IS 15885(Part 2/Sec13)
■ Features ■ Applications
Constant Voltage + Constant Current mode output LED street lighting
Metal housing design with functional Ground LED architectural lighting
Built-in active PFC function LED bay lighting
No load / Standby power consumption <0.5W LED floodlighting
IP67 / IP65 rating for indoor or outdoor installations Type HL for use in Class I, Division 2
Function options: output adjustable via potentiometer; hazardous (Classified) location.
3 in 1 dimming (dim-to-off); Smart timer dimming; DAL I
Typical lifetime>50000 hours
5 years warranty
■ Description
ELG-200 series is a 200W AC/DC LED driver featuring the dual mode constant voltage and
constant current output. ELG-200 operates from 100~305VAC and offers models with different
rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 93%, with the
fanless design, the entire series is able to operate for -40 ℃ ~ +90 ℃ case temperature under free
air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series
to fit both indoor and outdoor applications. ELG-200 is equipped with various function options, such as
dimming methodologies, so as to provide the optimal design flexibility for LED lighting system
■ Model Encoding
ELG - 200 - 24 A -
{
Input wiring type
Function mode option
Blank:2-wire input for standard model
3Y:3-wire input for standard model
Rated output voltage(12/24/36/42/48/54V)
Rated wattage
Series name
EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to EN55015,EN61000-3-2 Class C (@load≧50%) ; EN61000-3-3;GB17625.1,GB17743;EAC TP TC 020; KC KN15,KN61547
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV);EAC TP TC 020; KC KN15,KN61547
MTBF 826.7K hrs min. Telcordia SR-332 (Bellcore) ; 200.8Khrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 244*71*37.5mm (L*W*H)
PACKING 1.22Kg; 12pcs / 15.2Kg / 0.72CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
NOTE
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De-rating may be needed under low input voltages. Please refer to STATIC CHARACTERISTIC sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. No load/standby power consumption is specified for 230VAC input.
8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
10.Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
11.The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
12.For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
File Name:ELG-200-SPEC 2018-09-30
144~200W Constant Voltage + Constant Current LED Driver ELG-200 series
Block Diagram
※ This series is able to work in either Constant Current mode (a direct drive way) or
Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.
In the constant current region, the highest voltage at the output of the driver
100 depends on the configuration of the end systems.
(B) Should there be any compatibility issues, please contact MEAN WELL.
Vo(%)
(A) Constant
Constant Current area
V oltage area
50
(min.)
(C)
Hiccup
Protection
50 100 Io(%)
DIMMING OPERATION
Vo-(Black)
ACN(Blue) Vo+(Red)
ACL(Brown) ELG-200
DIM+(Blue)*
DIM-(White)**
◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100%
90%
80%
+
Vo+ + 70%
Output current (%)
60%
-
Vo- - 50%
DIM+ 40%
- 60%
Vo- -
DIM+ 50%
40%
Additive Resistance
30%
DIM- 20%
10%
“DO NOT connect "DIM- to Vo-"
0%
Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N
(N=driver quantity for synchronized dimming operation )
Dimming input: Additive resistance
Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< I out<8%.
2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.
T1 T2 T3 T4
Dimming Level(%)
Operating Time(HH:MM)
**: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level.
Example: If a residential lighting application adopts D01-Type, when turning on the power supply at 6:00pm, for instance:
[1] The power supply will switch to the constant current level at 100% starting from 6:00pm.
[2] The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on.
[3] The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on.
[4] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
The constant current level remains till 8:00am, which is 14:00 after the power supply turns on.
T1 T2 T3 T4 T5
Dimming Level(%)
Operating Time(HH:MM)
**: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level.
Example: If a street lighting application adopts D02-Type, when turning on the power supply at 5:00pm, for instance:
[1] The power supply will switch to the constant current level at 50% starting from 5:00pm.
[2] The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on.
[3] The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on.
[4] The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on.
[5] The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The
constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
T1 T2 T3
Operating Time(HH:MM)
**: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level.
Example: If a tunnel lighting application adopts D03-Type, when turning on the power supply at 4:30pm, for instance:
[1] The power supply will switch to the constant current level at 70% starting from 4:30pm.
[2] The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on.
[3] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
100 100
others
80 80
230VAC 230VAC
input only 12V input only
60 60
LOAD (%)
LOAD (%)
40 40
110VAC 110VAC
20 20
100
Constant Current Mode
1
90
0.98
80
75 0.96
70 0.94
PF
0.92 277V(200W)
60
LOAD (%)
0.9 230V(200W)
50
0.88 115V(150W)
40
0.86
0.84
100 120 140 160 180 200 240 250 260 270 280 305 50% 60% 70% 80% 90% 100%
12% 277V(200W)
THD
90 277V(200W)
230V(200W)
10% 88 230V(200W)
115V(150W)
86 115V(150W)
8%
84
6% 82
4% 80
50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD LOAD
LIFE TIME
120
100
80
LIFETIME(Kh)
60
40
20
0
20 30 40 50 60 70 80 90
Tcase ( ℃ )
MECHANICAL SPECIFICATION
※ Blank-Type (for 12V model) CASE NO.: 262A Unit:mm
244
233
300±20 220 300±20
53.8
71
ACN(Blue) Vo-(Black)
tc 90
ACL(Brown) Vo+(Red)
SJOW 17AWGx2C SJTW 14AWGx2C
32
&H05RN-F 1.0mm 2
4-ψ4.5
37.5
37
244
233
300±20 220 300±20
53.8
71
ACN(Blue) 90 Vo-(Black)
ACL(Brown) tc Vo+(Red)
SJOW 17AWGx2C 2
32
4-ψ4.5
53.8
71
ACN(Blue) Vo-(Black)
tc 90
ACL(Brown) Vo+(Red)
SJOW 17AWGx2C SJTW 14AWGx2C
32
&H05RN-F 1.0mm 2
4-ψ4.5
37.5
37
21.01
14.5 38.5
244
233
300±20 220 300±20
53.8
71
ACN(Blue) Vo-(Black)
tc 90 Vo+(Red)
ACL(Brown)
SJOW 17AWGx2C
32
2
&H05RN-F 1.0mm 2 SJOW 17AWGx2C &05RN-F 1.0mm
4-ψ4.5
14.5 38.5
244
233
300±20 220 300±20
53.8
SJTW 14AWGx2C
71
Vo-(Black)
ACN(Blue) Vo+(Red)
90
ACL(Brown) tc DIM+( Blue )
SJOW 17AWGx2C DIM-( White )
32
UL2517 20AWGx2C
&H05RN-F 1.0mm 2
4-ψ4.5
37.5
37
21.01
14.5 38.5
244
233
300±20 220 300±20
SJOW 17AWGx2C
53.8
&05RN-F 1.0mm 2
71
Vo-(Black)
ACN(Blue) Vo+(Red)
90
ACL(Brown) tc DIM+( Blue )
SJOW 17AWGx2C DIM-( White )
32
UL2517 20AWGx2C
&H05RN-F 1.0mm 2
4-ψ4.5
14.5 38.5
244
233
300±20 220 300±20
53.8
SJTW 14AWGx2C
71
Vo-(Black)
ACN(Blue) Vo+(Red)
90
ACL(Brown) tc DIM+( Blue )*
SJOW 17AWGx2C DIM-( Whit e)**
32
UL2517 20AWGx2C
&H05RN-F 1.0mm 2
37.5
37
244
233
300±20 220 300±20
SJOW 17AWGx2C
53.8
&05RN-F 1.0mm 2
71
Vo-(Black)
ACN(Blue) Vo+(Red)
90
ACL(Brown) tc DIM+( Blue )*
SJOW 17AWGx2C DIM-( White )**
32
UL2517 20AWGx2C
&H05RN-F 1.0mm 2
244
233
300±20 220
53.8
71
AC/N(Blue)
AC/L(Brown) tc 90
PE (Green/Yellow) SJOW 17AWGx3C
32
SJOW 17AWGx2C
&H05RN-F 1.0mm 2 &05RN-F 1.0mm
2
4-ψ4.5
◎ Note1: Please connect the case to PE for the complete EMC deliverance and safety use.
◎ Note2: Please contact MEAN WELL for input wiring option with PE.