Isocal 6

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

-25 to 250°C

ISOCAL - 6 Range
ACROSS RANGE

Hyperion • Drago
g Multi Function: Six Modes including Dry Block and
Liquid Bath
g 65mm Volume: Ideal Liquid Bath
g Calibrate entire measurement loop - using a heat
source rather than an electrical simulator, a test
instrument and sensor can be calibrated as a system

The Hyperion and Drago have large calibration volumes,


65mm x 160mm deep, which makes them ideal to use as
portable liquid baths. Stirred liquid baths are suitable for
temperature sensors of all types, sizes and shapes. Liquid
Baths can provide smaller calibration uncertainties than dry
blocks and when used with suitable reference thermometers,
accuracies of up to 0.005°C can be achieved.
These models are part of the award winning Isocal-6 family
and with a reference probe can be used with different
accessories for Dry Block, Infrared, Surface Calibration and
even with ITS-90 Fixed Point Cells for uncertainties to
0.001°C. In Dry Block Mode, the large 65mm diameter
block allows for the calibration of either larger probes or for
calibrating many sensors simultaneously.
As a Liquid bath the sensors can be placed directly into the
stirred liquid thus avoiding the need for specially drilled
blocks. If the liquid is directly in the block then the controller
only model, or Basic (B) model, can be selected. However,
instead of putting liquids directly in the block liquid Scan to view Hyperion and Drago
containers can be used to facilitate rapid change of fluids.
For greater accuracy, or when using a liquid container, Dry
Alternatively the SITE or ADVANCED model can be
Block Insert, Blackbody Target or the Surface Sensor Kit a
selected; the SITE includes a temperature indicator for a
separate reference thermometer should be used to
reference probe. The ADVANCED also includes inputs for
compensate for the varying offset between the controller
test thermometers, automatic temperature cycling, logging
and the accessory temperature.
and additional sophisticated features.
An ideal arrangement would be to include the handheld
All models include I-Cal Easy LOG software and the
Isotech TTI-10 or the bench top Isotech milliK Precision
ADVANCED models additionally include software to
Thermometer and Model 935-14-16 Semi Standard
manage logged data and configure the unit, see page 14
Platinum Resistance Thermometer.
for more details.

ADVANCED SITE BASIC

16 | CALIBRATION SOLUTIONS
PARAMETER Model

Hyperion 4936 Drago 4934


Temperature Range -25°C to 140°C 1
30°C to 250°C2
ADVANCED Range
Stability: Dry Block / Liquid Bath ±0.005°C 50°C ±0.005°C / 150°C ±0.03°C
Display Resolution 0.001°C over whole range 0.001°C over whole range
Accuracy: RTD Input Channels ±0.05°C ±0.005% RDG
Accuracy: Thermocouple Input Channels E,J,K,N: ±0.2°C @ 660°C R: ±0.6°C S: ±0.7°C @ 660°C T ±0.2°C @ 150°C
CJC Accuracy ±0.35°C
BASIC / SITE Range
Stability ±0.03°C ±0.03°C
Display Resolution 0.01°C from -19.99 to 99.99°C then 0.1C: 0.01°C Over PC Interface
COMMON Specifications
Stability Blackbody ±0.3°C Surface Sensor ±0.5°C ITS-90 Cells ±0.0005°C
Display Accuracy 3 0.15°C 0.15°C
Uniformity - Radial, Liquid Bath Mode <0.009°C <0.007°C
Uniformity - Axial, Liquid Bath Mode <0.011°C <0.013°C
(40mm)
Uniformity - Radial, Dry Block Mode <0.008°C <0.008°C
(Between Wells)
Uniformity - Axial, Dry Block Mode <0.040°C <0.040°C
(40mm)
Heating Time -20°C to 140°C: 40 Mins 30°C to 250°C: 40 Mins
Cooling Time 140°C to 20°C: 90 Mins 250°C to 30°C: 90 Mins
20°C to -25°C: 80 Mins
Insert Size 65 x 160mm
Insert Types Standard 8 x 8mm + 2 x 4.5mm, Undrilled or Custom Drilled
Power 115 or 230Vac 50/60Hz 200 Watts 115 or 230Vac 50/60Hz 1000 Watts
Dimensions 384H (including handle) x 212W x 312D mm
Weight 12kg 8kg
(1) In ambient of 20°C: Minimum Temperature is 45°C Below Ambient, Absolute Minimum -35°C
(2) In ambient of 20°C
(3) Dry Block Mode only: Comparing 4.5mm Well to Display Value.

ADVANCED SITE BASIC

Digital Display of Set and


Yes Yes Yes
Nominal Block Temperature
PC Interface Ethernet + USB Host Serial Serial
Test Thermostats Yes - Two Inputs Yes - Single Input No
Independent Temperature
Yes Yes No
Indicator for Reference Probe
Up to 3: Two universal
inputs for PRT,
Additional Inputs for Units
Thermocouple or Process No No
Under Test
inputs and a further
Thermocouple input
Automatic Temperature
Yes No No
Cycling
Data Logging Yes - Export to USB No No
Yes - block can follow
Offset Elimination No No
reference input
Choose English, French,
Yes - on full colour display No No
Italian or Spanish Language
In Built Web Server Yes No No
Yes - Suitable for life
Tamper Proof Data science, automotive and No No
aerospace applications

CALIBRATION SOLUTIONS | 17
Hyperion / Drago
ISOCAL-6 Accessories
LIQUID & DRY BLOCK Dry Block Mode with Inserts
936-06-01a Standard Insert is:
8 x 8mm + 2 x 4.5mm all 157mm Deep.
All Inserts have a 4mm tapped hole to suit
Metal Block Bath supplied extractor tool.
Dry Block Calibrator provides fast and clean calibration of Alternative Inserts
thermocouples, PRTs and other industrial sensors. Isotech 936-06-01b Blank Insert
blocks use a combination of multi zone and advanced 936-06-01c Special Insert.
materials technology to ensure constant temperature zones
for high accuracy calibration. Stirred Liquid Mode with Liquid
Container Kit 936-06-02
Allows liquid bath use, includes container,
Stirred Liquid Bath magnetic stirrer, probe guide and sealing
cap.
Remove the metal block to convert to a stirred liquid bath.
Liquid bath operation allows angled or awkward shaped
Stirred Ice Bath Mode with Liquid
probes to be calibrated. Accuracies are improved over Dry
Blocks alone and with a suitable reference probe performance Container Kit
of 0.005°C is achievable. Uses same liquid kit to provide 0°C
reference as a stirred ice bath.
Thermometer Support Kit 936-06-08
Stirred Ice / Water Bath Supports up to eight thermometers into
liquid. Suits probes 5mm - 8mm in
The ISOCAL-6 models that operate below 0°C can be used to diameter.
provide a 0°C stirred ice / water bath. This provides a simple
low cost way of checking that standards have not drifted in
936-06-07 C10 Oil -35°C – 140°C 1L
between calibrations. 580-06-09 C20 Oil 20°C – 200°C 1L
915/09 VH Oil 150°C – 250°C 1L

Infrared Calibration Mode with Blackbody


Target 936-06-03
Blackbody Source Use optional Probe 936-14-61DB.
Adding the blackbody target allows the testing of infrared
thermometers. Low cost non-contact IR thermometers are
increasingly being used in industry and the ISOCAL-6 is
ideal to test and check these devices. The IR thermometer is Surface Sensor Calibration with Surface
focused on the target and compared to a reference probe in
Sensor Kit 936-06-04
the block pocket.
Includes an Insert and an angled platinum
resistance thermometer.
Surface Sensor Calibrator
With the Surface Sensor Kit the test sensor is compared to ITS-90 Fixed Point Cells
a platinum resistance thermometer located just below the
B8 Water Triple Point Cell (Hyperion)
surface of the block. Again save the cost of buying additional
equipment by adding accessories as required to expand the
17401 Slim Gallium Slim Cell
ISOCAL-6 for new calibration applications. 936-06-09 Cell Holder Assembly

Calibration
ITS-90 Fixed Point Apparatus Includes three point traceable calibration
For the best possible performance with uncertainties to certificate for block temperature
0.0005°C (0.5mK) add an ITS-90 Fixed Point Cell. The most UKAS Calibration
popular is the B8 Water Triple Point Cell, it is surprisingly UKAS Calibration available to order, legally
affordable and simple to use - the triple point can be both traceable in more than 70 countries.
created and maintained in the apparatus without the need for
any other equipment or supplies. Standard Probe 935-14-61/DB
Platinum Resistance Thermometer. 4mm
diameter.

Current Loop Interface 935-06-161


24VDC Power Supply and Terminal Box.
World’s First Powers 4-20mA Current Transmitters with

Multi-Functional 4mm terminal posts for easy connection.

Baths Carrying Case 931-22-112


SIX FUNCTIONS Sturdy case with room for accessories.
Features wheels and pull out handle.
Isocal-6 Performance and Use
Hyperion Performance - Dry Block Drago Performance - Dry Block
0.1°C 0.1°C
0.1
0.08
0.08°C 0.08°C

0.06
0.06°C 0.06°C

0.04
0.04°C 0.04°C

0.02°C 0.02°C
0.002
0.004 0.001
0.002 -0.001
0°C 0°C

-0.02°C -0.02°C

-30°C 0°C 30°C 60°C 90°C 120°C 150°C 0°C 25°C 50°C 75°C 100°C 125°C 150°C 175°C 200°C 225°C 250°C

g Audit Calibration (Similar Sensors) S model with UKAS option See Evaluation Reports for full
g Radial Homogeneity details http://www.isotechna.com

Alternative Methods of Calibrating with an Isocal-6


Advanced Model

Basic Model
Site Model

ADVANCED Model SITE Model BASIC Model


n Digital Display of Set and n Digital Display of Set and n For Quick and Easy Testing
Nominal Block Temperature Nominal Block Temperature n Digital Display of Set and
n Inbuilt three channel indicator for n Inbuilt single channel indicator Nominal Block Temperature
reference probe and units under for reference probe n Use with a separate external
test n Best Practice calibration with indicator to compensate for
n Advanced features including established traceability and gradients and loading
automatic Temperature Cycling uncertainty
and Logging
n Best Practice calibration with
established traceability and
uncertainty

UKAS Calibration available for these systems - International Traceability - Best Practice See page 14