
• Built in RS485 repeater output (max. 10 repeaters) P-9930 TCP/IP Network Card

• Modbus interface for BMS connection RS232 card for PC connection

Models

P-9960A
P-9960 CAN Class A Network Card
CAN Class B Network Card

• GST200N-1 • Single loop, English


• GST200N-2 • Dual loops, English
• GST200N-HU • Single loop, Hungarian
• GST200N-PT • Single loop, Portuguese
• GST200N-SP • Single loop, Spanish
• GST200N-IT • Single loop, Italian P-9930ModBus
• GST200N-FR • Single loop, French ModBus Card for 3rd party interfacing

• GST200N-TK • Single loop, Turkish


• GST200N-RO • Single loop, Romanian

24 Fire Detection & Alarm System 25


EN54 Fire Alarm Control Panels EN54 Addressable Repeaters

GST100 GST-NRP00
Intelligent Fire Alarm Control Panel Network Repeater Panel

Minimized single loop addressable fire panel, designed GST-NRP00 Network Repeater Panel is based on
in accordance with EN54-2 standard, to achieve simple GST network technology, providing remote control
installation, operation and maintenance, which make it ideal and indication of the fire alarm system.
for smaller systems.

• Maximum 8 detection zones, each with independent fire LED, fault/disable LED and zone label • Provide remote display and control of system
• Class A loop, maximum capacity of 128 addressable devices • Password protected access levels
• 122×32 lattice LCD assisting the LED indicators to display important information • 8X18 characters LCD screen
• Non-volatile memory ensuring system data not lost on shutdown of power • 15 LEDs to display important information
• 3 relay outputs available which are SOUNDER OUTPUT (R+ and R-), ALARM OUTPUT and FAULT OUTPUT • Functional control of network panels
• Network-wide operation: Acknowledge, Silence, Reset
• Flush-mount or surface-mount structure
• Meet network protocol by selecting suitable network network card

P-9943 P-9960 P-9960A


RS485 Communication Card CAN Class B Network Card CAN Class A Network Card

For connecting repeater panel or network

26 Fire Detection & Alarm System 27


EN54 Addressable Repeaters EN54 Addressable Detectors

DI-910XE Series Detectors


GST852RP Adopt the latest digital loop protocol, compatible with GST LPCB listed intelligent
LCD Repeater Panel fire alarm control panels. With digital communication, the detectors can raise fast
alarm signal within seconds, with full features, suitable for hotel, restaurant, office
building, school, bank, warehouse, library, computer room, switch room etc.

A remote indication unit through LCD screen for GST


addressable system.In case of fire, it will display the fire
type, time and location details together with sound for
local notification. DI-9101E
DI-9101E-B

Intelligent Combination Heat Photoelectric Smoke Detector


• Large LCD display with backlight
• Mute and lamp test
• Electronic addressed, easy to rewrite on site
• Electrically addressing
• Drift compensation, strong environmental adaptability, anti-pollution ability
• RS485 network
• Dual FT& RoR fire alarm by semiconductor heat sensor analyzing temperature status
• Heat Detection: Class A2R
• Fire LED allows 360° viewing
• Option to switch off polling LED avoid annoying
• 2 levels sensitivities programmable
• Reed switch test, Self-diagnostic for sensor fault and optical chamber dust
• Easy for maintenance.
• Built in alarm output circuit, each detector can connect to a remote indicator C-9314P
• LPCB approved at EN 54-7 and EN 54-5
GST8903
• White and Black color options
Intelligent Graphic Repeater Panel

A remote indication through graphic layout for the GST DI-9102E


addressable system, also known as the MIMIC panel.
In case of fire or fault, a message will be displayed Intelligent Photoelectric Smoke Detector
indicating the specific position within the layout drawing,
providing a clear view of the exact location. • Electronic addressed, easy to rewrite on site
• Drift compensation, strong environmental adaptability, anti-pollution ability
• Fire LED allows 360° viewing
• Up to 100 LED indication points • Option to switch off polling LED avoid annoying
• Local buzzer alarm and mute • 2 levels sensitivities programmable
• Customized graphical layout to project requirement • Reed switch test for easy test
• Programmable to display zones or individual device • Self-diagnostic capability
• Programmable to indicate Fire, Action and Fault conditions • Removable innovative sensing chamber, easy for maintenance.
• RS485 network • Built in alarm output circuit, each detector can connect to a remote indicator C-9314P
• A3, A2, A1 sizes • LPCB approved at EN 54-7

28 Fire Detection & Alarm System 29


EN54 Addressable Detectors

DI-9103E DI-9105E

Intelligent Rate of Rise and Fixed Temperature Heat Detector Intelligent Reflective Beam Detector

• Electronic addressed, easy to rewrite on site Built-in microprocessor to reach high sensitivity application, suitable to historical
• Dual FT and RR fire alarm by semiconductor heat sensor analyzing buildings, warehouses, large storages, shopping malls, leisure centers, exhibition halls,
temperature status hotel lobbies, printing houses, clothing factories, museums, and prisons.
• A1R, A2S, BS, 3 detection class programmable
• High sensitivity temperature sensor, fast response
• Highly reliable sensor, long life, high reliability • Loop powered
• Reed switch test for easy test • Electronic addressed, easy to rewrite on site
• Self-diagnostic capability • Wide operating voltage range, large monitoring areas
• Fire LED allows 360° viewing • Built-in laser pointer and digital tube display facilitate the alignment between
• Option to switch off polling LED avoid light interference detector and the reflector, and greatly improve the on-site commissioning efficiency
• Built in alarm output circuit, each detector can connect to a • Combination of the emitting and receiving parts makes mounting easy and optical
remote indicator C-9314P pathway accurate
• LPCB approved at EN 54-5 • Intelligent self-adjustment, drift compensation of ambient data, such as dust
accumulation, positional excursion, and ageing transmitter
• Intelligent auto-judgment about fire alarm and fault
• Self-diagnostic function can monitor the internal fault
DB-01 • 4 sensitivity levels can be set in field to suit different applications
• Ingress protection is up to IP66 through glue-seal treatment for special
DB-01B
environment applications
• Attractive appearance
Common Detector Base
Waterproof weep hole design

DC-9504E

Base Mount Isolator


DC-9504E is a base type isolator, to use with DI series detectors
replacing DB-01, providing detector based trouble isolation

RF-9105R

Reflector

C-9314P

Remote Indicator

30 Fire Detection & Alarm System 31


EN54 Modules

DI-9300E DI-9302E

Digital Single Input Module Digital High Voltage Relay Module


DI-9300E is used to connect the equipment which provides normally open or DI-9302E provides output capacity 220VAC/5A, suitable to connect the high
normally closed dry contact output signal, such as Flow Switch, Zonal Valve, voltage equipment being controlled by the fire alarm control panel.
Fire Pump etc. Once the module detects the action of the equipment, it will
send the signal to the fire alarm control panel. • Miniaturized design, suitable for centralized installation
• Din-rail mount or surface mount
• Miniaturized design, suitable for centralized installation • Input port monitors either normally open or normally closed dry contact.
• Din-Rail mount or surface mount • Special onboard relay test button to test relay action instead of being
• Monitor normally open or normally closed dry contact input signal operated from FACP
• Input port monitored with 4.7K EOLR • High voltage terminals are covered by transparent cover protecting from
• Electronic addressed, easy to rewrite on site electric shock
• Loop powered, low power consumption • Input port can be programmed “self-answering”
• Electronic addressed with 1-2 address options, easy to rewrite on site
• Using GST-IFPxE series Panel, invert mode or normal mode can be set
• Loop powered, low power consumption

DI-9301E DI-9305E

Digital Single Input and Output Module Digital Single Riser Output Module
DI-9301E is used to connect the equipment which needs to be controlled by fire DI-9305E is designed to connect conventional VADs or notification devices, to
alarm control panel, such as elevator, fire door etc. It also can receive the action switch on and off the supply to end devices.
signal from the controlled equipment and send it to the fire alarm control panel.
• Miniaturized design, suitable for centralized installation
• Miniaturized design, suitable for centralized installation • Din-Rail mount or surface mount
• Din- Rail mount or surface mount • Relay capacity 2A@30VDC or maximum 60W 70V/100V audio speakers
• Normally open dry contact output with cable monitoring function • Supervised Input and Output port cables
• Input port monitors either normally open or normally closed dry contact • Double-contact relay switching 2 lines together
• Input port co-operates with output or works individually • Electronic addressed, easy to rewrite on site
• Input port monitored with 4.7K EOLR • Powered by loop and external power input
• Electronic addressed with 1-2 address options, easy to rewrite on site • Low power consumption
• Loop powered, low power consumption

32 Fire Detection & Alarm System 33


EN54 Modules EN54 Addressable Sounder Strobe

DI-9319E I-9401N

Digital Zone Monitor Module Addressable Sounder Strobe


DI-9319E is designed to connect conventional detectors into an addressable
system. When any device reports a fire signal, the module will transmit the • Electronic addressed, easy to rewrite on site
signal to the fire alarm control panel. • Red Plexiglas lens, hi-light red, striking, long-life
• Sound level over 80dB
• Din-rail mount or surface mount • Plug in structure for easy installation
• Input port cable monitoring with 4.7K EOLR
• Maximum 30 conventional detectors or manual call points can be
connected to each module
• Provides a FORM-C dry contact output with the capacity of 2A @ 30VDC
• Normally-open or normally-closed output automatically follows Input
port to change state
• Two indicators for fire and fault
• Electronic addressed, easy to rewrite on site
• Powered by loop and external 24V, monitoring power supply

I-9403/I-9404
DC-9503E
Intelligent Sounder Strobe/ Sounder
Loop Isolator
DC-9503E is Din-rail module type isolator to be installed and terminated individually, • Electronic addressed, easy to rewrite on site
preventing the whole loop from the troubled part. • Two parts construction with base mounted termination allows easy installation
• 16 programmable alarm tones
• Isolates faulty part of the loop in the event of a short circuit • Optional Evacuate + Alert mode
• Automatically restores once the fault has been cleared • Optional loop powered or external 24VDC powered
• LED status indicator • Optional power saving mode or normal mode
• Support Class A and Class B loop connection • I-9403 has High intensity LED cluster
• Maximum 128 isolators can be connected to each loop • I-9403 can program work in Light or Sound or Light plus Sound
• Maximum 50 devices between two isolators
• Loop powered, lower power consumption

DI-9309

Addressable Multi-Channel Interface C-94DB


DI-9309 provides an integrated solution for application of multi-input signals,
saving mounting space and installation cost. Deep Base
Use with I-9403, I-9404, C-9403, C-9404 for Surface Cable Entry.
• Max. 16 channels of independent inputs. The quantity can be set by
jumpers as required
• Two channels of independent dry contact outputs
• 3-18 consecutive addresses, changing with selected channel quantity
• Monitored power supply
• Monitored cable for open circuit and short circuit

34 Fire Detection & Alarm System 35


EN54 Addressable Sounder Base EN54 Addressable Call Point

DI-9405/DI-9406 DI-9204E

Addressable Sounder Base / Flashing Beacon Base Digital Manual Call Point

DI-9405/DI-9406 are base mount types, easily inserted between the detector • Incorporates digital loop protocol, fast and reliable
and base without cabling, to produce a sound and light alert in case of receiving • Re-settable (non-breaking glass) via special key
command from FACP, saving the cost of installation and wiring. • Dual activation indicator
• Electronic addressed, easy to rewrite on site
• Electronic addressed, easy to rewrite on site • Plug-in structure, easy installation and maintenance
• Sandwich structure for easy installation. No additional cable required • Semi-flush mount type with a back box for surface mount
• Loop powered
• Three programmable modes,Share 1 address with detector or
individual control in single-address / double-address mode
• 16 selectable tones
• Used with D series detectors and bases
• Bright red high-intensity, 1Hz frequency flash light (DI-9406 model)"

D-92WPB

Waterproof Box

• IP65 cover offers full protection of manual call point


• Meets the requirement of 2 step Operation
• Clear and durable PC cover
• Surface mounting enables the easy installation
• 60mm hole distance and enough internal space for most types of MCP
• Reserved location for additional micro-switch, battery, buzzer, etc

D-92FC

Flip Cover

• Material: PMMA
• Suitable with D series manual call point for double action
• Prevent from accident trigger
• Dimension: 87 X 92 X 20 (mm)
• Thickness: 1.7mm

36 Fire Detection & Alarm System 37


N54 Conventional EN54 Conventional Panels

oducts
GST102A GST108A
EN54 Conventional Products GST104A GST116A

• Mains supply, 220/230VAC, 50/60Hz


• 2,4,8 or 16 zones, Each zone can have maximum 32 conventional detectors
• Compatible with GST conventional products
• Options to program supervisory zones, with individual supervisory indicator and supervisory relay output
• Provide fire, fault, aux. power, sounder output and disablement relay output
• Integrated charger and battery management program, fully complies with EN54-4 standard
• Easy operation to enable/disable zones, sounder outputs and alarm output
• Output programmable for interlink between zones and sounder outputs, alert or evacuate tone, with or without delay
• Alarm output and Fault output are available for integrating into third-party system
• Reserved repeater panel interface for fire alarm indication of multiple zones
• With AEOL solution to keep cable continuity even with detector removed
• Optional relay board to provide zone wised fire/fault relay output

RB102A RB104A RB108A RB116A

Relay Board for GST102/4/8/116A

38 Fire Detection & Alarm System 39


EN54 Conventional Panels EN54 Conventional Detectors

GST101 DC-910XE Series Detectors

1 Zone Conventional Fire Alarm Panel Have built-in microprocessor, are highly fixed with reliable fire judging
program, ensuring stable and reliable performance, with the new
• Mains supply, 220/230VAC, 50/60Hz designed smoke chamber and intelligent program, suitable for hotels,
• Maximum 15 conventional detectors, non-limited manual call points restaurants, office buildings, schools, banks, warehouses, libraries,
• Available sounder and fault output computer rooms, switch rooms, etc.
• Indicate normal status, fault, alarm and check cables for short or broken circuit
• Integrated management program for charger and battery • Strong environmental adaptability due to drift compensation
• Self-diagnostic
• Reed switch test
• Fire LED allows 360° viewing
• Possible to switch off polling LED avoid annoying
• A remote indicator C-9314P can be connected to each detector

GST-RP16 DC-9101E
DC-9101E-B
Conventional Repeater Panel

Conventional Combination Heat Photoelectric Smoke Detector


• Compatible with GST102A/4A/8A/16A
• Powered from FACP directly
• Smoke and heat sensor are integrated in mechanism and circuitry structure
• Provide Zonal Fire and general Fault indication
• 2 smoke sensitivity levels can be set
• Maximum 16 zones with fire signal
• Heat Detection: Class A2R
• Direct connecting, easy commissioning

DC-9102E

Conventional Photoelectric Smoke Detector

• Light scattering technology with high performance chamber


• Suitable for detecting slow burning or smoldering fires
• 2 smoke sensitivity levels can be set

DC-9103E

Conventional Rate of Rise and Fixed Temperature Heat Detector

• Semiconductor heat sensor


• Dual Rate of Rise and Fixed Temperature
• 3 detection classes can be set A1R, A2S & BS

40 Fire Detection & Alarm System 41


EN54 Conventional Detectors

DB-01 DC-9105E
DB-01-B
Conventional Reflective Beam Detector

Common Detector Base


Associated with D series detectors Built-in microprocessor to reach high sensitivity application, suitable to historical

Color options: White and black buildings, warehouses, large storages, shopping malls, leisure centers, exhibition halls,
hotel lobbies, printing houses, clothing factories, museums, and prisons.

• 24V powered
• Wide operating voltage range for monitoring large areas
• Built-in laser pointer and digital tube display facilitate the alignment between the
detector and the reflector, and greatly improve the on-site commissioning efficiency.
• Built-in normally open fire relay and normally closed fault relay dry contact output
• Combination of the emitting and receiving part makes mounting easy and optical
pathway accurate
DB-01D • Intelligent self-adjustment, drift compensation of ambient data, such as dust
accumulation, positional excursion, and ageing transmitter
Diode Detector Base • Intelligent fire alarm and fault auto-judgment
• Self-diagnostic function can monitor the internal fault
• 4 sensitivity levels can be set in field to suit different applications
DP-9907
• Ingress protection is up to IP66 through glue-seal treatment for special
environment applications
Active End of Line
• Attractive appearance
DP-9907 associated with DB-01D for Conventional System, to keep loop
continuity while a detector is removed

C-9314P

Remote Indicator
RF-9105R

Reflector Plate

42 Fire Detection & Alarm System 43


EN54 Conventional Sounder Strobe and Call Point

C-94XX Series Sounder Strobes GST-JL

Are notification devices, provide audile/visual warning Alarm Bell


signals to draw attention or evacuate in case of emergency. Suitable for factories, workshops, hotels etc. to provide clear and continuous
alarm sound.

• 24VDC power, 23mA operation


• 6” bell, 95dB@3m
C-9401N

Conventional Sounder Strobe

• 24VDC powered
• Red plexiglas lens, hi-light red, striking, long-life
• Sound level over 80dB
• Two-part plug-in structure for easy installation DC-9204E

Innovation Manual Call Point

• Non-addressable, alarms by pressing the glass


• Re-settable (non-breaking glass) via special key
• Dual activation indication
• Friendly installation and test
C-9403/C-9404
• Wiring before termination

Conventional Sounder Strobe/Sounder

• Two-part construction with base mounted


termination allows for easy installation
• 2 selectable alarm tones
• Strobe provided by high intensity LED cluster

C-94DB

Deep Base

Use with I-9403, I-9404, C-9403, C-9404


for Surface Cable Entry

44 Fire Detection & Alarm System 45


Explosion Proof Products

Explosion Proof Products DI-9204Exd


Digital Flame-proof Manual Call Point

Explosion Proof Products DI-9204Exd is applicable to vessels, Zone 1 and 2 of


explosive gas atmosphere and explosive dust atmosphere. It
is also suitable for outdoor applications.

• Work either in addressable or conventional mode


• Operating Voltage: 24V
• Ingress Protection: IP65
• Material: ZL102 aluminum alloy, red
• Dimension: 211mm x 129mm x 95mm
• Ex Mark: II 2 G Ex db IIB T6 Gb,-40°C≤Ta≤+70°C
II 2 D Ex tb IIIC T80°C Db
• ATEX Certificate: Presafe 14 ATEX 5549X

D-9105RExd
Digital Flame Proof Reflective Beam Detector

D-9105RExd is applicable to either commercial


areas or hazardous industrial areas, such as Zone 1
and 2 of explosive gas areas and Zone 21 and 22 of
combustible dust areas.

• Work either in addressable or conventional mode


• Operating Voltage: 24V
• Ingress Protection: IP66
• Material: Stainless steel, metallic gray
• Dimension: 344mm x 240mm x 212mm
• Ex Mark: Ex dIIC T6 Gb/Ex tD A21 IP66 T85°C
• Ex Certificate: CE16.1388X

46 Fire Detection & Alarm System 47


Explosion Proof Products

DC-910X(IS) Series Detectors


DI-9104Exd
Digital Flame Proof UV Flame Detector Are applicable to Zone 1 and Zone 2 of areas with explosion-proof
requirements in petroleum and chemical industries.
With an explosion proof interface I-9332, the detectors can be connected
into the GST addressable system. Max.10 pieces (mixed) can be linked to
each interface.

DI-9104Exd detects fire by picking up the ultraviolet light


from flaming material. It’s designed for areas where an • Strong environmental adaptability due to drift compensation

open fire is liable to occur due to a large amount of radiation • Self-diagnostic

and no smoldering stage. This detector can be applicable to • Reed switch test

zone 1 and 2 of explosive areas. • Fire LED allows 360° viewing

• Work either in addressable or conventional mode


• Operating Voltage: 24V DC-9101(IS)
• Ingress Protection: IP66
• Material: ZL102 aluminum alloy, silvery grey Intrinsically Safe Combination Heat
• Dimension: 147mm x 106mm x 92mm Photoelectric Smoke Detector
• Ex Mark: Ex d IIC T6 Gb
• ATEX Certificate: Presafe 14 ATEX 5547 • 3 smoke sensitivity levels
• FT and RR
• Ex Mark: Exib II CT6 Gb
• Ex Certificate: CE21.0155

DC-9102(IS)

D-9107RExd Intrinsically Safe Photoelectric Smoke Detector


Digital Flame Proof Dual IR Flame Detector

• Integrated algorithm for high sensitivity


• Ex Mark: Exib II CT6 Gb
• Ex Certificate: CE21.2424

D-9107RExd uses two pyroelectric infrared sensors


to detect the change of light signal of flame and DC-9103(IS)
background light signal at two bands of infrared
spectrum through individual processing channels. The Intrinsically Safe Rate of Rise and
detector is applicable to explosive Zone 1 and 2, and Fixed Temperature Heat Detector
flammable dust atmosphere.
• BS and A1R
• Ex Mark: Exib II CT6 Gb
• Work either in addressable or conventional mode • Ex Certificate: CE22.3906
• Operating Voltage: 24V
• Ingress Protection: IP65
• Material: Stainless steel, metallic gray
• Dimension: 166mm x 235mm x 199mm DB-01(IS)
• Ex Mark: II 2 G Ex db IIC T6 Gb /
Intrinsically Safe Detector Base
II 2 D Ex tb IIIC T80°C Db
• ATEX Certificate: Presafe 14 ATEX 5548X

48 Fire Detection & Alarm System 49


Explosion Proof Products

GST Intrinsically Safe Conventional Notification I-9332

Suitable to Zone 1 and Zone 2 of areas with explosion-proof requirements in Intrinsically Safe Interface for Detectors/Manual Call Point

petroleum and chemical industries. With Intrinsically Safe Interface, these


conventional devices can be connected into the GST addressable system. I-9333

Intrinsically Safe Interface for Sounder/ Strobe

The Intrinsically Safe Interface connects conventional intrinsically filed devices into
the GST addressable fire alarm system, reporting the alarms with address or receiving
the command from the panel to activate explosion-proof devices in the field. GST
DC-9202(IS)
Intrinsically Safe Interface provides a cost effective and reliable application for the
explosive area.
Intrinsically Safe Conventional Manual Call Point

• Photoelectric isolation technology for output signal, the interface is safe to use
Ex Mark: Exib II CT6 Gb
and can restrict the interference of industrial frequency
Ex Certificate: CE21.0157
• Electronic addressing, which can be modified in field
• Microprocessor monitors running status
• Built-in safety barrier, connecting with explosion-proof devices directly
• Cast aluminum alloy, silver grey IP65
• I-9332 reports the alarms with address to panels
• I-9333 receives the command from the panel to activate explosion-proof devices
in field and limit the energy limitation to the hazard area
DC-9403(IS)

Intrinsically Safe Conventional Sounder Strobe

Ex Mark: Exib II CT6 Gb


Ex Certificate: CE22.3905 GST-AS-200

Zener Safety Barrier 1 line fused

GST-AS-300

Zener Safety Barrier 2 lines fused

Associates with intrinsically safe products to provide protection by limiting the energy
DC-9404(IS) into an explosive environment. It ensures the energy output always be controlled
under a safe value in case of any kind of fault condition.
Intrinsically Safe Conventional Sounder
• Max. Output Voltage: Uo=28V
Ex Mark: Exib II C T6 Gb • Max. Output Current: Io=93mA
Ex Certificate: CE22.3907 • Ex Mark: [ExibGb] II C

50 Fire Detection & Alarm System 51


Specified Detectors

Specified Detectors GST Gas Detectors

These devices have a built in MCU, high quality semiconductor gas sensor
to achieve high sensitivity and reliability. When leakage of home use
combustible gas (LPG, Natural Gas ) is detected, detectors will generate
a high buzzer alert sound, and provide a dry contact to turn the exhaust

Detector
fan, a 12VDC source to switch off the gas valve. Very suitable to be used in
houses, hotels and apartments.

I-9602LW-LPG
I-9602LW-NG

Addressable Gas Detector


-Liquefied Petroleum Gas
-Natural Gas

• Operating Voltage: 24VDC


• Addressable: Compatible with GST FACP system
• Alarm Threshold: LPG: 2000×10-6 (10%LEL)
NG: 3000×10-6 (6%LEL)
• Ingress Protection: IP30

C-9602LW-LPG
C-9602LW-NG

Standalone Gas Detector


-Liquefied Petroleum Gas
-Natural Gas

• Operating Voltage: 187VAC~253VAC


• Alarm Threshold: LPG: 2000×10-6 (10%LEL)
NG: 3000×10-6 (6%LEL)
• Ingress Protection: IP30

52 Fire Detection & Alarm System 53


Specified Detectors

Ultraviolet Flame Detector

Detects fire by analyzing ultraviolet radiation of flame. It's applicable

R6601 to the places where open fire with intense flame radiation but without
enough smoke happening, or where quick response to a fire is required.
R6602

Conventional Smoke Detector


Conventional Heat Detector

R660X series are 4-wire type detectors, usually applied to a


I-9104
security system, or standalone with relay output. Detectors
Intelligent Ultraviolet Flame Detector
provide a normally open contact, which will be closed when the
detector alarms.
• High sensitivity, reliable performance, dust-proof, damp-proof
and corrosion-proof
• Operating Voltage: 12VDC (9.6VDC~14.4VDC)
• Three sensitivity levels
• Output Relay: 30VDC/1A
• Electronically addressed in field
• Cabling Method: 4-wire, 2 for power, 2 for output
• Built-in microprocessor stores 14 history data
• Ingress Protection: IP23(R6601))
• Auto-diagnostic
IP33(R6602))

C-9104

S-9102R Conventional Ultraviolet Flame Detector

S-9102N
• High sensitivity, reliable performance, dust-proof,
damp-proof and corrosion-proof
Stand Alone Smoke Detector • Auto-diagnostic

GST standalone smoke detector is battery powered with an adapting


optical chamber to detect smoke produced by fire. The detector
provides a high-volume sound notification in case of alarm and is
suitable for small projects, such as home applications, small shops,
pubs, etc.
S-9102R has a photoelectrical isolated polarized N/O contact output
S-9102N is networkable, suitable for group usage of detectors
DZ-03
• • Operating Voltage: 2-AA LR6 alkaline batteries
Common Detector Base
• • Battery Life: Around 3 years in normal operation
• • Detection Area: 60-100m2
• • Alarm Sound: >80dB@3m

54 Fire Detection & Alarm System 55


Gas Release Control products

Gas Release Control


Gas Release Control Products
Products GST301

Conventional Gas Extinguishing Control Panel


The GST301 is a standalone gas extinguishing control panel, provides
2 conventional detection zones to achieve double knock control, and
an additional standard fire detection zone for other areas. The Duty and
Standby Cylinder control can be automatically- and manually-controlled
controlled, with an adjustable delay timer

• Mains supply: 220/230VAC, 50/60Hz


• Backup Battery: 7AH/24VDC
• Sounder Output: 0.5A/24VDC
• Release Output: 2A/24VDC, Pulse
• Built-in PSU and charger for 24 hour standby and 30 minute
activation period

GST303( 3 zones)
GST306( 6 zones)

Addressable Gas Extinguishing Control Panel


The gas panel sits directly on addressable loop, achieving extinguishing
control by carrying out the intelligent equations on the fire panel.

• Mains supply: External Power Supply 24VDC


• Cylinder Output: Pulse (5s) or Continuous output, Max. 2A
• Release Indicator: 300mA/24VDC
• Sounder Output: Dry-contact, 1A/24VDC
• All cables monitored for fault of open circuit and short circuit
• Delay timer and release output period adjustable

56 Fire Detection & Alarm System 57


Gas Release Control products
Power Supply Unit

C-9317 Tools and Accessories


Emergency Gas Override Control
C-9317 Emergency Gas Override Control is used to control the start and
stop of gas extinguishing system, usually installed in areas to be protected.
Self-latched buttons resettable by a special tool
A dedicated contact output for sending start signal
The start and stop buttons are protected by a glass cover to prevent from
mis-operation

C-9318

Gas Extinguishing Warning Indicator


C-9318 Gas Extinguishing Warning Indicator is the accessory of a gas
extinguishing system, usually installed above the entrance of the protected area.
Flashing Frequency:1.4Hz±20%
Material and color: Iron enclosure/ white,
with plexiglass in front/ white

C-9329

Gas Extinguishing Control Relay Module


C-9329 Gas Extinguishing Control Relay Module is to use with GST303 or
GST306 Gas Extinguishing Control Panel, to carry out gas release solenoid
control and cable monitoring.
Output contact: Rated 30VDC/ 2A
Plug-in structure for friendly application

58 Fire Detection & Alarm System 59


Tools and Accessories

P-9910B CAN100H-4/8/12/16
Handheld Programmer CAN Hub

A programming tool that can also be used to read the 4/8/12/16 Routes
parameters and set the working mode of those devices.

• Communication Distance: 3000 meters


• Handheld unit, portable tool
• Node capacity of each branch: 112
• Convenient operation
• Total system capacity based on panel models
• Quadruple digit alphanumeric LCD display
• Avoids loop interference of the whole system due to isolation between trunk and branch, branch and branch
• Low-consumption hibernation and power saving function
• Low battery indication

P-9903 CAN100F CAN100S


Loop Relay Module Fiber Optic Converter CAN Relay

Convert CAN signal to Fiber Optic, expand Extends CAN network distance an additional
P-9903 expands loop distance, also provides strong communication distance up to 25km Transmission 3000 meters and node capacity to 112
protection for signals when the loop runs through heavy Medium:Single mode fiber
interference area.

• Enhance loop distance and reliability


• Increase 1000 meters of loop distance
• Maximum 2 pieces of relays can be connected in serial
• Opt-isolated output signal, resistant to industrial interference
• Output supports Class B loop connection only

60 Fire Detection & Alarm System 61


Power Supply Unit

GST Intelligent Power Supply Unit (PSU)

GST PSU is designed to support heavy consumption applications, for the fire Software
alarm devices requiring external 24VDC power supply. The built-in charger and
maintenance-free sealed lead acid batteries ensure the standby supply.

PSU24-5
PSU24-5A (Networkable)

• Mains Supply: 230VAC+10%/-15%, 50/60Hz


• Rated Output: 5A/26.5V DC GstGMC3.0 Client

• Backup Battery: 12Ah/24VDC Last alarm information: none


Fire Action Fault Disable

• Dimension: 400mm×318mm×128mm Auto Top Prev Next Last Enlarge Reduce System Exit
Project1

• PSU24-5A networkable, report fault of mains loose, battery test

loose or output broken to the fire panel Smoking Room

Office
Wash Room

Lobby

PSU24-10
1st Floor

PSU24-10A (Networkable) System message: Connection is ok between client and server Zoom : 100% Last alarm information: none 2016-07-01

• Mains Supply: 110VAC~230VAC, 50/60Hz


• Rated Output: 10A/26.5V DC
• Backup Battery: 24Ah/24VDC
• Dimension: 520mm×350mm×156mm
• PSU24-10A networkable, report fault of mains loose,
battery loose or output broken to the fire panel

62 Fire Detection & Alarm System 63


Software

GST Graphic Monitor Center


Fire alarm system monitoring software, designed by GST, to show the system diagram at a
computer screen. Equipped with a friendly interface to achieve remote monitoring and control.
System Diagram
Hardware Requirement Operation System
CPU: Pentium III 1G or above minimum free Windows 7, Windows 10 (IE8.0 or above)
Hard disk: 10GB Memory: 2GB or above GST-GMC also can be operated in Windows XP
Professional (IE6.0 or above)

GstGMC-M2.2
GstGMC3.0

• Supports 8 remote client stations plus local monitor station


• With OLE for Process Control (OPC), can be integrated into other systems
• Licensed with password
• GstGMC-M2.2 can be used with GSTM200 panels
• GstGMC3.0 can be used with GST200N and GST-IFP8 series panels

GST-IFPX-GMC-S/M/L

• New generation with creative technology, used with GST IFPX series
• Displays creatively with device icons and text window, to realize perfect explicitness.
• Supporting maximum 10 client stations
• Satisfy different projects from less than 500, between 500-2000 and more than 2000 addresses
• Licensed by a dongle key, safe even if the computer collapses

DEF-KEY
DEF-KEY-TIMER

USB Dongle Key


DEF-KEY is a security device. With a CPU or smart card, it will protect a definition database
configured with GST Def software and panel project configuration data from the unauthorized
approach. The person without the right Dongle Key is not permitted to enter the Def software or
create communication between the Def software and panels.
DEF-KEY can protect the system from a dangerous change and maintain the safe operation from
authorized configuration

DEF-KEY-TIMER is an advanced model, which allows customized validity and renewal.

64 Fire Detection & Alarm System 65


EN System Diagram

EN Product System Diagram

Sounder MCP Isolator UV Flame Heat Smoke


I-9403 DI-9204E DC-9503E I-9104 DI-9103E DI-9102E
Intelligent FACP Network Repeater
GST200N GST-NRP00

Intelligent FACP
Input Module Combination GST-IFP8
DI-9300E DI-9101E

CAN Network
Input/Output Module Monitor Module Addr.Beam
DI-9105E
Class A
DI-9301E DI-9319E

Conventional
Detectors Combination Smoke Heat Conv.Beam
DC-9101E DC-9102E DC-9103E DC-9105E

Hi-V Relay Module Gas Detector


Intelligent FACP Intelligent FACP
DI-9302E I-9602LW
GST200N GST200N

Intelligent FACP
GST-IFP8 Graphic Station
GST-GMC3.0

LAN Graphic Station


GST-GMC3.0

Graphic Station
Gas Release Output Interface Input Interface GST-GMC3.0
Panel I-9333 I-9332 Graphic Station
GST303 GST-GMC3.0

Intrinsically Intrinsically Safe LCD Repeater


Safe Sounder Combination GST852RP

Intrinsically Safe • CAN Network is possible to be Class A , Class B or Star Topology. Suitable network
Smoke
cards and accessories are available.
• External 24VDC Power Supply may be required by some devices.
Graphic Repeater • Max. 8 Remote Users can be connected to the host PC through LAN
Emergency Solenoid Valve GST8903
Switch Intrinsically Safe
C-9317 Heat

Warning Indicator
C-9318
Intrinsically Safe
MCP

66 Fire Detection & Alarm System 67


UL Listed System Diagram

UL Listed Product System Diagram

MCP Smoke Smoke Combination Single Input


DI-M9204 DI-M9102 DI-M9102 DI-M9101 DI-M9300
Sounder Base Combination
DI-M9402 DI-M9101

Isolator
Conventional Network Annunciator
GST-MNA2C/GST-MNA2F
DC-M9503 Detectors
Intelligent FACP
Heat Intelligent FACP
Smoke Combination Heat GST-IFP4M-S-R
DI-M9103 GST-IFP4M
DC-M9102 DC-M9101 DC-M9103

MCP
CAN/Fiber Network
DI-M9204 Class A
Zone Module
DI-M9319

Single I/O Isolatort


DI-M9301 DC-M9503 USB
Database/ FM
upgrade
External printer

Auxiliary 24V Output

Single Riser Module Network Annunciator Intelligent FACP


DI-M9305 GST-MNA2C/GST-MNA2F GST-IFP4M-S
Intelligent FACP
Intelligent FACP GST-IFP4M
Smoke Combination GST-IFP4M
DI-M9102 DI-M9101 Graphic Station
GST-IFPx-GMC

LAN Graphic Station


NAC Circuit GST-IFPx-GMC

Signal Sounder Strobe Sounder Strobe


Synchronization DC-M9413R DC-M9413W
DC-M9410
Graphic Station
GST-IFPx-GMC
MCP Graphic Station
DI-M9204 GST-IFPx-GMC

Sounder Strobe Sounder Strobe


DC-M9413R DC-M9416R

Isolator
DC-M9503
• Need additional CAN/Fiber network card to be installed into panel for networking
• Maximum 10 Remote Users can be connected to the host PC through LAN
• Maximum output of Panel NAC+ Auxiliary output is 2.5A

Smoke Heat Single Input


DI-M9102 DI-M9103 DI-M9300

68 Fire Detection & Alarm System 69


Emergency Telephone System

GST Fire Telephone panels

Emergency Voice Evacuation Specialized for emergency communication. Call from handset will be
transferred to networked fire telephone panels automatically after not
answered by the dedicated panel.

GST-FT8WN GST-FT24N

Fire Telephone Panel Fire Telephone Panel


8 Zone/Wall-Mount 24 Zone/19” Rack-mount

• Mains supply: 24VDC


• Conventional model
• Networkable up to 8 panels
• Each zone fully monitored of cable fault
• One zone failure won't affect other zones
• Network communication monitored

P-9911(H) P-9911(F)

Hands-free Speaker Fire Telephone Fixed Fire Telephone Handset

P-9911(M) P-9911(J)

Mobile Fire Telephone Handset Fire Telephone Jack

70 FireFire
Detection
Detection
& Alarm
& Alarm
System
System
03 /71
04
Emergency Voice Evacuation System

Emergency Voice Evacuation System GST-MP


Master Panel

GST-VES voice evacuation allows for emergency voice GST-MP is the Master Panel of the GST voice evacuation
announcements to evacuate people inside a building. With system. It provides the programing and operating
microphone, amplifier, and speakers, the system will release interface, operates in conjunction with the Fire Alarm
an alarm tone first, allowing the building manager or fire Control Panel (FACP) in a building to provide an automatic
supervisor to broadcast the tone through a microphone. response to life safety emergencies
GST Voice Evacuation System equipment meets National Fire GST provides two basic master panel models with the
Protection Association (NFPA) standard and is UL approved. option to be integrated into the Fire Alarm Control Panel.
GST-MP16 : 16 switches/LEDs and 16 inputs for FACP
with Cabinet
GST-MP16x: GST-MP16 without Cabinet, for integrating
into GST-IFP8-VT

Features GST-DP
Distributor Panel

• True Multiplex 6 Channel Audio


• Integrated Fire Phone
• Integrated 2 Channel Digital Message Repeater GST-DP is the Distributed Panels in the system. All
• Live Microphone Page to any zone GST-DP are connected to a master panel, receiving
• Fast RS-485 Communication Protocol the command and voice signal from GST-MP,
• Fully Supervised amplifying, and providing 25V or 70V audio source to
• Easy Installation and Operation the speaker directly.
• Natural Sound Voice Recordings GST provides 4 basic option of GST-DP
• Built-in Alarm and Alert Signals GST-DPS50, single channel, 50W
• Up to 4 Minute Message Capacity GST-DP50, dual channel, 50W
• Integrates with GST Fire Alarm Panel by RS232 or dry contact GST-DPS100, single channel, 100W
• Interfaces with non GST Addressable and Microprocessor-based Fire Alarm Panels GST-DP100, dual channel, 100W
• 2 Minute Message Restart on Microphone Key

72 Fire Detection & Alarm System 03 / 04 Fire Detection & Alarm System 73
Emergency Voice Evacuation System

MFP GVX-BA

Master Fire Phone Card Backup Amplifier Switching Relay


Accessory on master panel for fire phone. Add 1 MFP to GST-MP16 or GST- One required for each Distributed Amp when automatic switching /
MP16X if the fire phone is required. redundant amplification is needed On a Single Channel system the backup
amplifier can be located in any GST- DP panel. On a Dual Channel system
an additional AMI card, and EVX needed. #E Amplifier assembly is required
(the # represents the largest power amplifier in the system 50/100).

GST-MFH-A

Master Fire Phone Handset Assembly FPO2


Accessory on master panel for fire phone. Add 1 MFH to GST-MP16 or GST-
MP16X if the fire phone is required. Fire Phone Interface Terminal
One FPO2 provides 4 additional terminals for fire phone circuits. It is
required for the 2nd, 3rd and 4th FPI Fire Phone Interface in GST-DP.

SLC

Switch LED Card


Accessory on master panel. One SLC card provides 16 switches and LED's FPI
for manual control at Master Panel. Add SLC cards if more than 16 switch/
LED are required Fire Phone Interface
Each FPI provides 4 supervised class “B” fire phone circuits in a DP panel.
Maximum 2 FPI (8 phone circuits) can be installed in one GST-DP.

SSC
GVX-50E / GVX-100E
Switch Scan Card
Accessory on master panel. Each SSC card controls up to 8 switch/LED Amplifier Module

cards. One SSC card is included in the basic GST-MT master panel. GVX-50E is a 50W amplifier module and GVX-100E is a 100W amplifier
module. The amplifier module is included in basic GST-DP. Amplifier
modules may be ordered as spare or adding extra output power to GST-DP.
Max 2 amplifier modules can be mounted in one GST-DP.

GST-XI XFMR
Extended Input Interface card
Transformer
Accessory on master panel. One XI card provides 16 additional inputs to
This transformer is for amplifier module. 220VAC, 50Hz. It is required if
master panel. Maximum 7 XI can be connected to one II card.
additional amplifier is added to GST-DP.

MBK P-9935EVAX

Mother Board Relays Communication Card


One MBK card provides 4 class “B” speaker circuits. And two MBK cards This card provides interface between GST-IFP8-VT FACP and GST-MP via
provide 8 “class B” or 4 “class A” speaker circuits in one distributed panel. RS232 port. It is not required if the dry contact interface is employed.
One MBK card is included in basic GST-DP panel.

74 Fire Detection & Alarm System 75


Emergency Voice Evacuation System

Default
Part No. Product Description Max. QTY Max. QTY
QTY
Master panel, with 16 inputs,
GST-MP16 N/A N/A N/A
16 Switches/EDs, with Cabinet GST-VES system diagram
Master panel, with 16 inputs,
GST-MP16x 16 Switches/EDs, without Cabi- N/A N/A N/A
net
Distributed panel, Dual channels 50
GST-DP50 N/A N/A N/A
Watts, 4 Class B speaker circuits
Distributed panel, Single channel
GST-DPS50 N/A N/A N/A
50 Watts, 4 Class B speaker circuits
Distributed panel, Dual channels 100
GST-DP100 N/A N/A N/A
Watts, 4 Class B speaker circuits
GST- Distributed panel, Single channel
N/A N/A N/A
DPS100 100 Watts, 4 Class B speaker circuits
Optional components for Master Panel, More than 16 switches and
SLC Switch LED Card 1(1)(2) 64
LED’s required, another SLC is needed
SSC Switch Scan Card 1(1)(2) 8 Optional components for Master Panel, Every 8 SLC needs one SSC

MFP Master Fire Phone Card 0 1 Optional components for MP

GST-MFH-A Master Fire Phone Handset Assembly 0 1 Optional components for MP

Optional components for Distributed Panel, 4 supervised Class “B” Fire


FPI Fire Phone Interface 0 4
Phone circuits per FPI
Optional components for Distributed Panel, More than 1 FPI is required
FPO2 Fire Phone Output Adapter 0 3
in a Distributed Panel, one FPO2 card is needed for each
1(4) 1(4) Optional components for GST-DPS50, if converts from GST-DPS50 to
GVX-50E Amplifier Module
2(3) 2(3) GST-DP50, one GVX-50E is needed

1(6) 1(6) Optional components for GST-DPS100, if converts from GST-DPS100


GVX-100E Amplifier Module
2(5) 2(5) to GST-DP100, one GVX-100E is needed
Optional components for Distributed Panel, One additional MBK needed
MBK Mother Board Relays 1(3)(4)(5)(6) 2
for 8 Class “B” or 4 Class “A” Speaker Circuits on Distributed Panel.
Interface card between GST-IFP8 or GST-IFP8-VT and Master panel,
P-9935EVAX RS232 Communication Card 0 1
Provides communication between GST-IFP8 panel and GST-MP
1(4) (6) 1(4) (6) Optional components to convert single channel Distributed panel to
XFMR Transformer
2(3) (5) 2(3) (5) dual channels Distributed panel. One transformer required per amplifier

Optional components for Master panel, connect, connect with II


XI Extended Input Interface 0 7
Input Interface card, provides additional 16 inputs per XI card

(1) Configuration for GST-MP16 (4) Configuration for GST-DPS50


(2) Configuration for GST-MP16x (5) Configuration for GST-DP100
(3) Configuration for GST-DP50 (6) Configuration for GST-DPS100

Technical Specification

• Communications: RS-485 Standard, 1M Baud rate


• Primary Supply: 220VAC
• Backup Battery: 7AH/24VDC(GST-MP), 17AH/24VDC(GST-DP)
• Electrical Ratings: All Circuits @ 24VDC
• End of Line Resister: 10kΩ
• Maximum Cable Length: 4,000 feet, #16 AWG, between panels, 50,000 feet in the overall system
• Recommended Cable: 16 or 18 AWG, (Low-Capacitance) UTP Unshielded-Twisted Pair

76 Fire Detection & Alarm System 77


Emergency Voice Evacuation System

System Diagram - GST-VES with GST-IFP8-VT

78 Fire Detection & Alarm System 03 / 04 Fire Detection & Alarm System 79
IMPORTANT: This publication is a generic version in which product EMEA Headquarters
information is shown for informational purposes only and does not
constitute a specific commitment or guarantee. We are constantly Carrier Fire & Security EMEA BVBA
pursuing the improvement of product technology to improve product (Europe, Middle East & Africa)
performance, for which we reserve the right to adjust the configuration Pegasus Park - De Kleetlaan 3 1831
and technical information of the related products without notice. In Diegem · Brussels, Belgium
addition, the description of system performance in this publication Tel: +32 (0)2 725 1120
applies only to the usual situation. As a result, there may be a variety of Fax: +32 (0)2 721 4047
unpredictable special circumstances in the real world, so the realization E-mail: emea@carrier.com
of the relevant product performance will depend on the professional
investigation and analysis and the design plan. Please contact us and we
will be happy to provide you with professional advice. South East Asia

Carrier Fire & Security Singapore Pte Ltd


Add: 28 Teban Gardens Crescent, Singapore 608926
Tel: (65) 6506 1616
Fax: (65) 6298 7310
Email: Tuan.Truong@carrier.com

Taiwan, China

Carrier Fire & Security Ltd., Taiwan


Add: 15F., No.156, Sec. 1, Zhongshan Rd., Banqiao Dist.,
New Taipei City 220, Taiwan
Tel: +886 2 8964 3777 ext. 3236
E-mail: hsuan.liu@carrier.com

MEA

Carrier Fire & Security Products


Add: PO Box 30791 Palladium Building 203 & 209 Dubai,
United Arab Emirates
Tel. +971 4 4199000
E-mail: marketingme@carrier.com

India
Carrier Technologies India Ltd.
Add: Bren Optimus, No 8/2, 3rd floor, Dr M H Marigowda Road,
Adugodi, Bangalore -560029, India
Tel: +91-080-43442000
E-mail: central.communications@carrier.com

Gulf Security Technology Co.,Ltd


Carrier Global Corporation (Carrier)
12F, Building A, New Bund World Trade Center(I), No.4, Lane 255,
Dong Yu Rd, Shanghai 200126, China
ASIA: Tel: +86 21 38938223 Email: asiasales.gst@carrier.com
EMEA: Tel: +86 21 38938219 Email: emeasales.gst@carrier.com