Ask 800
Ask 800
Ask 800
10/15-6.35 EN
(20857.bmp)
n Isolation between Process and Transmitter with Measuring The transmitter ASK 800 combines proven, mature technology wi-
Media having: • High Temperatures and Viscosities •Corro- th a trend-setting microprocessor controlled electronic.
sive Ingredients, a Tendency to Polymerization It is based on a proven, highly-stable measuring mechanism, on
n Prevention of Deposits in the Process Connection Flanges by which a remote seal with flange is fitted directly onto on side. The
internal sensing diaphragm is slightly deflected corresponding to
Extended Remote Seals
n Mounting to various DIN or ANSI Flanges
the differential pressure present between the remote seal and the
n
equalizing side and converted into an electrical signal by the elec-
Microprocessor technology tronics. Apart from a high accuracy with an almost complete com-
n High turn down ratio 30 : 1 pensation of ambient influences, both measuring mechanism and
n Digital communication using the "HART"-Protocol without
electronic provide a substantial increase in functionality.The digital
indicator can be so configured that the measured value can be il-
disturbing the output signal 4...20 mA
n Lower range value, span and damping are externally adjust-
lustrated as a physical unit, percentage value or current. In additi-
on the measuring mechanism temperature can be indicated. The
able process wetted parts of the remote seal can be selected from dif-
n Transfer response configurable: ferent materials such as stainless steel, Hastelloy C, Monel or tan-
• linear • freely programmable • PID-controller talum and others, depending upon the required resistance to
n "Intrinsic Safety" or "Flameproof Enclosure" explosion protec-
corrosion.
Various filling liquids, for example for the food and beverage indu-
tion or mounting on "Zone 0"
n
stry, complete the spectrum of applications. The Transmitter ASK
E.M.C. according to IEC 801 800 is thus an efficient, intelligent element, a must for every type of
automation.
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN
Technical Data
Measuring Mechanism Max. permissible voltage ripple of the power supply during the
communication:
Measuring limits
• 7 Vpp at 50 Hz ≤ f ≤ 100 Hz
-100% and +100% of the max. span
• 1 Vpp at 100 Hz < f ≤ 200 Hz
Lower range value
• 0.2 Vpp at 200 Hz < f ≤ 300 Hz
Continuously adjustable between the measuring limits
The following can, for example, be configured:
Span
Digital indication of process pressure, temperature, per-
Arbitrary - continuously adjustable within the range limits.
centage value, current, arbitrary process variables
The adjusted span must not to be lower than the minimum
Damping
span. Smallest span: 10 mbar.
Transfer function
2...60 mbar (0.2...6 kPa)
Alarm signalling Imin/Imax
13.34...400 mbar (1.334...40 kPa)
PID Controller; adjustment with five parameters;
0.0834...2.5 bar (8.34...250 kPa)
- Setpoint w
0.534...16 bar (53.4...1,600 kPa)
- Proportional gain Kp
1.334...40 bar (133.4...4,000 kPa)
- Reset time Tn
Characteristic
- Derivative gain KD
Linear, rising or falling Freely programmable
- Derivative action time TD
Over-ranging limit
Write-over of parameters can be prevented by the interlock
Each side may be over-loaded up to 100% of the nominal-
switch. All stored data is secured even in the event of power
pressure
supply failure.
Measuring chamber volume (equalizing side)
A detailed description of all functions can be found in the Instruc-
approx. 14 cm3
tions 42/15-910 EN.
Isolating diaphragm (equalizing side)
1.4404 (≡316 L stainless steel) General and Safety Data
Blanking plug Ambient Conditions
1.4571 (≡316 Ti stainless steel)
Ambient temperature range
Power Supply -40°C...+80°C
Transmitter operating voltage Storage and transport temperature range
UB,max= DC 45 V UB,min= DC 11.5 V -50°C...+80°C
Humidity
Output signal ≤95%, annual mean, condensation permissible
4...20 mA
Output signal limits Amplifier Enclosure, Mounting, Weight
Imin 3.5 mA, Imax 22.5 mA Material
Standard adjustment: Imin 3.8 mA and Imax 20.5 mA Die cast copperfree aluminium (GD-AlSi)/polycarbonate
Load R Protective varnish
U 11.5V US Supply voltage Epoxy resin, gravel-grey, RAL 7032
R ≤ S kΩ Degree of Protection
I Imax 20...22.5mA (adjustable)
max
IP 65 (jet waterproof) according to EN 60 529
Digital Communication (≡ NEMA standard type 4)
Standardized communication protocol "HART" 5.1 Type of Mounting / Sealing
Minimum load for communication: 250 Ω Flanged to side of container
Recommended lead-length for communication: Seal type: non metallic
• screened multi-wire: max. 1.5 km Weight
• screened two-wire: max. 3 km Approx. 12 kg
Functional Diagram ASK 800 with Remote Seal
Measuring capsule Overload diaphragm
Remote seal ( HP) Sensing diaphragm
MICROPROCESSOR-
based electronics
4...20mA
DC 11.5...45V
TEST
INSTRUMENT
Page 2 of 10 08.2000
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN
Technical Data
Contrans P
~181
FSK-Modem
~76
08.2000 Page 3 of 10
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN
Ordering Data
To order, the order number and the data of the adjustable values: lower and upper range values, will suffice.
Nominal pressure
Flange-O-rings
Buna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 060
Viton (restricted operating temperature -18°C...+80°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
PTFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
Filling liquid
Silicone oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 070
Carbon fluoride (restricted operating temperature -20°C...+80°C) . . . . . . . . . . . . . . . . . . . . . . 137
Output signal
4 . . . 20 mA, linear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 023
4 . . . 20 mA, Characteristic acc. to table of values, max. 22 pairs: Input(%);Output(%) . . . . 221
Electrical connection
One Pg 13.5 cable gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 044
Two Pg 13,5 cable glands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Two 1/2-14 NPT female threads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
One plug connector (Han 8U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
Order No. 1 5 9 . . - 2 - / / / ...
1)
Possible units: mbar, bar, Pa, kPa, mmH2O, mmHg, psi, g/cm2, kg/cm2, inches H2O, inches Hg, feet H2O.
2)
Other variations upon request.
Page 4 of 10 08.2000
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN
Analogue indicating instrument (Scale markings: 0...100 % linear) Normal or Ex "i" design . . . . . . . . . 206
Digital indicating instrument: Normal or Ex "i" design:
(indicates %, however with Code No. 415 process pressure) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
Digital indicating instrument: Ex "d" design:
(indicates %, however with Code No. 415 process pressure) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Scale indication... (please define value: e.g. 0...15 m1); 4...20 mA proportional; only combinable
with Code No. 244/245, not with Code No. 415) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416
PID Controller,Parameter: nominal value [%]; Kp (0...40); Tn [s] (0.1...3600); KD (0...40); TD [s] (1...3600)2) 415
Alarm signalling with 3.6 mA (Standard: 21 mA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417
Max. output current... (please state value 20...22.5 mA; Standard: 20.5 mA) . . . . . . . . . . . . . . . . . . . 418
Min. output current... (please state value 3.5...4 mA; Standard: 3.8 mA) . . . . . . . . . . . . . . . . . . . . . . . 420
Electrical damping TG=... (please state value to be adjusted: 0...60 s) . . . . . . . . . . . . . . . . . . . . . . . . 259
Flange screws - stainless steel (not with carbon steel flanges) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
Documentation
Instructions (state total number of copies)3)
German (42/15-992, no details required for one copy) . . . . . . . . . . . . . . . . . . . . . . . . . (...copies) Z2D
English (42/15-992 EN, Order-No. always required) . . . . . . . . . . . . . . . . . . . . . . . . . . . (...copies) Z2E
French (42/15-992 FR, Order-No. always required) . . . . . . . . . . . . . . . . . . . . . . . . . . . (...copies) Z2F
Digital Communication: User Interface "IBIS" (Data Sheet 15-6.96 EN), FSK-Modem (Data Sheet 15-6.97 EN)
Mounting Accessories see Data Sheet 15-8.98 EN (e.g. fixing screws, O ring seals)
Certificates see Data Sheet 15-6.99 EN
1)
Possible units: pressure units, as listed under "adjusted from... to..."; m, cm, mm, inches, feet, m3, l, barrels, gallons, yard3,
inches3, feet3, g, kg, t, pounds, short tons, long tons (further units see Technical Information: B 92 M 508 V)
2)
To optimise the process it is necessary to have the additional facilities available with IBIS and a modem. When no values
stipulated-standard values will be programmed i.e. setpoint = 50% and Kp = 1. Tn, KD and TD are switched off (0).
3)
One copy without charge
Scope of Supply
1 Instructions Supplied against special order:
1 Blanking plug Connecting pipe unions, flanges, valves, manifolds, remote seals,
1 Instrument socket with plug connector Power supply e.g. TZN 128 (Data sheet 18-8.39 EN),
Spare Parts Transmitter ASK.
08.2000 Page 5 of 10
Data Sheet
Flush Diaphragm Remote Seals DN 80 / ANSI 3"
15-6.35 EN
Ordering Data
Relevant Code Nos. can be continuously suffixed to the transmitter Order No.
Mounting
Direct mounting (on ASK 800 without capillary tube) . . . . . . . . . . . . . . . . . . 729
Filling liquid
Silicone Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 074
Carbon Fluoride . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687
Distilled Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688
Vegetable Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673
Vacuum-Proof Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739
with FEP coating (medium temperature ≤ 150 °C, only with Code Nos. 605/606) . . . . . . . . . . . . . 662
Ex Design for "Zone 0" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689
1)
The ordering data for DIN und ANSI cannot be combined with each other.
Page 6 of 10 08.2000
Data Sheet
Extended Diaphragm Remote Seals DN 80 / ANSI 3"
15-6.35 EN
Ordering Data
Relevant Code Nos. can be continuously suffixed to the transmitter Order No.
Mounting
Direct mounting (on ASK 800 without capillary tube) . . . . . . . . . . . . . . . . . . 729
Filling liquid
Silicone Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 074
Carbon Fluoride . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687
Distilled Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688
Vegetable Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673
Vacuum-Proof Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739
1)
The ordering data for DIN und ANSI cannot be combined with each other.
08.2000 Page 7 of 10
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN
Dimensional Diagrams
Errors and omissions excepted. All dimensions in millimeters (mm). Seals and fixing materials not supplied.
a b ~294
80
10
79 2)
DIN
ød3
ød2
ød4
105
øK
øD
Contrans
ANSI
~28
108
~161 1)
34
4 6 12 13
Design with
extended diaphragm Form V13 Sealing Surface
Ext. length
50/100/150
mm c b
a
90
ø 138
ø 120
7
1
ød3
ød1
ød4
øK
øD
41.3
3
~200 1)
M 0 10 6 4 E 1.E PS
5
9 12 13
Page 8 of 10 08.2000
08.2000 Page 9 of 10
ABB Automation Products GmbH Subject to technical changes.
Schillerstraße 72 Printed in the Fed. Rep. of Germany
10/15-6.35 EN 08.2000
D-32425 Minden
Tel. +49(0)571 830-0
Fax +49(0)571 830-1846
http://www.abb.de/automation