5991-5897EN - 8355 XCD - Brochure - LR
5991-5897EN - 8355 XCD - Brochure - LR
5991-5897EN - 8355 XCD - Brochure - LR
REIMAGINED. REDESIGNED.
AGILENT 8355 SULFUR CHEMILUMINESCENCE DETECTOR (SCD)
2
Meeting your needs for sensitivity, ASTM
compliance, and ease of maintenance
Full integration
The Agilent 8355 SCD is now completely integrated into
the Agilent 7890B GC with OpenLab CDS and MassHunter
software – streamlining your lab’s analytical workflows and
its ability to comply with regulatory requirements.
Dual-plasma design
Eliminates quenching (signal suppression) caused by coelution
of sulfur components and hydrocarbons.
Learn more about the only integrated system for low-level sulfur analysis. Visit agilent.com/chem/SCD
3
FULL GC INTEGRATION
MAKES COMPLEX ANALYSES MORE ROUTINE
Now your lab can run trace-sulfur methods with minimal instrument
setup and configuration. This robust, ready-to-go system – the only
one of its kind – gives you:
• Improved accuracy and repeatability: Patented electronic
pneumatic control technology maintains proper flow and split ratios
for all flow gases within the system. Electronic flow control also
enables visual identification of readings to 0.002 accuracy.
• Conformity to industry standards: Fully supports ASTM
methodologies.
• Easy method addition or modification through direct
communication between the Agilent 7890B GC and the
Agilent 8355 SCD.
• Full dynamic range: The 8355 SCD supports a large range of
concentrations without peak truncation, providing full digital data
without the need of A/D conversion.
The Agilent 8355 SCD is compatible with The Agilent 8255 Nitrogen
Agilent legacy and third-party GC systems, Chemiluminescence Detector
so your lab can experience all the produces a linear and equimolar
advantages of increased sensitivity and response to nitrogen compounds.
simplified maintenance. (Ranged analog Learn more at:
output, A/D box, or AIB board required.) agilent.com/chem/NCD
4
SIMPLIFIED DESIGN
TURNS MAINTENANCE TIME INTO UPTIME
Previous generation sulfur chemiluminescence detectors can be Reducing complexity improves uptime readiness
notoriously complex to maintain, due to their large number of
components and fittings – particularly in the burner.
The Agilent 8355 SCD solves this problem with newly redesigned
features that enhance performance while reducing maintenance
time and costs:
• The dual-plasma burner is now easier to maintain than ever.
355 8355 355 8355 355 8355
• New electronic flow controls improve accuracy and precision.
Pathway Burner Inner tube
• The ozone generator has been optimized for efficiency
connections components change time
and durability. Reduced ~ 40% Reduced ~ 50% Reduced ~ 92%
Significantly decreasing Making the inner Change the inner
the number of potential ceramic tube easier ceramic tube in as
leak points compared to to replace. little as 10 minutes,
model 355. as opposed to
2 hours.
Learn more about the only integrated system for low-level sulfur analysis. Visit agilent.com/chem/SCD
5
ENERGY AND CHEMICAL APPLICATION
ASTM D5623:
Analysis of Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur
Selective Detection
Sulfur-containing compounds are notorious for their detrimental The 8355 SCD is the unit of choice for performing accurate
effects as catalyst poisons; therefore, your starting materials must be quantitation and speciation of sulfur compounds in petroleum liquids.
of the highest purity – particularly when using very selective catalysts.
Average
Stability of t-butyl disulfide over one month
Concentration Normalized Standard % pA
1200
(approx.) Response Deviation RSD
Factor
1000
0.1 ppm 0.099 0.007 6.8
6
ENERGY AND CHEMICAL APPLICATION
ASTM D5504:
Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography
and Chemiluminescence
Gas chromatography with sulfur chemiluminescence detection such as paraffins, benzene, toluene and xylenes; and fuels such as
provides a rapid means of identifying and quantifying sulfur natural gas, LPG, gasoline, kerosene, jet, and diesel.
compounds in petroleum feeds and products. Examples include sulfur
compounds in monomers such as ethylene and propylene; solvents
3-methylbenzothiophene
17, 18
9
2-bromothiophene
.56
.66
:3
21
ea
:3
Ar
100
600
8. 2-butanethiol 21. 2-methylbenzothiophene
1-Butanethiol
01
80
500
23. Phenyl sulfide
62
9.7
3
26
e a:
Ar
13 22
400 8 16
14 15
60 7 19
2
300 4 6 10 21
9 23
5
11, 12
1
40
200
20
100
20
5 10 15 20 25 min 5 10 15 20 25 min
Low-level detection of sulfur compounds. These results demonstrate the high ASTM compliant performance allows for detection of components of interest.
accuracy and precision of the Agilent 8355 SCD.
Greatly improve SCD stability with Agilent J&W DB-Sulfur SCD columns
Thick-film PDMS columns commonly used with SCD are prone to excessive bleed at high
temperatures. When this happens, column bleed components accumulate and foul (coke) onto SCD
burner ceramic tubes, destabilizing detector response over time.
Agilent J&W DB-Sulfur SCD columns are optimized for low bleed.
This reduces fouling of SCD ceramic tubes – minimizing instrument downtime and operational costs.
In addition, DB-Sulfur SCD columns provide excellent peak shape and extended detector stability for
all GC SCD methods that utilize PDMS stationary phases – such as ASTM D5623 and D5504.
Learn more about the only integrated system for low-level sulfur analysis. Visit agilent.com/chem/SCD
7
At Agilent, we understand that most labs have several instrument vendors on their bench – each
having a unique role in achieving outstanding analytical data.
That’s why Agilent CrossLab goes beyond parts to deliver full laboratory support.
With Agilent CrossLab, you get access to consumables, services, and expertise for multivendor
instruments, so you can generate the best possible data and stay up and running at full capacity.
But that’s only part of the story. Agilent CrossLab is also your pipeline to a global team of experts
who bring you vital, actionable insights for improving your science and enhancing your operations
– from a single instrument through your entire workflow. It’s a simple way to control your very
complex laboratory.
Learn more
agilent.com/chem/SCD
Buy online
agilent.com/chem/store
Europe
info_agilent@agilent.com
Asia Pacific
inquiry_lsca@agilent.com