Atos - Axial Piston Pump - PVPC
Atos - Axial Piston Pump - PVPC
Atos - Axial Piston Pump - PVPC
1 MODEL CODE
PVPC X2E – C – 4 046 / 31044 / 1 D -I X 24DC 10 /*
Variable displacement Synthetic fluids:
axial piston pump WG = water-glycol
PE = phosphate ester
See notes in section
Eventual suffix for double pumps
X2E = with a fixed displacement
pump type PFE (see tab. A005) Series number
Size:
3 = for displacement 029 Solenoid of pilot valve:
-I = solenoid OI (DHI) for AC and DC supply
4 = for displacement 046
5 = for displacement 073 and 090
Max displacement of axial piston pump: Direction of rotation (viewed at the shaft end)
029 = 29 cm3/rev D = clockwise
S = counterclockwise
046 = 46 cm3/rev
073 = 73 cm3/rev
090 = 88 cm3/rev Shaft (SAE Standard) (1):
1 = keyed (7/8” for 029 - 1” for 046 - 1 1/4” for 073 and 090)
Type of PFE (for double pumps), see tab. A005 5 = splined (13 teeth for 029 - 15 for 046 - 14 for 073 and 090)
1) pumps with ISO 3019/2 mounting flange and shaft (option /M) are available on request
2 OPERATING CHARACTERISTICS
Max working pressure / Peak pressure [bar] 280/350 280/350 280/350 250/315
Max pressure on drain port [bar abs.] 1,5 1,5 1,5 1,5
Power consumption at 1450 rpm and at [kW] Fax = axial load
19,9 31,6 50,1 54,1
maximum pressure and displacement Frad = radial load
Type 1 Type 5 Type 1 Type 5 Type 1 Type 5 Type 1 Type 5
Max torque on the first shaft [Nm] Notes: For speeds over 1800 rpm the inlet port
200 190 230 330 490 620 490 620 must be under oil level with adequate pipes.
Max permissible load Fax 1000 1500 2000 2000 Maximum pressure for all models with option /WG is
[N]
on drive shaft Frad 1500 1500 3000 3000 160 bar, with option /PE is 190 bar.
Max speed with options /WG and /PE is
Speed rating [rpm] 600 ÷ 3000 600 ÷ 2600 600 ÷ 2200 600 ÷ 1850
2000/1900/1600/1500 rpm respectively for the four sizes.
A160
3 MAIN CHARACTERISTICS OF VARIABLE DISPLACEMENT AXIAL PISTON PUMP TYPE PVPC
Installation position Any position. The drain port must be on the top of the pump. Drain line must be separated and
unrestricted to the reservoir and extended below the oil level as far from the inlet as possible.
Suggested maximum line lenght is 3 m.
Ambient temperature from -20°C to +70°C
Fluid Hydraulic oil as per DIN 51524...535; for other fluids see section
Recommended viscosity 15÷100 mm2/sec at 40˚C (ISO VG 15÷100). Maximum start-up viscosity: 1000 mm2/sec
Fluid contamination class ISO 16/13 (filters at 10 µm value with ß10 ≥ 75 recommended)
Fluid temperature -20°C +60°C -20°C +50°C (seals /WG) -20°C +80°C (seals /PE)
SP-666 Connector IP-65, suitable for direct connection to electric supply source
SP-667 As SP-666 connector IP-65 but with built-in signal led, suitable for direct connection to electric supply source
6 INSTALLATION POSITION
VERTICAL INSTALLATION
D2
D2 D2
D2
B
A
IN IN
C
IN
C
D1
The pump is supplyed whit drain D2 open, INSIDE THE TANK INSIDE THE TANK OUTSIDE THE TANK, above oil level
and D1 plugged. Before installation fill the
Minimum oil level equal or above the pump Minimum oil level below the pump moun- Minimum inlet pressure = 0,8 bar absolute
pump with hydraulic oil for at least 3/4 of its
mounting surface. ting surface. B 800mm, C= 200mm
volume, keeping it in horizontal position.
A 200mm Minimum inlet pressure = 0,8 bar absolute
With exception of pump mounted below the
B 800mm, C= 200mm
oil level, we recomend to interpose a baffle
plate between inlet and drain line.
HORIZONTAL INSTALLATION
D2
D2 IN
C
D2
D2
B
IN
C
IN IN
INSIDE THE TANK INSIDE THE TANK OUTSIDE THE TANK, above oil level OUTSIDE THE TANK, below oil level
Minimum oil level equal or above the pump Minimum oil level below the pump moun- Minimum inlet pressure = 0,8 bar (absolute) C= 200mm
mounting surface. ting surface. B 800mm, C= 200mm
A 200mm Minimum inlet pressure = 0,8 bar (absolute)
B 800mm, C= 200mm
IN: inlet line - D1: drain line - A: minimum distance between inlet and drain line - B+C: permissible suction height - C: inlet line immersion dept
7 DIAGRAMS at 1450 rpm (based on mineral oil ISO VG 46 at 50°C)
= Qmax = Qmin
1 1 1
Efficiency [%]
Efficiency [%]
Efficiency [%]
2 2
2
Power consumption [kW]
3
4
Flow [l/min]
Flow [l/min]
Flow [l/min]
4 4
5 5 5
Efficiency [%]
2
the pump displacement, obtained with
4
Flow [l/min]
PVPC-*-3029 31 19
PVPC-*-4046 44 20
5
PVPC-*-5073 50 25 αmin
PVPC-*-5090 53 28 Operating pressure [bar]
Time [ms]
A160
8 HYDRAULIC AND ELECTROHYDRAULIC CONTROLS
Flow [l/min]
only the fluid required by the system.
Pressure may be steplessly adjusted at the
pilot valve.
Compensator setting range: 20 ÷ 350 bar
(315 bar for 090)
Compensator standard setting: 280 bar
(250 bar for 090) Pressure [bar]
Flow [l/min]
level.
Compensator setting range: 20 ÷ 350 bar
(315 bar for 090)
Compensator standard setting: 280 bar
(250 bar for 090)
Pressure [bar]
is consequently adjusted.
Load sensing control always incorporates an
hydraulic compensator to limit the maximum
pressure.
Compensator setting range: 20 ÷ 350 bar
(315 bar for 090)
Compensator standard setting: 280 bar Pressure [bar]
(250 bar for 090)
Differential pressure setting range: 10 ÷ 40 bar
Differential pressure standard setting: 14 bar
not supplied
Maximum
LW Constant power power
curve
In order to achieve a constant drive torque
Theoretical
with varying operating pressure. The swashing power
Flow [% of max]
PORTS DIMENSION
IN = Flange SAE 3000 1 1/4”
OUT = Flange SAE 6000 3/4”
D1, D2 = 1/2” BSPP
햲 = Regulation screw for max displacement 1,5 cm3/rev per turn. Adjustable range 50% to 100% of max displacement.
In case of double pump the regulation screw is not always available, please contact our technical office.
DRAIN PORT
DRAIN PORT
Mass: 18 kg
INTERMEDIATE FLANGE SAE “A” FOR PFE-31 INTERMEDIATE FLANGE SAE “B” FOR PFE-41
OR-2325
OR-3400
Drawing shows pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted
A160
10 DIMENSIONS OF PVPC-*-4046: BASIC VERSION “C” CONTROL
PORTS DIMENSION
IN = Flange SAE 3000 1 1/2”
OUT = Flange SAE 6000 1”
D1, D2 = 1/2” BSPP
햲 = Regulation screw for max displacement 2,2 cm3/rev per turn. Adjustable range 50% to 100% of max displacement.
In case of double pump the regulation screw is not always available, please contact our technical office.
OUTLET
INLET PORT PORT
IN OUT
DRAIN PORT
DRAIN PORT
Mass: 24 kg
INTERMEDIATE FLANGE SAE “A” FOR PFE-31 INTERMEDIATE FLANGE SAE “B” FOR PFE-41
OR-2325
OR-3400
Drawing shows pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted
11 DIMENSIONS OF PVPC-*-5073 and PVPC-*-5090: BASIC VERSION “C” CONTROL
INLET PORT
OUTLET
IN PORT
OUT
DRAIN PORT
PORTS DIMENSION
IN = Flange SAE 3000 2”
OUT = Flange SAE 6000 1 1/4”
D1, D2 = 3/4” BSPP
햲 = Regulation screw for max displacement
3,2 cm3/rev per turn.
Adjustable range 50% to 100% of max DRAIN PORT
displacement.
In case of double pump the regulation screw
is not always available, please contact our
technical office.
Mass: 33 kg
INTERMEDIATE FLANGE SAE “A” FOR PFE-31 INTERMEDIATE FLANGE SAE “B” FOR PFE-41
OR-2325
OR-3400
OR-3400
Drawing show pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted
A160
12 DIMENSIONS OF PVPC: OTHER CONTROLS
VERSION CH VERSIONS L, R
VERSION LW
햲 = Regulation screw for max displacement. Adjustable range 50% to 100% of max displacement).
In case of double pump the regulation screw is not always available, please contact our technical office.
Drawing shows pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted and also the consequently
position of the control groups
10/10