Fluid Machineier
Fluid Machineier
Fluid Machineier
W
γ= γ= ρg
V
𝛄water = 9.81 KN/M3
V m
V̊ = m̊ =
Time Time
V̊ = A𝛎 m̊ = 𝛒V̊
m̊ = 𝛒A𝛎
Conservation of mass
m1+m2 = m3
Continuity Equation
m̊ = 𝛒A𝛎
𝛒1A1𝛎1 = 𝛒2A2𝛎2
1
Note: 𝜌 =
v
Water is incompressible so density can be erased.
Pressure
Absolute pressure
True pressure measured above perfect vacuum.
Gage pressure
is measured from the level of atmospheric pressure
by instruments like pressure gage and open-ended
manometer.
Atmospheric pressure
Local pressure measured by instruments like
barometers.
Gage pressure
Pg = γ∆z
Pg = γfh
Bernoulli’s Equation for pumps
Total head or total dynamic head, H
Is the total energy developed by the pump expressed
in height of liquid is the algebraic sum of pressure
head velocity head elevation head, and friction head.
Annotation:
H = Elevation change “height between the discharge
and suction points”
Pd = Pressure Discharge
Ps = Pressure suction
Vd = Velocity at the discharge
Vs = Velocity at the suction
Zd = Elevation at the discharge
Zs = Elvation at Suction
Hfd= Head loss due to friction Discharge
Hfs = head loss due to friction on suction
Annotation:
L= Total length
v= Velocity
D= Inside diameter
g= Gravitational acceleration
f= Coef. Of friction (taken from table)
Hydraulic or waterpower
Is the theoretical power necessary to raise a given
volume of liquid from a lower to a higher elevation.
Annotation:
γ = sp. Weight
Q = volume flow rate
H= Total Head of pump
Efficiencies on pumps:
Pump efficiency
Pw
ep=
Pb
Motor efficiency
Pb
em=
Pi
Overall Efficiency
Pw Pb
e=ep∗em= x
P b Pi
Pw
e=
Pi
Where:
Pw = waterpower
Pb = brake power
PI = input power
Specific (Critical) Speed of Pump
N = rpm
H = ft or m
Q = gpm or m3/s
Ns
N
√ Q
suction
¿¿
Affinity or similarity Laws
For Specific Centrifugal Pump
Q H P
1 2 3 N
1 2 3 D
( ) ( )( )
1 1
Q1 N1 D1
=
Q2 N2 D2
( ) ( )( )
2 2
H1 N D1
= 1
H2 N2 D2
( ) ( )( )
3 3
P1 N1 D1
=
P2 N2 D2
For Geometrically similar pump
Q H P
1 2 3 N
3 2 5 D
( ) ( )( )
1 3
Q1 N1 D1
=
Q2 N2 D2
( ) ( )( )
2 2
H1 N D1
= 1
H2 N2 D2
( ) ( )( )
3 5
P1 N1 D1
=
P2 N2 D2
___________________________________________
Capacity of Fan, Q
- Is the volume flow rate measured at
the fan outlet.
Q = Av
Where:
A = Fan outlet area
v = fan outlet Velocity
Total Head. H
- Is the sum of the static head and
velocity head of the air.
H = hs + h v
Static head, hs
- Is the height of the surface of the fluid
above a gauge point most of the time is
given in manometer reading height of
water.
Pwater = Pair
γwhw = γahs(a)
ρwhw = ρahs(a)